    128-7401 1 of 24 Page 1 Model APS-997 Owner ’s Manual IMPORT ANT ! In order to provide you with the highest level of security to your vehicle, this system is equipped with selectable manual override circuitry . It is possible that you will need to override you security system if the transmitter becomes lost, or inoperative due to battery failure. ...

  • Univex APS-997 - page 2

    128-7401 2 of 24 Page 2 ! Protected Push Button V alet/Override Switch ! 7-Function LED-Arm / Disarm / Zone 1 / Zone 2 / Zone 3 / V alet / Arming ! Intrusion Alert With Memory ! Instant Siren Activation ! Starter Disable Output ! Additional Engine Immobilizer Output, (Optional Relay Required) ! True Last Door Arming (Hardwire Only) ! Defective Zone ...

  • Univex APS-997 - page 3

    128-7401 3 of 24 Page 3 known as a code grabber , which will receive and store the signal from your keychain transmitter and re-transmit at a later time to disarm your system. Y our Keeloq Code Hopping transmitters will change their signal every time the button is pressed, so when a thief grabs then re-transmits your signal, the alarm system will n ...

  • Univex APS-997 - page 4

    128-7401 4 of 24 Page 4 " The dash mounted LED begins to flash slowly . " Parking Lights flash one time. " Siren will not sound. If the siren "chirped" three times, sometime after arming, the exclusive delayed dome light learn circuit has been programmed and the system detected a open entry point after the learned delay exp ...

  • Univex APS-997 - page 5

    128-7401 5 of 24 Page 5 started. " Any mild impact to the vehicle’s glass will cause the alarm to sound a short series of warning tones. " Any strong impact to the vehicle’s glass will cause the alarm to trigger for the full 30 second alarm cycle. NOTE: If the optional interior illumination circuit was installed, the interior light wi ...

  • Univex APS-997 - page 6

    128-7401 6 of 24 Page 6 automatically . Open any door to suspend the automatic arming. " Parking Lights flash two times. If the parking lights flashed three times, then the alarm was triggered in your absence. Before turning the key on, examine the LED to identify which zone was triggered. " Siren will not sound. If the siren sounds 4 chi ...

  • Univex APS-997 - page 7

    128-7401 7 of 24 Page 7 LED turns on solid. The system will remain in the valet mode. 3. T o return to normal operation, press and release the pushbutton switch any time the ignition is on. NOTE: Always remember to return the system to normal operation. This will ensure t ha t t he vehicle remains protected at all times. MANUALL Y OVERRIDING YOUR S ...

  • Univex APS-997 - page 8

    128-7401 8 of 24 Page 8 T o Change the code from the factory pre-assigned code of 1 1 to “52” you would do the following: 1. Disarm the system by use of the transmitter or by use of the emergency override sequence. 2. Turn the ignition switch to the on position. 3. Within 10 seconds, press and release the valet/override switch, 3 times. 4. With ...

  • Univex APS-997 - page 9

    128-7401 9 of 24 Page 9 1. Turn the ignition key on then off. 2. Within 10 seconds, press and release valet switch three times. 3. If the chirps were on before you started, then you will hear two chirps indicat- ing they have been turned off. If the chirps were off before you started, then you will hear one chirp indicating they have been turned on ...

  • Univex APS-997 - page 10

    128-7401 10 of 24 Page 10 In this mode, the pre-detect chirps will change from six pre-warning tones to a full 10 seconds of warning chirps. The full detect trigger duration will be reduced from 30 seconds to 15 seconds. NOTE: Setting the stage of the shock sensor will be effective for one arming cycle only . Once the system has been disarmed, the ...

  • Univex APS-997 - page 11

    128-7401 11 of 24 Page 11 monoxide fumes which can be harmful or fatal if prolonged exposure occurs. DO NOT remote start the vehicle if it is garaged. T o Remote S tart The V ehicle: Press and release the programmed channel of your keychain transmitter two times within 2 seconds. The vehicle will start and remain running for the pre- programmed 5, ...

  • Univex APS-997 - page 12

    128-7401 12 of 24 Page 12 the second channel button of your keychain transmitter 4 times). The parking lights will flash and the siren will chirp 4 times indicating the timed start mode is activated. CANCELING THE AUTOMA TIC ST ART UP TIMER T o cancel the automatic start up timer do one of the following; 1. S tart the vehicle manually with the use ...

