    C ISCO S YSTEMS P UBLICATION H ISTORY 170 W EST T ASMAN D R S AN J OSE , CA, 95134 R EV A.16 O CTOBER 9, 2012 WWW . CISCO . COM Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) ...

  • Cisco Systems A03D1TBSATA - page 2

    Cisco UCS C220 M3 High-Dens ity Rac k Serv er (Small Form Factor Disk D rive Model) 2 CONTENTS OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Chassis Front View . . . . . . . . . . . . . . ...

  • Cisco Systems A03D1TBSATA - page 3

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) OVERVIEW 3 OVER VIEW The Ci sco® UC S C220 M3 rack server is des igned f or performance and density over a wide range of business workloads from web serving to distributed database. Building on the success of the Cisc o UCS C200 M2 rack server , the ente rpri ...

  • Cisco Systems A03D1TBSATA - page 4

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 4 DETAILED VIEWS DET AILED VIEWS Chassis Front Vi ew Figure 2 shows the Cisco UCS C220 M3 Hig h -Density SFF Rack Server . Figure 2 Chassis Front V iew For more information about th e KVM cable connection, see KVM CAB LE, page 58 . 1 P ower button/power stat ...

  • Cisco Systems A03D1TBSATA - page 5

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) DETAILED VIEWS 5 Chassis Rear Vi ew Figure 3 shows the externa l features of the r ear panel. Figure 3 Chassis Rear V iew 1 P ower supplies (up to two) 6 One 10/100/1000 Ethernet dedicated management port 2 Slot 2: Low-profile PCIe slot on riser: (half-height, ...

  • Cisco Systems A03D1TBSATA - page 6

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 6 BASE SERVER STANDARD CA PABILITIES and FEATURES BASE SER VER ST ANDARD CA P ABILITIES and FEA TURES Ta b l e 1 lists the capabilities and features of the base server . Details abou t how to configure the server for a particular feature or capability (f or ...

  • Cisco Systems A03D1TBSATA - page 7

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) BASE SERVER STANDARD CAPABILITIES an d FEATURES 7 Storage controller ■ Embedded RAID (3 Gbs) • Embedded SA T A-only RAID controller , supporting up to 4 SA T A-only drives (RAID 0, 1, 10) • ROM5 embedded RAID upgrade, supporting up to 8 SAS/SA T A drives ...

  • Cisco Systems A03D1TBSATA - page 8

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 8 BASE SERVER STANDARD CA PABILITIES and FEATURES Fans Chassis: ■ Five hot-swappable fans for front-to-r ear cooling Po w e r s u p p l y : ■ Each power supply is equipped with a fan. Integrated management processor Cisco Integrated Management Controller ...

  • Cisco Systems A03D1TBSATA - page 9

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 9 CONFIGURING the SER VER Follow these steps to configure the Cisco UCS C220 M3 High-Density SFF Rack Server: ■ STEP 1 VERIFY SERVER SKU, page 10 ■ STEP 2 SELECT CPU(s), page 11 ■ STEP 3 SELECT MEMOR Y , page 13 ■ STEP 4 SELECT R ...

  • Cisco Systems A03D1TBSATA - page 10

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 10 CONFIGURI NG the SERVER STEP 1 VERIFY SER VER SKU V erify the product ID (PID) of the server as show n in Ta b l e 2 . The Cisco C220 M3 server: ■ Includes one tool-less rail kit ■ Does not include power supply , CPU, memory , ha rd disk drives (HDDs) ...

  • Cisco Systems A03D1TBSATA - page 11

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 11 STEP 2 SELECT CPU(s) The standa rd CPU fea tures are: ■ Intel E5-2600 series processo r family CPUs ■ Intel C600 series chipset ■ Cache size of 10, 15, or 20 MB Select CPUs The available CPUs are listed in Ta b l e 3 . T able 3 ...

  • Cisco Systems A03D1TBSATA - page 12

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 12 CONFIGURI NG the SERVER Approved Configurations (1) 1-CPU conf igurations: ■ Select any one CPU listed in Ta b l e 3 . (2) 2-CPU Configur ations: ■ Select two identical CPUs fr om any one of the rows of Ta b l e 3 on page 11 . Caveats ■ Y ou can sel ...

  • Cisco Systems A03D1TBSATA - page 13

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 13 STEP 3 SELECT MEMOR Y The standar d memory feat ures are: ■ DIMMs — Clock speed: 1333 or 1600 MHz — Ranks per DIMM: 1, 2, or 4 — Operational voltage: dual v oltage capable (1.5 V or 1.35 V) — R egistered ECC DDR3 DIMMS (RDIM ...

