Manual Oregon Scientific PS-L06

30 pages 0.56 mb
Download

Go to site of 30

Summary
  • Oregon Scientific PS-L06 - page 1

    EN Full Weather St ation wit h Radio Cont rolled Clock , Projection and AM /FM Radio (Model #: PS- L06 / PS-L06U ) User Manual PS-L06_GB-final.p65 8/8/03, 12:02 PM 1 ...

  • Oregon Scientific PS-L06 - page 2

    EN PS-L06_GB-final.p65 8/8/03, 12:02 PM 2 ...

  • Oregon Scientific PS-L06 - page 3

    EN T ABLE OF CONTENTS About this guide ........................................................ 2 Product overview ....................................................... 3 Getting started .......................................................... 8 Batteries .............................................................. 8 AC power adapter ........ ...

  • Oregon Scientific PS-L06 - page 4

    EN ABOUT THIS GUIDE Congratulations on your selection of the Philippe Starck with Oregon Scientific Full W eather Station with Radio-Controlled Projection Clock and AM/FM Radio (PS-L06 / PS-L06U). This powerful device bundles time keeping, alarm, indoor and wireless outdoor tempera- ture and humidity monitoring, weather forecasting, projection, and ...

  • Oregon Scientific PS-L06 - page 5

    EN PRODUCT OVERVIEW TOP VIEW DESCRIPTIONS 1. Snooze / Light button ( → 12, 19) 2. Light sensor ( → 19) 3. Projection lens ( → 20) 1 2 3 3 PS-L06_GB-final.p65 8/8/03, 12:02 PM 5 ...

  • Oregon Scientific PS-L06 - page 6

    EN LCD DISPLA Y DESCRIPTIONS 1. Low batteries icon ( → 8) 2. Clock ( → 10) 3. Barometer ( → 13) 4. Weather forecast ( → 15) 5. Moon phase ( → 13) 6. Calendar ( → 12) 7. T emperature and humidity ( → 15) 8. Alarm ( → 11) 9. Radio ( → 18) 1 2 3 4 69 8 7 5 4 PS-L06_GB-final.p65 8/8/03, 12:02 PM 6 ...

  • Oregon Scientific PS-L06 - page 7

    EN BACK VIEW BUTTON DESCRIPTIONS 1. Focus – focus projector ( → 20) 2. Select – switch modes / change settings 3. Rotation – rotate projector ( → 20) 4. Up – increase setting / activate auto-synch ( → 11) 5 . Down – decrease setting / deactivate auto-synch ( → 11) 6. Alarm –activate / deactivate alarm ( → 12) 7. Channel – sw ...

  • Oregon Scientific PS-L06 - page 8

    EN BOTTOM VIEW DESCRIPTIONS 1. Battery compartment ( → 8) 2. Light sensitivity knob ( → 20) 3. Reset button ( → 8, 21) 4. Antenna ( → 18) 5. Headphone jack ( → 19) 6. DC power input jack ( → 8) 7. Backlight switch ( → 19) NO TE AC power adapter not shown. 6 3 2 14 5 6 7 PS-L06_GB-final.p65 8/8/03, 12:02 PM 8 ...

  • Oregon Scientific PS-L06 - page 9

    EN REMOTE UNIT DESCRIPTIONS 1. T emperature / T rend display 2. Low battery icon 3. Humidity / T rend / Comfort Level display 4. ° C / ° F switches 5. Channel switches 6. Reset button 7. Battery compartment 8. W all-mount hole 9. Battery compartment lid 7 7 9 2 3 6 4 1 5 8 PS-L06_GB-final.p65 8/8/03, 12:02 PM 9 ...

  • Oregon Scientific PS-L06 - page 10

    EN GETTING ST ARTED BA TTERIES Batteries for the remote and main units are supplied with this product. Replace them whenever the low battery signal ( ) displays. Remove the battery compartment lid on the bottom of the main unit, and insert the batteries. Use a small Phillips screwdriver to remove the remote unit compartment lid. Be sure to match th ...

  • Oregon Scientific PS-L06 - page 11

    EN SWITCH BETWEEN MODES Press SELECT . The select mode will flash. The display will stop flashing if no key is pressed within 5 seconds. CHANGE SETTINGS Press and hold SELECT for 2 seconds. Then, press UP or DOWN to change each setting. Press SELECT to switch options. REMOTE UNIT SET UP Up to 3 remote units can be used with this product to monitor ...

  • Oregon Scientific PS-L06 - page 12

    EN • Position the unit so that it faces the main (indoor) unit. Minimize obstructions such as doors, walls, and furniture. Y ou may need to experiment with various locations to get the best reception. CLOCK This product can automatically synchronize the date and time with official time-keeping organizations in Frankfurt, Germany (PS-L06) or Rugby ...

