    SERVICE GUIDE for A gilent 6610xA Pow er M odules Serial Numbers: A gilent M odel 66101A : US34440101 and up A gilent M odel 66102A : US34210101 and up A gilent M odel 66103A : US34210101 and up A gilent M odel 66104A : US34450101 and up A gilent M odel 66105A : US34210101 and up A gilent M odel 66106A : US34210101 and up For instrum ents with high ...

  • Agilent Technologies 6610XA - page 2

    2 CERTIFICA TION Agilent Technologies certifies that this product met its published specifications at time of shipment from the factory. Agilent Technologies further cer tifies that its calibration measurements are tr aceable to the United States National Bureau of Standards, to the extent allowed by the Bur eau’ s calibration facility, and to th ...

  • Agilent Technologies 6610XA - page 3

    3 SAFETY SUMMARY The following general safety pr ecautions must be obs erved during all phas es of operation of this power module. Failure to comply with thes e prec autions or with specific warnings elsewhere in this guide violates safety standards of des ign, manufacture, and intended use of the power module. Agilent Tec hnologies ass umes no lia ...

  • Agilent Technologies 6610XA - page 4

    4 Printing History The current editio n o f this guide is indicated below. Reprints o f this guide co ntaining m inor co rrections and updates may have the same printing date. New editions are identified by a new pr inting date and, in some cases, by a new part number. A new edition inco rp orates all new or corrected material since the previous ed ...

  • Agilent Technologies 6610XA - page 5

    5 Table of Contents Overview.................................................................................................................................................................................. 7 About This Man ual .......................................................................................................................... ...

  • Agilent Technologies 6610XA - page 6

    6 Installin g the Power Board ............................................................................................................................................. 58 Installin g the Bias Board ................................................................................................................................................ 58 ...

  • Agilent Technologies 6610XA - page 7

    Overv iew 7 1 Overview About This Manual This m anual is a complete g uide for serv icing t he Agil ent 6610xA Pow er Modul es. Troubleshootin g inform ation f or the Agi lent 66000A MPS Mainfram e is provided in the m ainfram e service m anual (s ee "Related Docum ents"), wh ich shou ld be used with this m anual. Note Troublesh ooting th ...

  • Agilent Technologies 6610XA - page 8

    Overv iew 8 Related Docume nts The following documents are related to this manual: Manual Part Number Description Ag ilent 66000A MPS Mainfr ame Installation Guide 66000-90001 Provides p r o duct specifications, installation, and connection information. Ag ilent Se ries 6610xA MPS Power Modules User’ s Gu ide 5959-3386 Describes t he operation of ...

  • Agilent Technologies 6610XA - page 9

    Overv iew 9 Safety Considerations The Agi lent 6610xA Power Modu les are Safety Class 1 instrum ents that connect to a protective earth termin al wh en properly installed i n an Ag ilent 66000A MPS Mainfram e. Refer to t he Safety Sum mary page at th e beginni ng of th is man ual for general saf ety procedures and th e meaning of safety sym bols ap ...

  • Agilent Technologies 6610XA - page 10

    Overv iew 10 The follow ing equ ipmen t is required to v erify and troublesh oot the Ag ilent 6610x A Powe r Modules: Table 1-1. Serv ice Test Equipment Equipment Required Critical Specifications Recommended Model Use 1 GPIB Controller Full GPIB capabilities HP Series 200/300 comput er T Oscilloscope Sensitivity: 1m V Bandwidth Limit: 20MHz Prob e: ...

  • Agilent Technologies 6610XA - page 11

    Verification and Performance T ests 11 2 V erification and Performance T ests This chapte r contains t est procedures to ch eck the operation of the Ag ilent 6610x A Powe r Modules. The required t est equipm ent is specified in Ch apter 1. Sample perform ance test record sheets are included at th e end of the chapter. Instructions are given for per ...

  • Agilent Technologies 6610XA - page 12

    12 Verification and Performance T ests Measurement Techniques Setup for Most Tests Most tests are perform ed at the rear terminals as sh own in th e following figure. Measure the dc voltag e directly at the + S and - S term inals. Set the conn ector sense sw itch for local sensing and use adequate w ire gauge f or load leads as described in Chapter ...

