  • GE 960 Series - page 1

    With 960 Series Contr ol 5-Cycle Condition er 5-C ycle F A Filt er Water Cond itioning Control S yst em Installati on, Oper ation and M aintenance M anual Au totr o l Pe r f orma Pr oSoft ® ™ ...

  • GE 960 Series - page 2

    2 Table of C ontents Instal lati on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Location Select ion Wa t e r L ine C o nn ec ti o n Dr ain L ine C o nn ec ti on Reg ene ra nt Lin e Over flo w Li ne Co nnec ti on Plac ing Cond ition e r into Op era tion . . . . . . . . . . . . . . 5 Electri cal Conn ectio n 960 Pr o S ...

  • GE 960 Series - page 3

    3 Inst allatio n Al l p lumbing and ele ctric al connec tion s mus t c onf orm to local co des. Inspe ct uni t carefully for ca rrier sh or tag e or ship ping dam a ge . Loc ation Se l ect ion 1. The di stanc e be tween the uni t and a drai n sho uld b e as short as possibl e. 2 . If it is l ikel y that supplem en tar y wa te r treat me nt equ ipme ...

  • GE 960 Series - page 4

    4 4. W here the dra in line is elevated but em pti es into a drain b elow the lev el of the co ntro l valv e, form a 7-inch (18-cm) lo op at the f ar end of the line so tha t the b ott om of th e loop is level with the d rain l ine connection. This will p rovide an adequate siphon tr ap. 5. Wher e th e dr ain emptie s in to an ov erhead sewer l ine ...

  • GE 960 Series - page 5

    5 Pla ci ng Cond it io ner in t o Opera tion Aft er all previous st ep s have been complet ed , the unit is read y t o b e pl a ce d i n to o pe rat ion. F ol lo w t he s e s te ps care full y. 1. Re m ov e co nt ro l valv e co ve r by f irs t d ep ress i ng th e plas tic clips on the si de of the cover . Pull front of cove r up. Not e : The follow ...

  • GE 960 Series - page 6

    6 960 Pr oSo ft Con trol Cond itio ne r S yst e ms Fi gure 6 Pro grammi ng Thi s s ec tion cover s al l aspe ct s o f pr ogra mmin g the contr ol. The con trol is shipped fr o m the factory with def ault val ues for H ardness and Capacity. Th e se defau lt v alues w ill r esul t in a sy stem capac ity of 100 gallons (1 cubi c met er). While the con ...

  • GE 960 Series - page 7

    7 Tim e o f R ege ne rat ion The nex t value di splay ed is the T im e of Regen erati on. It has a defa ult v al ue of 2:00 a.m. If t his i s no t ac ce ptab le, press t he SE T butt on and ch ange th e numbe r . Pr ess the SE T bu tton to en ter t he valu e. If 2 :00 a .m. is accept able, press the dow n arrow ( ↓ ) b u tton. Hard ness Hard n es ...

  • GE 960 Series - page 8

    8 Level II Parameters (Tabl e 3) The Leve l II Pa r ameter s are P6 t hrough P19 i n Table 3. Th e Hom e Owner Manua l f or t hi s pr oduc t do es not menti o n these para me ter s, so th e e nd u se r doe s n ot norm al ly have access to these values. To access Level II Parameter s, simu ltan e ousl y pre ss and h ol d the do wn ar row ( ↓ ) and ...

  • GE 960 Series - page 9

    9 Table 3 - L evel II Program min g Parame ters Para meter Name Descri ptio n Range o f Value s Mi nim um Increm e nts Def aul t Units of Mea sur e Notes P6 Ref ill controller 1 to 99 1 33 Enter the value molded in t o the end of the r e f ill con troller . P7 Rege ne rant dra w val ue 1 to 99 1 25 Select number from T able 4 and enter that number ...

  • GE 960 Series - page 10

    10 Regeneran t Draw Value Param ete r P7 is used by the con trol to ca lcula te the rege ner an t dr aw ti me . Th e d e fa ult va lue of 2 5 was selected for a “B” injector with low water pressur e o r an “A ” inject or w ith m ode rat e wa te r pressure. If th is doe s no t matc h you r insta llati on, p ress the SET button and enter a ne ...

  • GE 960 Series - page 11

    11 Automatic Regeneration Th ere a r e tw o way s to hav e t he c ont r o l a u to ma ti ca ll y st ar t a regen erati on: c al enda r overri de or h aving the c ontrol mon itor th e water us age . Cal endar O verr ide This fea ture is set in Para m eter P14. It can be set for on e to 30 days. I f it is set t o zero, this f eature i s disable d. Wh ...

  • GE 960 Series - page 12

    12 Perfo rma 96 0 F A Co ntr ol 5-Cycle Filter S yst em Fi gure 8 This s ection co vers all aspects of pro g ramming the Performa 960 F A control. T he control i s shipped fro m the fac tor y w it h de fault v alu es for most pa rame ters. These default values will resul t in a syst em capacity o f 100 gall ons (1 cubic meter). While the co ntrol m ...

