  • Extron electronic MGP 464 DI - page 1

    MGP 464 MGP 464 DI Multi-Graphic Pr ocessor 68-1235-01 Rev . B 10 08 ...

  • Extron electronic MGP 464 DI - page 2

    This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’ s enclosure that may present a risk of electric shock. Caution Read Instructions • ...

  • Extron electronic MGP 464 DI - page 3

    FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interfer ence received, including interference that ma ...

  • Extron electronic MGP 464 DI - page 4

    ...

  • Extron electronic MGP 464 DI - page 5

    MGP 464 • Quick Start QS-1 PRELIMINAR Y Qu ick St art — MGP 464 Installation Step 1 Install the four rubber feet on the bottom of the MGP 464, or mount the unit using the supplied rack mounting brackets. Rack mounting the MGP 464 Step 2 T urn off power to the input and output devices, and remove the power cor ds from them. Step 3 Attach the inp ...

  • Extron electronic MGP 464 DI - page 6

    MGP 464 • Quick Start QS-2 PRELIMINAR Y Quick Start — MGP 464, cont’d Step 4 Attach an output device to the RGBHV/YUV BNC connectors and/or to the DVI output connector (shown below). N Analog is not available on this DVI connector . BNC output connectors Step 5 Plug the MGP 464, input devices, and output devices into a grounded AC source, and ...

  • Extron electronic MGP 464 DI - page 7

    Quick Start — MGP 464, cont’d QS-3 MGP 464 • Quick Start PRELIMINAR Y Main menu Step 4 From the Advanced Configuration menu, change the test pattern to Crop, and adjust your display’s positioning until all four sides of the crop pattern are visible. Adjusting the picture contr ols Step 5 Use the W indow Conguration menu to select a wind ...

  • Extron electronic MGP 464 DI - page 8

    MGP 464 • Quick Start QS-4 PRELIMINAR Y Quick Start — MGP 464, cont’d d . Rotate the Adjust knobs until the H and V values repr esent the image dimensions or position coordinates you want for the selected input. e . Repeat steps c and d as needed to refine the size and position adjustments for the selected input. f . Repeat steps a through e ...

  • Extron electronic MGP 464 DI - page 9

    i MGP 464 • T able of Contents PRELIMINAR Y T able of Contents Chapter On e • Introduction ...................................................................................................... 1-1 About This Manual .................................................................................................................... 1-2 About the ...

  • Extron electronic MGP 464 DI - page 10

    T able of Contents, cont’d MGP 464 • T able of Contents ii PRELIMINAR Y Background Capture menu ................................................................................................... 3-16 Memory space for background files ........................................................................ 3-16 Saving a background to memory .. ...

  • Extron electronic MGP 464 DI - page 11

    iii MGP 464 • T able of Contents PRELIMINAR Y Chapter Fiv e • HTML Conguration and Control ..................................................... 5-1 Accessing the Web Pages ...................................................................................................... 5-2 Viewing System Status ......................................... ...

  • Extron electronic MGP 464 DI - page 12

    T able of Contents, cont’d MGP 464 • T able of Contents iv PRELIMINAR Y Using the Background Page ............................................................................................... 5-23 Selecting a background color ................................................................................................ 5-23 Displaying a bac ...

  • Extron electronic MGP 464 DI - page 13

    PRELIMINAR Y MGP 464 Multi-Graphic Pr ocessor 1 Chapter One Intr oduction About This Manual About the MGP 464 Multi-Graphic Processor Features Application Diagrams ...

  • Extron electronic MGP 464 DI - page 14

    MGP 464 • Introduction 1-2 Intr oduction PRELIMINAR Y About This Manual This manual discusses how to install, congure, and operate the Extr on MGP 464 multi-graphic processor . Throughout this manual, the terms “MGP ,” “multi-graphic processor ,” and “processor” ar e used interchangeably to refer to the same pr oduct. About the MGP ...

  • Extron electronic MGP 464 DI - page 15

    1-3 MGP 464 • Introduction PRELIMINAR Y The MGP 464’s advanced lm mode pr ocessing recognizes signals that originated from lm. The MGP then applies video processing algorithms that optimize the conversion of video made in the 3:2 pulldown process. This results in richly detailed images with sharply defined lines. A similar process, 2:2 ? ...

  • Extron electronic MGP 464 DI - page 16

    Intr oduction, cont’d MGP 464 • Introduction 1-4 PRELIMINAR Y Camera Extron MGP 464 Four Window Multi-Graphic Processor Control System D VD .5A MAX 1 0 0 - 240 50/60 Hz 1 INPUT 1- DV I-D R R-Y G/Y VID H/HV V H/HV B/C B-Y 2 R R-Y G/Y VID H/HV V H/HV B/C B-Y 3 R R-Y G/Y VID H/HV V H/HV B/C B-Y 4 5 R R-Y G/Y VID H/HV V H/HV B/C B-Y R/ R-Y VID Y 6 ...

  • Extron electronic MGP 464 DI - page 17

    PRELIMINAR Y MGP 464 Multi-Graphic Pr ocessor 2 Chapter T wo Installation Installation Overview Mounting the MGP 464 Installing or Replacing Button Labels Rear Panel Features ...

  • Extron electronic MGP 464 DI - page 18

    MGP 464 • Installation 2-2 Installation PRELIMINAR Y Installation Overview The MGP 464 pr ocessor can be connected to as many as 19 input devices simultaneously , and two output devices. Follow these steps to install the MGP 464: 1 Disconnect power to the MGP , and turn off all other devices that will be connected. 2 If desired, mount the MGP . S ...

  • Extron electronic MGP 464 DI - page 19

    2-3 MGP 464 • Installation PRELIMINAR Y • Circuit overloading — When connecting the equipment to the supply circuit, consider the connection of the equipment to the supply cir cuit and the effect that cir cuit overloading might have on overcurrent pr otection and supply wiring. Consider equipment nameplate ratings when addressing this concern ...

  • Extron electronic MGP 464 DI - page 20

    Installation, cont’d MGP 464 • Installation 2-4 PRELIMINAR Y Installing or Replacing Button Labels The button caps are pr e-labeled for your convenience by default. However , you can replace them with button labels that you create, using the Button-Label Generator or other button label software. The button assembly consists of a clear lens cap, ...