  • Agilent Technologies 6610XA - page 13

    Verification and Performance T ests 13 Table 2-1. Pow er Module Voltage and Current Values A gilent Model Full-Scale Voltage M ax. Prog. Voltage Full-Scale Current M ax. Prog. Current M ax. Prog. Overv oltage 66101A 8V 8.190V 16A 16.380A 10V 66102A 20V 20.475V 7.5A 7.678A 24V 66103A 35V 35.831V 4.5A 4.607A 42V 66104A 60V 61.425V 2.5A 2.559A 72V 661 ...

  • Agilent Technologies 6610XA - page 14

    14 Verification and Performance T ests CV Source Effect This test measures the change in output voltage that results from a change in ac line voltage from the m inimum to m aximum value within the line voltage specifications. 1. Turn o ff the module and c o nnect the ac p ower line through a variable -voltage tra nsfo rmer. 2. Connect th e output a ...

  • Agilent Technologies 6610XA - page 15

    Verification and Performance T ests 15 unloading transients b y triggering o n the p o sitive and negative slope. Figure 2-2. Transient Response W aveform Constant Current (CC) Tests CC Setup Follow the general setup instructions in the Measurement Techniques paragraph and the specific instructions given in the following pa r agrap hs. Current Prog ...

  • Agilent Technologies 6610XA - page 16

    16 Verification and Performance T ests The follow ing steps show how to set up an Agi lent 3458A Sy stem Voltmeter f rom its f ront panel to tak e a statistical av erage of 100 readin gs. represents the un labeled shift key in the FUNCTION/RANGE group. 1. Program 10 power li ne cycles per sample by pressin g . 2. Program 100 sam ples per trig ger b ...

  • Agilent Technologies 6610XA - page 17

    Verification and Performance T ests 17 Note You m ay w ant to use th e average reading prog ram described previou sly. 7. Adjust the transformer to the HIGH line v oltage (e.g., 132Vac for a 115Vac n ominal in put, or 250Vac for a 230Vac nom inal input), an d record the output curren t reading. 8. The difference in the current reading s in steps (6 ...

  • Agilent Technologies 6610XA - page 18

    18 Verification and Performance T ests Table 2-2. Perf ormance Test Record for M odel A gilent 66101A (8V, 16A ) Pre Cal_____________Post Cal______________ Mod el A gilent 66101A Tem perature___________________________Test Perform ed By_______________________ Serial Nu mber_______________________Hu mid ity________________________Date_______________ ...

  • Agilent Technologies 6610XA - page 19

    Verification and Performance T ests 19 Table 2-3. Perf ormance Test Record for M odel A gilent 66102A (20V, 7.5A ) Pre Cal_____________Post Cal______________ Mod el A gilent 66102A Tem perature___________________________Test Perform ed By______________________ Serial Nu mber_______________________Hu mid ity________________________Date______________ ...

  • Agilent Technologies 6610XA - page 20

    20 Verification and Performance T ests Table 2-4. Perf ormance Test Record for M odel A gilent 66103A (35V, 4.5A ) Pre Cal_____________Post Cal______________ Mod el A gilent 66103A T emperatu re___________________________Test Perform ed By______________________ Serial Nu mber_______________________Hu mid ity________________________Date_____________ ...

  • Agilent Technologies 6610XA - page 21

    Verification and Performance T ests 21 Table 2-5. Perf ormance Test Record for M odel A gilent 66104A (60V, 2.5A ) Pre Cal_____________Post Cal______________ Mod el Agilent 66104A Te mperatu re___________________________Test Perform ed By______________________ Serial Nu mber_______________________Hu mid ity________________________Date______________ ...

  • Agilent Technologies 6610XA - page 22

    22 Verification and Performance T ests Table 2-6. Perf ormance Test Record for M odel A gilent 66105A (120V, 1.25 A ) Pre Cal_____________Post Cal______________ Mod el Agilent 66105A T emperatu re___________________________Test Perform ed By______________________ Serial Nu mber_______________________Hu mid ity________________________Date___________ ...