  • GE 960 Series - page 13

    13 Time o f Day Press the SE T button. T h e display w ill show the T ime of Day w ith t he m inutes d igit blinking . I f you want t o ch ange this n u mber , press the UP AR ROW ( ↑ ) button to in crease the n um ber or the DOW N ARROW ( ↓ ) butto n to de cre ase th e numb er . To sk ip th e nu mber wi th out c han gin g, pr ess the LEF T AR ...

  • GE 960 Series - page 14

    14 Table 5 -Perf orma 960 FA Level I Programming Parame ters Param eter R an ge of Valu es Mi nim u m In cremen ts Default Units of Measure Notes Nam e D esc r ip ti on P1 Ti m e o f d a y AM o r P M 1:00 to 12: 59 00:00 to 23: 59 1 Non e H our : minut e Range depends on value selected for P1 3. Enter the curr en t time. P2 T ime of day of reg en e ...

  • GE 960 Series - page 15

    15 Table 8 - Performa 960 FA Level II Programming Par ameters Param eter R an ge of Valu es Mi nim u m In cremen ts Default Units of Measure Notes Nam e D esc r ip ti on P6 R ef ill controller 1 to 99 1 33 Must be s et to 46 for Perfo rma 960 FA o pe r a t io n P7 Rege n erant draw valu e 1 t o 9 9 1 25 Select Regenerant Draw v alue from Table 9 an ...

  • GE 960 Series - page 16

    16 Perfo rma 96 0 F A Le vel I I Pa rameters The Leve l II Pa rameter s are P6 thr ough P19 in Tab le 8. The Opera ti ng and Mai ntena nce Manua l for th is pr oduct does n ot men tion th ese p aramet er s, so the end user d oes not n ormally have access to t hese va lues. T o a ccess Le vel II P arameters, simul tan e ous ly pre ss and hold the DO ...

  • GE 960 Series - page 17

    17 total capa city by the per centa ge enter e d f or Pa rame ter P 16 an d uses t hat v alue as the i n iti al averag e daily us age for eac h day of th e week un til water usage estab l ishe s ne w aver ag es. The defau lt is set for 30% of the cap ac ity . In most insta llation s th is is ac c ept ab l e. • Paramet er P17 has been preset to 0. ...

  • GE 960 Series - page 18

    18 Water Usa g e Patter n The other reser ve opti on allow s th e control to ad just the r e serve based u pon th e his t ori cal water us age pa t tern of the sy st em. Th e con trol kee ps tra ck o f the w at er usage f or each day o f t he week a nd use s th at d ay’ s a verage usage mul ti plie d by 1.2 as the re serve for that day . Ever y d ...

  • GE 960 Series - page 19

    19 Water Meter Maintenance The met erin g devic e used with th e 960 dema nd control s may r equi r e simpl e mai nt ena nce. I n rar e inst an ces, the turb ine wheel of the wat er met er can collect sm all par ticles o f o xidiz ed iron, even tually preventi ng the wh eel from tur ni n g. 1. Shut off the water supply or put th e bypass v alve( s) ...

  • GE 960 Series - page 20

    20 Fi gure 14 6 . Disconn ect the turb ine probe fr om th e turb ine as se m b ly. 7 . Lift the c ontrol off the val ve, Figu re 15. To replace the control, rever se the abov e procedure. No t e that the cam shaf t nee ds to be posit ioned cor rect ly befo re it can be inserted i nt o t he back of the co ntr ol. Th e r e is a loca ting ar row on th ...

  • GE 960 Series - page 21

    21 Sp ec if ica t io ns Hy dro sta tic Test Pre ss ure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 00 p si (20 . 69 ba r ) Wo rk in g P ress ure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • GE 960 Series - page 22

    22 Pr essure Gra phs 0.20 0.15 0.10 0.05 0.00 1.00 0.75 0.50 0.25 0.00 20 40 60 80 100 120 400 600 800 1000 1200 1400 1600 1800 Brine Draw Rinse To t a l PSI bar M /hr 3 GPM Injector #1031363 "A" in a 268 V alve 1.75 1.50 1.25 1.00 0.75 0.50 0.25 0.00 0.20 0.15 0.10 0.05 0.00 20 40 60 80 100 120 400 600 800 1000 1200 1400 1600 1800 Brine ...

  • GE 960 Series - page 23

    23 Ide n ti f ica ti on of Con tro l Val ving Brine Adjustment Brine Tan k Mineral Tank Drain Inlet Outlet Hard Water Soft Water 5 4 1 3 2 6 7 Brine Adjustment Brine Tan k Mineral Tank Drain Inlet Outlet Hard Water Soft Water 5 4 1 3 2 6 7 Backwash Flow Control 2 Back wash Position 1 Regene rant V alve 2 Bypass V al ve 3 Inlet V alve 4 Outl et V al ...

