Manual Bryant 213A

32 pages 0.91 mb
Download

Go to site of 32

Summary
  • Bryant 213A - page 1

    Pr oduct Dat a Model 213A Lega cy t -- RNC S erie s Heat Pump wit h Puron r Refrigerant Si zes 018 to 060 1 - - 1 / 2 To 5 N o m i n a l To n s Fig. 1 – 213A Brya nt’ s heat pum ps wit h Puron r r efr iger ant provi de a col lec tion of features un match ed b y an y oth er family o f eq uip men t. Th e 213A ha s be en de si gned u tilizing B ry ...

  • Bryant 213A - page 2

    2 MODEL NUMBER NOMENCLA T URE 1 2 34 5 6 7 8 9 1 0 1 11 2 1 4 N N N A A/N N N N N A/N A/N N A 21 3 A N A 0 3 6 0 0 0 0 Pro duct Fa mi ly Tie r SEER Major Series Volt age V ariations Cooling Capaci ty Open Op en Open Minor Series 2=HP 1= Leg acy RNC 3=13 SEER A=P uron N= 208 - - - 230 - - - 1 or 208/230 - - - 1 A = Standard 0=Not Defi ned 0=Not Defi ...

  • Bryant 213A - page 3

    3 PHYS ICAL DA T A UNIT SIZE SER IES 018 - - - A 024 - - - A 030 - - - A 036 - - - A 042 - - - A 048 - - - A 060 - - - A Operat ing Weig ht (lb ) 146 162 203 207 246 263 279 Shippin g Weight (lb) 169 189 235 239 278 293 311 Compressor T ype Scroll REFRIGERAN T Puron ® (R - - - 410A) Cont rol TXV (Puro n Hard Shutoff) Charge ( lb) 5.25 5.9 7.6 7.65 ...

  • Bryant 213A - page 4

    4 ACCESSO RIES ORDER NUM BER DES CRIPT ION 018 - - - A 024 - - - A 030 - - - A 036 - - - A 042 - - - A 048 - - - A 060 - - - A HC34GE239 BALL BEARING M O TOR X HC34GE240 BALL BEARING M O TOR X X HC38GE228 BALL BEARING M O TOR X HC40GE226 BALL BEARING M O TOR X HC40GE228 BALL BEARING M O TOR X X KAACH1201AAA C RANKCASE HTR X S S KAACH1401AAA C RANKC ...

  • Bryant 213A - page 5

    5 ACCESSO R Y USAGE GUIDELINE ACCESSORY RE QUIRED F OR LOW - - - AMBIE NT COOLING A PPLICATIONS (Below 55 ° F) REQUI RED FOR LONG LINE APPLICATIONS* (Over 80 F t.) REQUI RED FOR SEA COA ST APPLICATIONS (Within 2 miles) Crankc ase Heat er Ye s Ye s No Evap orator F reeze Therm ost at Ye s No No Accum ulator Stan dar d Stand ard Sta nda rd Compresso ...

  • Bryant 213A - page 6

    6 Accesso ry Descrip tion an d Usag e (Listed A lph ab etical ly) - - CO NTI NUED 10. Outdoor A ir T empe rat ure Se nsor De si gne d for use wi th Brya nt Ther mosta ts l ist ed in t his publi cat ion. This de vice e nable s the ther mosta t to displ ay the outdoor te mper at ure. This devi ce al so is re quir ed to ena ble special th ermo stat fe ...

  • Bryant 213A - page 7

    7 ELECTRICAL DA T A UNI T SIZ E V/P H OPER VOL TS* CO MPR FAN MCA MIN WIRE SIZE { MIN WIRE SIZE { MAX LENGTH (ft.) } MAX LENGTH (ft.) } MAX FUSE** or CK T BRK AMPS MAX MIN LRA RLA FLA 60 ° C 75 ° C 60 ° C 75 ° C 018 - - - A 208 - - - 230/1 253 197 48 9.0 0.75 12 14 14 66 62 20 024 - - - A 58.3 12.8 0.75 16.8 14 14 47 45 25 030 - - - A 77 14.1 0 ...