  • Agilent Technologies 6610XA - page 23

    Verification and Performance T ests 23 Table 2-7. Perf ormance Test Record for M odel A gilent 66106A (200V, 0.75A ) Pre Cal_____________Post Cal______________ Mod el Agilent 66106A T emperatu re___________________________Test Perform ed By______________________ Serial Nu mber_______________________Hu mid ity________________________Date____________ ...

  • Agilent Technologies 6610XA - page 24

    ...

  • Agilent Technologies 6610XA - page 25

    Troubleshooting 25 3 T roubleshooting This chapte r provides troubles hooting and repair inform ation f or the Ag ilent 6610xA Power Modu les. Before attem pting to troubleshoot the modules, ensure that the problem is not with an external circuit or application, the mainframe, the GPIB controller, the applicatio n program, or the input power line. ...

  • Agilent Technologies 6610XA - page 26

    26 Troubleshooting þ Figu re 3-5 - Troublesh ooting No Ou tput þ Figure 3 -6 - Tro ublesho o ting High Output þ Figure 3-7 - Tr o ubleshooting Will No t Overvoltage þ Figu re 3-8 - Troublesh ooting C V Accuracy þ Figu re 3-9 - Troublesh ooting C C Accuracy þ Figu re 3-10 - Troubl eshooting Down programm er þ Figu re 3-11 - Troublesh ooting D ...

  • Agilent Technologies 6610XA - page 27

    Troubleshooting 27 Figure 3-1. Overall Troubleshooting (Sheet 1 of 3) ...

  • Agilent Technologies 6610XA - page 28

    28 Troubleshooting Figure 3-1. Overall Troubleshooting (Sheet 2 of 3) ...

  • Agilent Technologies 6610XA - page 29

    Troubleshooting 29 Figure 3-1. Overall Troubleshooting (Sheet 3 of 3) ...

  • Agilent Technologies 6610XA - page 30

    30 Troubleshooting Figure 3-2. Troubleshooting M icroprocessor Circuits (Sheet 1 of 2) ...

  • Agilent Technologies 6610XA - page 31

    Troubleshooting 31 Figure 3-2. Troubleshooting M icroprocessor Circuits (Sheet 2 of 2) ...

  • Agilent Technologies 6610XA - page 32

    32 Troubleshooting Figure 3-3. Troubleshooting Error M essages ...

  • Agilent Technologies 6610XA - page 33

    Troubleshooting 33 Figure 3-4. Troubleshooting Overvoltage at T urn-On (Sheet 1 of 2) ...

  • Agilent Technologies 6610XA - page 34

    34 Troubleshooting Figure 3-4. Troubleshooting Overvoltage at T urn-On (Sheet 2 of 2) ...

  • Agilent Technologies 6610XA - page 35

    Troubleshooting 35 Figure 3-5. Troubleshooting No Output (Sheet 1 of 5) ...

  • Agilent Technologies 6610XA - page 36

    36 Troubleshooting Figure 3-5. Troubleshooting No Output (Sheet 2 of 5) ...

  • Agilent Technologies 6610XA - page 37

    Troubleshooting 37 Figure 3-5. Troubleshooting No Output (Sheet 3 of 5) ...

  • Agilent Technologies 6610XA - page 38

    38 Troubleshooting Figure 3-5. Troubleshooting No Output (Sheet 4 of 5) ...

  • Agilent Technologies 6610XA - page 39

    Troubleshooting 39 Figure 3-5. Troubleshooting No Output (Sheet 5 of 5) ...

  • Agilent Technologies 6610XA - page 40

    40 Troubleshooting Figure 3-6. Troubleshooting High Output ...

  • Agilent Technologies 6610XA - page 41

    Troubleshooting 41 Figure 3-7. Troubleshooting Will Not Ov ervoltage ...

  • Agilent Technologies 6610XA - page 42

    42 Troubleshooting Figure 3-8. Troubleshooting CV A ccuracy ...

  • Agilent Technologies 6610XA - page 43

    Troubleshooting 43 Figure 3-9. Troubleshooting CC A ccuracy ...

  • Agilent Technologies 6610XA - page 44

    44 Troubleshooting Figure 3-10. Troubleshooting Downprogrammer ...

  • Agilent Technologies 6610XA - page 45

    Troubleshooting 45 Figure 3-11. Troubleshooting DA C Circuit ...