  • Oregon Scientific PS-L06 - page 13

    EN TO DISABLE OR ENABLE AUTO- SYNCHRONIZA TION In Clock mode, Press DOWN for 2 seconds to disable the auto-synchronization. The unit will not respond to radio signals until you reactivate the synchronization. T o enable auto-r eception, pr ess UP for 2 seconds. SET OR CHANGE THE CLOCK 1. Press SELECT to switch to the Clock Mode. The time will flash ...

  • Oregon Scientific PS-L06 - page 14

    EN SELECT to confirm. If you choose , also select the melody (1 – 7) and volume level (Lo or Hi). If you choose , use the radio control buttons to select the AM/FM band, radio station and volume level ( → 18). 4. Press SELECT again when you are finished. SNOOZE Press the SNOOZE/LIGHT button the top of the unit to temporarily disable the alarm f ...

  • Oregon Scientific PS-L06 - page 15

    EN 3. Select the year , month, date, and language. Press UP or DOWN to change the setting. Press SELECT to confirm. NO TE The language options are (E) English, (F) French, (D) German, (I) Italian, and (S) Spanish. MOON PHASE Press SELECT until the Calendar Area flashes. Then, press UP or DOWN to change the date and view the corresponding moon phase ...

  • Oregon Scientific PS-L06 - page 16

    EN BAROMETRIC TREND The barometric trend arrow for the last 30 minutes is always displayed. VIEW THE LAST 24 HOURS Press SELECT 2 times until the Barometer Area flashes. Then, press UP or DOWN to view the last 24 hours history . SET UNIT AND AL TITUDE Y ou can set the unit of measurement (mb/hPa or inHg) and altitude. Setting the altitude allows th ...

  • Oregon Scientific PS-L06 - page 17

    EN WEA THER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30 to 50 km (19 - 31 mile) radius with 70 to 75 percent accuracy . The weather forecast is always displayed. TEMPERA TURE AND HUMIDITY With the press of a button, you can check the current indoor or outdoor temperature, humidity percentage, comfort level, trend, ...

  • Oregon Scientific PS-L06 - page 18

    EN clears the previous measurements from the memory . SELECT REMOTE UNIT CHANNEL While in the T emperatur e / Humidity Mode, press CHANNEL to switch between CH 1, 2, or 3, or press and hold CHANNEL for 2 seconds to enter Auto scan mode. If only 1 remote unit is in use, you will not be able to change channels or Auto scan. If you select “Auto”, ...

  • Oregon Scientific PS-L06 - page 19

    EN COMFORT ZONE The indoor and outdoor comfort zones are shown for the following conditions. TRENDS The trend arrow for the last 30 minutes always displays. Indoor and outdoor temperature and humidity trends are shown separately . 17 Zone T emperature Relative Humidity We t Dry Comfort Any 20 – 25 ° C (68 - 77 ° F) >70% <40% 40 – 70% An ...

  • Oregon Scientific PS-L06 - page 20

    EN SET UNIT While in T emperature / Humidity Mode, press SELECT for 2 seconds. Press UP or DOWN to switch between ° C and ° F . Press SELECT to confir m. RADIO Y ou can listen to PLL digital radio broadcasts with this product. ANTENNA The antenna wire is located in the battery compartment. Position it for the best reception. TURN THE RADIO ON OR ...

  • Oregon Scientific PS-L06 - page 21

    EN STORE ST A TION TO MEMORY Press ST A TION for 2 seconds. The assigned number (1 – 8) will show in the Radio Area. SLEEP TIMER Press SLEEP . T o change the timer length (0 – 120 minutes in increments of 10) press UP or DOWN . The radio automatically turns off when the timer r eaches 0. T o manually tur n off the radio, press RADIO . HEADPHONE ...

  • Oregon Scientific PS-L06 - page 22

    EN 3. The Light Sensitivity knob is located in the battery compartment. Rotate to adjust. 4. When activated, the continuous backlight will be half as bright as usual. T o achieve full brightness, press SNOOZE/LIGHT . PROJECTOR This product has a built-in projector for viewing time and alarm status at night. NO TE The maximum projection range is 2 m ...

  • Oregon Scientific PS-L06 - page 23

    EN CONTINUOUS PROJECTION The AC power adapter must be plugged in to use this feature ( → 8). Press and hold SNOOZE/LIGHT for 2 seconds. when the projection is on. When activated, the time and alarm status will project continuously . Press and hold SNOOZE/LIGHT for 2 seconds again to deactivate. RESET SYSTEM The RESET buttons are located in the ba ...