  • Cisco Systems A03D1TBSATA - page 14

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 14 CONFIGURI NG the SERVER Select DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option. The available memory DIMMs and mi rroring option are listed in Ta b l e 4 . NOTE: When memory mirroring is e ...

  • Cisco Systems A03D1TBSATA - page 15

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 15 Approved Configurations (1) 1-CPU conf iguration wi thout memory mirroring: ■ Select from 1 to 8 DIMMs. Refer to Memory Population Rules, page 50 , for more detailed information. (2) 1-CPU configuration with memory mirroring: ■ Se ...

  • Cisco Systems A03D1TBSATA - page 16

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 16 CONFIGURI NG the SERVER (4) 2-CPU configuration with memory mirroring: ■ Select 2, 4, 6, or 8 identical DI MMs per CPU. The DIMMs will be placed by the factory as shown in the following table. ■ Select the memory mirroring opti on (N01-MMIRROR) as sho ...

  • Cisco Systems A03D1TBSATA - page 17

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 17 Caveats ■ The server supports registered DIMMs (RDIMMs ) or load-reduced DIMMS (LRDIMMs), however , do not mix RDIMMs and LRDIMMs in a server . ■ When using mirroring, DI MMs must be installed in identical pairs across paired DDR3 ...

  • Cisco Systems A03D1TBSATA - page 18

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 18 CONFIGURI NG the SERVER STEP 4 SELECT RAID CONFIGURA TION The RAID contr oller choi ces are: ■ Embedded RAID (on motherboard) ■ Mezzanine RAID controller cards ■ Plug-in PCIe RAID controller cards Cisco can provide factory-co nfigured RAID system s ...

  • Cisco Systems A03D1TBSATA - page 19

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 19 T able 6 Available Mezzanine Card RAID Options Product ID (PID) PID Des cri ption RAID Controllers UCSC-RAID-11-C220 Cisco UCSC RAID SAS 2008M-8i Mez zanine Card (RAID 0, 1, 10, 5, and 50 supported), operating at 6 Gbs. ■ Supports u ...

  • Cisco Systems A03D1TBSATA - page 20

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 20 CONFIGURI NG the SERVER RAID Configur ation Options R2XX-RAID0 Factory preconfigu red RAID striping option Enable RAID 0 Setting. R equires a minimum of one hard drive. R2XX-RAID1 Factory preconfigu red RAID mirror ing option Enable RAID 1 Setting. R equi ...

  • Cisco Systems A03D1TBSATA - page 21

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 21 Approved Configurations (1) 1-CPU Configur ations Mezzanine cards are not supported for 1-CPU config urations, Therefore, only the following RAID controllers are supported for single-CPU configurations: ■ Embedded RAID ■ LSI MegaR ...

  • Cisco Systems A03D1TBSATA - page 22

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 22 CONFIGURI NG the SERVER STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID ST A TE DRIVES (SSDs) The standard disk drive features are: ■ 2.5-inch small form factor ■ Hot-pluggable ■ Sled-mounted Select Drives The available drives are listed in Ta b l e ...

  • Cisco Systems A03D1TBSATA - page 23

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 23 Approved Configurations (1) Onboard RAID, Mezzani ne Cards, and all Plug-In RAID Controllers ■ If you have not selected an onboard RAID upgrade option (ROM5 or RO M55), a mezzanine card, or a plug-in RAID controller , you may select ...

  • Cisco Systems A03D1TBSATA - page 24

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 24 CONFIGURI NG the SERVER STEP 6 SELECT PCIe OPTION CARD(s) The standard PCie ca rd offerings are: ■ Converged Network Adapters (CNAs) ■ Network Interface Cards (NICs) ■ Host Bus Adapters (HBAs) Select PCIe Option Cards The available PCIe option cards ...

  • Cisco Systems A03D1TBSATA - page 25

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 25 Approved Configurations (1) No RAID controller plug-in card ■ If you did not c hoose a plug-i n RAID controlle r (for example, you are using embedded RAID or a mezzanine RAID controller ), you can select up to two PC ie option cards ...

  • Cisco Systems A03D1TBSATA - page 26

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 26 CONFIGURI NG the SERVER STEP 7 ORDER OPTIONAL NETWOR K CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server . Choose Optional T w inax Cables Ta b l e 10 list ...

  • Cisco Systems A03D1TBSATA - page 27

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 27 Choose Optional SFP Modules Optical Cisco SFP+ mo dules are listed in Ta b l e 11 . Approved Configurations (1) Choose Up to T wo SFP+ Modul es for Each Network Card Ordered ■ Y ou may choos e one or two SFP+ optical module s cables ...