  • Agilent Technologies 6610XA - page 46

    46 Troubleshooting Figure 3-12. Troubleshooting Readback Circuits (Sheet 1 of 2) ...

  • Agilent Technologies 6610XA - page 47

    Troubleshooting 47 Figure 3-12. Troubleshooting Readback Circuits (Sheet 2 of 2) ...

  • Agilent Technologies 6610XA - page 48

    48 Troubleshooting Test Points The following test points are referenced in the troubleshooting flowcharts. Refer to the component locations diagram in Chapter 6 for the actual location o f the test po ints on the pc board. Table 3-1. T est Points Test Point Description TP 0 Outpu t circuit com mon (located on inboard s ide of R303) TP 1 +5V (4.8 to ...

  • Agilent Technologies 6610XA - page 49

    Troubleshooting 49 Table 3-2. S3 T est Settings S3 Setting Test Descript ion 8 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 Start w ith blank f ront panel 0 0 0 1 0 0 0 0 Front pan el w ith all s egmen ts on 0 0 0 0 0 0 0 1 VDAC m ini mum (TP16 = 0V) 0 0 0 1 0 0 0 1 VDAC m axi mum (TP16 = -VREF) 0 0 0 0 0 0 1 0 IDAC mini mum (TP17 = 0V) 0 0 0 1 0 0 1 0 IDAC maxi ...

  • Agilent Technologies 6610XA - page 50

    50 Troubleshooting Figure 3-13. S3 Swit ch Setting Wavefo rms ...

  • Agilent Technologies 6610XA - page 51

    Troubleshooting 51 EEPROM Troubleshooting and Initialization Troubleshooting The power m odule can detect an EEPROM ch ecksum error. This error is not iden tified by nu mber, but causes th e followin g symp to ms: þ The power m odule starts up w ith both the VOLTS and A MPS full-scale program min g and m etering ranges accepting valu es up to 1000 ...

  • Agilent Technologies 6610XA - page 52

    52 Troubleshooting 10 ! Program to in itialize EEPROM or move f actory preset data in 66101A , 20 ! 66102A, 66103A , 66104A, 66105A an d 66106A pow er supply modu les. 30 ! Rev A .00.00 dated May 27, 1993 40 ! 50 DIM Init_data (1:39),Model$[6],Idn$[21],Cal_data$[40] 60 INTEGER Addr(1:39),L ength (1:39) 70 ASS IGN @Ps TO 70500 ! Su pply m ust be at ...

  • Agilent Technologies 6610XA - page 53

    Troubleshooting 53 510 ! 520 Eprom_dat a_106a: ! ! EEPRO M data for 66106A 530 DATA 16.4035,32.3969,204.75,0,65,0,4403.67,30.0918,0.768,0 540 DATA 67,4,0.9,5.25,240,0,255,100,20,66106 550 DATA 131.18,.248047,35231.2,- 28.4202,0,0,4,66106,20,150 560 DATA 20,150,28321,40,20,10,82,84,0 570 ! 580 INPUT “ Input Power S upply mode l num ber. E xam ple: ...

  • Agilent Technologies 6610XA - page 54

    54 Troubleshooting 1010 NEXT I 1020 ! 1030 OUTPUT @Ps;"*CLS " ! Clears power su pply reg isters 1040 ! 1050 OUTPUT @Ps;"CAL;S T ATE ON," ! Turn on cal mode, "0" passcode 1060 ! 1070 GOSUB Ps_error ! Error if passcode is not " 0 " ! 1080 IF Err THEN 1090 OUTPUT @Ps;"*IDN?" ! Get data f rom m odel # l ...

  • Agilent Technologies 6610XA - page 55

    Troubleshooting 55 1510 OUTPUT @Ps;"DIAG:EEPR ’ ’ ;Addr(I);’ ’ ,’ ’ ;Len gth(I);’ ’ ,’ ’ ;Init_dat a(I) 1520 NEXT I 1530 GOTO Cal_of f 1540 ! 1550 Fact_preset: ! 1560 CLEA R SC REEN 1570 PRINT "T his program s hould ONLY be com pleted if your pow er supply ” 1580 PRINT "EEP ROM h as been replaced or a compon ent ...

