    INST ALLA TION INSTRUCTIONS 69-1790-3 U.S. Pat. No. 6595430, D50 9151, and Othe r Patents Pending TCONT802AS32DA T ouch Screen and TCONT803AS32DA T ouch Screen with Dehumidification Control Comfort Controls 18-HD25D19-3 APPLICA TION The TCONT80 2AS32DA and T CONT803AS32 DA T ouch Screen Comfor t Controls prov ide electronic co ntrol of 24 Vac heati ...

  • Trane TCONT803AS32DA - page 2

    TCONT802AS32DA T OUCH SCREEN AND TCO NT803AS32 DA T OUCH SCREEN WITH DEHUMID IFICATION Pub. No. 18-HD2 5D19-3 69-1790—3 2 Do not install the com fort control whe re it can be affected by: — Drafts or dead spots behind doors and in corners. — Hot or c old air fr om duct s. — Radiant heat from sun or appli ances. — Concealed pipe s and chim ...

  • Trane TCONT803AS32DA - page 3

    TCONT802AS32DA T OUCH SCREEN AND TCON T803AS32DA T OUCH SCREEN WITH DEHUMIDIFICATI ON Pub. No. 18-HD25D19-3 3 69-1790—3 Fig. 5. T ypical hookup of singl e-st age heat and cool system with sing le transformer (1H/1C). Fig. 6. T ypical hookup of singl e-st age heat and cool system with two transf ormers (1H/1 C). Fig. 7. T ypical hookup of two-s ta ...

  • Trane TCONT803AS32DA - page 4

    TCONT802AS32DA T OUCH SCREEN AND TCO NT803AS32 DA T OUCH SCREEN WITH DEHUMID IFICATION Pub. No. 18-HD2 5D19-3 69-1790—3 4 Fig. 9. T yp ical hooku p of single-s tage heat pump with a uxiliary/backup heat (2H/1C h eat pump). Fig. 10. T ypi cal hookup of mul tist age heat pump with auxi liary/backup heat (3 H/2C heat p ump). PM-A 1 M22641 FACT ORY I ...

  • Trane TCONT803AS32DA - page 5

    TCONT802AS32DA T OUCH SCREEN AND TCON T803AS32DA T OUCH SCREEN WITH DEHUMIDIFICATI ON Pub. No. 18-HD25D19-3 5 69-1790—3 Fig. 11. T ypical hookup of multistage two-st ep scroll heat p ump with a uxiliary/back up heat (3H /2C heat pump). Fig. 12. T ypica l hookup of sing e-stage heat pu mp with non-va riable spee d gas furnace. 1 M24230 FACT ORY IN ...

  • Trane TCONT803AS32DA - page 6

    TCONT802AS32DA T OUCH SCREEN AND TCO NT803AS32 DA T OUCH SCREEN WITH DEHUMID IFICATION Pub. No. 18-HD2 5D19-3 69-1790—3 6 Fig. 13. T ypica l hookup of si ngle-st age heat pump with two st age variable spee d gas furnace (2H/1C heat pump). W1 W2 G YB / C R T 1 1 2 FACT ORY INST ALLED JUMPER. OUTDOOR REMOTE SENSOR. WIRES MUST HA VE A CABLE SEP ARAT ...

  • Trane TCONT803AS32DA - page 7

    TCONT802AS32DA T OUCH SCREEN AND TCON T803AS32DA T OUCH SCREEN WITH DEHUMIDIFICATI ON Pub. No. 18-HD25D19-3 7 69-1790—3 Fig. 14. T ypical hookup of multi sta ge heat pump with two sta ge variabl e speed gas furnace (3 H/2C heat pump). W1 W2 G Y/Y 2 B/C R T 1 1 2 FACT ORY INST ALLED JUMPER. OUTDOOR REMOTE SENSOR. WIRES MUST HA VE A CABLE SEP ARATE ...