  • Extron electronic MGP 464 DI - page 21

    2-5 MGP 464 • Installation PRELIMINAR Y Rear Panel Featur es The diagram below shows the rear panel of the MGP 464 DI, which has four DVI-I input connectors ( j in the illustration below ). The standard MGP 464 does not have these DVI input connectors (although it does have DVI Output and DVI Background connectors). In all other r espects the MGP ...

  • Extron electronic MGP 464 DI - page 22

    Installation, cont’d MGP 464 • Installation 2-6 PRELIMINAR Y VI D Y VI D B- Y C VI D R- Y 5 6 7 VI D Y VI D B- Y C VI D R- Y 5 6 7 S-video and Composite Component VID Y VID B- Y C VID R- Y 5 6 7 Composite Virtual input connector configuration examples Y ou can congure these virtual inputs for the desir ed signal types using the W indows-bas ...

  • Extron electronic MGP 464 DI - page 23

    2-7 MGP 464 • Installation PRELIMINAR Y Use a straight-through cable to connect to a network, or a cr ossover cable to connect directly to a computer . • For 10BaseT (10 Mbps) networks, use a Cat 3 or better cable. • For 100BaseT (max. 155 Mbps) networks, use a Cat 5 cable. Straight-through Cable (for connection to a s witch, hub, or router) ...

  • Extron electronic MGP 464 DI - page 24

    Installation, cont’d MGP 464 • Installation 2-8 PRELIMINAR Y 7 BNC output connectors — Plug an output device into these ve BNC connectors, as shown below . R /R-Y G /Y B /B-Y H /HV V R /R-Y G /Y B /B-Y H /HV V R /R-Y G /Y B /B-Y H /HV V R /R-Y G /Y B /B-Y H /HV V RGBHV RGBS RGsB HD YUV Component Video Connecting to output BNC connectors 8 ...

  • Extron electronic MGP 464 DI - page 25

    PRELIMINAR Y MGP 464 Multi-Graphic Pr ocessor 3 Chapter Thr ee Operation Front Panel Features Power-up and Default Cycle Input Selection Window Select Buttons Menus, Configuration, and Adjustments Picture Controls Auto Memories Memory Presets Additional Features ...

  • Extron electronic MGP 464 DI - page 26

    MGP 464 • Operation 3-2 Operation PRELIMINAR Y Y ou can set up and operate the MGP 464 by using: • The fr ont panel controls • A computer , a touch screen panel, or any other device that can send and receive serial communications through either serial port or thr ough the LAN port. Settings can be adjusted through the host computer using Extr ...

  • Extron electronic MGP 464 DI - page 27

    3-3 MGP 464 • Operation PRELIMINAR Y The virtual input buttons are arranged in five columns of thr ee buttons each, reflecting the arrangement of the virtual input connectors on the rear panel. Component video sour ces must be connected to all three input connectors in a column; S-video sources must be connected to the top two connectors in the ...

  • Extron electronic MGP 464 DI - page 28

    Operation, cont’d MGP 464 • Operation 3-4 PRELIMINAR Y 6 feet (1.8 m) Pa rt #70-335-01 9DBF-2.5mm TRS cable_031504.eps 5 1 9 6 Slee ve (Gnd) Ring Tip 9-pin D Connection TRS Plug Pin 2 Computer's RX line Tip Pin 3 Computer's TX line Ring Pin 5 Computer's signal ground Slee ve 2.5 mm connector cable for the configuration port (par ...

  • Extron electronic MGP 464 DI - page 29

    3-5 MGP 464 • Operation PRELIMINAR Y Window Select Buttons The MGP 464 fr ont panel contains four W indow Select buttons. Use these buttons in conjunction with the Input buttons to specify which window displays an input, or use them with the picture contr ol buttons to specify which window/image is adjusted. When you select a picture contr ol, th ...

  • Extron electronic MGP 464 DI - page 30

    Operation, cont’d MGP 464 • Operation 3-6 PRELIMINAR Y Menus, Configuration, and Adjustments The MGP 464’s menus enable you to congur e the processor . The menu navigation buttons (Menu and Next) are located to the lower left of the LCD scr een. Press these buttons to cycle through the available menu and submenu options. Menu system overv ...

  • Extron electronic MGP 464 DI - page 31

    3-7 MGP 464 • Operation PRELIMINAR Y Po wer on Multi-Graphic Processor Input Configuration 2 sec. Menu Menu Output Configuration Menu 20 sec. Window Configuration Menu 20 sec. 20 sec. Default Cycle Extron MGP 464 V1.00 2 sec. Adv anced Configuration 20 sec. Menu Menu Next Exit Menu Press Next Menu 20 sec. Comm. / IP Configuration Menu 20 sec. Au ...

  • Extron electronic MGP 464 DI - page 32

    Operation, cont’d MGP 464 • Operation 3-8 PRELIMINAR Y Auto Image menu The Auto Image menu causes the MGP 464 to perform an automatic image adjustment in the selected window . Auto Image measures where the active ar ea starts and stops, and adjusts input sampling accordingly , so that the image fills the window . When an input is connected, th ...

  • Extron electronic MGP 464 DI - page 33

    3-9 MGP 464 • Operation PRELIMINAR Y Input Conguration menu The Input Configuration menu allows you to select a video signal type for each of the four fully configurable inputs. All of these inputs can accept the following video signals: RGB, YUV -HD, YUV i, RGBcvS, S-video, composite video, and DVI (MGP 464 DI only); RGB is the default. Y o ...

  • Extron electronic MGP 464 DI - page 34

    Operation, cont’d MGP 464 • Operation 3-10 PRELIMINAR Y Input conguration submenu adjustments The table below shows how to make the selections and adjustments that are accessed through the Input Configuration submenus. Input Conguration submenu Horizontal Knob Adjustment V ertical Knob Adjustment V ideo type The following video signal ty ...

  • Extron electronic MGP 464 DI - page 35

    3-11 MGP 464 • Operation PRELIMINAR Y Input Conguration submenu Horizontal Knob Adjustment V ertical Knob Adjustment Pixel phase 4 The point at which pixels are sampled for window 4. (The values cannot be changed for DVI, YUV i, S-video, or composite video inputs.) Select input #1, 2, 3, or 4 for window 4. Increase or decr ease the displayed v ...

