Manual Omega Engineering OME-A8111

34 pages 0.95 mb
Download

Go to site of 34

Summary
  • Omega Engineering OME-A8111 - page 1

    www .omega.com e-mail: info@omega.com U ser ’ s Guide OME-A8111 ISA-BUS Multi-Functional Board Hardware Manual Shop online at ...

  • Omega Engineering OME-A8111 - page 2

    Servicing Nor th America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sale ...

  • Omega Engineering OME-A8111 - page 3

    OME-A-8111 Hardware User’s Manual OME-A-8111 Hardware Manual (ver.1.1, Jul/2003) 1 ...

  • Omega Engineering OME-A8111 - page 4

    Table of Contents 1. Introduction _________________________________________________________ 4 1.1 General D escriptio n ___________________________________________________ 4 1.2 Features _____________________________________________________________ 4 1.3 Specifica tions _________________________________________________________ 5 1.3.1 Power Consump ...

  • Omega Engineering OME-A8111 - page 5

    2.7.2 A/D Conversion Trigger M odes _______________________________________________ 22 2.7.3 A/D Transfer Modes ________________________________________________________ 23 2.7.4 Using software trigge r and pol ling transfer ______________________________________ 23 2.8 D/A Co nversion ______________________________________________________ 24 2.9 An ...

  • Omega Engineering OME-A8111 - page 6

    1. Introduction 1.1 General Description The OME-A-8111 is a high performance, multif unction (analog and digital I/O) board for the PC AT compatible computer with the ISA bus. The OME-A-8111 provides programmable gain (1, 2, 4, 8 and 16). The OM E-A-8111 contains a 12-bit ADC with up to 8 single-ended analog inputs. The maximum sample rate of the A ...

  • Omega Engineering OME-A8111 - page 7

    1.3 Specifications 1.3.1 Power Consumption z +5V @ 300 mA maxim um z +12V @ 60 mA maxim um z -12V @ 30 mA maxim um z Operating temperature: 0 ° C ~ 50 ° C 1.3.2 Analog Inputs z Channels: 8 single-ended z Input range: (software programmable) Bipolar: ± 5 V, ± 2.5 V, ± 1.25 V, ± 0.625 V, ± 0.3125 V z Input current: 250 nA max (125 nA typical) ...

  • Omega Engineering OME-A8111 - page 8

    1.3.4 DA Converter z Channels : 1 independent z Type : 12-bit multiplying , Analog device AD-7948 z Linearity : ± 1/2 bit z Output Range : 0~5 V or 0~10 V jumper selected , may be used with other AC or DC reference input. Maximum output lim it ± 10V z Output Drive : ± 5 mA z Settling Time : 0.6 microseconds to 0.01% for full scale step 1.3.5 Dig ...

  • Omega Engineering OME-A8111 - page 9

    1.3.7 Programmable Timer/Counter z Type : 82C54 -8 programmable tim er/counter z Counters: The counter1 and counter2 are cascaded as a 32-bit pacer timer. z Pacer output : 0.00047 Hz to 0.5 MHz z Input Gate : TTL compatible z Internal Clock : 2 MHz 1.3.8 Applications z Signal analysis z FFT & frequency analysis z Transient analysis z Production ...

  • Omega Engineering OME-A8111 - page 10

    2. Hardware Configuration 2.1 Board Layout BB ADS- 7 74 ON 123456 JP1 JP2 8111 SW1 987654 () A BASS ADDRESS A1 P1 A31 12 19 20 CN3 D/ C OUT CN2 D/ C I N 20 2 1 19 ANA I/0 CN1 VR1 VR2 VR3 VR4 VR5 OME-A-8111 Hardware Manual (ver.1.1, Jul/2003) 8 ...

  • Omega Engineering OME-A8111 - page 11

    2.2 I/O Base Address Setting The OME-A-8111 occupies 16 consecutive locations in I/O address space. The base address is set by DIP switch SW1. The default address is 0x220 as shown below: A 9 A 8 A 7 A 6 A 5 A 4 6 5 4 3 2 1 ON SW1 : BASE ADDRESS BASE ADDR A9 A8 A7 A6 A5 A4 200-20F OFF ON ON ON ON ON 210-21F OFF ON ON ON ON OFF 220-22F( ; ) OFF ON O ...

  • Omega Engineering OME-A8111 - page 12

    The PC I/O port mapping is given below. ADDRESS DEVICE ADDRESS DEVICE 000-1FF PC reserved 320-32F XT Hard Disk 200-20F Game/control 378-37F Parallel Printer 210-21F XT Expansion Unit 380-38F SDLC 238-23F Bus Mouse/Alt. Bus Mouse 3A0-3AF SDLC 278-27F Parallel Printer 3B0-3BF MDA/Parallel Printer 2B0-2DF EGA 3C0-3CF EGA 2E0-2E7 AT GPIB 3D0-3DF CGA 2E ...

