  • Honeywell DC300K-E - page 1

    Industrial Automation and Control, 110 Virginia Drive, Fort Washington, PA 19034 Printed in U.S.A. ■  Copyright 1997 Honeywell Inc. UDC3000 Versa-Pro Universal Digital Controller 51-52-03-07 2/97 Page 1 of 12 Specification Overview The UDC3000 Universal Digital Controller is Honeywell’s general purpose microprocessor-based, stand alone digit ...

  • Honeywell DC300K-E - page 2

    51-52-03-07 Page 2 Features, continued CE Mark- Conformity with 73/23/EEC, Low Voltage Directive and 89/336/EEC, the EMC Directive Moisture Resistant Front Panel - Capable of meeting NEMA 3 and IEC529 IP65 (i.e. hosedown) requirements. Timer - This standard feature pro- vides a configurable time period of 0 to 99 hours, 59 minutes. Alarm 1 is dedic ...

  • Honeywell DC300K-E - page 3

    51-52-03-07 Page 3 Output Types The following output types are available per the model selection guide: • Current output • Electromechanical relays • Solid state relays • Open collector output • Solid state relay (10 amp) externally mounted (optional) • Auxiliary current output (optional) Output Algorithms The UDC3000 is available with ...

  • Honeywell DC300K-E - page 4

    51-52-03-07 Page 4 ALM RSP OUT % 1 2 1 2 1 2 F C MAN FUNCTION SET UP LOWER DISPLAY MANUAL AUTO SETPOINT SELECT RUN HOLD DI Indicator definition when lit ALM - Alarm conditions exist DI - Digital Input active OUT - Control Relay 1 or 2 on Upper Display - Six Characters • Normal Operation - four digits dedicated to display the process variable • ...

  • Honeywell DC300K-E - page 5

    51-52-03-07 Page 5 Specifications Design CE Conformity (Europe) This product is in conformity with the protection requirements of the following European Council Directives: 73/23/EEC , the Low Voltage Directive, and 89/336/EEC , the EMC Directive. Conformity of this product with any other “CE Mark” Directive(s) shall not be assumed. Product Cla ...

  • Honeywell DC300K-E - page 6

    51-52-03-07 Page 6 Specifications (continued) Design (continued) Controller Output Types Current Output (Isolated) Range can be set anywhere between 0 to 21 mA, and as direct or reverse action. Resolution: 11 bits for 0 to 21 mA Accuracy: 0.5% full scale Temperature Stability: 0.1% F.S. / ˚C Load Resistance: 0 to 1000 ohms Electromechanical Relays ...

  • Honeywell DC300K-E - page 7

    51-52-03-07 Page 7 Specifications (continued) Design (continued) Auxiliary Linear Output (Optional) (Isolated) 21 mA dc maximum into a negative or positive grounded load or non-grounded load of 0 to 1000 ohms. Output range can be set anywhere between 0 to 21 mA, and as direct or reverse action. It can be configured to represent either Input, PV, Se ...

  • Honeywell DC300K-E - page 8

    51-52-03-07 Page 8 Specifications (continued) Environmental and Operating Conditions Parameter Reference Rated Operative Limits Transportation and storage Ambient Temperature 25 ± 3 ˚ C 77 ± 5 ˚ F 15 to 55 ˚ C 58 to 131 ˚ F 0 to 55 ˚ C 32 to 131 ˚ F -40 to 66 ˚ C -40 to 151 ˚ F Relative Humidity 10 to 55* 10 to 90* 5 to 90* 5 to 95* Vibra ...

  • Honeywell DC300K-E - page 9

    51-52-03-07 Page 9 General Reference Data Data Isolation (Functional) AC Power : is electrically isolated from all other inputs and outputs to withstand a HIPOT potential of 1900Vdc for 2 seconds per Annex K of EN61010-1. Analog Inputs and Outputs: are isolated from each other and all other circuits at 850Vdc for 2 seconds. Digital Input and Digita ...

  • Honeywell DC300K-E - page 10

    51-52-03-07 Page 10 Dimensions Panel Cutout ALM RSP OUT % 1 2 1 2 F C MAN PV 1 2 3 4 96 3.780 AL M % 1 2 1 2 1 2 F C M A N DI ALM RSP OUT % 1 2 1 2 F C MAN DI FUNCTION LOWER DISPLAY MANUAL AUTO SETPOINT SELECT SET UP HOLD 1 2 24 .945 Max Panel Thickness 10 .394 Max (2) 5.82 147.3 21.6 .850 .093 2.4 with optional rear cover 90.7 3.57 22073 +0.008 92 ...

  • Honeywell DC300K-E - page 11

    51-52-03-07 Page 11 Wiring Diagram 1 2 3 4 5 6 7 8 9 ALM 1 CTL 2 ALM 2 CTL 1 4-20 MA 10 11 12 13 14 15 16 17 DI 1 TX- or AUX- TX+ or AUX+ RX-/TX- RX+/TX+ SHIELD DI 2 UDC 3000 EXTERNAL WIRING L1/H L2/N 22 23 24 25 26 27 IN 1 IN 2 0 Instrument Power 22840 NOTE: The product manual should be consulted for specific details and precautions regarding wiri ...

  • Honeywell DC300K-E - page 12

    51-52-03-07 Page 12 Ordering Information For the complete ordering information, request Model Selection Guide: 51-51-16-32 for UDC3000 Universal Digital Controller or . . Honeywell offers a full Iine of Sensors, Transmitters, and Final Control Devices for use with the UDC3000 Universal Digital Controller. These devices include: Thermocouples, RTDs ...

Manufacturer Honeywell Category Universal Remote

Documents that we receive from a manufacturer of a Honeywell DC300K-E can be divided into several groups. They are, among others:
- Honeywell technical drawings
- DC300K-E manuals
- Honeywell product data sheets
- information booklets
- or energy labels Honeywell DC300K-E
All of them are important, but the most important information from the point of view of use of the device are in the user manual Honeywell DC300K-E.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Honeywell DC300K-E, service manual, brief instructions and user manuals Honeywell DC300K-E. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Honeywell DC300K-E.

Similar manuals

A complete manual for the device Honeywell DC300K-E, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Honeywell DC300K-E by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Honeywell DC300K-E.

A complete Honeywell manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Honeywell DC300K-E - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Honeywell DC300K-E, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Honeywell DC300K-E, that we can find in the current document
3. Tips how to use the basic functions of the device Honeywell DC300K-E - which should help us in our first steps of using Honeywell DC300K-E
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Honeywell DC300K-E
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Honeywell DC300K-E in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Honeywell DC300K-E?

Use the form below

If you did not solve your problem by using a manual Honeywell DC300K-E, ask a question using the form below. If a user had a similar problem with Honeywell DC300K-E it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)