  • ADTRAN Protection Switch - page 1

    1 TRA CER Monitor ed Protection Switch (MPS) Before you begin...  Required Components • (2) TRACER Baseband Proc essor (BBP) and RF Conver ter (RFC) rackmount units Or , • (2) TRACER 4103 or 4203 int egrated rackmount radio units • RS-232 interface cable and VT100 term inal (or a PC with VT 100 emulator software) fo r connecting to the uni ...

  • ADTRAN Protection Switch - page 2

    2 1 Rackmount the Unit s Install the TRACER MPS system in a location that requi res minimal antenna feedline length (the loss in this cable directly af fe cts overall system performance). The TRACER M PS should be mounted in a rack between the tw o BBP component s of the TRACER systems (see Figure 1 on page 2) . Although no space is needed between ...

  • ADTRAN Protection Switch - page 3

    3 2 Creating the VT100 Chain A single VT100 connec tion through the TRACER MPS provides access to bo th the primary (MAIN) and SECONDARY TRACER units. Follow the steps below to create the VT100 chain. 1. Connect the RS-232 port (D B-25) on the rear p anel of the MAIN TRACER BBP to the TRACER MPS VT1 00 interface (labeled 1 on the figure below) usin ...

  • ADTRAN Protection Switch - page 4

    4 2 8 10 4 5 6 9 1 7 4 Reviewing the Menus The TRACER MPS software interface consis t s of a single menu screen (s hown below). Navigate through the available menu options using the up and down arrow ke ys. Alternately , the numbered m enu options may be selected by en tering the appropriate menu numbe r displayed to the left of the opt ion. Pressi ...

  • ADTRAN Protection Switch - page 5

    5 MANAGEMENT T R A C E R MAIN STANDBY OUT NO COM NC MN COM SB IN ALARMS DC POWER RF ANTENNA TO DTE RS-232 MONITOR T1B T1A MAIN TRACER ST ANDBY TRACER MONITOR POWER MODULE USE COPPER CONDUCTORS ONL Y MAIN OUT IN IN OUT B A B A STAND BY T1B T1A TRACER MPS T1A/T1B Interfaces TRACER MPS MAIN T1A Interface 6 4 2 5 5 Connecting the T1 Interfaces 1. Conne ...

  • ADTRAN Protection Switch - page 6

    6 MANAGEMENT T1B T1A IF ANTENNA T R A C E R MAIN STANDBY OUT NO COM NC MN COM SB IN ALARMS DC POWER RF ANTENNA TO DTE RS-232 MONITOR T1B T1A MAIN TRACER ST ANDBY TRACER MONITOR POWER MODULE USE COPPER CONDUCTORS ONL Y OUT IN IN OUT B A B A MAIN STAND BY 2 5 6 TRACER MPS Antenna Interface TRACER MPS ST ANDBY Antenna Interface TRACER MPS MAIN Antenna ...

  • ADTRAN Protection Switch - page 7

    7 6b Connecting the Antenna Interface s (TRACER 4103 and 4203 Systems) 1. Connect the Antenna interface (N-T ype connector) of the MA IN TRACER 4103/4203 (label ed 1 below) to the MA IN RF interface (SMA connector) of the TRACER MPS (labeled 2 below) using a male N-T ype to male SMA cable. 2. Repeat S tep 1 to connect the An tenna interface (N-T yp ...

  • ADTRAN Protection Switch - page 8

    8 7 Connecting the Alarm Cont act s 1. Connect the NO (Norma lly Open) alarm contact of the MAIN TRACER BBP (labeled 1 belo w) to the MN alarm c ontact in the IN alarm block of the TRACER MPS (l abeled 2 below). The TRACER BBP provides two sets of alarm contact s; for no rmal configuration, use the NO located in the MAJ (Major Alarm) block. 2. Conn ...

  • ADTRAN Protection Switch - page 9

    9 8 Supplying Power to the Unit The TRACER MPS can operate from a supply between 21 and 63 V olts DC, with either polarity referenced to ground, and consumes 3 W atts nominal, 20 W a tts peak (during relay switching). Curr ent required (in Amp s) is determined by dividi ng the power consume d (in W att s) by the applied voltage (in V olts). As an e ...

Manufacturer ADTRAN Category Network Card

Documents that we receive from a manufacturer of a ADTRAN Protection Switch can be divided into several groups. They are, among others:
- ADTRAN technical drawings
- Protection Switch manuals
- ADTRAN product data sheets
- information booklets
- or energy labels ADTRAN Protection Switch
All of them are important, but the most important information from the point of view of use of the device are in the user manual ADTRAN Protection Switch.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals ADTRAN Protection Switch, service manual, brief instructions and user manuals ADTRAN Protection Switch. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product ADTRAN Protection Switch.

A complete manual for the device ADTRAN Protection Switch, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use ADTRAN Protection Switch by users. Manuals are usually written by a technical writer, but in a language understandable to all users of ADTRAN Protection Switch.

A complete ADTRAN manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual ADTRAN Protection Switch - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the ADTRAN Protection Switch, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the ADTRAN Protection Switch, that we can find in the current document
3. Tips how to use the basic functions of the device ADTRAN Protection Switch - which should help us in our first steps of using ADTRAN Protection Switch
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with ADTRAN Protection Switch
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of ADTRAN Protection Switch in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning ADTRAN Protection Switch?

Use the form below

If you did not solve your problem by using a manual ADTRAN Protection Switch, ask a question using the form below. If a user had a similar problem with ADTRAN Protection Switch it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)