  • Cisco Systems A03D1TBSATA - page 28

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 28 CONFIGURI NG the SERVER Figure 5 Network Card Connections ...

  • Cisco Systems A03D1TBSATA - page 29

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 29 STEP 8 ORDER POWER SUPPL Y The C220 M3 SFF server accommodates two power supplies. A lightly loaded server can operate from one 650 W power supply . A fully lo aded server might need to be powered with two 450 W or two 650 W power sup ...

  • Cisco Systems A03D1TBSATA - page 30

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 30 CONFIGURI NG the SERVER STEP 9 SELECT AC POWER CORD(s) Using Ta b l e 13 , select the appropriate AC power cords. Y ou can select a minimum of no power cords and a maximum of two. If you select th e option R2XX-DMYMPWRCORD, no power cord is shipped with t ...

  • Cisco Systems A03D1TBSATA - page 31

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 31 SFS-250V -10A-AR P ower Cord, SFS, 250V , 10A, Argentina CAB-9K10A-AU P ower Cord, 250V AC 10A 3112 Plug, Australia SFS-250V -10A-CN P ower Cord, SFS, 250V , 10A, China CAB-250V -10A-CN AC P ower Cord - 250V , 10A - PRC CAB-9K10A-EU P ...

  • Cisco Systems A03D1TBSATA - page 32

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 32 CONFIGURI NG the SERVER CAB-9K10A-IT P ower Cord, 250V AC 10A CEI 23-16/VII Plug, Italy CAB-9K10A-SW P ower Cord, 250V AC 10A MP232 Plug, Switzerland CAB-9K10A-UK P ower Cord, 250V AC 10A BS1363 Plug (13 A fuse), UK CAB-9K12A-NA P ower Cord, 125V AC 13A N ...

  • Cisco Systems A03D1TBSATA - page 33

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 33 STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM The reversible cable management ar m mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use Ta b l e 14 to order a cable ma ...

  • Cisco Systems A03D1TBSATA - page 34

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 34 CONFIGURI NG the SERVER STEP 11 ORDER A TRUSTED PLA TFORM MODULE T rusted Platform Module (TPM) is a computer ch ip (microcontroller) that can secure ly store artifacts used to authenticate the platform (server). These ar tifacts can inc lude passwords, c ...

  • Cisco Systems A03D1TBSATA - page 35

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 35 STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) Y ou can order one op tional 16 GB Cisco Flexible Flash secure digital (SD) card. Thi s SD card contains preloaded software for si mplified server operation. The ordering in ...

  • Cisco Systems A03D1TBSATA - page 36

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 36 CONFIGURI NG the SERVER STEP 13 ORDER OPTIONAL USB 2.0 DRIVE Y ou may order one optional USB 2.0 drive. The USB driv e ordering information is li sted in Ta b l e 17 . See Figure 6 on page 47 for the location of the USB connector . T able 17 USB 2.0 Drive ...

  • Cisco Systems A03D1TBSATA - page 37

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 37 STEP 14 SELECT OPERA TING SYSTEM Several operating systems are available from wh ich to choose. Select one of the operating systems shown in Ta b l e 18 . T able 18 Operating Systems PID Description Product ID (PID) SUSE Linux Enterpr ...

  • Cisco Systems A03D1TBSATA - page 38

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 38 CONFIGURI NG the SERVER VMW -VS5-STD-3A VMware vSphere 5 Standard for 1 P rocessor , 3 Y ear , Support R equired VMW -VS5-STD-4A VMware vSphere 5 Standard for 1 P rocessor , 4 Y ear , Support R equired VMW -VS5-STD-5A VMware vSphere 5 Standard for 1 P roc ...

  • Cisco Systems A03D1TBSATA - page 39

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 39 STEP 15 SELECT OPERA TING SYSTEM MEDIA KIT Select the optional operating system media listed in Ta b l e 19 . Ta b l e 1 9 O S M e d i a Product ID (PID) PID Description RHEL-6 RHEL 6 R ecovery Media Only (Multilingual) SLES-11 SLES 1 ...

  • Cisco Systems A03D1TBSATA - page 40

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 40 CONFIGURI NG the SERVER STEP 16 SELECT OPTIONAL V A LUE-ADDED SOFTW ARE Y ou can select from a variety of value -added software listed i n Ta b l e 20 . T able 20 V alue Added Software Product ID (PID) PID Description BMC-SE-4C BMC BladeLogi c Standar d E ...