  • Trane TCONT803AS32DA - page 8

    TCONT802AS32DA T OUCH SCREEN AND TCO NT803AS32 DA T OUCH SCREEN WITH DEHUMID IFICATION Pub. No. 18-HD2 5D19-3 69-1790—3 8 Fig. 15. T ypic al hookup of multist age two-step scroll heat pump with t wo st age variable speed gas f urnace (3H/2C heat pump). Powering the Comfort Control The Comfor t Contr ol can be po wered wit h 24 V ac. 24 V ac Commo ...

  • Trane TCONT803AS32DA - page 9

    TCONT802AS32DA T OUCH SCREEN AND TCON T803AS32DA T OUCH SCREEN WITH DEHUMIDIFICATI ON Pub. No. 18-HD25D19-3 9 69-1790—3 Mounting the Comfort Con trol 1. Align the terminal screw blocks with th e pins on the back of th e comfort control. 2. Push the c omfort c ontrol st raight o nto the wallplate . See Fig. 17. Fig. 17. Mo unting com fort cont rol ...

  • Trane TCONT803AS32DA - page 10

    TCONT802AS32DA T OUCH SCREEN AND TCO NT803AS32 DA T OUCH SCREEN WITH DEHUMID IFICATION Pub. No. 18-HD2 5D19-3 69-1790—3 1 0 OPERA TION System and Fan Settings The System default set ting is Heat and the Fa n default setting is Auto. SYSTEM SE TTINGS Heat: cont rols heat ing syste m. Off: heating a nd coolin g are of f. Cool: controls co oling sys ...

  • Trane TCONT803AS32DA - page 11

    TCONT802AS32DA T OUCH SCREEN AND TCON T803AS32DA T OUCH SCREEN WITH DEHUMIDIFICATI ON Pub. No. 18-HD25D19-3 1 1 69-1790—3 INST ALLER SETUP The comfort control works with ma ny different system types. T o operate correctly , the comfort control must be set up to oper ate the installed hea ting and/or coolin g system. Follow these steps to enter th ...

  • Trane TCONT803AS32DA - page 12

    TCONT802AS32DA T OUCH SCREEN AND TCO NT803AS32 DA T OUCH SCREEN WITH DEHUMID IFICATION Pub. No. 18-HD2 5D19-3 69-1790—3 1 2 IMPORT ANT The Installer Setup Menu (T able 4) sh ows all the availab le options. The se options custo mize themselves as you make sele ctions to the I nstaller Setup. Theref ore, not all In staller Setup Selection s are sho ...

  • Trane TCONT803AS32DA - page 13

    TCONT802AS32DA T OUCH SCREEN AND TCON T803AS32DA T OUCH SCREEN WITH DEHUMIDIFICATI ON Pub. No. 18-HD25D19-3 13 69-1790—3 Cycles per hour (cph) for 1st St age Heat 0240 5 Heat Stage 1 cycles per hour (cp h) 1-12 1-12 availabl e; typic al settin gs: 1 —1 cph used fo r steam or gravity sy stem. 3 —3 cph used fo r 2-stage fossil fuel forced air s ...

  • Trane TCONT803AS32DA - page 14

    TCONT802AS32DA T OUCH SCREEN AND TCO NT803AS32 DA T OUCH SCREEN WITH DEHUMID IFICATION Pub. No. 18-HD2 5D19-3 69-1790—3 1 4 Deadband 0310 2 thru 9 Heating and coolin g setpoints can be set no closer than cho sen value: 2 —2°F (1°C) 3 —3°F (2°C) 4 —4°F (2.5°C) 5 —5°F (3°C) 6 —6°F (3.5°C) 7 —7°F (4°C) 8 —8°F (4.5°C) 9 ? ...

  • Trane TCONT803AS32DA - page 15

    TCONT802AS32DA T OUCH SCREEN AND TCON T803AS32DA T OUCH SCREEN WITH DEHUMIDIFICATI ON Pub. No. 18-HD25D19-3 15 69-1790—3 Adaptive Intelligent Recovery™ 0530 1 Adaptive Intelligent Recovery™ contro l is activated (system starts early so setpoint is reached by start of program per iod). 0 0 —conventional reco very (system starts recovery at p ...