  • Extron electronic MGP 464 DI - page 36

    Operation, cont’d MGP 464 • Operation 3-12 PRELIMINAR Y Resolution and Refresh Rate submenu While this submenu is displayed, rotate the horizontal Adjust ( [ ) knob to select one of the available resolutions, or r otate the vertical Adjust ( { ) knob to select one of the available refr esh rates. The resolutions and refr esh rates are listed in ...

  • Extron electronic MGP 464 DI - page 37

    3-13 MGP 464 • Operation PRELIMINAR Y Sync Polarity submenu The display device may requir e a particular combination of horizontal (H) and vertical (V) sync signal polarities. Rotate either the horizontal Adjust ( [ ) or the vertical Adjust ( { ) knob to select the sync polarity . The options are H-V -, H+V -, H-V+, H+V+, or NA (appears when YUV ...

  • Extron electronic MGP 464 DI - page 38

    Operation, cont’d MGP 464 • Operation 3-14 PRELIMINAR Y Window Border submenus Use these submenus (one for each window) to select colored bor ders for the four windows. T urn either Adjust knob to display the available options: Red, Green, Blue, White, Magenta, Cyan, Y ellow , and Black. Y ou can also select Off, which species no border . Th ...

  • Extron electronic MGP 464 DI - page 39

    3-15 MGP 464 • Operation PRELIMINAR Y Square wipe — A square wipe causes the new window to appear to unroll over the other one in one of two ways: • In from the top, bottom, right, and left edges to the center of the window • Out from the center to the four edges of the window This effect cr eates a square shaped transition. A square wipe c ...

  • Extron electronic MGP 464 DI - page 40

    Operation, cont’d MGP 464 • Operation 3-16 PRELIMINAR Y Background Captur e menu The Background Captur e menu allows you to capture the image currently on the output screen and save it as a bitmap (.bmp) le with one of 16 designated image names. Y ou can then recall the image and use it as a background. Background Captur e also can be done v ...

  • Extron electronic MGP 464 DI - page 41

    3-17 MGP 464 • Operation PRELIMINAR Y 4 . Press the Next button to save the image as a bitmap (.bmp) file. The LCD screen displays the message “[Detail] = Conrm.” N The unit supports 24-bit bitmap files only . Their file names must have no more than 16 characters, including the .bmp extension. C The image that you save overwrites any ex ...

  • Extron electronic MGP 464 DI - page 42

    Operation, cont’d MGP 464 • Operation 3-18 PRELIMINAR Y Making changes to the serial port and IP conguration T o make changes to the serial port conguration, IP addr ess, DHCP mode, Gateway address, and/or Subnet mask, you must access the edit level scr eens as follows: 1 . W ith any Comm./IP Conguration menu view-level scr een display ...

  • Extron electronic MGP 464 DI - page 43

    3-19 MGP 464 • Operation PRELIMINAR Y Advanced Configuration menu Use the Advanced Conguration menu to set the background color , turn blue mode on and off, and select test patterns. Y ou can also view the MGP’s internal temperature and r eset the system to its factory default settings. Advanced Configuration menu flow Background Color su ...

  • Extron electronic MGP 464 DI - page 44

    Operation, cont’d MGP 464 • Operation 3-20 PRELIMINAR Y T est Patter n submenu Several test patterns are available via this submenu to adjust the display device for color , convergence, focus, resolution, contrast, grayscale, and aspect ratio. Use either Adjust knob to select a test pattern. The available patterns are: • Colorbars (8 color ba ...

  • Extron electronic MGP 464 DI - page 45

    3-21 MGP 464 • Operation PRELIMINAR Y Internal T emperature scr een The Internal T emp submenu displays the unit’s current internal temperatur e. The MGP 464 displays the temperatur e in degrees Fahrenheit and Celsius. This is an information-only screen; no adjustments can be made on it. Factory Default submenu This submenu lets you reset the M ...

  • Extron electronic MGP 464 DI - page 46

    Operation, cont’d MGP 464 • Operation 3-22 PRELIMINAR Y Button Display Function Range Adjust Knob Detail DET AIL nnnn Adjust image sharpness. 000 - 127 Default: 064 Either Window/ Image Position WINDOW_ n CNTR: H=± nnnn V=± nnnn Position window 1, 2, 3, or 4 on the output screen in r elation to center . Default: 0000 ± the output rate For H: ...

  • Extron electronic MGP 464 DI - page 47

    3-23 MGP 464 • Operation PRELIMINAR Y Auto Memories Whenever changes are made to the settings described in the pr evious pages, the MGP automatically saves the changes in memory . These settings are saved based on the input frequency and ar e later recalled when the identical resolution is applied to the configured input. These memory locations ...

  • Extron electronic MGP 464 DI - page 48

    Operation, cont’d MGP 464 • Operation 3-24 PRELIMINAR Y 4 . Press the Enter button to save the curr ent window setting in the preset location that you selected. The LCD screen shows a message indicating that the preset is being saved to the selected memory location, followed by a message that the preset has been saved. The following examples sh ...

  • Extron electronic MGP 464 DI - page 49

    3-25 MGP 464 • Operation PRELIMINAR Y Default presets The following figure shows the factory default pr eset window configurations. These presets can be used for any output rate. If you overwrite them, you can recover them by selecting Factory Defaults fr om the Advanced Configuration menu. (See “Advanced Conguration menu,” earlier in t ...

  • Extron electronic MGP 464 DI - page 50

    Operation, cont’d MGP 464 • Operation 3-26 PRELIMINAR Y N The 128 input pr esets are global, containing all of the settings for an input when the MGP is used with a matrix switcher . This allows a matrix switcher with multiple types of video inputs to be connected to the MGP 464 to expand the number of input video sources. Each input should be ...

  • Extron electronic MGP 464 DI - page 51

    3-27 MGP 464 • Operation PRELIMINAR Y Reset Mode Comparison/Summary Mode Activation Result Purpose/Notes 1 Hold in the recessed Reset button (located next to the LAN connector) while applying power to the unit. 3 Hold in the Reset button for 3 seconds, until the Reset LED blinks once. Then, within 1 second, press Reset again briefly (for less tha ...

  • Extron electronic MGP 464 DI - page 52

    Operation, cont’d MGP 464 • Operation 3-28 PRELIMINAR Y ...

