  • Dukane 403-573-02 - page 1

    ISO 9001:2008 Products ar e manufactured in ISO register ed facilities. Intelligent Assembly Solutions www .dukane.com/us Dukane Part No. 403 - 573 - 02 iQ Series UL TR ASONIC GEN ER A T OR / PO WER SUP PL Y Auto User’ s Manual Dukane Intelligent Assembly Solutions • 2900 Dukane Drive • St. Charles, Illinois 60174 USA • TEL (630) 797 - 4900 ...

  • Dukane 403-573-02 - page 2

    Page  ii  iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 Printed in the United States of America. Part Number: 403–573–02 This ultrasonic equipment is manufactured under one or more of the following U.S. Patents: 3,7 80,9 26 3,8 25, 481 4, 131, 505 4 ,277 ,710 5,79 8,59 9 5,8 80, 580 6,984,921, 7,225,965 ...

  • Dukane 403-573-02 - page 3

    Page  iii Dukane Manual Part No. 403-573-02 R e vis ion H istor y Revision Revision Number Summary Date - 00 Original release. 10/09/2007 - 01 20kHz and 30kHz models added. 08/27/2009 System I/O Connector signals modied. Amplitude control added. - 02 I/O Connector Pin 9 signal scale revised. 12/15/2010 Miscellaneous spelling errors cor ...

  • Dukane 403-573-02 - page 4

    Page  iv  iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 This page intentionally left blank ...

  • Dukane 403-573-02 - page 5

    Page  v Dukane Manual Part No. 403-573-02 Contents Section 1- Introduction . . . . . . . . . . . . . . . . . . . . . . . 1 General User Information . . . . . . . . . . . . . . . 3 Generator Overview . . . . . . . . . . . . . . . . . . . 4 Key Generator Features . . . . . . . . . . . . . . . . 4 Thermal Considerations . . . . . . . . . . . ...

  • Dukane 403-573-02 - page 6

    Page  vi  iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 This page intentionally left blank ...

  • Dukane 403-573-02 - page 7

    Page  1 Section 1 – Intr oduction Dukane Manual Part No. 403-573-02 SECTION 1 Intr oduction General User Information . . . . . . . . . . . . . . . . . . 3 Read The Manual First . . . . . . . . . . . . . . . . . . . . . . 3 Notes, Cautions and W arnings . . . . . . . . . . . . . . . . . . 3 Drawings and T ables . . . . . . . . . . . . . ...

  • Dukane 403-573-02 - page 8

    Page  2  iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 This page intentionally left blank ...

  • Dukane 403-573-02 - page 9

    Page  3 Section 1 – Intr oduction Dukane Manual Part No. 403-573-02 General User Information Read This Manual First Before operating your ultrasonic generator , read this User ’ s Manual to become familiar with the equipment. This will ensure correct and safe operation. The manual is or ganized to allow you to learn how to safely oper ...

  • Dukane 403-573-02 - page 10

    Page  4  iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 Generator Overview This generator is designed for ultrasonic applications con- trolled by a Programmable Logic Controller (PLC). Us- ing the available system control inputs and outputs, the generator can easily be integrated into a wide variety of autom ...

  • Dukane 403-573-02 - page 11

    Page  5 Section 2 – Health & Safety Dukane Manual Part No. 403-573-02 Thermal Considerations The thermal design of this generator is for applications that require 600 watts or less of power at less than a 50% duty cycle. For applications that require higher duty cycles, an optional cooling package is available, Part Number 438- 962. ...

  • Dukane 403-573-02 - page 12

    Page  6        iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 This page intentionally left blank ...

  • Dukane 403-573-02 - page 13

    Page  7 Section 2 – Health & Safety Dukane Manual Part No. 403-573-02 SECTION 2 Health and Saf ety G e n e r a l C o n s i d e r a t i o n s .............................. 9 P l a s t i c s H e a l t h N o t i c e ................................ 9 E l e c t r i c a l S a f e t y ................................... 1 0 Power Groundi ...

