  • First Alert FA148CP - page 1

       3URJUDPPLQJ*XLGH ON OFF AR M E D R E A D Y A B C D 6 4 7 9 # 3 5 8 0 2 1 FA260 R A R M E D R E A D Y FA560 6 4 7 9 # 3 5 8 0 2 1 R AWAY STA Y P A G E K5305-5PRV2 10/03 Rev. A ) $  & 36   ) $  & 3   6 6 H H F F X X U U L L W W   6 6 V V W W H H P P V V  ...

  • First Alert FA148CP - page 2

    – 2 – TO ENTER PROGRAMMING MODE: Local programming requires the use of an alpha keypad connected to the keypad term inals on the control. A. PO WER UP, then depress [ ✱ ] and [#] both at once, within 50 seconds of powering up (if ✱ 98 was used to exit program mode, this method m ust be used to reenter program mode). OR B. Initially, key: In ...

  • First Alert FA148CP - page 3

    – 3 – 352*5$00,1*)250  Entries apply to both the FA168CPS and FA148CP controls, except entries shown in dashed boxes, which apply only to the FA168CPS (partition entries) and are not applicable to the FA148CP . Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults. Fie ...

  • First Alert FA148CP - page 4

    – 4 – NOTE: Entry of a number other than one specifie d will give unpredic table re sults. For fields *43 thr u *46: Enter 0 – 9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F. Enter [ ✱ ] as the fourth digit i f a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as the first digi t of a 4-digit account ...

  • First Alert FA148CP - page 5

    – 5 – ✱ 65 OPEN REPORT CODE [0,0,0] S ee box above. Part. 1 Part. 2 Common ✱ 66 ARM AWAY/STAY RPT CODE [0,0,0 ,0,0,0] See box above. Away Stay Away Stay Away Stay Part. 1 Part. 2 Common ✱ 67 RF XMTR LOW BAT REPORT CODE | [00] See box on previ ous page. UL: must be enabled if wi reless dev ices are used ✱ 68 CANCEL REPORT CODE | [00] See ...

  • First Alert FA148CP - page 6

    – 6 – ✱ 92 PHONE LINE MONITOR ENABLE UL: see Inst. Instru ctions for req uireme nts [0,0] 1 2 NOTE: Output Device must either be programmed to be STOPPED in fie ld ✱ 80 or STOPPED by Code + # + 8 + output number. Entry 1: : 0 = dis abled, 1-15 = 1 mi n - 15 min (#+10 = 10 min; #+11 = 11 mi n; #+12 = 12 min; #+13 = 13 min; #+14 = 14 min; #+1 ...

  • First Alert FA148CP - page 7

    – 7 – MISCELLANEOUS SYSTEM FIELDS (*174-*181) ✱ 174 CLEAN ME REPORTING OPTIONS (for ESL s moke det ectors ) [0] 0 = disabl e; 1 = Clean Me s ignal reports ; Note: If Clean M e is enabled, you must enter “ 3 ” in field ✱ 56 program ming for z one 1 response t ime. ✱ 177 DEVICE DURATION 1, 2 (used in *80 Menu mode-Dev ice A ctions 5/6) ...

  • First Alert FA148CP - page 8

    – 8 – Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed v ia downloader software or from a keypad us ing data fields*182-*185. Configurable z one types 92 and 93 (F A168CPS only) c an only be programmed us ing the downloader software. Programming Configurable Zone T ype options inv olves mak ing 10 entries i ...

  • First Alert FA148CP - page 9

    – 9 – *56 ZONE PROGRAMMING WORKSHEET (FA148CP supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets] Zone Zn Type Part. Report Hardw ire Type Rsp. Tim e Location 1 [09] [1] [EOL] [1] 2 [01] [1] [EOL] [1] 3 [03] [1] [EOL] [1] 4 [03] [1] [EOL] [1] 5 [03] [1] [EOL] [1] 6 [03] [1] [EOL] [1] 7 [03] [1] [EOL] [1] 8 [03] [1] [EOL] [1] ...