  • Cisco Systems A03D1TBSATA - page 41

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 41 STEP 17 SELECT SER VICE and SUPPOR T LEVEL A variety of service opti ons are available, as des cribed in this section. Unified Computing W arranty , No Contract If you have noncritical implemen tations and choose no ser vi ce contra c ...

  • Cisco Systems A03D1TBSATA - page 42

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 42 CONFIGURI NG the SERVER Unified Computing W arranty Plus Service For faster parts replacement than is provided wi th the standard Cisco Un ified Computing System warranty , Cisco offers the Cisco Unified Computin g W arranty Plus Service. Y ou can choose ...

  • Cisco Systems A03D1TBSATA - page 43

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 43 Mission Critical Support Service This service delivers personalized technical account management, expe dited technical support, and expert field support engineering for the Cisco Uni fied Computing System (U CS). The Mission Critic al ...

  • Cisco Systems A03D1TBSATA - page 44

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 44 CONFIGURI NG the SERVER Mission Critical Support Servic e is a layered serv ice av ailable for all C isc o data center products already support by a UCS Support Se rvice or SMAR Tnet service contract. For further information about Cisco Mi ssion Critical ...

  • Cisco Systems A03D1TBSATA - page 45

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) OPTIONAL STEP - ORDE R RACK(s) 45 OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cis co for the C-Series servers, including the C220 M3 SFF server . This rack is a standard 19-inch rack and can be ordered with a variety of options, as ...

  • Cisco Systems A03D1TBSATA - page 46

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 46 OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is avai lable from Cisco for the C-Series rack serve rs, including theC220 M3 server . This PDU is availa ble in a zero rac k unit (RU) style (see Ta b l e 24 ). ...

  • Cisco Systems A03D1TBSATA - page 47

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 47 SUPPLEMENT AL MA TERIAL CHASSIS An internal view of the C220 M3 chassis with the top co ver removed is shown in Figure 6 . Figure 6 C220 M3 SFF With T op Cover Off 1 Drives (hot-swappable, accessed through front panel) 10 T rusted plat ...

  • Cisco Systems A03D1TBSATA - page 48

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 48 SUPPLEMENTAL MATERI AL CPUs and DIMMs Physical Layout Each CPU has four DIMM channels: ■ CPU1 has channels A, B, C, and D ■ CPU2 has channels E, F , G, and H Each DIMM channel has two banks: bank 1 a nd bank 2. The b lue-colored DIMM banks are fo r ba ...

  • Cisco Systems A03D1TBSATA - page 49

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 49 Figure 7 Physical Layout of CPU DIMM Channels and Banks C1 C2 D1 D2 B2 B1 A2 A1 G1 G2 H2 H1 F2 F1 E1 E2 Front of Server CPU1 CPU2 331707 ...

  • Cisco Systems A03D1TBSATA - page 50

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 50 SUPPLEMENTAL MATERI AL Memory P opulation Rules When considering the memory config uration of your server , you should consider the following items: ■ For optimum performance, popul ate at leas t one DIMM per memory channel per CPU. If using 4 GB DIMMs, ...

  • Cisco Systems A03D1TBSATA - page 51

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 51 Recommended Memory Configur ation This section ex plains the reco mmended DIMM population order rules for the C220 M3 server . ■ All DIMMs must be DDR3 DIMM s. ■ Do not mix: — DIMMs with different sizes or clock rates in a bank ? ...

  • Cisco Systems A03D1TBSATA - page 52

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 52 SUPPLEMENTAL MATERI AL 192 GB 4x16 GB 2x 16 GB 4x16 GB 2x16 GB 1600 12 4x16 GB 4x8 GB 4x16 GB 4x8 GB 160 0 16 2x32 GB 1x32 GB 2x32 GB 1x 32 GB 1600 6 256 GB 4x16 GB 4x 16 GB 4x16 GB 4x16 GB 1600 16 2x32 GB 2x32 GB 2x32 GB 2x 32 GB 1600 8 512 GB 4x32 GB 4x ...

  • Cisco Systems A03D1TBSATA - page 53

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 53 Supported DIMM P opulations The supported DIMM populations are listed in Ta b l e 28 . T able 28 Supported DIMM Configurati ons CPU 1 DIMMs T otal DIMMs for CPU 1 CPU 1 Capacity CPU 2 DIMMs To t a l D I M M s for CPU 2 CPU 2 Capacity T ...

