Manual Omega Vehicle Security DAQ-16

30 pages 0.15 mb
Download

Go to site of 30

Summary
  • Omega Vehicle Security DAQ-16 - page 1

    INTERFACE CARDS FOR PERSONAL COMPUTERS DAQ-16 Data Acquisition Adapter for 16-bit ISA compatible machines Users Manual OMEGA ENGINEERING, INC. TEL: (203) 359-1660 One Omega Drive FAX: (203) 359-7700 P.O. Box 4047 Toll free: 1-800-826-6342 Stamford, CT 06907-4047 E-mail: das@omega.com htt p ://www.dasieee.com ...

  • Omega Vehicle Security DAQ-16 - page 2

    WARRANTY/DISCLAIMER OMEGA ENGI NEERING, INC. , w arrants this unit to be free of def ects in materials and w orkmanship for a perio d of 13 mont hs from the date of purchase. OMEGA w arranty adds an ad ditional one (1) month grace period to the normal one (1 ) year pr oduct w arr anty to co ver shipping and handling time. This ensures that OMEGA’ ...

  • Omega Vehicle Security DAQ-16 - page 3

    OMEGAnet  On-line Service: Internet e-mail: http://www.omega.com info@omega.com Servicing North America : USA : One Omega Drive, Box 4047 E-mail: info@omega.com ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 Canada : 976 Bergar E-mail: info@omega.com Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-68 ...

  • Omega Vehicle Security DAQ-16 - page 4

    United Kingdom : One Omega Drive, River Bend Technology Drive ISO 9002 Certified Northbank, Irlam, Manchester M44 5EX, England Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622 Toll Free in England: 0800-488-488 E-mail: info@omega.co.uk It is the policy of OM EGA to comply with al l worl dwide safety and EM C/EMI regulations that apply. OMEGA is consta ...

  • Omega Vehicle Security DAQ-16 - page 5

    Declaration of Conf orm ity Manufacturer's Name: Omega Engineering Inc. Manufacturer's Address: One Omega Drive Stamford, CT 06907-0047 Application of Council Directive: 89/336/EEC Standards to which Conformity is Declared: * EN50081-2 (EN55022, EN60555-2, EN60555-3) * EN50082-1 (IEC 801-2, IEC 801-3, & IEC 801-4) Type of Equipment: I ...

  • Omega Vehicle Security DAQ-16 - page 6

    Table of Contents 28 4.2 Programming the 8254 Counter/Timer ............................ 27 4.1.8 8254 Control Word/Status Register ................................... 27 4.1.7 Multi-Function Timer Register ....................................... 27 4.1.6 Clock Rate Register (high word) ..................................... 27 4.1.5 Clock Rate Regi ...

  • Omega Vehicle Security DAQ-16 - page 7

    List of Figures and Tables 25 Table 4-1. DAQ-16 Address Map .............................................. 15 Table 2-3. Jumper J4 Configuration ............................................ 13 Table 2-2. A/D Conversion Format Examples ................................... 10 Table 2-1. A/D Converter Configurations .................................... ...

  • Omega Vehicle Security DAQ-16 - page 8

    1. Introduction The DA Q-1 6 is a high s peed dat a ac quisit ion adap te r for IBM AT com pat ible mac hine s off eri ng ei ght d if fer ential anal og i nput channel s with 16- bit r esol ution, two anal og output channel s with 12-b it r esoluti on and four di gi tal i nput/output lines. Other f eature s of the DAQ-16 include: Analog to Digital ...

  • Omega Vehicle Security DAQ-16 - page 9

    1.2 DAQ-16 Specifications DACK 5, 6 , 7 DRQ 5, 6 , 7 DMA Levels: IRQ 2, 3, 4. 5, 6, 7, 10, 11, 12, 14, 15 Interrupt Levels: 0000H - FFFFH I/O Address Range: ISA 16-bit Bus Interface: 491.4mA 374.9 mA +12 volts --- --- -12 volts 1204.9mA 1069.0 mA +5 volts --- --- -5 volts I(ms) I(t) Power Supply Power Requirements: I(t) = Typical Current / I(ms) = ...

  • Omega Vehicle Security DAQ-16 - page 10

    2. Circuit Board Description and Configuration The ba se addres s of t he DA Q-1 6 is sele ct ed using s witch es SW1 and SW 2. The op erat ing mo de of t he DAQ-16 is co nt rolled by jump ers J1 th rough J7 , while DMA an d interru pt sele ctions ar e set wi th jumper s J 8 throug h J 11. Connections to ex ternal equi pment are made through the hi ...

  • Omega Vehicle Security DAQ-16 - page 11

    Figures 2-1 and 2-2 show the configuration options for jumpers J7 and J6. J7 J7 J7 1 3 2 4 2 4 2 4 1 3 1 3 Ga i n = 1 Gai n = 1 0 Gai n = 1 00 Figure 2-1. Jumper J7 Configuration 10 vo l t ra ng e 1 2 3 4 5 6 J6 5 vo l t ra ng e 1 2 3 4 5 6 J6 2.5 vol t r ange 4 5 6 1 2 3 J6 Figure 2-2. Jumper J6 Configuration WARNING: These settings are only sugge ...