  • Dukane 403-573-02 - page 14

    Page  8        iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 This page intentionally left blank ...

  • Dukane 403-573-02 - page 15

    Page  9 Section 2 – Health & Safety Dukane Manual Part No. 403-573-02 General Considerations Ple ase obser ve th ese he alth and safe ty rec omme nda tion s for saf e, e fc ient , a nd i nju ry-f ree ope rat ion of your equi pment . In th is ma nua l, the ter m sy stem re fer s to a comp lete grou p of comp onent s ass ociat ed w ...

  • Dukane 403-573-02 - page 16

    Page  10        iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 Electrical Safety Power Grounding Connection Figure 2-1 illustrates how the AC line is connected. Figure 2–1 AC Line Connection CAUTION If there is any question about grounding of your equipment and/or its elec- trical power source, con ...

  • Dukane 403-573-02 - page 17

    Page  1 1 Section 2 – Health & Safety Dukane Manual Part No. 403-573-02 St ep 1. Stand close to the load with your feet spread apart about shoulder width, with one foot slightly in front of the other for balance. Step 2. Squat down bend ing at the knees (not your waist). Tu ck your chin while keeping your back as vertical as possibl ...

  • Dukane 403-573-02 - page 18

    Page  12        iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 This page intentionally left blank ...

  • Dukane 403-573-02 - page 19

    Page  13 Section 3 – Installation Dukane Manual Part No. 403-573-02 SECTION 3 Installa tion Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 P l a c i n g ......................................... 1 5 Power Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 C h a s s i ...

  • Dukane 403-573-02 - page 20

    Page  14                  iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 This page intentionally left blank ...

  • Dukane 403-573-02 - page 21

    Page  15 Section 3 – Installation Dukane Manual Part No. 403-573-02 Unpacking Carefully open your shipping container , and make sure it contains the items shown on the shipping documents. Inspect all items, and report any missing items or damage immediately . Placing Make certain generator placement and cable routing do not interfere wi ...

  • Dukane 403-573-02 - page 22

    Page  16                  iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 Power Grounding For safety , the iQ Auto chassis must be properly ground- ed. The power line ground connection is located on the center screw terminal on the AC Power Inlet pluggable screw terminal connector . This syste ...

  • Dukane 403-573-02 - page 23

    Page  17 Section 3 – Installation Dukane Manual Part No. 403-573-02 Connecting Cables Standard Model Conguration Complete three basic connections for the standard con- guration as shown below: • AC Line Input • System Control Inputs/Status Outputs • Ultrasound Output • Grounding Details about the various system connectors ...

  • Dukane 403-573-02 - page 24

    Page  18                  iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 Pin Signal Name 1 Enable Out (+22V Current Limited) 2 Enable In (Jumper to Pin1, without an E-Stop switch) 3 Overload Out (system overload status output) 4 U/S Status Out 5 Any Fault Out 6 Power OK Out 7 Output Common (c ...

  • Dukane 403-573-02 - page 25

    Page  19 Section 3 – Installation Dukane Manual Part No. 403-573-02 Pin 1 (Enable Out) This is a current limited voltage source output intended to connect to an E-Stop circuit. If an E-Stop circuit is not used, Pin 1 must be jumpered to Pin 2 for ultrasound operation to be enabled. Pin 2 (Enable In) The output from the E-Stop circuit is ...

  • Dukane 403-573-02 - page 26

    Page  20                  iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 Optional MPC Interface Connections Complete the same basic connections used for the stan- dard iQ Auto conguration as previously described. • AC Line Input • System Control Inputs/Status Outputs • Ultrasound Out ...

