    Model 802 Series Quick Start Guide • 1 • Model 802 Series Quick S t art Guide ® This Quick Start Guide is designed to help get you up and running quickly with your generator.. Please see back cover for complete list of Models and Options covered by this manual. Index Page AC Power Requirements 2 Making Connections 2 Connector Pinouts 3 Normal ...

  • Quantum Data 802 - page 2

    • 2 • Model 802 Series Quick Start Guide Making Connections Notes: Some connectors shown are only available on some models and/or with certain hardware option configurations. The current firmware only fully supports use of the RS-232 and optional GPIB communications ports and has limited USB support. Version 3.00 of our VGM software supportsusi ...

  • Quantum Data 802 - page 3

    Model 802 Series Quick Start Guide • 3 • Making Connections # n i Pl a n g i S# n i Pl a n g i S# n i Pl a n g i S 1o e d i V d e R g o l a n A6 d n u o r G o e d i V g o l a n A1 1n o i t c e n n o C o N 2o e d i V n e e r G g o l a n A7 d n u o r G o e d i V g o l a n A2 1a t a D l a i r e S D I D E / C D D 3o e d i V e u l B g o l a n A8 d n ...

  • Quantum Data 802 - page 4

    • 4 • Model 802 Series Quick Start Guide Notes: If the format and image names are shifted to the left side of the LCD the unit is running in a user defined Test Sequence mode from the front panel. Information on creating a Test Sequence using VGM software is on page 16. Front Panel Controls and Indicators (Normal Mode) If there is a combination ...

  • Quantum Data 802 - page 5

    Model 802 Series Quick Start Guide • 5 • Special Operating Modes and Functions Mode _ Remove all modes Set GPIB Address Set baud rate to 9600 Enable programmable keypad Initialize w/factory defaults Calibrate Enable Programming Enable numeric keypad Clone Digital friendly mode Analog friendly mode Enable status display Old format library Hold a ...

  • Quantum Data 802 - page 6

    • 6 • Model 802 Series Quick Start Guide Power up Modes This section describes special operating modes that can only be selected when the generator is first powered up. The indicated buttons are held down and then the unit is powered up. Release the buttons when the LCD displays a message identifying the selected mode. Some operating modes will ...

  • Quantum Data 802 - page 7

    Model 802 Series Quick Start Guide • 7 • Power-up Modes Digital Friendly Mode This operating mode causes the generator to override a given format's analog video output type selection and output digital video. This mode is activated by holding down the indi- cated buttons on power up. Image Outputs STEP R G B ACS DCS DSS ON V ideo Gate Sync ...

  • Quantum Data 802 - page 8

    • 8 • Model 802 Series Quick Start Guide 802 Clone (Must be exact same model and firmware) Cloning allows you to program a generator at your desk using Quantum Data's VGM software and then easily and quickly transferring the information to other generators of the same model. You transfer (clone) the entire block of battery backed user memo ...

  • Quantum Data 802 - page 9

    Model 802 Series Quick Start Guide • 9 • Power-up Modes Serial Port Configuration The default setting of the RS-232 serial port is 2400 Baud, No Parity, 8 data bits, 1 Stop bit, No Handshaking (2400, N, 8, 1, N, N) and normal programming language support. The following special modes can be activated by holding down the indi- cated buttons on po ...

  • Quantum Data 802 - page 10

    • 10 • Model 802 Series Quick Start Guide Enable Status Display This mode replaces the Format Knob List index number to the left of the format name on the LCD with three characters that show the status of the selected format. It also replaces the Image Knob List index number to the left of the image name on the LCD with image version number. Th ...

  • Quantum Data 802 - page 11

    Model 802 Series Quick Start Guide • 11 • S pecial Key Functions This section describes special operating functions that can be selected once the generator is operating. These functions operate by holding down one of the indicated buttons while pressing and releasing the other button. If the primary gating function of the held button is inadver ...

