Manual Hearth and Home Technologies 6000G-IPILP

74 pages 3.6 mb
Download

Go to site of 74

Summary
  • Hearth and Home Technologies 6000G-IPILP - page 1

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 1 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch any electrical switch. DO NOT use any phone in your building. - Immediatel ...

  • Hearth and Home Technologies 6000G-IPILP - page 2

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealership purchased from: _____________ ...

  • Hearth and Home Technologies 6000G-IPILP - page 3

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous situation w ...

  • Hearth and Home Technologies 6000G-IPILP - page 4

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 4  = Contains updated information. 13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 52 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 C. Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Hearth and Home Technologies 6000G-IPILP - page 5

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 5 B. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and instal ...

  • Hearth and Home Technologies 6000G-IPILP - page 6

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 6 B. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials. Rust ...

  • Hearth and Home Technologies 6000G-IPILP - page 7

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 7 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commission (CPSC). The tempered glass has been teste ...

  • Hearth and Home Technologies 6000G-IPILP - page 8

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where th ...

  • Hearth and Home Technologies 6000G-IPILP - page 9

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 9 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . DECORA TIVE DOORS (NOT SHOWN) SEC ...

  • Hearth and Home Technologies 6000G-IPILP - page 10

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects. Figure 2.2 Clea ...

  • Hearth and Home Technologies 6000G-IPILP - page 11

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 1 1 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when using the transformer . 1. Turn off all electric power to the appliance. 2. This appliance is equipp ...

  • Hearth and Home Technologies 6000G-IPILP - page 12

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 12 J. Lighting Instructions (Standing Pilot) 1. Turn of f all electric power to the appliance if ser- vice is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”. DO NOT force. 5. Cl ...

  • Hearth and Home Technologies 6000G-IPILP - page 13

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 13 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly . See Section 14.G. • Clean fi xed glass assembly . See Section 3. • Replace ...

  • Hearth and Home Technologies 6000G-IPILP - page 14

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 14 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming glass • Avoid abrasive cl ...

  • Hearth and Home Technologies 6000G-IPILP - page 15

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 15 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc. • V erify termination cap clearance to subsequent construc- ...

  • Hearth and Home Technologies 6000G-IPILP - page 16

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 16 (Either cobrahead or SIT) PRODUCT SPECIFIC Figure 3.1 IPI Pilot Flame Patterns Figure 3.2 Standing Pilot Flame Patterns ...

  • Hearth and Home Technologies 6000G-IPILP - page 17

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 17 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.1 T ypical System CEILING FIRESTOP ON FLOOR OF ...

  • Hearth and Home Technologies 6000G-IPILP - page 18

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 18 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. Installation MUST ...

  • Hearth and Home Technologies 6000G-IPILP - page 19

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 19 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service a ...

  • Hearth and Home Technologies 6000G-IPILP - page 20

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 20 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: T reatment of ceiling fi restops and wall shield fi restops and const ...

  • Hearth and Home Technologies 6000G-IPILP - page 21

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 21 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, etc). Combu ...

  • Hearth and Home Technologies 6000G-IPILP - page 22

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 22 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 ................................................ ...

  • Hearth and Home Technologies 6000G-IPILP - page 23

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 23 O N P R Q V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 6.3 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches................. clearances to window or d ...

  • Hearth and Home Technologies 6000G-IPILP - page 24

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 24 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP or SLP venting systems. Refer to Sec- tion 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers. The pipe is tested to be run ...

  • Hearth and Home Technologies 6000G-IPILP - page 25

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 25 INST ALLED HORIZONT ALL Y H 1 H 2 V 1 H 1 V 1 Figure 7.3 Figure 7.4 T op V ent - Horizontal T ermination T op V ent - Horizontal T ermination One Elbow T wo Elbows Note: For corner installations: A 6 inch (152 mm) section of straight pipe may need to be attached to the appliance ...

  • Hearth and Home Technologies 6000G-IPILP - page 26

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 26 Figure 7.5 T op V ent - Horizontal T ermination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Min. H 1 Max. V 2 Min. H 2 Max. Elbow only 2 ft. 610 mm 0 in. 0 mm 1 ft. 305 mm 6 in. 152 mm 3 ft 914 mm 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 6 ft. 1.8 m 1 ft. 305 mm 6 ft. 1.8 m 2 ft ...