  • Omega Vehicle Security DAQ-16 - page 12

    The final stage of the A/D converter circuit is the A/D converter IC . The co nverter must be co nfigur ed for u nipo lar o r bipolar inp ut vo ltages a nd for binary o r 2' s com plemen t dat a conversion. These options are selected using jumper J5 as shown in Figure 2-3 below. 4 5 6 1 2 3 J5 4 5 6 1 2 3 J5 4 5 6 1 2 3 J5 4 5 6 1 2 3 J5 Uni p ...

  • Omega Vehicle Security DAQ-16 - page 13

    +32,767 +32,767 +65,535 +65,535 +Vmax +16,384 0 +49,152 +32,768 +Vmax/2 0 -32,768 +32,768 0 0 -16,384 n/a +16,384 n/a -Vmax/2 -32,768 n/a 0 n/a -Vmax bipolar unipolar bipolar unipolar 2’s Complement 2’s Complement Binary Binary Voltage Table 2-2. A/D Conversion Format Examples In or der to calculate the actual input vol tage from the di gital & ...

  • Omega Vehicle Security DAQ-16 - page 14

    2.2 Digital to Analog Converters The di gi tal to an alog (D /A) se ction of the DA Q-16 consi sts of two i ndepe nden t 12-b it multi ply ing D /A converte rs, and tw o ind ependent two-stag e output ampl ifi ers. D igi tal data, (output to the D/A conver ter by the CPU), i s conver ted to an anal og voltag e by the D/A converter , a mpli fi ed by ...

  • Omega Vehicle Security DAQ-16 - page 15

    5 6 7 8 1 2 3 4 J4 Channel 1 gain Channel 1 select Channel 0 select Channel 0 gain Figure 2-5. Jumper J4 Configuration Table 2-3 lists configuration options for jumper J4. connect 4-8 open 4-8 connect 2-6 open 2-6 Gain = 1 Gain = 2 connect 3-7 open 3-7 connect 1-5 open 1-5 Bipolar Unipolar Channel 1 Channel 0 Table 2-3. Jumper J4 Configuration When ...

  • Omega Vehicle Security DAQ-16 - page 16

    2.4 Base Address The DAQ-16 uses 16 consec utiv e I/O address lo cation s in the range 0 t o 0FFFFH. Two six- positi on switches (SW1 and SW2) are used to select the base add ress. SW1 controls addres s lines A15 - A 10, and S W2 co nt rols A9 - A4. Addres s lines A3 - A0 are us ed internally by the DAQ-16 to select which register to access. When s ...

  • Omega Vehicle Security DAQ-16 - page 17

    2.5 Clock Selection The D AQ-1 6 is e quipped wi th a progr ammab le cl ock ci rcui t to pr oduce d ata sampl in g rate s independ ent from the clock rate o f the host co mputer. An onboard 8254 programmabl e inte rval time r, wi th a 10 MHz clock input and ei ther tw o or thr ee cascad ed 16-b i t timer s, provi d es the sampl i n g r a te. Thi s ...

  • Omega Vehicle Security DAQ-16 - page 18

    2.5.1 Internal Clock Sampling rates for the internal clock can be calculated using the following equation: t = 100ns * [N1*N2] or f = 10MHz / [N1*N2] wher e N1 is the low 1 6-b its of the clock di vid er and N2 is the high 1 6-b its of the clock divider. The following criteria must be met when selecting values for N1 and N2: 2 < N1 < 65,535 2 ...

  • Omega Vehicle Security DAQ-16 - page 19

    Whe n co nfigured fo r a 48-bit div ider, the first s ampling p eriod will be slightly lo nger th an the other s because the fi rst cl ock per iod is r equi red to l oad the i ni tial val ue of the multi-function timer. The following equation calculates the additional time of the first period: t = 100ns * [N1 * N2] add To m inimiz e the a moun t of ...

  • Omega Vehicle Security DAQ-16 - page 20

    When the mul ti- functi on time r is use d as a pr e-d i vid er, the fr equency of the ex ternal cl ock input may be var ied fr om DC to 10 MHz as l ong as the hi gh porti on of the cl ock is at l east 30ns and the low porti on is at least 5 0ns. E xcept f or the fi rst peri od, the sampl in g rate of the DAQ-1 6 will be the e xte rnal clock fre qu ...

  • Omega Vehicle Security DAQ-16 - page 21

    2.7 Direct Memory Access Di rect Me mory Acce ss (D MA) tra nsfe rs provi de a way of transf er ri ng da ta fr om the DAQ- 16's A/D converter in to the computer's memor y w ithout usi ng the Ce ntral Processi ng Unit (CPU). DMA capa bility e nable s o ther syst em so ftware to be e xecut ed while data is being input from the DAQ-16. The D ...