  • Agilent Technologies 6610XA - page 56

    56 Troubleshooting 2010 STOP 2020 END IF 2030 ! 2040 PRINT "Operation com plete. Program stopped." 2050 STOP 2060 ! 2070 Ps_error: ! Error ha ndling subrouti ne 2080 OUTPUT @Ps;"SYST :ERR?" ! Ch eck for errors 2090 ENTER @Ps;Err 2100 RETURN 2110 ! 2120 END Figure 3-14. EEPRO M Initializ ation Program ( Sheet 5 of 5) Disassembly ...

  • Agilent Technologies 6610XA - page 57

    Troubleshooting 57 Removing the Front Panel Assembly 1. Carefully unplug the front panel cable fro m the J3 co nnecto r on the Power board. 2. Spread the botto m of the chassis away from the front panel assem bly and lift the assembly out of the chassis. Removing the Power Board 1. Carefu lly u nplug t he front pan el cable from the J3 conn ector, ...

  • Agilent Technologies 6610XA - page 58

    58 Troubleshooting Figure 3-15. Front Panel A ssembly Locking Tabs Installing the Power Board 1. Insert the tabs alon g the bottom edg e of the board in the correspon ding slots on the bottom of the chassis an d carefully install the board in the chassis. 2. Use the T10 driver and insert th e four screws (two tow ard the back and tw o near the cent ...

  • Agilent Technologies 6610XA - page 59

    Troubleshooting 59 Installing the Front Panel Board and Front Panel Assembly 1. Install the front panel, the front panel bo ard, and the latch assembly in one of the front assem bly halves. 2. Make sure that the front panel board is p o sitioned in the slot closest to the front panel. 3. Carefully snap the other half of the front panel assembly tog ...

  • Agilent Technologies 6610XA - page 60

    ...

  • Agilent Technologies 6610XA - page 61

    Theory Of Op eration 61 4 Theory of Operation This chapte r provides a brief t heory of operation for th e Agilen t 6610xA Pow er Modules . Figure 4- 1 is a block diagram of the prim ary circuit fu nctions of th e power m odules. The diagram ref erences the schem atic sheets where th e circuits are located. AC Input and Bias Supplies AC input power ...

  • Agilent Technologies 6610XA - page 62

    62 Thoery Of Operat ion Figure 4-1. Block Diagram ...

  • Agilent Technologies 6610XA - page 63

    Theory Of Op eration 63 CV Amplifier The CV amplifier controls the output of the power module w hen the module is operating in constant voltage mode. The CV amplifier consists of tw o stages: an error amplifier stage and a voltage monitor stage. The calibrated CVP ROG* signal from the CV DAC pulls current out of the negative input of the error am p ...

  • Agilent Technologies 6610XA - page 64

    64 Thoery Of Operat ion Pulse-Width Modulator, FETS, and Isolation Transformer The pulse-w idth m odulator controls the FETS. The FETS are arranged in an "H" bridge config uration with the + and - dc rail at the top and bottom of the H. The 4 FETS are located on each leg of the "H" , and the isolation transform er is located on ...

  • Agilent Technologies 6610XA - page 65

    Theory Of Op eration 65 OV Circuit The OV circuit consists of a com parator that com pares the output voltage of the module w ith an ov ervoltage reference signal and sh uts down the output w hen the ou tput of the supply exceeds the overv oltage reference level. The microprocessor generates the overvoltage reference by putting out a pulse-wi dth m ...

  • Agilent Technologies 6610XA - page 66

    ...

  • Agilent Technologies 6610XA - page 67

    Replacement Parts 67 5 Replacement Parts Table 5-1 list s the electrical componen ts of the A gilen t 6610xA Pow er Modules’ mai n, bias, and f ront panel boards. Table 5-2 lists the m echanical com ponents of the m odule. Table 5-3 lists all of the com ponents of the connector assem bly. These tables pro vide the follo w ing information: þ Refe ...

  • Agilent Technologies 6610XA - page 68

    68 Replacement Parts Table 5-1. Agilent 6610xA Power M odules Parts List - Electrical Reference Designators M odel Part Number Description 66101A 66101-61022 A SSEMBLY-POWER BOAR D 66102A 66102-61022 A SSEMBLY-POWER BOAR D 66103A 66103-61022 A SSEMBLY-POWER BOAR D 66104A 66104-61022 A SSEMBLY-POWER BOAR D 66105A 66105-61022 A SSEMBLY-POWER BOAR D 6 ...