  • Hearth and Home Technologies 6000G-IPILP - page 27

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 27 EXHAUST SHIELD FLUE RESTRICTOR T op V ent - V ertical T ermination No Elbow Figure 7.6 Note: If installing a vertical vent/ termination off the top of the ap- pliance, the fl ue restrictor should be used. V 1 V 1 = 40 ft. Max. (12.4 m) V 1 = 3 ft. Min. (914 mm) Flue Restrictor I ...

  • Hearth and Home Technologies 6000G-IPILP - page 28

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 28 H 1 V 1 V 2 T op V ent - V ertical T ermination (continued) Figure 7.1 1 T wo Elbows Figure 7.10 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.10). 5. Reinstall the Exhaust Shield. 3. Match the amount of vertical you have ...

  • Hearth and Home Technologies 6000G-IPILP - page 29

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 29 Figure 7.12 T op V ent - V ertical T ermination - (continued) Three Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 2 V 1 H 1 + H 2 V 2 V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft. 305 mm * * * 1 ft. 305 mm 6 in. 152 mm 2 ft. 610 mm * * * 2 ft. 610 mm 1 ft. 305 mm 2 ft. 61 ...

  • Hearth and Home Technologies 6000G-IPILP - page 30

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 30 Rear V ent - Horizontal T ermination Figure 7.13 Figure 7.14 No Elbow One 45º Elbow H 1 H 1 H 1 = 16 in. (406 mm) Maximum Do not use a 45º elbow in corner installations. Use two 90º elbows instead. H 1 = 9 in. (229 mm) Maximum ...

  • Hearth and Home Technologies 6000G-IPILP - page 31

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 31 INSTALLED HORIZONTALLY H 3 H 1 H 2 V 1 Rear V ent - Horizontal T ermination - (continued) T wo Elbows Figure 7.15 Figure 7.16 Three Elbows H 1 H 2 V 1 H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 1 ft. 305 mm Back to Back 90º Elbows 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 6 in. ...

  • Hearth and Home Technologies 6000G-IPILP - page 32

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 32 Rear V ent - V ertical T ermination One Elbow Figure 7.17 T wo Elbows Figure 7.18 H 1 V 1 INST ALL ED HORIZONT ALL Y H 1 H 2 V 2 V 1 Minimum H 1 Maximum 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 7 ft. 2.1 m 4 ft. 1.2 m 8 ft 2.4 m 5 ...

  • Hearth and Home Technologies 6000G-IPILP - page 33

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 33 Rear V ent - V ertical T ermination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 INST ALLED HORIZONT ALL Y H 3 H 1 H 2 V 1 V 2 V 1 H 2 H 1 H 1 H 2 H 3 V 1 Minimum H 1 + H 2 + H 3 Maximum *** 8 ft. 2.4 m 6 ft. 1.8 m *** 9 ft. 2.7 m 7 ft. 2.1 m *** 10 ft. 3.1 m 8 ...

  • Hearth and Home Technologies 6000G-IPILP - page 34

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 34 A* B* 10 in. 12 in. C D 10 in. 10 in. A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops • Between wall shield fi restops • Around vent system Failure ...

  • Hearth and Home Technologies 6000G-IPILP - page 35

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 35 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.3). • SLP pipe only - Frame opening 9 in. x 9 in ...

  • Hearth and Home Technologies 6000G-IPILP - page 36

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 36 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an attic shield constructed of 2 ...

  • Hearth and Home Technologies 6000G-IPILP - page 37

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 37 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. A. T op V ent 9 9 Appliance Preparation ...

  • Hearth and Home Technologies 6000G-IPILP - page 38

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 38 B. Rear V ent NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. Figure 9.6 Fold the tabs toward the center of the seal cap (90º) and remove the insulation gasket. Figure 9.7 Cut the metal retaining band and fold the sides out. Figure ...

  • Hearth and Home Technologies 6000G-IPILP - page 39

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 39 D. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation. Make sure ins ...

  • Hearth and Home Technologies 6000G-IPILP - page 40

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 40 1 0 10 Inst alli ng V ent Pi pe (D VP and SLP P ipe ) A. Assemble V ent Sections (DVP Pipe Only) Attach V ent to the Firebox Assembly Note: The end of t he pipe secti ons with the lanc ed tabs wi ll face toward the applianc e. Attach the fi rst pipe section to the starting colla ...

  • Hearth and Home Technologies 6000G-IPILP - page 41

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 41 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance: • Attach a DVP-2SL or DVP-SLP24 adapter to the starting collar of the appliance. • Lock the vent components into place by sliding the pipe section onto t ...