  • Trane TCONT803AS32DA - page 16

    TCONT802AS32DA T OUCH SCREEN AND TCO NT803AS32 DA T OUCH SCREEN WITH DEHUMID IFICATION Pub. No. 18-HD2 5D19-3 69-1790—3 1 6 T emperature Control in Heat 0680 2 St a ndard tempe rature control in heat ing. 1, 3 1 —less agg ressive temperatur e control (could cause tem perature undershoo t) 3 —more aggressive temperatur e control (could cause t ...

  • Trane TCONT803AS32DA - page 17

    TCONT802AS32DA T OUCH SCREEN AND TCON T803AS32DA T OUCH SCREEN WITH DEHUMIDIFICATI ON Pub. No. 18-HD25D19-3 17 69-1790—3 SYSTEM CHECKOUT Installer System T est The Installer System T est mode is used to test the HVAC system(s). See T able 5. While in Syste m T est mode, minimum off-time for compres sors is bypassed. The Installer T est is part of ...

  • Trane TCONT803AS32DA - page 18

    TCONT802AS32DA T OUCH SCREEN AND TCO NT803AS32 DA T OUCH SCREEN WITH DEHUMID IFICATION Pub. No. 18-HD2 5D19-3 69-1790—3 1 8 ADVANCED FEATURES Outdoor or Indoo r T emperature Sensor For accuracy , the initial reading of the indoor and ou tdoor temperature se nsors require five minutes to stabilize. See the Sensor instr uctions for installation inf ...

  • Trane TCONT803AS32DA - page 19

    TCONT802AS32DA T OUCH SCREEN AND TCON T803AS32DA T OUCH SCREEN WITH DEHUMIDIFICATI ON Pub. No. 18-HD25D19-3 19 69-1790—3 T ROUBLESHOOTING (SEE T ABLE 6) T able 6. T roubleshooti ng. Symptom Possible Ca use Action Display does not co me on. Comfo rt contro l is not bei ng powered. Check for 24 Vac between B and Rc. T emperature setti ngs do not ch ...

  • Trane TCONT803AS32DA - page 20

    TCONT802AS32DA T OUCH SCREEN AND TCO NT803AS32 DA T OUCH SCREEN WITH DEHUMID IFICATION Pub. No. 18 -HD25D19-3 69-1790—3 M.S. Rev. 01-06 ® U.S. Regist ered Tradem ark © 2006 Ameri can Standar d Inc. All Rights Reserved American S tandard Inc. Troup Highwa y Tyler, TX 75 711-9010 ...

Manufacturer Trane Category Dehumidifier

Documents that we receive from a manufacturer of a Trane TCONT803AS32DA can be divided into several groups. They are, among others:
- Trane technical drawings
- TCONT803AS32DA manuals
- Trane product data sheets
- information booklets
- or energy labels Trane TCONT803AS32DA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Trane TCONT803AS32DA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Trane TCONT803AS32DA, service manual, brief instructions and user manuals Trane TCONT803AS32DA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Trane TCONT803AS32DA.

Similar manuals

A complete manual for the device Trane TCONT803AS32DA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Trane TCONT803AS32DA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Trane TCONT803AS32DA.

A complete Trane manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Trane TCONT803AS32DA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Trane TCONT803AS32DA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Trane TCONT803AS32DA, that we can find in the current document
3. Tips how to use the basic functions of the device Trane TCONT803AS32DA - which should help us in our first steps of using Trane TCONT803AS32DA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Trane TCONT803AS32DA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Trane TCONT803AS32DA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Trane TCONT803AS32DA?

Use the form below

If you did not solve your problem by using a manual Trane TCONT803AS32DA, ask a question using the form below. If a user had a similar problem with Trane TCONT803AS32DA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)