  • First Alert FA148CP - page 10

    – 10 – *57 FUNCTION KEY PROGRAMMING Option Function A B C D Comments 01 Paging 02 Time Disp lay 03 Arm AWAY 04 Arm STAY 05 Arm NIGHT-STAY 06 Step Armi ng 07 Device Activation Device: 08 Comm. Test 09 Macro Key 1 10 Macro Key 2 11 Macro Key 3 12 Macro Key 4 00 Emer gen cy Keys: zone 95 zone 99 zone 96 paging Personal Emergency n/a Silent Alarm n ...

  • First Alert FA148CP - page 11

    – 11 – ✱ 80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation m anual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, 4229 and 4204 devices are programmed in * 79, *80, and *81 modes. 2. For Powerline Carrier devices ...

  • First Alert FA148CP - page 12

    – 12 – Zone Type Definitions Type 00 Zone Not Used Use this zone ty pe if the z one is not used. Type 01 Entry/Exit Burglary #1 • Assi gn to zones that are us ed for primary entry and ex it. • Provides entry delay if the c ontrol is armed in t he Away or St ay modes . • No entry delay is prov ided when the panel is armed in the I nstant m ...

  • First Alert FA148CP - page 13

    – 13 – Type 21 Arm-Away • Arms th e system in Aw ay mode w hen the zone is ac tivat ed. • Pushbutton unit s send t he user number t o the cent ral stat ion when arming or dis arming. • User code for butt on must be assigned. Type 22 Disarm • Di sarms th e system w hen the zone is acti vated. • User code for butt on must be assigned. T ...

  • First Alert FA148CP - page 14

    – 14 – ALPHA VOCABULARY LIST (For Entering Zone Descriptors) 000 (Word Space) – A – • 001 AIR • 002 ALARM ∗ 004 A LLEY 005 AMBUSH • 006 AREA • 007 APARTM ENT • 009 ATTIC ∗ 010 A UDIO – B – • 012 BABY ∗ • 013 BACK ∗ • 014 BAR • 016 BASEMENT ∗ • 017 BATHROOM ∗ • 018 BED • 019 BEDROOM ∗ 020 B ELL • 0 ...

  • First Alert FA148CP - page 15

    – 15 – 5800 Series Transmitter Input Loop Identification All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones). WIRELESS INPUT TYPES "RF" (Supervised RF) Type send pe ...

  • First Alert FA148CP - page 16

    CLASS 2 PLUG-IN TRANSFORMER 16.5V AC, 25V A (e.g. 1321). (USE No. 1321CN IN CANADA) TO 110V AC UNSWITCHED OUTLET (24HR) THIS EQUIPMENT SHOULD BE INST ALLED IN ACCORD ANCE WITH THE NA TIONAL FIRE PROTECTION ASSOCIA TION'S ST ANDARD 72, CHAPTER 2 (NA TIONAL FIRE PROTECTION ASSOCIA TION, BA TTERY - MARCH P ARK, QUINCY ,MA 02269). PRINTED INFORMA ...

Manufacturer First Alert Category Home Security System

Documents that we receive from a manufacturer of a First Alert FA148CP can be divided into several groups. They are, among others:
- First Alert technical drawings
- FA148CP manuals
- First Alert product data sheets
- information booklets
- or energy labels First Alert FA148CP
All of them are important, but the most important information from the point of view of use of the device are in the user manual First Alert FA148CP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals First Alert FA148CP, service manual, brief instructions and user manuals First Alert FA148CP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product First Alert FA148CP.

A complete manual for the device First Alert FA148CP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use First Alert FA148CP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of First Alert FA148CP.

A complete First Alert manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual First Alert FA148CP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the First Alert FA148CP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the First Alert FA148CP, that we can find in the current document
3. Tips how to use the basic functions of the device First Alert FA148CP - which should help us in our first steps of using First Alert FA148CP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with First Alert FA148CP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of First Alert FA148CP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning First Alert FA148CP?

Use the form below

If you did not solve your problem by using a manual First Alert FA148CP, ask a question using the form below. If a user had a similar problem with First Alert FA148CP it is likely that he will want to share the way to solve it.

Copy the text from the picture