  • Hearth and Home Technologies 6000G-IPILP - page 42

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 42 120º Figure 10.8 Securing V ertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble V ent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown in Figure 10.1 1. • Pull carefully to separa ...

  • Hearth and Home Technologies 6000G-IPILP - page 43

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 43 F . Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the fi restop. • Seal the gap between the vent pipe and fi restop using high ...

  • Hearth and Home Technologies 6000G-IPILP - page 44

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 44 G. Install Metal Roof Flashing Note : Skip this section if using the RF4-8. • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the ...

  • Hearth and Home Technologies 6000G-IPILP - page 45

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 45 I. Install RF4-8 The RF4-8 may be used in place of the roof fl ashing and storm collar (Sections 10.G. and 10.H.) Pipe must be supported within 12 inches of the roofline using plumbers strapping or an SLP-FS when using the RF4-8 Flashing. Refer to Section 10.D. Secure Vent Secti ...

  • Hearth and Home Technologies 6000G-IPILP - page 46

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 46 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.23 Figure 10.23 TERMINA TION CAP J. Install V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar of the cap o ...

  • Hearth and Home Technologies 6000G-IPILP - page 47

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 47 Figure 10.25 Venting through the wall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEA THING VENT DEPTH FROM BACK OF APPLIANCE T O OUTSIDE SURF ACE OF EXTERIOR WA LL (SEE CHART BELOW) SLIP SECTION CAN BE EXTENDE ...

  • Hearth and Home Technologies 6000G-IPILP - page 48

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 48 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts. B. Gas Pressure • Optimum appliance performance requires ...

  • Hearth and Home Technologies 6000G-IPILP - page 49

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 49 Figure 12.1 Ignitor Button C. Standing Pilot Ignition System Wiring • The standing pilot ignition system wiring does not require a 1 10 V AC supply to operate. See Figure 12.3 • A 1 10 V AC junction box MUST be installed for use with a fan or remote control. See Figure 12.4 f ...

  • Hearth and Home Technologies 6000G-IPILP - page 50

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 50 E. Electrical Service and Repair W ARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing. Figure 12.2 Intelli fi re Pilot Ignition (IPI) Wiring D ...

  • Hearth and Home Technologies 6000G-IPILP - page 51

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 51 G. W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.5): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from the switch box to the applian ...

  • Hearth and Home Technologies 6000G-IPILP - page 52

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 52 1 3 13 Fi nishing A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materi- als (i.e., steel studs, concrete board, etc.) Failure t ...

  • Hearth and Home Technologies 6000G-IPILP - page 53

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 53 C. Doors Only doors certi fi ed for use with this appliance model may be used. Contact your dealer for a list of doors that may be used. Once you have determined what kind of door and fi nishing material is going to be used on the fi replace, you may use the table below which ...

  • Hearth and Home Technologies 6000G-IPILP - page 54

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 54 A. Remove Fixed Glass Assembly See Section 14.G. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity ...

  • Hearth and Home Technologies 6000G-IPILP - page 55

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 55 F . Install the Log Assembly STEP 2. Place the metal grate on top of the burner . Position the legs of the grate into the forward set of indentations in the burner top. Make sure the grate is all the way forward. See Figure 14.3. Log Assembly: LOGS-6000G STEP 1. CAUTION: Logs are ...

  • Hearth and Home Technologies 6000G-IPILP - page 56

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 56 Figure 14.13 T op View Figure 14.7 T op View STEP 5. Log #3 (SRV2103-1 10): Place log #3 on top of the burner surface in front of the hump. The bottom of the log has a square groove cut through it. The groove sits over the second grate tine from the left. Slide it back against th ...

  • Hearth and Home Technologies 6000G-IPILP - page 57

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 57 I. Air Shutter Setting Air shutter settings should be adjusted by a quali fi ed ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 14.15. • Loosen the wi ...

  • Hearth and Home Technologies 6000G-IPILP - page 58

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 58 A. Standing Pilot Ignition System 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service technician i ...

  • Hearth and Home Technologies 6000G-IPILP - page 59

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 59 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. (Continued) C. V alve. T urn the valve knob to the ON position. Place the ON/ OFF switch in the ON position. T ake a reading with a millivolt meter at the thermopile terminals. The millivolt meter should rea ...

  • Hearth and Home Technologies 6000G-IPILP - page 60

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 60 B. Intelli fi re Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. A. Incorrect wiring. V erify “S” wire (white) for sensor and “I” wire (orange) for ignitor are connected to correct terminals o ...

  • Hearth and Home Technologies 6000G-IPILP - page 61

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 61 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.) A. A ...

