Manual Oregon Scientific TP391

18 pages 1.45 mb
Download

Go to site of 18

Summary
  • Oregon Scientific TP391 - page 1

    Pair of PMR446 T wo-W ay Personal Radios Model: TP391 USER MANUAL MANUALE D’USO MANUEL DE L ’UTILISA TEUR BEDIENUNGSANLEITUNG MANUAL DE USUARIO MANUAL DO USUÁRIO HANDLEIDING BRUKSANVISNING P/N:086L004722-016 REV.1 PAGE: 1/152 ...

  • Oregon Scientific TP391 - page 2

    EN C O N T E N T S Introduction ............................................................................................. 1 Key Features ........................................................................................... 1 Front view............................................................................................... 1 Back vi ...

  • Oregon Scientific TP391 - page 3

    1 EN INTRODUCTION Thank you for selecting the Oregon Scientic™ TP391as your product of choi ce. This prod uct is a port able, ea sy-to -use two -way rad io trans ceive r that you ca n use to con tact your fami ly and friend s at shopp ing mal ls, amu seme nt parks, sports events, beaches, forests and so on. Y ou can also use it as a vital comm ...

  • Oregon Scientific TP391 - page 4

    2 EN NO. DESCRIPTION FUNCTION 0 Antenna Receives and transmits signals 1 LED indicator Lights up red when transmitting a signal 2 Auto scans for available channel / Monitors current channel for activity 3 Scrolls through menu options / Locks and unlocks the keypad 4 Speaker Generates audible sound 5 Connection Slot pins into a desktop charger docki ...

  • Oregon Scientific TP391 - page 5

    3 EN BACK VIEW NO. DESCRIPTION FUNCTION 1 Battery door Remove to access battery compartment 2 Battery Uses lithium 3.7V -720mAh rechargeable compartment battery 3 Sends call tone to other users of the same frequency P/N:086L004722-016 REV.1 PAGE: 5/152 ...

  • Oregon Scientific TP391 - page 6

    4 EN L C D D I S P L A Y S Y M B O LS SYMBOL FUNCTION Channel number: Select between 8 channels CTCSS code: Adjust to minimize interference problems Dual W atch: Monitor 2 channels simultaneously Battery indicator: Provides battery status during operation Call tone: Page another user Keypad lock: Locks keypad to prevent accidental button activation ...

  • Oregon Scientific TP391 - page 7

    5 EN SAFETY AND CARE INSTRUCTIONS SAFETY PRECAUTIONS Please observe the following safety precautions when setting up and using this product. * LCD panel – The LCD panel is made of glass, and may break if the unit is dropped or impacted. * Heat sources – Keep the product away from heat sources such as radiators, stoves, heaters, and other heat-g ...

  • Oregon Scientific TP391 - page 8

    6 EN * Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary . * No naked ames, such as lighted candles, should be placed near the apparatus. * T o reduce the risk of electric shock, do not expose this application to rain or moisture. GETTING ST ARTED P O WE R T o insert t ...

  • Oregon Scientific TP391 - page 9

    7 EN T o charge the battery using the AC adapter: Charge the batte ry for 12 hours on the rst charge . After that, it should take 3 or less hours to char ge. The LCD backlig ht will be turned on when charging. The LED indicator will be turned on when battery is full. NOTE: 1. T o maintain the battery life of your two-way transceiver it is recomm ...

  • Oregon Scientific TP391 - page 10

    8 EN V O LU M E T o change the volume level: Use or to increase or decrease volume. RESET T o reset the unit: Remove the batteries for two minutes and insert them again. T ALK TO ANOTHER TRANSCEIVER For best transmission speak about 5 cm away from the radio and leave a short pause before speaking once you have pressed . T o talk to another transcei ...

  • Oregon Scientific TP391 - page 11

    9 EN K E YPA D L O C K T o avoid acciden tally changing the channel and the unit’s prefer red settings, you can lock the keypad. T o lock or unlock the keypad: Press and hold for 1.5 seconds. appears when the keypad is locked. NOTE: While the keypad is on you can still use the and keys. MENU OPTIONS T o access the Menu Options and change settings ...