  • Bryant 213A - page 8

    8 DIMENSIONS 213A ...

  • Bryant 213A - page 9

    9 213ANA BALANCE POINT WORKSHEET 0 10 20 30 40 50 60 70 80 - - 1 0 0 1 02 03 04 05 06 07 08 0 OUTDOOR TEMPERA TURE , ºF BUILDI NG HEA T LOSS, UNIT I NTEGRA TED HEA TI NG CAP ACI TY , MBTUH 0.0 2.9 5.9 8.8 11 . 7 14.6 17.6 20.5 23.4 kW 213ANA024A FY4A NF024 213RNA030A FY4A NF030 213RNA036A FY4A NF042 A05007 213ANA042A FY4A NF042 213ANA060A FY4A NB0 ...

  • Bryant 213A - page 10

    10 COMBINA TION RA TINGS Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 018 - - - A *FY4ANF018 17,100 TDR&TXV 13.00 10.50 18,000 3.36 10,900 2.24 7.7 FF1ENP018 17,100 TDR&TX ...

  • Bryant 213A - page 11

    11 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 024 - - - A CNPH*2417A** 22,800 TDR&TXV 14.00 11.60 23,600 3.72 14,400 2.62 8.5 315(A,J)AV04809 ...

  • Bryant 213A - page 12

    12 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 030 - - - A FX4CNF030 29,600 TDR&TXV 14.00 10.80 31,400 3.60 21,000 2.66 8.5 FY4ANF036 29,600 T ...

  • Bryant 213A - page 13

    13 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 030 - - - A CSPH*3012A* * 29,200 TDR&TXV 14.00 11.00 30,800 3.50 20,600 2.64 8.3 315(A, J)AV066 ...

  • Bryant 213A - page 14

    14 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 036 - - - A CNPH*3617A** 33,400 TXV 13.00 10.50 35,600 3.44 22,000 2.38 7.9 CNPH*4221A** 33,600 TDR ...

  • Bryant 213A - page 15

    15 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 042 - - - A CAP**4221A** 40,000 TDR&TXV 14.00 11.20 41,000 3.50 25,200 2.52 8.1 315(A,J)AV06011 ...

  • Bryant 213A - page 16

    16 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 042 - - - A CNPV*4824A** 40,500 TDR&TXV 13.50 11.20 41,000 3.60 25,400 2.52 8.2 355AAV042040 CN ...

  • Bryant 213A - page 17

    17 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 048 - - - A CNPH*4821A** 45,000 TXV 13.00 10.80 49,000 3.68 30,400 2.60 8.4 CNPH*6024A** 46,500 TDR ...

  • Bryant 213A - page 18

    18 DET AILED COOLING CAP ACITIES EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * T ...

  • Bryant 213A - page 19

    19 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal Syste ...

  • Bryant 213A - page 20

    20 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal Syste ...

  • Bryant 213A - page 21

    21 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal Syste ...

  • Bryant 213A - page 22

    22 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal Syste ...

  • Bryant 213A - page 23

    23 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal Syste ...

  • Bryant 213A - page 24

    24 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal Syste ...

  • Bryant 213A - page 25

    25 HEA T PUMP HEA TING PERFORMANCE INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- ...

  • Bryant 213A - page 26

    26 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t ...

  • Bryant 213A - page 27

    27 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t ...

  • Bryant 213A - page 28

    28 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t ...

  • Bryant 213A - page 29

    29 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t ...

  • Bryant 213A - page 30

    30 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t ...

  • Bryant 213A - page 31

    31 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t ...

  • Bryant 213A - page 32

    32 GUIDE SPECIFICA TIONS GENERAL System Description Outdoor- - mounted, air- -cooled, split - -system heat pump unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor , an air - - cooled coil, propeller - -type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Un ...

Manufacturer Bryant Category Heat Pump

Documents that we receive from a manufacturer of a Bryant 213A can be divided into several groups. They are, among others:
- Bryant technical drawings
- 213A manuals
- Bryant product data sheets
- information booklets
- or energy labels Bryant 213A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bryant 213A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bryant 213A, service manual, brief instructions and user manuals Bryant 213A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bryant 213A.

Similar manuals

A complete manual for the device Bryant 213A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bryant 213A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bryant 213A.

A complete Bryant manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bryant 213A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bryant 213A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bryant 213A, that we can find in the current document
3. Tips how to use the basic functions of the device Bryant 213A - which should help us in our first steps of using Bryant 213A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bryant 213A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bryant 213A in a specific country, if it was not possible to solve the problem on our own.