  • Cisco Systems A03D1TBSATA - page 54

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 54 SUPPLEMENTAL MATERI AL Low-V oltag e DIMM Consider ations The C220 M3 server can be ordered with dual-volta ge (1.5/1.35 V) DIMMs o nly . Note the following consideratio ns: ■ Low-voltage DIMMs within the server must ha ve the identical manufacturer , t ...

  • Cisco Systems A03D1TBSATA - page 55

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 55 RACKS The Cisco R42610 rack (see Figure 8 ) is certified for Cisco UCS instal lation at customer sites and is suitable for the following equipment: ■ Cisco UCS B-Series servers and fa bric interc onnects ■ Cisco UCS C-Series and se ...

  • Cisco Systems A03D1TBSATA - page 56

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 56 SUPPLEMENTAL MATERI AL Figure 8 Cisco R4 2610 Rack Front view - door closed Front view - door open Front view - door removed ...

  • Cisco Systems A03D1TBSATA - page 57

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 57 PDUs Cisco RP Series P ower Distribution Units (PDUs) offer power distribution with branch circuit protection. Cisco RP Series PDU models distri bute power to up to 24 outlets. The ar chit ec ture orga nize s powe r distribution, simpl ...

  • Cisco Systems A03D1TBSATA - page 58

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 58 SUPPLEMENTAL MATERI AL KVM CABLE The KVM cable provides a connection into the server , providing a DB9 se rial connector , a VGA c onnector for a monitor , and dual USB ports for a keyboard and mo use. With this cable, you can create a direct connection t ...

  • Cisco Systems A03D1TBSATA - page 59

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 59 Motherboard USB and SD P orts, and RAID Card Backup Location The C220 M3 SFF motherboard has a general-purpose USB socket, an d two SD so ckets as shown in Figure 11 . The mounting location for the RAID SuperCap da ta cache power backu ...

  • Cisco Systems A03D1TBSATA - page 60

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 60 TECHNICAL SPECIFIC ATIONS TECHNICAL SPECIFICA TIONS Dimensions and Weight P ower Specifications The general power specifications for the C220 M3 SF F server 450 W power supply are listed in Ta b l e 32 . T able 31 UCS C220 M3 Dimensions and Weight Pa r a ...

  • Cisco Systems A03D1TBSATA - page 61

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) TECHNICAL SPECIFICATIONS 61 The general power specifications for the C220 M3 SF F server 650 W power supply are listed in Ta b l e 32 . For configuration-specif ic power specifications, use the Cisco UCS P ower Ca lculator at this URL: https://express.salire.c ...

  • Cisco Systems A03D1TBSATA - page 62

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 62 TECHNICAL SPECIFIC ATIONS Env ironmental Specifications The power specifications for the C220 M3 server are listed in Ta b l e 34 . T able 34 UCS C220 M3 Env ironmental Specifications Pa r a m e t e r Minimum T emperature operating 41 to 104° F (5 to 40 ...

  • Cisco Systems A03D1TBSATA - page 63

    Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) TECHNICAL SPECIFICATIONS 63 Compliance Requirements The regulatory compliance requirements for C-Series servers are listed in Ta b l e 35 . T able 35 UCS C-Series Regul atory Compliance Requirements Pa r a m e t e r Description R egulatory Compliance P roducts ...

  • Cisco Systems A03D1TBSATA - page 64

    Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 64 TECHNICAL SPECIFIC ATIONS ...

Manufacturer Cisco Systems Category Server

Documents that we receive from a manufacturer of a Cisco Systems A03D1TBSATA can be divided into several groups. They are, among others:
- Cisco Systems technical drawings
- A03D1TBSATA manuals
- Cisco Systems product data sheets
- information booklets
- or energy labels Cisco Systems A03D1TBSATA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cisco Systems A03D1TBSATA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cisco Systems A03D1TBSATA, service manual, brief instructions and user manuals Cisco Systems A03D1TBSATA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cisco Systems A03D1TBSATA.

A complete manual for the device Cisco Systems A03D1TBSATA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cisco Systems A03D1TBSATA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cisco Systems A03D1TBSATA.

A complete Cisco Systems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cisco Systems A03D1TBSATA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cisco Systems A03D1TBSATA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cisco Systems A03D1TBSATA, that we can find in the current document
3. Tips how to use the basic functions of the device Cisco Systems A03D1TBSATA - which should help us in our first steps of using Cisco Systems A03D1TBSATA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cisco Systems A03D1TBSATA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Cisco Systems A03D1TBSATA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Cisco Systems A03D1TBSATA?

Use the form below

If you did not solve your problem by using a manual Cisco Systems A03D1TBSATA, ask a question using the form below. If a user had a similar problem with Cisco Systems A03D1TBSATA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)