  • Univex APS-997 - page 13

    128-7401 13 of 24 Page 13 # Remote Car S tarter # Remote Window Closure # Remote Garage Door Interface T o remotely operate the device indicated, momentarily press, or press and hold the appropriate transmitter button(s) as indicated above. ADDITIONAL REMOTE FUNCTION ( CHANNEL 6 ) Channel 6 is an alternate output that can be controlled by the unloc ...

  • Univex APS-997 - page 14

    128-7401 14 of 24 Page 14 T o activate the turbo timer: Anytime the engine is running for more than 15 seconds: 1) Place the the gear selector in park. 2) Set the parking, (hand), brake. 3) Be certain your foot is off the brake pedal. 4) Press the program/Push-Button switch 2 times within 5 seconds. The parking lights will flash two times indicatin ...

  • Univex APS-997 - page 15

    128-7401 15 of 24 Page 15 When the Key Icon Button is pressed 2 times in succession The three puffs of smoke are displayed on the LCD screen while the vehicle is running. The exhaust indication will flash and the hour glass will indicate count down timer based on the 5, 10, 15, or 20 minute run time set up by your installation center . When the uni ...

  • Univex APS-997 - page 16

    128-7401 16 of 24 Page 16 Triggered and entry attempt was made to the vehicles glass, or the vehicle has been hit or bumped hard enough to cause a response from the vibration detector . ADDITIONAL ICONS THA T MA Y BE DISPLA YED ARE: If the arm/disarm chirp tones have been turned off at the ve- hicle, when you arm, or disarm, the display will indica ...

  • Univex APS-997 - page 17

    128-7401 17 of 24 Page 17 ADDITIONAL REMOTE FEA TURES: The two way remote control unit allows you to access status information from the vehicle, check temperature, light the display , toggle the transmitter from beep tones to vibrate mode, initiate daily start timer , and temperature start. Selection of these and other features are shown below: NOT ...

  • Univex APS-997 - page 18

    128-7401 18 of 24 Page 18 Note this feature must be activated at the vehicle at the prescribed time. Once activated at the vehicle, you can toggle the feature on simultaneously pressing the Lock + Option buttons of the transmitter . The 24 hour icon will appear and the transmitter will emit a tone confirming the feature is active. Note: the unit wi ...

  • Univex APS-997 - page 19

    128-7401 19 of 24 Page 19 Battery Indicator: Y our transmitter has a battery indicator that is shown in the upper right corner of the screen as shown left. This icon indicates a new battery shown with 3 bars. As the battery deteriorates, the bars will disap- pear . 1 bar indicates the battery should be replaced. Replace battery with a fresh 1.5V AA ...

  • Univex APS-997 - page 20

    128-7401 20 of 24 Page 20 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Univex APS-997 - page 21

    128-7401 21 of 24 Page 21 ...

  • Univex APS-997 - page 22

    128-7401 22 of 24 Page 22 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Univex APS-997 - page 23

    128-7401 23 of 24 Page 23 APS 997 SYSTEM FUNCTIONS A T A GLANCE DASH LED INDICA TORS RAPID FLASHING = P ASSIVE ARMING/ACTIVE REARMING SLOW FLASHING = ARMED OF F = DISARMED ON SO LI D = V ALET MODE 3 FLASH...P AUSE = INTRUSION ZONE 3 2 FLASH...P AUSE = INTRUSION ZONE 2 1 FLASH...P AUSE = INTRUSION ZONE 1 SIREN CHIRP INDICA TORS 1 CHIRP * = A R M 2 C ...

  • Univex APS-997 - page 24

    128-7401 24 of 24 Page 24 © 2005 Audiovox Electronics Corp., 150 Marcus Blvd., Hauppauge, NY 11788 128-7401 ...

Manufacturer Univex Category Remote Starter

Documents that we receive from a manufacturer of a Univex APS-997 can be divided into several groups. They are, among others:
- Univex technical drawings
- APS-997 manuals
- Univex product data sheets
- information booklets
- or energy labels Univex APS-997
All of them are important, but the most important information from the point of view of use of the device are in the user manual Univex APS-997.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Univex APS-997, service manual, brief instructions and user manuals Univex APS-997. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Univex APS-997.

Similar manuals

A complete manual for the device Univex APS-997, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Univex APS-997 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Univex APS-997.

A complete Univex manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Univex APS-997 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Univex APS-997, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Univex APS-997, that we can find in the current document
3. Tips how to use the basic functions of the device Univex APS-997 - which should help us in our first steps of using Univex APS-997
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Univex APS-997
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Univex APS-997 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Univex APS-997?

Use the form below

If you did not solve your problem by using a manual Univex APS-997, ask a question using the form below. If a user had a similar problem with Univex APS-997 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)