  • Extron electronic MGP 464 DI - page 53

    PRELIMINAR Y MGP 464 Multi-Graphic Pr ocessor 4 Chapter Four Softwar e Conguration and Contr ol Setting Up RS-232/422 Communication Using Simple Instruction Set (SIS) Commands Windows ® -based Control Software ...

  • Extron electronic MGP 464 DI - page 54

    MGP 464 • Software Conguration and Contr ol 4-2 Softwar e Conguration and Control PRELIMINAR Y The MGP 464 can be congur ed and controlled by software via the following interfaces: RS-232 or RS-422 (Simple Instruction Set [SIS • ™ ] commands or W indows ® - based control softwar e) LAN (W eb pages, SIS commands, or W indows-based co ...

  • Extron electronic MGP 464 DI - page 55

    4-3 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y N The cables used to connect the RS-232/422 port to a computer or contr ol system may need to be modified by removing pins or cutting wir es. If unneeded pins are connected, the processor may hang up. See chapter 2, "Installation," for mor e information on wiring the conne ...

  • Extron electronic MGP 464 DI - page 56

    Softwar e Conguration and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-4 PRELIMINAR Y Error r esponses When the MGP 464 r eceives a valid SIS command, it executes the command and sends a response to the host device. If the pr ocessor is unable to execute the command because the command is invalid or contains invalid para ...

  • Extron electronic MGP 464 DI - page 57

    4-5 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y • There ar e a few differences in how to enter the commands depending on whether you are using T elnet or a W eb browser . • For control via a W eb browser , all non-alphanumeric characters must be repr esented as the hexadecimal equivalent, %xx, where xx repr esents the two- cha ...

  • Extron electronic MGP 464 DI - page 58

    Softwar e Conguration and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-6 PRELIMINAR Y X1% = Mail domain name (e.g., Extron.com) X1& = T ime in tens of milliseconds to wait for the response via the serial port Default = 10 (100 ms) Maximum = 32767 X1* = Hardwar e (MAC) address (xx-xx-xx-xx-xx-xx) X1( = Subnet mask (xx ...

  • Extron electronic MGP 464 DI - page 59

    4-7 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y X6^ = Login without password is allowed. If enabled, the user does not enter a password. After the user clicks OK, the login level is set based on the setting in the X6* parameter . 0 = Disabled 1 = Enabled X6* = No-password login level 1 through 1 1 = Entry without password goes to ...

  • Extron electronic MGP 464 DI - page 60

    Softwar e Conguration and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-8 PRELIMINAR Y X51% = Scaler refr esh rate 1 = 50 Hz 2 = 60 Hz 3 = 72 Hz 4 = 96 Hz 5 = 100 Hz 6 = 120 Hz 7 = DVI background input r efresh rate X51^ = Pixel phase (0-31) X51& = Advanced picture settings value (Range is the auto-sensed value ±512 ...

  • Extron electronic MGP 464 DI - page 61

    4-9 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description Input selection Select an input X50) * X50@ ! Out X50@ • In X50) ] Set input source X50) to window X50@ . V iew input X50@ ! X50) ] V ie ...

  • Extron electronic MGP 464 DI - page 62

    SIS ™ Pr ogramming and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-10 PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description Window blanking (muting) Mute window X50@ * 1B X50@ Blk1 ] Blank (mute) window(s) X50@ using ...

  • Extron electronic MGP 464 DI - page 63

    4-11 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description Window preset ef fect N For information on setting the two available transition effects for window presets, r efer to the MGP 464 Windows ...

  • Extron electronic MGP 464 DI - page 64

    SIS ™ Pr ogramming and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-12 PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description Detail lter Specific value X50@ * X51) D X50@ Det X51) ] Set detail (sharpness) level for ...

  • Extron electronic MGP 464 DI - page 65

    4-13 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description V ertical shift (image) Specific value 2 * X50@ * X52! / X50@ Ivp X52! ] Set vertical centering of the image in window X50@ to X52! . X5 ...

  • Extron electronic MGP 464 DI - page 66

    SIS ™ Pr ogramming and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-14 PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description V ertical size (image) Specific value 2 * X50@ * X52# ; X50@ Ivs X52# ] Set the height of th ...

  • Extron electronic MGP 464 DI - page 67

    4-15 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description Image size and position Set image size and position E X50@ , X52! * X52! * X52# * X52# I Y } Ixy X50@ , X52! * X52! * X52# * X52# ] Set p ...

  • Extron electronic MGP 464 DI - page 68

    SIS ™ Pr ogramming and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-16 PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description Input presets Recall input preset 3 * X50@ * X51$ . Rpr 3 * X51$ ] Recall input preset X51$ t ...

  • Extron electronic MGP 464 DI - page 69

    4-17 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description Horizontal start Specific value X50) * X51@ ) Hst X50) * X51@ ] Set the horizontal position of the first active pixel in the active win ...

  • Extron electronic MGP 464 DI - page 70

    SIS ™ Pr ogramming and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-18 PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description Active lines Specific value 13 * X50) * X51& # Aln X50) * X51& ] Set the active line ...

  • Extron electronic MGP 464 DI - page 71

    4-19 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description Set test pattern X50$ J T st X50$ ] Select test pattern X50$ . For X50$ : 0 = Off (none) 8 = Cr op 1 = Colorbars 9 = Side By Side (4x3 cr ...

  • Extron electronic MGP 464 DI - page 72

    SIS ™ Pr ogramming and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-20 PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description Query rmware version Q x.xx ] V iew the rmware version number . Query part number N 60- ...

  • Extron electronic MGP 464 DI - page 73

    4-21 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description T ext size 10 * X # T sz X ] Set the size of the label text. For X : 1 = Small 2 = Medium 3 = Large V iew text size 10 # X ] V iew th ...

  • Extron electronic MGP 464 DI - page 74

    SIS ™ Pr ogramming and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-22 PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description W indow border color 9 * X50@ * X # X50@ Br d X ] Set the color of the border around window ...

  • Extron electronic MGP 464 DI - page 75

    4-23 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for SIS commands (continued) Command ASCII (T elnet) (host to switcher) Response (switcher to host) Additional description Enable lm mode 18 * X50) * 1 # X50) Flm 1 ] Enable lm mode for input X50) . (Auto-senses for 3:2 or 2:2 pull-down.) X50) = 1 throug ...