  • Dukane 403-573-02 - page 27

    Page  21 Section 3 – Installation Dukane Manual Part No. 403-573-02 Pin Signal Name 1 Setup Bit 0 Input 2 Setup Bit 1 Input 3 Setup Bit 2 Input 4 Setup Bit 3 Input 5 Input Common 6 MPC Ready Out 7 Output Common T able 3-II MPC I/O Connector Signals MPC I/O Connector Pinout The MPC I/O connector is a two-piece pluggable termi- nal block ...

  • Dukane 403-573-02 - page 28

    Page  22                  iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 NOTE Ultrasound Output Connector The ultrasound output connector used with all standard generators is a high voltage (5000V) coaxial style SHV -BNC connector . This connector provides superior shielding of electri- cal n ...

  • Dukane 403-573-02 - page 29

    Page  23 Section 3 – Installation Dukane Manual Part No. 403-573-02 MPC Module Installation Guide MPC modules are designed for assembly systems where one ultrasonic generator is sequenced to as many as 16 ultrasonic probes. The MPC module is typically supplied as a stand-alone bench-top unit, or as a component that can be mounted in a t ...

  • Dukane 403-573-02 - page 30

    Page  24                  iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 Connecting Cables For stand-alone modules and securely installed panel mounted modules: Rear Connections Refer to Figure 3-4 below . Complete these connections. 1. Earth ground - Connect one end of a user-supplied 14-Gau ...

  • Dukane 403-573-02 - page 31

    Page  25 Section 3 – Installation Dukane Manual Part No. 403-573-02 MPC Module Status LEDs System Status The front panel SYSTEM ST A TUS LED lights up GREEN when the system is powered and ready - E in Figure 3-6. If this LED is lit with a YELLOW/ORANGE color , a recoverable fault condition has tripped. This indicates that the system is ...

  • Dukane 403-573-02 - page 32

    Page  27 Page  26                    iQ Series ,   Auto User ’s Manual Section 4 –System Operation Dukane Manual Part No. 403-573-02 Page  27 Page  26                    iQ Series ,   Auto User ’s Manual Section 4 –System Operation This page intentionally left blank ...

  • Dukane 403-573-02 - page 33

    Page  27 Page  26                    iQ Series ,   Auto User ’s Manual Section 4 –System Operation Page  27 Page  26                    iQ Series ,   Auto User ’s Manual Section 4 –System Operation Dukane Manual Part No. 403-573-02 SECTION 4 System Oper a tion Standard iQ A ...

  • Dukane 403-573-02 - page 34

    Page  29 Page  28                    iQ Series ,   Auto User ’s Manual Section 4 –System Operation Dukane Manual Part No. 403-573-02 Page  29 Page  28                    iQ Series ,   Auto User ’s Manual Section 4 –System Operation This page intentionally left blank ...

  • Dukane 403-573-02 - page 35

    Page  29 Page  28                    iQ Series ,   Auto User ’s Manual Section 4 –System Operation Page  29 Page  28                    iQ Series ,   Auto User ’s Manual Section 4 –System Operation Dukane Manual Part No. 403-573-02 Standard iQ Auto System Operational T est ...

  • Dukane 403-573-02 - page 36

    Page  31 Page  30                    iQ Series ,   Auto User ’s Manual Section 4 –System Operation Dukane Manual Part No. 403-573-02 Page  31 Page  30                    iQ Series ,   Auto User ’s Manual Section 4 –System Operation Five fault conditions are monitored by the ...

  • Dukane 403-573-02 - page 37

    Page  31 Page  30                    iQ Series ,   Auto User ’s Manual Section 4 –System Operation Page  31 Page  30                    iQ Series ,   Auto User ’s Manual Section 4 –System Operation Dukane Manual Part No. 403-573-02 Options for U/S Activation Connections : ? ...

  • Dukane 403-573-02 - page 38

    Page  32                    iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 This page intentionally left blank ...