  • Hearth and Home Technologies 6000G-IPILP - page 62

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 62 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions A D B C H ELECTRICAL ACC ESS G F E GAS LINE ACC ESS N O L M I ...

  • Hearth and Home Technologies 6000G-IPILP - page 63

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 63 B. V ent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in. (337 mm) 1/2 in. TYP DVP90ST (90° Elbow) 10 in. (254 mm) 10 in. (254 mm) 1 in. (25 mm ...

  • Hearth and Home Technologies 6000G-IPILP - page 64

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 64 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a ...

  • Hearth and Home Technologies 6000G-IPILP - page 65

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 65 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in. (349 mm) 5 in. (127 mm) 13-3/4 in. (349 mm) Cap Shield DRC-RADIU ...

  • Hearth and Home Technologies 6000G-IPILP - page 66

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 66 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) PVK-80 (For use with IPI and DSI appliances only.) ...

  • Hearth and Home Technologies 6000G-IPILP - page 67

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 67 B. V ent Components Diagrams (continued) DVP-HRC-SS DVP-HRC-ZC-SS HORIZONT AL TERMINA TION CAP 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. 213 mm Figur ...

  • Hearth and Home Technologies 6000G-IPILP - page 68

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 68 B. V ent Components Diagrams (continued) Figure 16.7 SLP Series V ent Components 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in. 251 mm 6-1/2 in. 165 mm 9-1/4 in. 235 mm SLP45 45° Elbow SLP-90ST 90° Elbow Effective Hei ...

  • Hearth and Home Technologies 6000G-IPILP - page 69

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 69 B. V ent Components Diagrams (continued) Figure 16.8 SLP Series V ent Components SLP-SNKD Snorkel T ermination Cap SLP-TVHW V ertical T ermination Cap SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLP-WT -BK W all Thimble-Black SLP-TRAP2 Horizon ...

  • Hearth and Home Technologies 6000G-IPILP - page 70

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 70 C. Service Parts Part number list on following page. Service Parts Diagram 3 2 5 4 1 Log Set Assembly 10 7 9 6 11 8 Beginning Manufacturing Date: May 2006 Ending Manufacturing Date: ______ 6000G, 6000G-IPI ...

  • Hearth and Home Technologies 6000G-IPILP - page 71

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 71 Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRIPTIO ...

  • Hearth and Home Technologies 6000G-IPILP - page 72

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 72 Service Parts V alve Assembly Diagram/ Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . S ...

  • Hearth and Home Technologies 6000G-IPILP - page 73

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 73 Standing Pilot Ignition V alve Assembly Service Parts V alve Assembly Diagram/ Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may ...

  • Hearth and Home Technologies 6000G-IPILP - page 74

    Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev . O • 12/08 74 D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer , please visit www .heatnglo.com. - NOTES - ________________________________________________________________________________ ___ ...

Manufacturer Hearth and Home Technologies Category Indoor Fireplace

Documents that we receive from a manufacturer of a Hearth and Home Technologies 6000G-IPILP can be divided into several groups. They are, among others:
- Hearth and Home Technologies technical drawings
- 6000G-IPILP manuals
- Hearth and Home Technologies product data sheets
- information booklets
- or energy labels Hearth and Home Technologies 6000G-IPILP
All of them are important, but the most important information from the point of view of use of the device are in the user manual Hearth and Home Technologies 6000G-IPILP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Hearth and Home Technologies 6000G-IPILP, service manual, brief instructions and user manuals Hearth and Home Technologies 6000G-IPILP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Hearth and Home Technologies 6000G-IPILP.

A complete manual for the device Hearth and Home Technologies 6000G-IPILP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Hearth and Home Technologies 6000G-IPILP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Hearth and Home Technologies 6000G-IPILP.

A complete Hearth and Home Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Hearth and Home Technologies 6000G-IPILP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Hearth and Home Technologies 6000G-IPILP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Hearth and Home Technologies 6000G-IPILP, that we can find in the current document
3. Tips how to use the basic functions of the device Hearth and Home Technologies 6000G-IPILP - which should help us in our first steps of using Hearth and Home Technologies 6000G-IPILP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Hearth and Home Technologies 6000G-IPILP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Hearth and Home Technologies 6000G-IPILP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Hearth and Home Technologies 6000G-IPILP?

Use the form below

If you did not solve your problem by using a manual Hearth and Home Technologies 6000G-IPILP, ask a question using the form below. If a user had a similar problem with Hearth and Home Technologies 6000G-IPILP it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)