  • Extron electronic MGP 464 DI - page 76

    SIS ™ Pr ogramming and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-24 PRELIMINAR Y Command/response table for IP SIS commands (continued) Command ASCII (T elnet) (host to processor) URL Encoded (Web) (host to processor) Response (Processor to host) Additional description Bi-directional serial data port Send data string E ...

  • Extron electronic MGP 464 DI - page 77

    4-25 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for IP SIS commands (continued) Command ASCII (T elnet) (host to processor) URL Encoded (Web) (host to processor) Response (Processor to host) Additional description Bi-directional serial data port (continued) Configure mode 24 E X! * X2( CY } W X! %2A X2( CY ...

  • Extron electronic MGP 464 DI - page 78

    SIS ™ Pr ogramming and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-26 PRELIMINAR Y Command/response table for IP SIS commands (continued) Command ASCII (T elnet) (host to processor) URL Encoded (Web) (host to processor) Response (Processor to host) Additional description Ethernet data port Set current connection port tim ...

  • Extron electronic MGP 464 DI - page 79

    4-27 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for IP SIS commands (continued) Command ASCII (T elnet) (host to processor) URL Encoded (Web) (host to processor) Response (Processor to host) Additional description Firmware version r equests (continued) Query updated rmware version 4Q 4Q X1! (plus web ver ...

  • Extron electronic MGP 464 DI - page 80

    SIS ™ Pr ogramming and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-28 PRELIMINAR Y Command/response table for IP SIS commands (continued) Command ASCII (T elnet) (host to processor) URL Encoded (Web) (host to processor) Response (Processor to host) Additional description Event control Read event buffer memory 27 E X3% , ...

  • Extron electronic MGP 464 DI - page 81

    4-29 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for IP SIS commands (continued) Command ASCII (T elnet) (host to processor) URL Encoded (Web) (host to processor) Response (Processor to host) Additional description Event control (continued) Start events 24 27 E 1AE } W 1AE | Ego ] Initiate all pr ogrammed ev ...

  • Extron electronic MGP 464 DI - page 82

    SIS ™ Pr ogramming and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-30 PRELIMINAR Y Command/response table for IP SIS commands (continued) Command ASCII (T elnet) (host to processor) URL Encoded (Web) (host to processor) Response (Processor to host) Additional description IP setup commands Set unit name 24 E X1@ CN } W X1 ...

  • Extron electronic MGP 464 DI - page 83

    4-31 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for IP SIS commands (continued) Command ASCII (T elnet) (host to processor) URL Encoded (Web) (host to processor) Response (Processor to host) Additional description IP setup commands (continued) Set daylight saving time 24 E X3$ CX } W X3$ CX | Ipx X3$ ] X3$ ...

  • Extron electronic MGP 464 DI - page 84

    SIS ™ Pr ogramming and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-32 PRELIMINAR Y Command/response table for IP SIS commands (continued) Command ASCII (T elnet) (host to processor) URL Encoded (Web) (host to processor) Response (Processor to host) Additional description IP setup commands (continued) Set administrator pa ...

  • Extron electronic MGP 464 DI - page 85

    4-33 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for IP SIS commands (continued) Command ASCII (T elnet) (host to processor) URL Encoded (Web) (host to processor) Response (Processor to host) Additional description IP setup commands (continued) V iew read-only security level support 24 E EP } W EP | X6^ * X6 ...

  • Extron electronic MGP 464 DI - page 86

    SIS ™ Pr ogramming and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-34 PRELIMINAR Y Command/response table for IP SIS commands (continued) Command ASCII (T elnet) (host to processor) URL Encoded (Web) (host to processor) Response (Processor to host) Additional description Re-map port designations (continued) Disable W eb ...

  • Extron electronic MGP 464 DI - page 87

    4-35 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Command/response table for IP SIS commands (continued) Command ASCII (T elnet) (host to processor) URL Encoded (Web) (host to processor) Response (Processor to host) Additional description Mail server setup commands Set mail server IP , unit domain name 24 E X1$ , X1% CM } W X1$ %2C ...

  • Extron electronic MGP 464 DI - page 88

    Softwar e Conguration and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-36 PRELIMINAR Y Windows ® -based Contr ol Softwar e The MGP 464 W indows-based control software pr ogram provides a convenient way to configure the inputs, output, windows, and images in each window . It also lets you save and recall input and windo ...

  • Extron electronic MGP 464 DI - page 89

    4-37 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Link to the installation software on the MGP 464 CD 3 . In the table on the Control Softwar e screen, scroll to locate the MGP 464, and click the Install link in the far right column. 4 . On the File Download window that appears, click Run to begin installing the program. File Downl ...

  • Extron electronic MGP 464 DI - page 90

    Softwar e Conguration and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-38 PRELIMINAR Y If you want to save the installation le (MGP464Setupv n _ n .exe) to your desktop to run later , click Save instead of Run . On the Save As window , save the setup le to the desired location on your PC. When you ar e ready to ins ...

  • Extron electronic MGP 464 DI - page 91

    4-39 MGP 464 • Software Conguration and Contr ol PRELIMINAR Y Starting the control pr ogram The MGP 464 softwar e help program provides information on settings and on how to use the control pr ogram itself. 1 . T o run the MGP 464 conguration program, do either of the following: • Double-click on the MGP464.exe icon, located on your compu ...

  • Extron electronic MGP 464 DI - page 92

    Softwar e Conguration and Contr ol, cont’d MGP 464 • Software Conguration and Contr ol 4-40 PRELIMINAR Y 3 . On the selected tab, enter the information requir ed for the type of communication you chose. • TCP/IP: Enter your MGP’s IP addr ess, T elnet port (the default is 23), and a password if desir ed. • RS-232/422: Select your PC? ...

  • Extron electronic MGP 464 DI - page 93

    PRELIMINAR Y MGP 464 Multi-Graphic Pr ocessor 5 Chapter Five HTML Conguration and Contr ol Accessing the W eb Pages Viewing System Status Using the Configuration Page Using the File Management Page Using the Control Page Using the Background Page ...

  • Extron electronic MGP 464 DI - page 94

    MGP 464 • HTML Conguration and Control 5-2 HTML Conguration and Contr ol PRELIMINAR Y The MGP 464 can be contr olled and congured using HTML W eb pages accessed over a network or from a local PC connected to the MGP 464’s LAN port. The MGP 464 has factory-installed HTML W eb pages that allow you to select and configure inputs, adjust ...