  • Oregon Scientific TP391 - page 12

    10 EN 3. Press to conrm and move to the next setting or press to conrm the changes and exit the Menu Options. Settings will automatically be conrmed after 5 seconds if no key is pressed. SELECT A CHANNEL OR CTCSS The transmitter and receiver must be on the same channel using the same CTCSS code in order for you to communicate with another ...

  • Oregon Scientific TP391 - page 13

    1 1 EN C A LL TO N E T o alert other radios set to the same channel as you that you want to communicate with them, you can transmit a call tone to pre-warn them. T o change the call tone: 1. Press 3 times un til the number starts ashing. 2. Press a nd hold to change the tone. 3. Pre ss to conrm and exit the menu. Or , press to co nrm and g ...

  • Oregon Scientific TP391 - page 14

    12 EN T o change the VOX level: 1. Pre ss 4 tim es until the number starts ashing. 2. Press and hold or to change the VOX level. 3. Press to conrm and exit the menu. Or , press to conrm and go to the next Menu Option. LCD SYMBOL DESCRIPTION 0 VOX disabled 3 Low sensitivity – only audibly loud voices are transmitted (useful for noisy envi ...

  • Oregon Scientific TP391 - page 15

    13 EN DUAL W A TCH (DW) The Dual Watch feature allows you to monitor more than one channel simultaneously . T o set Dual Watch: 1. Press 6 times until “DW” appears and the channel number starts ashing. 2. Press and hold or to select a watch channel (1-8). 3. Pres s to c onrm and exit the menu. Or , press to conrm an d go to the next Me ...

  • Oregon Scientific TP391 - page 16

    14 EN T o stop auto-scan: Press . The unit will revert back to the original channel that was set prio r to scanning. NOTE: If you activate a scan while your code is set to 0, the radio will check for any activity on each channel, regardless of the code used on that channel. If you activat e a scan while the code is between 1 and 38, the radio will ...

  • Oregon Scientific TP391 - page 17

    15 EN SPECIFICA TIONS Operation frequency 446.00625 to 446.09375 MHz Channels 8 CTCSS Codes 38 standard codes Modulation type FM Microphone Internal / external condenser type Power supply 3.7V 720mAH Li-ion battery Sensitivity <= -1 19 dBm Noise squelch Auto VOX levels 3 Call tones 10 Audio output power 125mW Audio distortion < 5% RX signal t ...

  • Oregon Scientific TP391 - page 18

    16 EN ABOUT OREGON SCIENTIFIC Visit our website (www .oregonscientic.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children’s electronic learning products and games; projection clocks; health and tness gear; weather stations; and digital and conference phones. The websi te also inclu des contac t ...

Manufacturer Oregon Scientific Category Two-Way Radio

Documents that we receive from a manufacturer of a Oregon Scientific TP391 can be divided into several groups. They are, among others:
- Oregon Scientific technical drawings
- TP391 manuals
- Oregon Scientific product data sheets
- information booklets
- or energy labels Oregon Scientific TP391
All of them are important, but the most important information from the point of view of use of the device are in the user manual Oregon Scientific TP391.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Oregon Scientific TP391, service manual, brief instructions and user manuals Oregon Scientific TP391. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Oregon Scientific TP391.

A complete manual for the device Oregon Scientific TP391, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Oregon Scientific TP391 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Oregon Scientific TP391.

A complete Oregon Scientific manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Oregon Scientific TP391 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Oregon Scientific TP391, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Oregon Scientific TP391, that we can find in the current document
3. Tips how to use the basic functions of the device Oregon Scientific TP391 - which should help us in our first steps of using Oregon Scientific TP391
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Oregon Scientific TP391
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Oregon Scientific TP391 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Oregon Scientific TP391?

Use the form below

If you did not solve your problem by using a manual Oregon Scientific TP391, ask a question using the form below. If a user had a similar problem with Oregon Scientific TP391 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)