  • Agilent Technologies 6610XA - page 69

    Replacement Parts 69 Table 5-1. Agilent 6610xA Power M odules Parts List - Electrical (continued) Reference Designators M odel Part Number Description C303 66101A 0180-4398 C AP 470uF 63V 66102A 0180-4400 CA P 220uF 63V 66103A 0180-4397 CA P l00uF 63V 66104A 0180-3649 CA P 47uF l00VDC 66105A 0180-3648 CA P l0uF 250V 66106A 0180-3169 CA P 4.7uF 250V ...

  • Agilent Technologies 6610XA - page 70

    70 Replacement Parts Table 5-1. Agilent 6610xA Power M odules Parts List - Electrical (continued) Reference Designators M odel Part Number Description C332, C333 All Models 0160-5422 C AP .047uF 20% C334 All Models 0160-4807 C AP 33pF 5% 100V C335 66101A 0160-4831 C AP 4700pF 10% 66102A- 66106A 0160-4830 CA P 2200pF 10% C336 66101A , 66102A 0160-47 ...

  • Agilent Technologies 6610XA - page 71

    Replacement Parts 71 Table 5-1. Agilent 6610xA Power M odules Parts List - Electrical (continued) Reference Designators M odel Part Number Description C433 All Models 0160-4791 C AP l0pF 5% 100V C434, C435 All Models 0160-5422 C AP .047uF 20% D201-D204 All Models 1901- 1087 DIODE-PW R RECT D205, D206 All Models 1901-1214 DIODE-PWR RECT D207, D208 A ...

  • Agilent Technologies 6610XA - page 72

    72 Replacement Parts Table 5-1. Agilent 6610xA Power M odules Parts List - Electrical (continued) Reference Designators M odel Part Number Description L302, L 303 All Models 5080-2219 CHOKE-OUTPUT L304 66101A -66103A 9140-1064 CHOKE- OUT PUT 66104A- 66106A 5080-2252 CHOKE-OUTPUT L305, L 306 66101A 5080-2251 BEAD-FERRIT E 66102A- 66106A Not Used L30 ...

  • Agilent Technologies 6610XA - page 73

    Replacement Parts 73 Table 5-1. Agilent 6610xA Power M odules Parts List - Electrical (continued) Reference Designators M odel Part Number Description R29 All Models 0698-0082 RES 464 1% .125W R201, R202 All Models 0764-0045 R ES 22K 5% 2W Mo R203 All Models 0698-3430 R ES 21.5 1% .125W R204 All Models 0757-0403 R ES 121 1% .125W R205 All Models 06 ...

  • Agilent Technologies 6610XA - page 74

    74 Replacement Parts Table 5-1. Agilent 6610xA Power M odules Parts List - Electrical (continued) Reference Designators M odel Part Number Description R305 66101A 0757-0441 R ES 8.25K 1% 66102A 0757-0449 RES 20K 1% .125W 66103A 0757-0123 RES 34.8K 1% 66104A 0698-3572 RES 60.4K 1% 66105A 0757-0467 RES 121K 1% 66106A 0757-0472 RES 200K 1% R306 66101A ...

  • Agilent Technologies 6610XA - page 75

    Replacement Parts 75 Table 5-1. Agilent 6610xA Power M odules Parts List - Electrical (continued) Reference Designators M odel Part Number Description R316 All Models 0698-8827 R ES lM 1% .125W R317 All Models 0757-0472 R ES 200K 1% R318 All Models 0757-0349 R ES 22.6K 1% R319, R320 All Models 0699-2246 R ES 25K .05% R321 All Models 0699-2248 R ES ...

  • Agilent Technologies 6610XA - page 76

    76 Replacement Parts Table 5-1. Agilent 6610xA Power M odules Parts List - Electrical (continued) Reference Designators M odel Part Number Description R334 66101A -66103A 0698-7933 RES 3.83K .1% 66104A 0698-8607 RES 4.5K .1% 66105A 0698-7933 RES 3.83K .1% 66106A 0698-8607 RES 4.5K .1% R336 66101A -66103A 0699-3417 RES 3.85K .lW 66104A 0699-3449 RES ...