  • Extron electronic MGP 464 DI - page 95

    5-3 MGP 464 • HTML Conguration and Control PRELIMINAR Y 5 . If in step 4 you entered the lename for a custom HTML page, the browser displays that page. If not, the browser displays the System Status page, which is the MGP 464’s default start page. Y ou can select the tabs at the top of this screen to display additional scr eens that enabl ...

  • Extron electronic MGP 464 DI - page 96

    HTML Conguration and Contr ol, cont’d MGP 464 • HTML Conguration and Control 5-4 PRELIMINAR Y Using the Conguration Page There ar e six Conguration W eb pages, which only administrators can access. These pages are listed in the sidebar menu at the left of the Configuration scr een. The following sections describe the changes you ca ...

  • Extron electronic MGP 464 DI - page 97

    5-5 MGP 464 • HTML Conguration and Control PRELIMINAR Y Scaler I/O Settings screen On the Scaler I/O Settings screen (shown below), you can specify configuration settings for the 4 fully congurable inputs, the 15 virtual inputs, and the output. Y ou can also select a test pattern and enable or disable blue mode. Scaler I/O Settings screen ...

  • Extron electronic MGP 464 DI - page 98

    HTML Conguration and Contr ol, cont’d MGP 464 • HTML Conguration and Control 5-6 PRELIMINAR Y T o change the name of an input, 1 . On the Scaler I/O Settings screen, select and delete the text in the box under the desired input number . 2 . Enter a name of up to 16 characters for the input. The following characters may be used: Symbols: : ...

  • Extron electronic MGP 464 DI - page 99

    5-7 MGP 464 • HTML Conguration and Control PRELIMINAR Y T est pattern — Y ou can select one of the test patterns shown on the next page to adjust the display for color , convergence, focus, resolution, contrast, grayscale, and aspect ratio. 4x 34 x3 16 x x9 16x9 Colorbars (8) X-Hatch (16x12) 4x4 X-Hatch Grey Scale Ramp Alt. Pixels Crop Side- ...

  • Extron electronic MGP 464 DI - page 100

    HTML Conguration and Contr ol, cont’d MGP 464 • HTML Conguration and Control 5-8 PRELIMINAR Y Window Settings screen The W indow Settings screen, shown below , enables you to specify various parameters for windows 1, 2, 3, and 4. Window Settings screen The following fields are pr ovided: W indow Selection — Select one of the window rad ...

  • Extron electronic MGP 464 DI - page 101

    5-9 MGP 464 • HTML Conguration and Control PRELIMINAR Y Border — In this section you can make selections from the following menus to specify parameters for the text label or for the border on the selected window . Y ou can specify a differ ent color for each window if desired. W indow Border Color: Select a color for the border around the en ...

  • Extron electronic MGP 464 DI - page 102

    HTML Conguration and Contr ol, cont’d MGP 464 • HTML Conguration and Control 5-10 PRELIMINAR Y Passwords scr een The Passwords scr een lets you assign an administrator and/or user password to control access to the MGP 464 W eb pages. N An administrator password must be in place befor e a user password can be assigned. N Passwords must con ...

  • Extron electronic MGP 464 DI - page 103

    5-11 MGP 464 • HTML Conguration and Control PRELIMINAR Y Email Alerts screen The Email Alerts screen enables you to set up the MGP 464 to automatically send e-mail alert messages when any of its settings are changed. Y ou can enter up to 64 e-mail addresses to alert r ecipients that an event has occurred. Y ou can also specify that SMTP (Simpl ...

  • Extron electronic MGP 464 DI - page 104

    HTML Conguration and Contr ol, cont’d MGP 464 • HTML Conguration and Control 5-12 PRELIMINAR Y 3 . Click the Save button to save the changes. The Save button changes back to Edit . Setting up SMTP authorization T o set the MGP to r equire SMTP authorization befor e accepting any e-mail, 1 . T o enable the SMTP authorization fields, click ...

  • Extron electronic MGP 464 DI - page 105

    5-13 MGP 464 • HTML Conguration and Control PRELIMINAR Y • Using the System Status W eb page: Select the Status tab on the MGP W eb page to display the System Status screen. The firmwar e version is on the third line (to the right of the part number) in the System Description section. Downloading the rmware T o obtain the latest version ...

  • Extron electronic MGP 464 DI - page 106

    HTML Conguration and Contr ol, cont’d MGP 464 • HTML Conguration and Control 5-14 PRELIMINAR Y C Uploading a file with an extension other than .S19 may cause the unit to stop functioning. 3 . Open the firmware file. Its name appears in the field below the Curr ent Firmware V ersion on the Firmware Upgrade scr een. 4 . Click the Upload ...

  • Extron electronic MGP 464 DI - page 107

    5-15 MGP 464 • HTML Conguration and Control PRELIMINAR Y Uploading les Names of les to be uploaded to the MGP 464 must contain only valid alphanumeric characters and underscores. No spaces or special characters (symbols) are allowed. T o upload files from the server , 1 . Click the Browse button to the right of the file name field. 2 ...

  • Extron electronic MGP 464 DI - page 108

    HTML Conguration and Contr ol, cont’d MGP 464 • HTML Conguration and Control 5-16 PRELIMINAR Y Using the Contr ol Page The screens that you can access thr ough the Control page enable you to configure the windows and images, select inputs, and manage window and input presets. Picture Contr ols screen The Picture Contr ols screen allows y ...

  • Extron electronic MGP 464 DI - page 109

    5-17 MGP 464 • HTML Conguration and Control PRELIMINAR Y Auto — Click this button to perform an automatic image adjustment to the selected window . The MGP measur es where the active area starts and stops, and adjusts input sampling accordingly , so that the image fills the window . When you click Auto , the processor measur es the sync fre ...

  • Extron electronic MGP 464 DI - page 110

    HTML Conguration and Contr ol, cont’d MGP 464 • HTML Conguration and Control 5-18 PRELIMINAR Y Window Controls The W indow Controls section contains ve sets of contr ols that enable you to make some adjustments to the selected window on the display . In the Horizontal and V ertical Center and Size elds, you can make adjustments by e ...

