Manual Zephyr EBO-E42ASX

22 pages 0.52 mb
Download

Go to site of 22

Summary
  • Zephyr EBO-E42ASX - page 1

    JAN06.0101 ...

  • Zephyr EBO-E42ASX - page 2

    2 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING . INST AL LA TION MUST COMPL Y WITH ALL LOCAL CODES. IMP ORT ANT : Save these Instructions for the Local Electrical Inspector s use. INS T ALLER: Please leave these Instructions with this unit for the owner . OWNER: Please ret ain these instructions for future reference. Safety W arning: T urn ...

  • Zephyr EBO-E42ASX - page 3

    3 www .zephyronline.com T able of Content s Important safet y Notice ..................................................................... 4 Electrical & Installa tion requir ements ............................................. 5 Electrical requirements .............................................................. 5 Before installing the hood ...

  • Zephyr EBO-E42ASX - page 4

    4 Import ant safety Notice CAUTION: FOR GENERAL VENTILA TING USE ONL Y . DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MA TERIALS OR VA P O R S . W ARNING T O REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, O R INJURY T O PERSONS, OBSER VE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer . If you have questions, contact the m ...

  • Zephyr EBO-E42ASX - page 5

    5 www .zephyronline.com Electrical & Inst allation requirement s ELECTRICAL REQUIREMENTS Important: Observe all governing codes and ordinances. It is the customers responsibility:  T o co nt act a qualified electrical inst all er .  T o assure that the electrical installation is adequate and in conformance with National Electrical Code ...

  • Zephyr EBO-E42ASX - page 6

    6 List of Materials PARTS SUPPLIED:  Blower unit housing  Hood canopy  Met al filter x 1  Halogen light bulb x 2  Duct covers  Remote Control  Hardware Packet: Allen spanner x 1 Lower support bracket Te m p l a t e Use, Care and Inst allation guide 2,9x6,5 screws x 4 (to fix duct cover) 6x20 screws x2 + bushings (to fix vapour ...

  • Zephyr EBO-E42ASX - page 7

    7 www .zephyronline.com Dimensions and clearances 19" 1 1/16 5/8" 2"min 7" 1/2* Side Cabinet Side Cabinet 35" 7/16 min. cabinets opening wid ths 24" to 32" bottom of canopy to cooking surface ceiling CenterLine 14" 6/8 26" 12" 12" Ducting and conduit area passage(Duct bends are not considered) ...

  • Zephyr EBO-E42ASX - page 8

    8 Inst allation Instructions Closely follow the instructions set out in this manual. All responsibility , for any eventu al inc onve nien ces, damage s or fires caused by not comp lyin g with the instru ctio ns in this manual, is declined. VENTING METHODS The hood is equipped with a transition B for discharge of fumes to the outside ( Ducting versi ...

  • Zephyr EBO-E42ASX - page 9

    9 www .zephyronline.com Inst allation - Ductwork Calculation Sheet 3 1/4  x 10 Rect., straight 6  Round,, straight 7", 8 Round,, straight 3 1/4  x 10 Rect.90° elbow 3 1/4  x 10 Rect.45° elbow 3 1/4  x 10 Rect.90° flat elbow 3 1/4  x 10 Rect. wall cap with damper 3 1/4  x 10 Rect.to 6  round trans ...

  • Zephyr EBO-E42ASX - page 10

    10 Inst allation 1. If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide easier ac ce ss to re ar wa ll . O th er wi se pu t a th ic k, pr ot ec ti ve covering over countertop, cooktop or range to protect from damage or dirt. Select a flat surface for assembling the unit. Cover that surface with a protecti ...

  • Zephyr EBO-E42ASX - page 11

    11 www .zephyronline.com 15. Install the vapour screen with 2 screws and bushes using the allen sp anner included. Glass Bush + Screw 16. Hang hood with the 2 mounting hooks. W ARNING Excessive Weight Hazard - Use two o r more people to move and install range hood. Failure to do so can result in back or other injury . 17. Level the appliance, using ...

  • Zephyr EBO-E42ASX - page 12

    12 19. Connect ducting to transition. Seal with duct tape. Do not use duct smaller than the transition. For Ductless - recirculating - installations only: provide and install a duct to connect hood transition to deflector (the deflector is available as an extra kit). 20. Electrical connection W ARNING Electrical Shock Hazard W arning: T urn off pow ...