  • Dukane 403-573-02 - page 39

    Page  33 Section 5 – Specications Dukane Manual Part No. 403-573-02 SECTION 5 Specica tions Generator Outline Drawings . . . . . . . . . . . . . . . . . . . . . . . . 35-36 W e i g h t .......................................... 3 7 O p e r a t i n g E n v i r o n m e n t .............................. 3 7 A C P o w e r R e q u i r ...

  • Dukane 403-573-02 - page 40

    Page  34                    iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 This page intentionally left blank ...

  • Dukane 403-573-02 - page 41

    Page  35 Section 5 – Specications Dukane Manual Part No. 403-573-02 Figure 5-1 Generator Outline Drawing TOP REAR MOUNTING BRACKET BOTTOM REAR MOUNTING BRACKET BASE MOUNTING BRACKETS(2) 2.00 [50.8] 10.61 [269.49] 7.38 [187.45] 10.73 [272.54] 2.00 [50.8] .75 [19.05] 3.35 [85.09] 3.47 [88.14] 1.44 [36.58] .91 [23.1 1] 1 1.25 [285.75] 9 ...

  • Dukane 403-573-02 - page 42

    Page  36                    iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 Figure 5-2 Generator with Optional Heat Sink Outline Drawing NOTE: ALL MOUNTING HOLES ARE .219 DIA. FOR M5 OR #10 SCREWS. OPTIONAL HEA T SINK KIT - 438-962 9.75 [247.7] OAL 9.02 [229] 2.05 [52.1] 0.38 [9.7] 1.20 [30. ...

  • Dukane 403-573-02 - page 43

    Page  37 Section 5 – Specications Dukane Manual Part No. 403-573-02 Operatin g En vi ron m en t Operate the generator within these guidelines: T emperature : 40° F to 100° F ( +5°C to +3 8°C) Air Particulates : Keep the equipment dry . Minimize exposure to moisture, dust, dirt, smoke and mold. Humidity : 5% to 95% non–condensin ...

  • Dukane 403-573-02 - page 44

    Page  38                    iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 AC Power Requirements Operating Frequency Generator Model Number Overload Power Ratings (W atts) Input AC Power Requirements Nominal AC V olt @ Maximum RMS Current North America/ Japan AC Outlet Rating 20kHz 20A T060 ...

  • Dukane 403-573-02 - page 45

    Page  39 Section 5 – Specications Dukane Manual Part No. 403-573-02 FCC The generator complies with the following Federal Communications Commission regulations. • The limits for FCC measurement procedure MP-5, “Methods of Measurement of Radio Noise Emissions from ISM Equipment”, pursuant to FCC T itle 47 Part 18 for Ultrasonic ...

  • Dukane 403-573-02 - page 46

    Page  40                    iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 This page intentionally left blank ...

  • Dukane 403-573-02 - page 47

    Section 6 – Automation Interface Page  41 Dukane Manual Part No. 403-573-02 SECTION 6 A utoma tion Interface Input/Output Connection Examples . . . . . . . . . . . . . . . . . . . 43 PNP (Sourcing) T ype Input Circuit . . . . . . . . . . . . . . . . . . . . . . . . 43 NPN (Sinking) T ype Input Circuit . . . . . . . . . . . . . . . . . . ...

  • Dukane 403-573-02 - page 48

    Page  42                    iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 This page intentionally left blank ...

  • Dukane 403-573-02 - page 49

    Section 6 – Automation Interface Page  43 Dukane Manual Part No. 403-573-02 iQ Auto (same as above) Input Common U/S Activate Fault Reset Ground +DC Input V oltage Range DC 24V 10% Input Current 10mA(typ) @ DC 24V input PNP (Sourcing) T ype Input Circuit (Pin 13) (Pin 12) (Pin 11) System I/O C onnec tor ± Figure 6-1 PNP T ype Input Cir ...

