    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 1 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc HygroClip DI Digital Interface v 1.0 Instruction Manual ...

  • Rotronic HygroClip DI digital interface - page 2

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 2 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc Contents: 1. Overview ............................................................................................. ...

  • Rotronic HygroClip DI digital interface - page 3

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 3 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc 1. Overview The HygroClip DI (Digital Interface) all ows connecting up to two HygroClip digital humidity- temperatu ...

  • Rotronic HygroClip DI digital interface - page 4

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 4 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc HygroClip DI-4 • RJ45 port (wired Ethernet LAN) • Two probe inputs (HygroClip prob es) • RS-485 port (4-pin c ...

  • Rotronic HygroClip DI digital interface - page 5

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 5 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc HygroClip S measurement in air max. 85 ° C (185 ° F) – wire mesh filter HygroClip SP05 measurement in air ducts ...

  • Rotronic HygroClip DI digital interface - page 6

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 6 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc The following probes have a 7-pin connector. An adapter cabl e such as the T7-03-B5 is requi red for connection to ...

  • Rotronic HygroClip DI digital interface - page 7

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 7 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc 6. Pin-out diagrams Input 1, 2 and 3 (HygroLog NT2, NT3 ) - solder side of matching male connector 3 1: not used 2: ...

  • Rotronic HygroClip DI digital interface - page 8

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 8 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc Operating System compatibility: ● Windows XP, NT4 with SP 6a or higher ● Windows 2000 with SP 2 or higher ● W ...

  • Rotronic HygroClip DI digital interface - page 9

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 9 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc The forms that are available within the Device Mana ger form are listed in a tree located on the left pane of the f ...

  • Rotronic HygroClip DI digital interface - page 10

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 10 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc Device Information ● Device name : this text will be displayed next to the instrument model info rmation. As far ...

  • Rotronic HygroClip DI digital interface - page 11

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 11 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc Language / Unit System ● Units : use the underlined links to the ri ght of t he form to globally change the unit ...

  • Rotronic HygroClip DI digital interface - page 12

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 12 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc Probe Inputs Clicking on the plus sign to the left of “Probe Input s” expands the tree and displ ays probe inp ...

  • Rotronic HygroClip DI digital interface - page 13

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 13 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc Dew point (Dp) or Frost point (Fp): depending on th e selection made here, HW4 will displ ay either the symbol Dp ...

  • Rotronic HygroClip DI digital interface - page 14

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 14 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc IMPORTANT: All devices within an RS-485 multi-drop should use the same ba ud rate. Communication within the RS-485 ...

  • Rotronic HygroClip DI digital interface - page 15

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 15 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc To protect the device, click on the underlined lin k. HW4 opens the following form where a password can be entered ...

  • Rotronic HygroClip DI digital interface - page 16

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 16 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc To unprotect the device and enabl e all functions, click on the underlined lin k. HW4 opens the password form: Ent ...

  • Rotronic HygroClip DI digital interface - page 17

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 17 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc 7.5 Probe adjustment Please consult the HW4 on-line in struction manual. 8. Baud rate comp atibility requirement s ...

  • Rotronic HygroClip DI digital interface - page 18

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 18 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc 9. Ethernet local area network ROTRONIC devices with an Ethern et (TCP/IP) interface presently use an intern al mo ...

  • Rotronic HygroClip DI digital interface - page 19

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 19 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc for RS-485 slaves” is being used, HW4 automatic ally cha nges from 00 to 01 the RS-485 address of any master tha ...

  • Rotronic HygroClip DI digital interface - page 20

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 20 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc 11. S pecifications Model HygroClip DI-3 HygroClip DI-4 HygroClip DI-4-WL PC Interface USB RJ45 Wireless Serial in ...

  • Rotronic HygroClip DI digital interface - page 21

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 21 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc 12. Accessories Order Code Description HW4-E HW4 Edition software (CD ROM), single user HW4-P HW4 Professional sof ...

  • Rotronic HygroClip DI digital interface - page 22

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 22 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc 14. Electrical Inst allation Guidelines Power supply wiring Heavy machinery and instrumentation should not sha re ...

  • Rotronic HygroClip DI digital interface - page 23

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 23 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc Lightning protection Cabling in areas with a risk of lightning requi re s a lightning protection. For cabling unde ...

  • Rotronic HygroClip DI digital interface - page 24

    IN-E-HyClip DI-V1_10 Rotronic AG Bassersdorf, Switzerland Document code Unit Instruction Manual Document Type HygroClip DI digital interface: instruction manual Document title Page 24 of 24 © 2007; Rotronic AG IN-E-HyClip DI-V1_10.doc The following points should also be ob served: • Close the parasitic circuit • Connect all devices to the pote ...

Manufacturer Rotronic Category Network Card

Documents that we receive from a manufacturer of a Rotronic HygroClip DI digital interface can be divided into several groups. They are, among others:
- Rotronic technical drawings
- HygroClip DI digital interface manuals
- Rotronic product data sheets
- information booklets
- or energy labels Rotronic HygroClip DI digital interface
All of them are important, but the most important information from the point of view of use of the device are in the user manual Rotronic HygroClip DI digital interface.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Rotronic HygroClip DI digital interface, service manual, brief instructions and user manuals Rotronic HygroClip DI digital interface. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Rotronic HygroClip DI digital interface.

A complete manual for the device Rotronic HygroClip DI digital interface, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Rotronic HygroClip DI digital interface by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Rotronic HygroClip DI digital interface.

A complete Rotronic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Rotronic HygroClip DI digital interface - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Rotronic HygroClip DI digital interface, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Rotronic HygroClip DI digital interface, that we can find in the current document
3. Tips how to use the basic functions of the device Rotronic HygroClip DI digital interface - which should help us in our first steps of using Rotronic HygroClip DI digital interface
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Rotronic HygroClip DI digital interface
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Rotronic HygroClip DI digital interface in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Rotronic HygroClip DI digital interface?

Use the form below

If you did not solve your problem by using a manual Rotronic HygroClip DI digital interface, ask a question using the form below. If a user had a similar problem with Rotronic HygroClip DI digital interface it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)