  • Omega Engineering OME-A8111 - page 13

    2.4 I/O Register Address The OME-A-8111 occupies 16 consecutive PC I/O addresses. The following table lists the registers and their locations. Address Read Write Base+0 8254 Counter 0 8254 Counter 0 Base+1 8254 Counter 1 8254 Counter 1 Base+2 8254 Counter 2 8254 Counter 2 Base+3 Reserved 8254 Counter Control Base+4 A/D Low Byte D/A Channel 0 Low By ...

  • Omega Engineering OME-A8111 - page 14

    2.4.1 The 8254 Counter The 8254 Programmable tim er/counter has 4 registers from Base+0 through Base+3. For detailed programming inform ation about the 8254, please refer to Intel‘s “Microsystem Components Handbook”. Address Read Write Base+0 8254 Counter 0 8254 Counter 0 Base+1 8254 Counter 1 8254 Counter 1 Base+2 8254 Counter 2 8254 Counter ...

  • Omega Engineering OME-A8111 - page 15

    2.4.3 D/A Output Latch Register (WRITE) Base+4: Channel 1 D/A Low Byte Data Format Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 D7 D6 D5 D4 D3 D2 D1 D0 (WRITE) Base+5: Channel 1 D/A High Byte Data Format Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 X X X X D11 D10 D9 D8 D/A 12 bit output data: D11…D0, D11 = MSB, D0 = LSB, X = don‘t care T ...

  • Omega Engineering OME-A8111 - page 16

    2.4.5 Clear Interrupt Request (WRITE) Base+8: Clear Interrupt Request Format Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 X X X X X X X X X = don‘t care, XXXXXXXX = any 8 bit data is valid If OME-A-8111 is working in the interrupt transfer mode, an on-board hardware status bit will be set after each A/D conversion. This bit must be cleared by ...

  • Omega Engineering OME-A8111 - page 17

    2.4.7 A/D Multiplex Control Register (WRITE) Base+A : A/D Multiplexer Control Register Format Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 X X X X X D2 D1 D0 A/D input channel selection data =3 bits: D2...D0, D2=MSB, D0=LSB, X=don‘t care Channel Bit_2 Bit_1 Bit_0 0 0 0 0 1 0 0 1 2 0 1 0 3 0 1 1 4 1 0 0 5 1 0 1 6 1 1 0 7 1 1 1 NOTE: The settlin ...

  • Omega Engineering OME-A8111 - page 18

    2.4.8 A/D Mode Control Register (WRITE) Base+B : A/D Mode Control Register Format Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 X SI2 SI1 SI0 X D2 D1 D0 X=don‘t care Mode Select Trigger Type Transfer Type D2 D1 D0 Software Trig Pacer Trig Software Interrupt 0 0 0 Select X Select X 0 0 1 Select X Select X 0 1 0 X Select X X 1 1 0 X Select Select ...

  • Omega Engineering OME-A8111 - page 19

    The pacer trigger can control the sampling rate very precisely. So the converted data can be used to reconstruct the waveform of the analog input signal . In pacer trigger mode, the pacer timer will periodically generate trigger signals to the A/D converter. This converted data can be transfer to the CPU by polling or interrupt or DMA transfer meth ...

  • Omega Engineering OME-A8111 - page 20

    2.4.10 D/O Output Latch Register (WRITE) Base+D: D/O Output Latch Low Byte Data Format Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 D7 D6 D5 D4 D3 D2 D1 D0 (WRITE) Base+E: D/O Output Latch High Byte Data Format Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 D15 D14 D13 D12 D11 D10 D9 D8 D/O 16 bits output data: D15...D0, D15=MSB, D0=LSB The OME ...

  • Omega Engineering OME-A8111 - page 21

    2.5 Digital I/O The OME-A-8111 provides 16 digital input channels and 16 digital output channels. All levels are TTL compatible . The connections diagram and block diagram are given below: Read Read D0...D7 Base+D Base+E D0...D7 D8...D15 1...8 9...16 Output Latch Register Output Latch Register CN3 17...18 DGND DGND DO TTL 16-Channel Isolated Input ...

  • Omega Engineering OME-A8111 - page 22

    2.6 8254 Timer/Counter The 8254 Programmable tim er/counter has 4 registers from Base+0 through Base+3. For detailed programming inform ation about 8254, please refer to Intel‘s “Microsystem Components Handbook”. The block diagram is as below. Cin: clock input Cout: clock output INTCLK: internal clock Cin Gate Cout Counter 0 Cin Gate Cout Cou ...

  • Omega Engineering OME-A8111 - page 23

    2.7 A/D Conversion This section explains how to perfor m A/D conversions. The A/D conversion can be performed by software trigger by pacer trigger. At the end of the A/D conversion, it is possible to transfer data by polling and interrupt before using the A/D conversion func tion; users should notice the following issues: z A/D data register, BASE+ ...

  • Omega Engineering OME-A8111 - page 24

    2.7.1 A/D conversion flow Then the user must decide which A/D convers ion m ode will be used. The software driver supports three different modes. The user can control the A/D conversion by polling mode very easily (sec. 2.4.9) . It is recommended to use the softwa re driver if using interrupt or DMA mode. The analog input signals come from CN1. The ...