  • Omega Vehicle Security DAQ-16 - page 22

    2.8 Interrupts The DAQ-16 is capable of generating an interrupt from one of four sources: 1. End of conversion signal 2. DMA terminal count 3. Multi-function timer output 4. External interrupt input The i nterrupt source is softwar e selected through the D AQ-16 contr ol word r egi ster. The interrupt level is selected using the jumpers J10 and J11 ...

  • Omega Vehicle Security DAQ-16 - page 23

    3. External Connections The DAQ-16 is equipped with a high density 62-pin connector as shown in Figure 3-1. 2 - CH1+ 4 - CH2 - 6 - CH 4+ 8 - CH5- 10 - CH7+ 12 - AOUT0 14 - DOUT0 6 - DOUT3 18 - EXT TRIG 20 - DIN1 22 - CH0+ 24 - CH1- 26 - CH3+ 28 - CH4- 30 - CH6+ 32 - CH7- 34 - AOUT1 36 - DOUT1 38 - EXT INT 40 - DIN3 42 - DIN0 43 - CH0- 45 - CH2+ 47 ...

  • Omega Vehicle Security DAQ-16 - page 24

    CH0 -,CH0+ ,...,CH7-,C H7+ : Ana log inpu ts t o t he an alog to digit al c onv ert er. Am plitude and polar ity d epend upon jumper setting s. The i nput re sistance of these l ines i s 1.5K ohms typical. AOUT 0, A OUT1 : Ana log outputs from the d i gi tal to ana log conve rter s. Pol ari ty an d maximum ampl itud e d epend on the jumper settings ...

  • Omega Vehicle Security DAQ-16 - page 25

    4. Register Description and Programming The DAQ-16 us es 16 consecu tive I/ O address lo cations in the range 0 to FFFFH. The card ut ilizes thes e addre ss es fo r the regist ers list ed in Table 4-1 . (* indicat es regis ters loca te d in 8254 counter). Read/Write 8-bit 8254 Control Word/Status Register Base F * Read/Write 8-bit Multi-function Ti ...

  • Omega Vehicle Security DAQ-16 - page 26

    DMAEN - enables / disables DMA. When set, logic 1, DMA transfers are enabled. DMAC T - e nable s t he m ulti-c hanne l DM A capa bility o f th e DAQ -16. When s et, logic 1 , a termi nal count on the acti ve DMA channe l cause s DMA tr ansfer s to beg in on the "stand -b y" ch ann el. When clea red, lo gic 0, DM A tran sfers h alt when th ...

  • Omega Vehicle Security DAQ-16 - page 27

    4.1.2 Start of Conversion Register The start of conversion register is 16-bit write only and performs two functions: 1. Wh en co nfigured for inte rnal triggerin g, writing a "0" to th is regist er generat es the software trigger, starting the data conversion process. 2. Wr iting a "0" to th is regis ter at any t ime reset s t h ...

  • Omega Vehicle Security DAQ-16 - page 28

    4.2 Programming the 8254 Counter/Timer This section provides programming information for the 8254 co unter/timer as i mplemented on the DAQ-16. For more details on the 8254, consult the Intel Micro-Processor and Peripheral Handbook. To program any of the counters contained in the 8254 counter/timer, three steps are required: 1. Write the configurat ...

  • Omega Vehicle Security DAQ-16 - page 29

    Counter 1 - Clock rate register (high word) operating mode: 2 minimum count value: 2 configuration byte: 0 / 1 / 1 / 1 / 0 / 1 / 0 / 0 = 74H Example: Program the value 13A4H into the high word of the clock rate register. output 74H to base_address + 0FH output A4H to base_address + 0DH output 13H to base_address + 0DH Example: Program the value FFF ...

  • Omega Vehicle Security DAQ-16 - page 30

    DAQ-16 Users Manual Version 2.20 January 28, 1999 Part No. 940-0032-220 ...

Manufacturer Omega Vehicle Security Category Network Card

Documents that we receive from a manufacturer of a Omega Vehicle Security DAQ-16 can be divided into several groups. They are, among others:
- Omega Vehicle Security technical drawings
- DAQ-16 manuals
- Omega Vehicle Security product data sheets
- information booklets
- or energy labels Omega Vehicle Security DAQ-16
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega Vehicle Security DAQ-16.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega Vehicle Security DAQ-16, service manual, brief instructions and user manuals Omega Vehicle Security DAQ-16. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega Vehicle Security DAQ-16.

A complete manual for the device Omega Vehicle Security DAQ-16, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega Vehicle Security DAQ-16 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega Vehicle Security DAQ-16.

A complete Omega Vehicle Security manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega Vehicle Security DAQ-16 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega Vehicle Security DAQ-16, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega Vehicle Security DAQ-16, that we can find in the current document
3. Tips how to use the basic functions of the device Omega Vehicle Security DAQ-16 - which should help us in our first steps of using Omega Vehicle Security DAQ-16
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega Vehicle Security DAQ-16
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega Vehicle Security DAQ-16 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega Vehicle Security DAQ-16?

Use the form below

If you did not solve your problem by using a manual Omega Vehicle Security DAQ-16, ask a question using the form below. If a user had a similar problem with Omega Vehicle Security DAQ-16 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)