  • Agilent Technologies 6610XA - page 77

    Replacement Parts 77 Table 5-1. Agilent 6610xA Power M odules Parts List - Electrical (continued) Reference Designators M odel Part Number Description R348 66101A , 66102A 0757-0441 RES 8.25K 1% 66103A, 66104A 0757-0444 RES 12.1K 1% 66105A 0698-3136 RES 17.8K 1% 66106A 0698-3159 RES 26.1K 1% R349 All Models 0757-0472 R ES 200K 1% R350 66101A -66105 ...

  • Agilent Technologies 6610XA - page 78

    78 Replacement Parts T able 5-1. A gilent 6610x A Po w er M odules Parts List - Electrical (continued) Reference Designators M odel Part Number Description R420 66101 A , 66102A 0698 - 6358 RES 100K .1% 66103A 0699 - 2248 RES 47.5K .05% 66104A 0698 - 6358 RES 100K .1% 66105 A , 66106A 0699 - 2246 RES 25K .05% R421 A ll Models 0698 - 3155 RES 4.64K ...

  • Agilent Technologies 6610XA - page 79

    Replacement Parts 79 T able 5-1. A gilent 6610x A Po w er M odules Parts List - Electrical (continued) Reference Designators M odel Part Number Description U203 A ll Models 1826 - 2075 IC UC3825N U204 A ll Models 1990 -15 02 OP T O ISOL A T OR U205 A ll Models 1858 - 0069 T RANSIS T OR ARRAY 18 P -DIP U206 A ll Models 1826 - 0175 IC 319 U301 66101 ...

  • Agilent Technologies 6610XA - page 80

    80 Replacement Parts Table 5-1. Agilent 6610xA Power M odules Parts List - Electrical (continued) Reference Designators M odel Part Number Description R501 All Models 1810-0405 NETWORK RES SIP R502 All Models 1810-0405 NETWORK RES SIP R503 All Models 1810-0405 NETWORK RES SIP R504 All Models 1810-0405 NETWORK RES SIP R505 All Models 1810-0636 NETWO ...

  • Agilent Technologies 6610XA - page 81

    Replacement Parts 81 Table 5-3. Ou tput Connector A ssembly Parts List Reference Designators Part Number Description 5060-3470 ASSEMBL Y-OUT P UT CONNECT OR B OARD C602, C603 0160-5422 CA P .047uF 20% C604 0160-4281 C AP 2200pF 20% C605 1810-1379 NETWORK-CAP SIP J601 1251-8410 CONNECTOR, TO P OWER BOARD J602, J603 1252-4311 CONNECTOR, TO CONNECT OR ...

  • Agilent Technologies 6610XA - page 82

    ...

  • Agilent Technologies 6610XA - page 83

    Diagrams 83 6 Diagrams This chapte r contains t est point an d component location diagram s and s chemat ics for troubl eshooting the Ag ilent 6610xA Pow er Modules. SHOCK HAZA RD Hazard o us voltages are present througho ut the Power and Bias boa r d assemblies. Ac line voltage is present on some con nectors even when the modu le is not t urned on ...

  • Agilent Technologies 6610XA - page 84

    84 Diagrams Schematic Notes Notes that apply to all schematic sheets are as follow s: þ All resistors are in oh ms +/-1%, 1/8 W, unless otherw ise specified. þ All capacitors are in m icrofarads un less otherwise specif ied. þ Refer to the parts list (Table 5-1) f or the values of the resistors an d capacitors that are enclosed by a h eavy recta ...

  • Agilent Technologies 6610XA - page 85

    ...

  • Agilent Technologies 6610XA - page 86

    ...

  • Agilent Technologies 6610XA - page 87

    L305 L306 L307 L308 R309 ...

  • Agilent Technologies 6610XA - page 88

    ...

  • Agilent Technologies 6610XA - page 89

    ...