  • Omega Engineering OME-A8111 - page 25

    2.7.3 A/D Transfer Modes OME-A-8111 supports two transfer m odes. 1 : polling transfer : This mode can be used with all trigger mode s. Detailed information is given in section 2.4.8.The software scans A/D high byt e data register, BASE+5, until READY_BIT=0.The low byte data is also ready in BASE+4. 2 : interrupt transfer : This mode can be used wi ...

  • Omega Engineering OME-A8111 - page 26

    2.8 D/A Conversion The OME-A-8111 provides two 12-bit D/ A converters. Before using the D/A conversion function, user should notice the following issues: z D/A output register, BASE+4/BASE+5/BASE+6/BASE+7 (sec. 2.4.3) . z JP1/JP2 selects internal/external reference voltage (sec. 2.4.1) . NOTE: The DA output latch registers are de signed as a “dou ...

  • Omega Engineering OME-A8111 - page 27

    2.9 Analog Input Signal Connection FIG 1: Connecting analog input configuration A/D CHn OME-A-8111 AGND A/D CH0 Es Signal Shielding z Signal shielding connections are shown in Fig1. z Use single-point connection to frame ground (not AGND or DGND) Frame Ground OME-A-8111 AGND DGND Vin OME-A-8111 Hardware Manual (ver.1.1, Jul/2003) 25 ...

  • Omega Engineering OME-A8111 - page 28

    2.10 Pin Assignment The OME-A-8111 provides three connect ors. Connect 1, CN1 functions for analog input & analog output input. Connector 2, CN2, f unctions as 16 digital outputs. Connector 3, CN3, function as a digital output. CN1/CN2/CN3 Pin Assignment CN1: Analog input/Analog output /Connect Pin Assignment. Pin Number Description Pin Number ...

  • Omega Engineering OME-A8111 - page 29

    CN2: Analog input/Analog output /Connect Pin Assignment. Pin Number Description Pin Number Description 1 Digital Input 0/TTL 2 Digital Input 1/TTL 3 Digital Input 2/TTL 4 Digital Input 3/TTL 5 Digital Input 4/TTL 6 Digital Input 5/TTL 7 Digital Input 6/TTL 8 Digital Input 7/TTL 9 Digital Input 8/TTL 10 Digital Input 9/TTL 11 Digital Input 10/TTL 12 ...

  • Omega Engineering OME-A8111 - page 30

    2.11 Daughter Board The OME-A-8111 can be connected with many different daughter boards. The function of these daughter boards is described as follows. 2.11.1 OME-CA-4002 The OME-CA-4002 is a 37-pin D-Sub male connect or. It can directly connect to a 37-pin D-sub connector. 2.11.2 OME-DB-16P The OME-DB-16P is a 16-channel isolated digital input boa ...

  • Omega Engineering OME-A8111 - page 31

    3. Calibration The OME-A-8111 is calibrated to its best stat e of operation. For environments with large vibration, recalibration is recommended. Befo re calibrating the OME-A-8111, users should have the following items: z One 6-digit multi-meter. z One stable voltage source (4.9988V) z Diagnostic program: this program is included in the delivered ...

  • Omega Engineering OME-A8111 - page 32

    3.2 D/A Calibration Steps 1. Run A8111CAL.EXE 2. Connect D/A channel0,, pin 30 of CN1 to DVM 3. Adjust VR1 until DVM=5.0000V 4. Press “Enter" key 5. Adjust VR2 until DVM=0.0000V 3.3 A/D Calibration Steps 1. Press “Enter" key 2. Connot A/D Channel 0 to analog ground, CN1-Pin1 to CN1-Pin20. 3. Input stable DC 4.9988V to A/d channel 1, p ...

  • Omega Engineering OME-A8111 - page 33

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. O MEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s cust ...

  • Omega Engineering OME-A8111 - page 34

    M4029/0104 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, C ...

Manufacturer Omega Engineering Category Computer Hardware

Documents that we receive from a manufacturer of a Omega Engineering OME-A8111 can be divided into several groups. They are, among others:
- Omega Engineering technical drawings
- OME-A8111 manuals
- Omega Engineering product data sheets
- information booklets
- or energy labels Omega Engineering OME-A8111
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega Engineering OME-A8111.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega Engineering OME-A8111, service manual, brief instructions and user manuals Omega Engineering OME-A8111. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega Engineering OME-A8111.

A complete manual for the device Omega Engineering OME-A8111, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega Engineering OME-A8111 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega Engineering OME-A8111.

A complete Omega Engineering manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega Engineering OME-A8111 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega Engineering OME-A8111, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega Engineering OME-A8111, that we can find in the current document
3. Tips how to use the basic functions of the device Omega Engineering OME-A8111 - which should help us in our first steps of using Omega Engineering OME-A8111
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega Engineering OME-A8111
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega Engineering OME-A8111 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega Engineering OME-A8111?

Use the form below

If you did not solve your problem by using a manual Omega Engineering OME-A8111, ask a question using the form below. If a user had a similar problem with Omega Engineering OME-A8111 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)