  • GE 960 Series - page 24

    24 Brine Adjustment Brine T ank Mineral T ank Drain Inlet Outlet Hard W ater Soft W ater 5 4 1 3 2 6 7 Brine Adjustment Brine T ank Mineral T ank Drain Inlet Outlet Hard W ater Soft W ater 5 4 1 3 2 6 7 Mineral T ank Brine Adjustment Brine T ank Mineral T ank Drain Inlet Outlet Hard W ater Soft W ater 5 4 1 3 2 6 7 3 Bri ning /Sl ow R inse Pos itio ...

  • GE 960 Series - page 25

    25 Replacement Parts 2 Performa Valve 3 4 14 9 1 5 6 10 11 7 8 12 12 13 15 ...

  • GE 960 Series - page 26

    26 Part s List * Not Shown Co de Par t No. Des c ri pti o n Q ty . C ode Par t No. De s cr ip tion Qty . 1 10 35807 Va lve As sem b ly, w/o F low Con t ro ls 1 11 103562 2 Ta nk Ring 1 2 10356 15 960 Stand ar d Camsh af t: 1 12 Plumb ing Ad a pter Kits: 1 3 Drain Cont rol Assembly: 1 10 01606 3/4 -inch Copper Tube Adapte r K it 10002 09 No. 7 (1.2 ...

  • GE 960 Series - page 27

    27 B Y P A S S B Y P A S S 1 2 1265 B ypass Cod e Par t No. Desc rip tio n Qty. 1 960 P r oS oft C on t rol 1 2 FA 1 3 1040 930 1265 B ypa s s 1 * 100 08 1 1 Tr a n s fo r m er 1 * 1 00090 7 Transformer Exte nsion Cord 1 1 5 feet (4.6 m ) * 1 03426 4 Y-Splitt er (run 2 units fro m 1 1 transf ormer) 960 P roS of t C ont ro l * No t Sho wn Perfo rma ...

  • GE 960 Series - page 28

    28 Tro ub l e s h o ot in g The t echno logy upon which t he Auto tr ol P e rfor ma contr ol v alv e is b ase d is we ll esta blish ed a nd pro ven in service over m any years. However , shou ld a problem or question arise reg ard ing t he o perat ion of t he syst em , th e control can very easily be serviced . For part s mentioned, refer to explod ...

  • GE 960 Series - page 29

    29 960 Co nt ro l Tr ou ble s ho ot ing Ala rm s The Model 960 con tinuously monitors itself and sounds an al arm i f it detects som e th ing wrong . The alarm i s a beep that is on for one sec o nd and the n off for nine se con ds . Wh en th e a larm so und s, the d ispla y sho ws the le tt ers “Er r ” with a numb e r from 1 to 4. T he t able ...

  • GE 960 Series - page 30

    30 Proble m Possible Ca use Solut ion 6. No wate r flow disp lay wh en water is flowin g (colon d oes not b li nk ). A . Byp ass valve in by pass po sition. B. M eter probe d isconnected or not fu lly connec ted to met er housing. C. Re stri ct ed m e te r tu rbine rota tio n du e t o fore ign ma te ria l in met er ! D . Defective meter probe. E. D ...

  • GE 960 Series - page 31

    31 Dis in f ec ti on of Wat e r Co nd it ione r s The ma te rials of cons tru ction of the mo de rn wat er conditioner wi ll not support bacterial gro wth, nor w ill these mate ri als c ont amina t e a wa ter suppl y. How ever , the nor mal co nditi ons exi sting d uring ship ping, stor age and insta llati on in d icate the a d visability o f disin ...

  • GE 960 Series - page 32

    © Copyri ght 2005 General Electr ic Company P r i n t ed i n U S A P / N 1227756 R e v . E ...

Manufacturer GE Category Water Dispenser

Documents that we receive from a manufacturer of a GE 960 Series can be divided into several groups. They are, among others:
- GE technical drawings
- 960 Series manuals
- GE product data sheets
- information booklets
- or energy labels GE 960 Series
All of them are important, but the most important information from the point of view of use of the device are in the user manual GE 960 Series.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals GE 960 Series, service manual, brief instructions and user manuals GE 960 Series. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product GE 960 Series.

Similar manuals

A complete manual for the device GE 960 Series, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use GE 960 Series by users. Manuals are usually written by a technical writer, but in a language understandable to all users of GE 960 Series.

A complete GE manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual GE 960 Series - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the GE 960 Series, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the GE 960 Series, that we can find in the current document
3. Tips how to use the basic functions of the device GE 960 Series - which should help us in our first steps of using GE 960 Series
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with GE 960 Series
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of GE 960 Series in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning GE 960 Series?

Use the form below

If you did not solve your problem by using a manual GE 960 Series, ask a question using the form below. If a user had a similar problem with GE 960 Series it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)