  • Extron electronic MGP 464 DI - page 111

    5-19 MGP 464 • HTML Conguration and Control PRELIMINAR Y Horizontal Start Location — Specify the distance in pixels from the left edge of the selected input’s total video display area to the left edge of its active ar ea. The default is 128. V ertical Start Location — Specify the distance in lines from the top edge of the selected input? ...

  • Extron electronic MGP 464 DI - page 112

    HTML Conguration and Contr ol, cont’d MGP 464 • HTML Conguration and Control 5-20 PRELIMINAR Y Presets scr een On the Presets scr een, you can name, save and recall window presets; and save and recall input pr esets. Presets scr een The Presets scr een is divided into the following sections: Window Presets A window preset is a file conta ...

  • Extron electronic MGP 464 DI - page 113

    5-21 MGP 464 • HTML Conguration and Control PRELIMINAR Y Default presets The MGP 464 is deliver ed with 30 different default window pr esets, which are stored in the MGP’s 128 pr eset memory locations. (Because there are mor e memory locations than presets, each default pr eset is stored in at least two locations.) The following figure show ...

  • Extron electronic MGP 464 DI - page 114

    HTML Conguration and Contr ol, cont’d MGP 464 • HTML Conguration and Control 5-22 PRELIMINAR Y Saving (creating) a window pr eset T o save all the current window settings as a pr eset, 1 . From the Select Pr eset menu, select the preset number to which you want to save the current settings for all the windows. 2 . Click Save Preset. Recal ...

  • Extron electronic MGP 464 DI - page 115

    5-23 MGP 464 • HTML Conguration and Control PRELIMINAR Y In the Input Presets section, you can do the following: Saving (creating) an input pr eset T o save all the settings for the currently selected input as a pr eset, 1 . Select a W indow Selection radio button to specify the window whose group of settings for the current input will be save ...

  • Extron electronic MGP 464 DI - page 116

    HTML Conguration and Contr ol, cont’d MGP 464 • HTML Conguration and Control 5-24 PRELIMINAR Y Uploading an image T o upload a bitmap image to the MGP , 1 . In the Image Index field, click Add . The Add Image field is displayed. Add Image field on the Image Settings screen 2 . Click Browse to open the Choose file window , and locate t ...

  • Extron electronic MGP 464 DI - page 117

    PRELIMINAR Y MGP 464 Multi-Graphic Pr ocessor 6 Chapter Six Special Applications Application 1: Connecting the MGP 464 to a Matrix Switcher Application 2: Connecting Multiple MGP 464s in Succession (Daisy-chaining) ...

  • Extron electronic MGP 464 DI - page 118

    Special Applications PRELIMINAR Y 6-2 MGP 464 • Special Applications This chapter describes some special types of applications that repr esent unique conditions. For the MGP 464 to operate pr operly in these situations, it is important that it be configured corr ectly . On the following pages, two application examples are described, along with t ...

  • Extron electronic MGP 464 DI - page 119

    PRELIMINAR Y 6-3 MGP 464 • Special Applications In this type of configuration, the following occurs: On the MGP , window 1 displays input 1, window 2 displays input 2, and so • forth. Input switches are made at the matrix switcher instead of at the MGP . • Input presets ar e recalled on the MGP to corr ectly set up the input coming • from ...

  • Extron electronic MGP 464 DI - page 120

    Special Applications, cont’d PRELIMINAR Y MGP 464 • Special Applications 6-4 5 . Repeat step 4 for every input on the matrix switcher that will be displayed on the output screen via the MGP , saving the settings for each input as Input Preset 2, 3, etc. N Each input pr eset must be saved with the same number as the input on the matrix switcher ...

  • Extron electronic MGP 464 DI - page 121

    PRELIMINAR Y 6-5 MGP 464 • Special Applications Using the MGP and the matrix switcher after the MGP is synchronized to the matrix switcher After you have performed step 6, above, be sure to do the following when using the MGP with the switcher: • Set up the inputs so that MGP window 1 always displays input 1, window 2 displays input 2, window 3 ...

  • Extron electronic MGP 464 DI - page 122

    Special Applications, cont’d PRELIMINAR Y MGP 464 • Special Applications 6-6 Application 2: Connecting Multiple MGP 464s in Succession (Daisy-chaining) By connecting multiple MGP 464s together in succession (“daisy-chaining”) via the DVI Output and DVI Background connectors, you can display up to 12 windows on the output screen. Y ou can co ...

  • Extron electronic MGP 464 DI - page 123

    PRELIMINAR Y 6-7 MGP 464 • Special Applications MGP 464 Unit B Output display with the 4 windows from unit B, and the 4 windows from unit A laid on top DVI output from first MGP output to DVI background input 1B 2B 3B 4B 1A 2A 3A 4A DVI out 4 video windows on output display Output display with the 4 windows from unit C, and the 4 windows from uni ...

  • Extron electronic MGP 464 DI - page 124

    Special Applications, cont’d PRELIMINAR Y MGP 464 • Special Applications 6-8 3 . Configure the output as follows: a . Set the output resolution/r efresh rate of the rst MGP to your output display’s native rate. N Do not set this unit to the DVI backgr ound rate. b . Set the output rates of the second and, if appr opriate, the third MGP to ...

  • Extron electronic MGP 464 DI - page 125

    PRELIMINAR Y MGP 464 Mult-Graphic Pr ocessor A Appendix A Specications, Part Numbers, and Accessories Specifications Part Numbers and Accessories ...

  • Extron electronic MGP 464 DI - page 126

    MGP 464 • Specications, Part Numbers, and Accessories A-2 Specications, Part Numbers, and Accessories PRELIMINAR Y Specications Number/signal type ..................... 4 VGA-UXGA DVI, RGBHV , RGBS, RGsB, RsGsBs, RGBcvS, component video (interlaced or progr essive), S-video, composite video 4 to 15 (congurable) component video (interl ...

  • Extron electronic MGP 464 DI - page 127

    A-3 MGP 464 • Specications, Part Numbers, and Accessories PRELIMINAR Y Control/r emote — processor/decoder/scaler Serial control port ......................... RS-232 or RS-422, 9-pin female D connector RS-232, 2.5 mm stereo mini jack Baud rate and protocol ................. 9600 baud, 8 data bits, 1 stop bit, no parity (default) Serial cont ...