  • Zephyr EBO-E42ASX - page 13

    13 www .zephyronline.com 24. Install duct cover with 4 screws. Note: Upper Duct Cover may be placed upside down to hide (or unhide) ventless slots. Lower duct cover Duct cover support bracket Duct cover support bracket Upper duct cover TOP VIEW 25. Check all light bulbs to make sure they are secure in their sockets. T urn power on in service panel. ...

  • Zephyr EBO-E42ASX - page 14

    14 Description of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp (position and nr . of lamp s m ay v ary ) 5 Hood canopy 6 Duct cover 7 Air outlet (used for Ductless version only) 1 6 7 5 4 4 2 3 ...

  • Zephyr EBO-E42ASX - page 15

    15 www .zephyronline.com Description of the hood - Control Ball CONTROLS Use the high suction speed in cases of concentrated kitchen v apours. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes appr oxima tely after terminating cooking. Des ...

  • Zephyr EBO-E42ASX - page 16

    16 Description of the hood - Remote Control USING THE REMOTE CONTROL This device complies with p art 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The ...

  • Zephyr EBO-E42ASX - page 17

    17 www .zephyronline.com Maintenance Prior to any maintenance operation ensure that the cooker hood is disconnected from the power supply . CLEANING The cooker hood should be cleaned regularly internally and externally . For cleaning use a cloth moistened with a neutral liquid detergents. Avoid abrasive detergents. Warning: Failure to carry out the ...

  • Zephyr EBO-E42ASX - page 18

    18 T rouble Shooting Af ter inst allation, the unit doesnt work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Met al filter is vibrating. 1. The power source is not turned ON. 2. The power line and the cable locking connector is not connecting p ...

  • Zephyr EBO-E42ASX - page 19

    19 www .zephyronline.com W arranty T O O BT AIN SERVICE UNDER W ARRANTY : or any Service Related Questions, please call: 1-888-880-8368 S taple your receipt here. Proof of the original purchase date is needed to obtain ser vic e under the warranty . T O O B T AIN SERVICE UNDER W ARRANTY : Y ou must present proof of original purchase date. Please ke ...

  • Zephyr EBO-E42ASX - page 20

    20 List of Part s and Accessories Part Description Part# Ductless Recirculating Kit charcoal replacement filter duct cover extension kit internal blower - 600 cfm in-line blower - 1 100 cfm EBI-600A EBN-1 100 A Z1C-00BO Z0F-C060 ZRC-00BO Part Description Pa r t# halogen bulb, 12V 20 W metal filter remote control (RF) remote control battery ..394 of ...

  • Zephyr EBO-E42ASX - page 21

    21 www .zephyronline.com ...

  • Zephyr EBO-E42ASX - page 22

    22 ...

Manufacturer Zephyr Category Cooktop

Documents that we receive from a manufacturer of a Zephyr EBO-E42ASX can be divided into several groups. They are, among others:
- Zephyr technical drawings
- EBO-E42ASX manuals
- Zephyr product data sheets
- information booklets
- or energy labels Zephyr EBO-E42ASX
All of them are important, but the most important information from the point of view of use of the device are in the user manual Zephyr EBO-E42ASX.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Zephyr EBO-E42ASX, service manual, brief instructions and user manuals Zephyr EBO-E42ASX. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Zephyr EBO-E42ASX.

Similar manuals

A complete manual for the device Zephyr EBO-E42ASX, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Zephyr EBO-E42ASX by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Zephyr EBO-E42ASX.

A complete Zephyr manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Zephyr EBO-E42ASX - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Zephyr EBO-E42ASX, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Zephyr EBO-E42ASX, that we can find in the current document
3. Tips how to use the basic functions of the device Zephyr EBO-E42ASX - which should help us in our first steps of using Zephyr EBO-E42ASX
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Zephyr EBO-E42ASX
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Zephyr EBO-E42ASX in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Zephyr EBO-E42ASX?

Use the form below

If you did not solve your problem by using a manual Zephyr EBO-E42ASX, ask a question using the form below. If a user had a similar problem with Zephyr EBO-E42ASX it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)