  • Agilent Technologies 6610XA - page 90

    S3 S2 S1 S0 N10 CR505 R509 R508 1 8 R507 3 6 R507 2 7 U502 15 16 1 9 8 3 6 12 4 14 13 11 10 2 5 7 U503 7 5 2 10 11 13 14 4 12 6 3 8 9 1 16 15 J501 10 1 3 2 9 8 7 6 5 4 C503 R510 C502 R501 8 1 R501 2 7 R501 6 3 R501 4 5 R502 1 8 R502 7 2 R502 3 6 R502 5 4 R505 2 7 R505 6 3 R505 4 5 R506 8 1 R506 2 7 D509 D502 6 7 8 9 10 4 3 2 1 5 D503 5 1 2 3 4 10 9 ...

  • Agilent Technologies 6610XA - page 91

    ...

  • Agilent Technologies 6610XA - page 92

    ...

  • Agilent Technologies 6610XA - page 93

    ...

  • Agilent Technologies 6610XA - page 94

    1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 I F 0 - I SENSE + OUT - OUT ...

  • Agilent Technologies 6610XA - page 95

    XY XY XY C1 8.1 2.2 C220 0.5 2.1 C331 12.7 3.7 C2 8.1 2.0 C221 1.0 3.2 C332 13.7 3.6 C3 8.1 3.1 C222 0.0 2.9 C333 13.4 4.1 C4 7.3 3.0 C223 1.0 2.1 C334 13.2 3.8 C5 8.5 3.4 C224 0.0 2.4 C335 10.9 3.7 C6 7.9 2.1 C225 2.3 3.7 C336 12.2 3.9 C7 9.1 3.7 C226 3.2 3.3 C337 14.2 3.3 C8 9.1 3.6 C227 11.3 2.3 C338 14.9 4.1 C9 9.7 4.0 C228 0.5 2.0 C339 15.4 4. ...

  • Agilent Technologies 6610XA - page 96

    ...

  • Agilent Technologies 6610XA - page 97

    Manual Backdating This app e nd ix describes the changes that must be made to this manual to m ake it co mply w ith module serial numbers lower than those on the title page. Look for the serial number of your m odule on the table and make only those changes listed for that serial num ber. A gilent Model Pref ix Number Serial Number Make Changes A g ...

  • Agilent Technologies 6610XA - page 98

    CHANGE 8: In the part s list on page 65, change L204 thro ugh L 211 from part num ber 5080-2251 to 9170- 0442. CHANGE 9: On page 67, ch ange R204, R 214 to 61.8 ohms , part num ber 0757-0397. On page 65, del ete D216, D217, part nu mber 1901-1214. CHANGE 10: Indicate that softw are revision A.00.01 applies to th ese and earlier models. CHANGE 11: I ...

  • Agilent Technologies 6610XA - page 99

    Index B backdating.................................................................................................................................................................... 89 C compon ent locator ............................................................................................................................................... ...

  • Agilent Technologies 6610XA - page 100

    perform ance tests ......................................................................................................................................................... 11 program ming values - m odules .................................................................................................................................... 12 R revis ...

  • Agilent Technologies 6610XA - page 101

    cv accuracy ........................................................................................................................................................... 42 DAC ..................................................................................................................................................................... 45 dow np ...

Manufacturer Agilent Technologies Category Ventilation Hood

Documents that we receive from a manufacturer of a Agilent Technologies 6610XA can be divided into several groups. They are, among others:
- Agilent Technologies technical drawings
- 6610XA manuals
- Agilent Technologies product data sheets
- information booklets
- or energy labels Agilent Technologies 6610XA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Agilent Technologies 6610XA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Agilent Technologies 6610XA, service manual, brief instructions and user manuals Agilent Technologies 6610XA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Agilent Technologies 6610XA.

A complete manual for the device Agilent Technologies 6610XA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Agilent Technologies 6610XA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Agilent Technologies 6610XA.

A complete Agilent Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Agilent Technologies 6610XA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Agilent Technologies 6610XA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Agilent Technologies 6610XA, that we can find in the current document
3. Tips how to use the basic functions of the device Agilent Technologies 6610XA - which should help us in our first steps of using Agilent Technologies 6610XA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Agilent Technologies 6610XA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Agilent Technologies 6610XA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Agilent Technologies 6610XA?

Use the form below

If you did not solve your problem by using a manual Agilent Technologies 6610XA, ask a question using the form below. If a user had a similar problem with Agilent Technologies 6610XA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)