  • Extron electronic MGP 464 DI - page 128

    Specications, Part Numbers, and Accessories, cont’d MGP 464 • Specications, Part Numbers, and Accessories A-4 PRELIMINAR Y Part Numbers and Accessories Included parts These items are included in each or der for an MGP 464: Included parts Replacement part number MGP 464 or MGP 464DI 60-771-01 60-771-02 Rack mounting brackets kit 70-155-01 ...

  • Extron electronic MGP 464 DI - page 129

    PRELIMINAR Y MGP 464 Multi-Graphic Pr ocessor B Appendix B Firmwar e Update Guide Determining the Firmware V ersion Downloading the Firmware Updating the Firmware ...

  • Extron electronic MGP 464 DI - page 130

    MGP 464 • Firmware Upgrade Guide B-2 Firmwar e Upgrade Guide PRELIMINAR Y Updates to the Extron MGP 464 Multi-Graphic Processor rmware ar e made available periodically via the Extron W eb site. If the need arises, you can replace the MGP 464’s main rmwar e via an IP connection without opening the unit. Determining the Firmwar e V ersion T ...

  • Extron electronic MGP 464 DI - page 131

    B-3 MGP 464 • Firmware Upgrade Guide PRELIMINAR Y Example of an Enter Network Password dialog box a . Enter the appropriate administrator passwor d in the Password eld. N A User name entry is not requir ed. b . If desir ed, select the check box to have the system input your password the next time you enter your MGP 464’s IP address. c . Clic ...

  • Extron electronic MGP 464 DI - page 132

    Firmwar e Upgrade Guide, cont’d MGP 464 • Firmware Upgrade Guide B-4 PRELIMINAR Y Using the Windows-based conguration software A third way to nd out the rmwar e version is to access the MGP 464 W indows- based configuration software. 1 . Open the conguration software. (See “W indows ® -based Control Software,” in chapter 4, fo ...

  • Extron electronic MGP 464 DI - page 133

    B-5 MGP 464 • Firmware Upgrade Guide PRELIMINAR Y Updating the Firmwar e After you have installed the new firmware on your computer , you must upload it to the MGP 464. Firmwar e uploads can be performed via a W eb browser , the MGP 464’s internal W eb pages, or the Firmware Loader software. The computer and the MGP 464 must both be connected ...

  • Extron electronic MGP 464 DI - page 134

    Firmwar e Upgrade Guide, cont’d MGP 464 • Firmware Upgrade Guide B-6 PRELIMINAR Y Firmware Upgrade scr een 4 . Click Browse to open the Choose file window , and locate the firmware file on your computer or server . The file extension must be .S19 . C Uploading a file with an incorrect extension may cause the unit to stop working. Choose ? ...

  • Extron electronic MGP 464 DI - page 135

    B-7 MGP 464 • Firmware Upgrade Guide PRELIMINAR Y 6 . Click the Upload button on the Firmware Update scr een to start the rmware update process. While the rmwar e is being uploaded, the Upload button changes to Uploading... ; and the LCD window on the MGP displays rst “Firmware Upload Please W ait!!!,” then “Firmware Reboot Please ...

  • Extron electronic MGP 464 DI - page 136

    Firmwar e Upgrade Guide, cont’d MGP 464 • Firmware Upgrade Guide B-8 PRELIMINAR Y 4 . Double-click on the firmware file icon. The firmwar e uploading process begins. While the rmware is loading, a pr ogress bar is displayed: Firmware update pr ogress bar 5 . When the rmware update is complete, the pr ogress bar closes. Updating using t ...

  • Extron electronic MGP 464 DI - page 137

    B-9 MGP 464 • Firmware Upgrade Guide PRELIMINAR Y Firmware Loader connection tabs • RS-232 tab — From the dr op-down menus, select the appropriate COM port number (obtained from your system administrator) and baud rate (the default is 9600). • TCP/IP tab — Enter your MGP’s IP addr ess (obtained from your system administrator), T elnet p ...

  • Extron electronic MGP 464 DI - page 138

    Firmwar e Upgrade Guide, cont’d MGP 464 • Firmware Upgrade Guide B-10 PRELIMINAR Y ...

  • Extron electronic MGP 464 DI - page 139

    Extr on’ s W arranty Extron Electr onics warrants this product against defects in materials and workmanship for a period of three years fr om the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extr on Electronics will, at its option, repair or r eplace said pr ...

  • Extron electronic MGP 464 DI - page 140

    © 2008 Extron Electr onics. All rights reserved. Ex tron US A - We st Headquar te rs + 800 .6 33 .9 87 6 Insid e U S A / C anad a O nl y +1 .7 14 .4 91 .1 50 0 +1 .7 14 .4 91 .1 51 7 FA X Ex tron US A - Eas t +8 00 .6 33 .9 87 6 Insid e U S A / C anad a O nl y +1 .9 19 .8 63 .1 79 4 +1 .9 19 .8 63 .1 79 7 FA X Ex tron EM EA + 800 .3 98 7. 66 73 In ...

Manufacturer Extron electronic Category DJ Equipment

Documents that we receive from a manufacturer of a Extron electronic MGP 464 DI can be divided into several groups. They are, among others:
- Extron electronic technical drawings
- MGP 464 DI manuals
- Extron electronic product data sheets
- information booklets
- or energy labels Extron electronic MGP 464 DI
All of them are important, but the most important information from the point of view of use of the device are in the user manual Extron electronic MGP 464 DI.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Extron electronic MGP 464 DI, service manual, brief instructions and user manuals Extron electronic MGP 464 DI. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Extron electronic MGP 464 DI.

A complete manual for the device Extron electronic MGP 464 DI, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Extron electronic MGP 464 DI by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Extron electronic MGP 464 DI.

A complete Extron electronic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Extron electronic MGP 464 DI - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Extron electronic MGP 464 DI, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Extron electronic MGP 464 DI, that we can find in the current document
3. Tips how to use the basic functions of the device Extron electronic MGP 464 DI - which should help us in our first steps of using Extron electronic MGP 464 DI
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Extron electronic MGP 464 DI
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Extron electronic MGP 464 DI in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Extron electronic MGP 464 DI?

Use the form below

If you did not solve your problem by using a manual Extron electronic MGP 464 DI, ask a question using the form below. If a user had a similar problem with Extron electronic MGP 464 DI it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)