  • Dukane 403-573-02 - page 50

    Page  44                    iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 iQ Auto (same as above) Input Common U/S Activate Fault Reset Ground +DC NPN (Sinking) T ype Input Circuit Input V oltage Range DC 24V 10% Input Current 10mA(typ) @ DC 24V input System I/O C onnec tor (Pin 13) (Pin 1 ...

  • Dukane 403-573-02 - page 51

    Section 6 – Automation Interface Page  45 Dukane Manual Part No. 403-573-02 (same as above) Overload U/S Status Ground +DC NPN T ype Output Circuit Rated Output V oltage DC 24V 10% Maximum Output Current 500mA/1 Output Output Driver N Channel Power MOSFET Gate Drive L L (same as above) (same as above) Any Fault Power OK Output Common iQ ...

  • Dukane 403-573-02 - page 52

    Page  46                    iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 Figure 6-4 E-Stop Circuitry iQ Auto Enable Out Enable In Dedicated E-Stop Switch Wiring Diagram System I/O Connector (Pin 1) (Pin 2) User supplied E-stop switch iQ Auto Enable Out Enable In Automation System Safety C ...

  • Dukane 403-573-02 - page 53

    Section 7 – Contacting Dukane Page  47 Dukane Manual Part No. 403-573-02 SECTION 7 Contacting Dukane ...

  • Dukane 403-573-02 - page 54

    Page  48                    iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 This page intentionally left blank ...

  • Dukane 403-573-02 - page 55

    Section 7 – Contacting Dukane Page  49 Dukane Manual Part No. 403-573-02 Co ntacting D uka ne Identify Equipment When contacti ng Dukane about a servi ce–related problem, be prepared to give the following information: • Model number , line voltage and serial number . • Fault status. • Problem description and steps taken to resol ...

  • Dukane 403-573-02 - page 56

    Page  50                    iQ Series ,   Auto User ’s Manual Dukane Manual Part No. 403-573-02 This page intentionally left blank ...

  • Dukane 403-573-02 - page 57

    Dukane ISO ISO CER TIFICA TION Duka ne chose to become ISO 900 1:2008 certi- fied in order to demonstrate to our customers our continuing commitment to being a quality ve ndor . By pa ssin g it s aud it, Du kane can assu re you that we have in place a well–defined and systematic approach to quality design, manu- facturing, deliver y and ser vic ...

  • Dukane 403-573-02 - page 58

    Part No. 403- 573-02 Dukane Intelligent Assembly Solutions • 2900 Dukane Drive • St. Charles, Illinois 60174 USA • TEL (630) 797- 4900 • F AX (630) 797- 4949 iQ Series , Ultrasonic Generator/Power Supply Auto User's Manual Printed in the United States of America www .dukane.com/us Please r ef er to our website a t: www .dukane.com/us/s ...

Manufacturer Dukane Category Power Supply

Documents that we receive from a manufacturer of a Dukane 403-573-02 can be divided into several groups. They are, among others:
- Dukane technical drawings
- 403-573-02 manuals
- Dukane product data sheets
- information booklets
- or energy labels Dukane 403-573-02
All of them are important, but the most important information from the point of view of use of the device are in the user manual Dukane 403-573-02.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Dukane 403-573-02, service manual, brief instructions and user manuals Dukane 403-573-02. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Dukane 403-573-02.

Similar manuals

A complete manual for the device Dukane 403-573-02, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Dukane 403-573-02 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Dukane 403-573-02.

A complete Dukane manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Dukane 403-573-02 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Dukane 403-573-02, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Dukane 403-573-02, that we can find in the current document
3. Tips how to use the basic functions of the device Dukane 403-573-02 - which should help us in our first steps of using Dukane 403-573-02
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Dukane 403-573-02
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Dukane 403-573-02 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Dukane 403-573-02?

Use the form below

If you did not solve your problem by using a manual Dukane 403-573-02, ask a question using the form below. If a user had a similar problem with Dukane 403-573-02 it is likely that he will want to share the way to solve it.

Copy the text from the picture