  • Quantum Data 802 - page 12

    • 12 • Model 802 Series Quick Start Guide S pecial Key Functions DDC Based Autoconfiguration Image Outputs STEP R G B ACS DCS DSS ON V ideo Gate Sync Gate Creates a new format knob list based on video format information stored in the EDID structure of a VESA® DDC compliant monitor attached to the VGA or digital video connector. The generator b ...

  • Quantum Data 802 - page 13

    Model 802 Series Quick Start Guide • 13 • High-bandwid th Digit al Copy Protection (HDCP) T esting Video generators with optional DVI digital video outputs contain the required firmware and hardware to support the Intel® Corporation based HDCP down- stream protocol. This permits the generator to act as an HDCP signal source for testing HDCP co ...

  • Quantum Data 802 - page 14

    • 14 • Model 802 Series Quick Start Guide Using a Computer for Control and Programming Video Generator Manager (VGM) The VGM software package provides a graphical user interface that allows you to program our Bench Top, ISA card and PCI card Model 801 and 802 Series video genera- tors. You can also use the software to control the generator inst ...

  • Quantum Data 802 - page 15

    Model 802 Series Quick Start Guide • 15 • VGM Format Editor The current firmware in the Model 802 Series includes over 200 video formats that match the video and sync signals used by a wide variety of computers and imaging systems. You can store additional video formats in the generator's nonvolatile user memory. The format editor in VGM p ...

  • Quantum Data 802 - page 16

    • 16 • Model 802 Series Quick Start Guide VGM Sequence Editor Testing of a given model display may require repeated use of several differ- ent formats and images in a specific order. A sequence lets you pair up formats and images to form a single test step. Your create and organize the steps to match your test procedure for a particular display ...

  • Quantum Data 802 - page 17

    Model 802 Series Quick Start Guide • 17 • Instructions for Bitmap Picture Download: The bit map download function in VGM allows you to display, using the video generator, an image stored as a BMP file by your computer. The bit map is transferred directly to the video memory and the color information in the file is transferred directly to the co ...

  • Quantum Data 802 - page 18

    • 18 • Model 802 Series Quick Start Guide 5. You can either type the full path to the bit mapped file you wish to download or click on the “Browse” button. The browse button opens a standard MS-Windows “Open File” dialog box. You can then navigate to the desired file and open it. 6. If you selected a valid BMP file, its dimensions will ...

  • Quantum Data 802 - page 19

    Model 802 Series Quick Start Guide • 19 • Updating Generator Firmware All Model 802 generators can be reprogrammed with new operating system firmware using VGM software. A working copy of the firmware must be in the generator to install new firmware. Please refer to the VGM documentation and help file for information on how to install new firmw ...

  • Quantum Data 802 - page 20

    • 20 • Model 802 Series Quick Start Guide "Model 802 Series Quick Start Guide" Part # 68-00193 Rev. D (23-October-2001) Entire contents Copyright ©2001 by Quantum Data, Inc. All rights reserved. The information contained in this docu- ment is provided for use by our cus- tomers and may not be incorporated into other products or publi ...

Manufacturer Quantum Data Category Portable Generator

Documents that we receive from a manufacturer of a Quantum Data 802 can be divided into several groups. They are, among others:
- Quantum Data technical drawings
- 802 manuals
- Quantum Data product data sheets
- information booklets
- or energy labels Quantum Data 802
All of them are important, but the most important information from the point of view of use of the device are in the user manual Quantum Data 802.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Quantum Data 802, service manual, brief instructions and user manuals Quantum Data 802. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Quantum Data 802.

A complete manual for the device Quantum Data 802, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Quantum Data 802 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Quantum Data 802.

A complete Quantum Data manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Quantum Data 802 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Quantum Data 802, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Quantum Data 802, that we can find in the current document
3. Tips how to use the basic functions of the device Quantum Data 802 - which should help us in our first steps of using Quantum Data 802
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Quantum Data 802
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Quantum Data 802 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Quantum Data 802?

Use the form below

If you did not solve your problem by using a manual Quantum Data 802, ask a question using the form below. If a user had a similar problem with Quantum Data 802 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)