  • Oregon Scientific PS-L06 - page 24

    EN W ARNINGS This product is designed to give you years of service if handled properly . Observe the following guidelines: • Never immerse the unit in water . This can cause electrical shock and damage the unit. • Do not subject the main unit to extreme force, shock, or fluctuations in temperature or humidity . • Do not tamper with the intern ...

  • Oregon Scientific PS-L06 - page 25

    EN 23 Problem Symptom Remedy Radio Remote unit Reception is poor / static Cannot locate remote unit Select radio format ( → 18) Check batteries ( → 8) Place clock near a window ( → 10) Check location ( → 9) Cannot change channel Check sensors. Only one sensor is working ( → 16 ) Adjust the antenna ( → 18) Problem Symptom Remedy Clock Ca ...

  • Oregon Scientific PS-L06 - page 26

    EN SPECIFICA TIONS Main unit dimensions L x W x H 181 x 45 x 185.3 mm (7.1 x 1.77 x 7.3 inches) W eight 994 grams with battery Remote unit dimensions L x W x H 75 x 35 x 78.3mm (3 x 1.4 x 3.1 inches) W eight 136 grams with battery T emperature Unit ° C or ° F Range Main unit: -5 ˚C to 50 ˚C (23 ˚F to 122 ˚F) 24 Problem Symptom Remedy Cannot c ...

  • Oregon Scientific PS-L06 - page 27

    EN Remote Unit: -20 ˚C to 60 ˚C (-4 ˚F to 140 ˚F) Resolution 0.1 ° C (0.2 ° F) Comfort 20 ° C to 25 ° C (68 ° F to 77 ° F) (see also, Relative humidity) Memory Minimum / maximum T rend +/- 0.5 ˚C (+/- 0.9 ˚F) change Relative humidity Range Main & Remote Unit: 25% to 95% Resolution 1% Comfort 40% to 70% (see also, T emperature) Memor ...

  • Oregon Scientific PS-L06 - page 28

    EN Channel No. 1, 2, or 3 Unit ° C or ° F Radio-controlled clock Synchronization Auto or disabled Clock display HH:MM:SS Hour format 12hr AM/PM (MSF format) 24hr (DCF format) Calendar DD/MMM; weekday selection in 5 languages (E, D, F , I, S) Moon phase High, medium, and low tide Alarm 7 melody or radio; 2 minute crescendo (melody only) Snooze 8 m ...

  • Oregon Scientific PS-L06 - page 29

    EN Power Main unit 4 x UM-3 (AA) 1.5V alkaline batteries (back-up) AC/DC 7.5V power adapter (for normal operation and continuous backlight and projector) Remote unit 2 x UM-4 (AAA) 1.5V alkaline batteries ADDITIONAL RESOURCES V isit our website (www .oregonscientific.com) to learn more about your new product and other Oregon Scientific products suc ...

  • Oregon Scientific PS-L06 - page 30

    EN EC-DECLARA TION OF CONFORMITY This product contains the approved transmitter module TX 07 and complies with the essential requirements of Article 3 of the R&TTE 1999/5/EC Directives, if used for its intended use and that the following standard(s) has/have been applied: Radio frequency spectrum (Article 3.2 of the R&TTE Directive) applied ...

Manufacturer Oregon Scientific Category Stereo System

Documents that we receive from a manufacturer of a Oregon Scientific PS-L06 can be divided into several groups. They are, among others:
- Oregon Scientific technical drawings
- PS-L06 manuals
- Oregon Scientific product data sheets
- information booklets
- or energy labels Oregon Scientific PS-L06
All of them are important, but the most important information from the point of view of use of the device are in the user manual Oregon Scientific PS-L06.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Oregon Scientific PS-L06, service manual, brief instructions and user manuals Oregon Scientific PS-L06. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Oregon Scientific PS-L06.

A complete manual for the device Oregon Scientific PS-L06, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Oregon Scientific PS-L06 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Oregon Scientific PS-L06.

A complete Oregon Scientific manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Oregon Scientific PS-L06 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Oregon Scientific PS-L06, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Oregon Scientific PS-L06, that we can find in the current document
3. Tips how to use the basic functions of the device Oregon Scientific PS-L06 - which should help us in our first steps of using Oregon Scientific PS-L06
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Oregon Scientific PS-L06
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Oregon Scientific PS-L06 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Oregon Scientific PS-L06?

Use the form below

If you did not solve your problem by using a manual Oregon Scientific PS-L06, ask a question using the form below. If a user had a similar problem with Oregon Scientific PS-L06 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)