  • Bryant 556A - page 1

    A97272 This product meets GREEN SEAL criteria for manufac- turing, energy efficiency, sound levels and packaging. It contains no CFCs or HCFCs. As an ENERGY STAR SM Partner, Bryant Heating & Cooling Sys- tems has determined that this prod- uct meets the ENERGY STAR guidelines for energy efficiency. M A N U F A C T U R E R C E R T I F I E D T O ...

  • Bryant 556A - page 2

    ACCESS PANEL 1 1 / 4 "  1. Allow 30 in. clearance to service end of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. Minimum outdoor operating ambient in cooling mode is 55 ° F (unless low-ambient control is used) max 125 ° F. 2. Series designation is the 14th posi ...

  • Bryant 556A - page 3

    TESTED COMBINATION RATINGS* UNIT SIZE-SERIES INDOOR MODEL TOTAL CAPACITY BTUH SEER EER Factory- Supplied Enhance- ment Standard Rating Bryant Gas Furnace or Accessory TDR† Accessory TXV‡ 024-A CJ5A/CK5A/CK5BA036 26,600 TXV — 14.00 — 12.00 030-A CJ5A/CK5A/CK5BA042 30,500 TXV — 14.10 — 12.00 036-A CJ5A/CK5A/CK5BA048 36,500 TXV — 14.10 ? ...

  • Bryant 556A - page 4

    SPECIFICATIONS UNIT SIZE-SERIES 024-A 030-A 036-A 042-A Operating Weight (Lb) 291 291 291 291 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1 Operating Voltage Range* 187–253 Compressor— Rated Load Amps 13.5 14.7 15.4 18.6 Locked Rotor Amps 61.0 72.5 83.0 105.0 Condenser Fan Motor—Full Load Amps 0.75 0.75 1.10 1.10 Minimum Unit Ampacit ...

  • Bryant 556A - page 5

    ACCESSORY USAGE GUIDELINE ACCESSORY REQUIRED FOR LOW-AMBIENT APPLICATIONS (BELOW 55°F) REQUIRED FOR LONG-LINE APPLICATIONS* (OVER 50 FT) REQUIRED FOR BURIED LINE APPLICATIONS† (OVER 3 FT) REQUIRED FOR SEA COAST APPLICATIONS (WITHIN 2 MILES) Crankcase Heater Yes Yes Yes No Evaporator Freeze Thermostat Yes No No No Winter Start Control Yes‡ No N ...

  • Bryant 556A - page 6

    R-410A—QUICK REFERENCE GUIDE • R-410A refrigerant operates at 50-70 percent higher pressures than R-22. Be sure that servicing equipment and replacement components are designed to operate with R-410A. • R-410A refrigerant cylinders are rose colored. • R-410A refrigerant cylinders have a dip tube which allows liquid to flow out of cylinder i ...

  • Bryant 556A - page 7

    MATCHED SYSTEM HOMEPERFECT PLUS  CONTROL CENTER AIR CLEANER FURNACE FURNACE COIL AIR CONDITIONER VENT PERFECT HUMIDIFIER A97092 SYSTEM DESIGN 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operating air temperature without low-ambien ...

  • Bryant 556A - page 8

    A94328 SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including:  • Unit Familiarization • Maintenance  • Installation Overview • Operating Sequence A large selection of product, theory, and skills programs is availa ...

Manufacturer Bryant Category Air Conditioner

Documents that we receive from a manufacturer of a Bryant 556A can be divided into several groups. They are, among others:
- Bryant technical drawings
- 556A manuals
- Bryant product data sheets
- information booklets
- or energy labels Bryant 556A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bryant 556A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bryant 556A, service manual, brief instructions and user manuals Bryant 556A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bryant 556A.

A complete manual for the device Bryant 556A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bryant 556A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bryant 556A.

A complete Bryant manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bryant 556A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bryant 556A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bryant 556A, that we can find in the current document
3. Tips how to use the basic functions of the device Bryant 556A - which should help us in our first steps of using Bryant 556A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bryant 556A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bryant 556A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bryant 556A?

Use the form below

If you did not solve your problem by using a manual Bryant 556A, ask a question using the form below. If a user had a similar problem with Bryant 556A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)