    bus CT-100B S ERIES S IX -S LOT VXI BUS C HASSIS U SER ’ S M ANUAL 82-0042-000 Rev. April 7, 2003 VXI Technology, Inc. 2031 Main Street Irvine, CA 92614-6509 (949) 955-1894 ...

  • VXI Six-Slot VXIBus Chassis - page 2

    VXI Technology, Inc. 2 ...

  • VXI Six-Slot VXIBus Chassis - page 3

    www.vxitech.com CT-100B Preface 3 T ABLE OF C ONTENTS I NTRODUCTION Certifi cation .................................................................................................................. ..................................... 4 Warranty ....................................................................................................... ...

  • VXI Six-Slot VXIBus Chassis - page 4

    VXI Technology, Inc. 4 CT-100B Preface C ERTIFICATION VXI Technology, Inc. (VTI) certifies t hat this product m et its publis hed specifications at the t ime of shipm ent from the factory. VTI further certifies that its calibration m easurements are traceable to the United States National Institute of Standards and T echnology (formerly National Bu ...

  • VXI Six-Slot VXIBus Chassis - page 5

    www.vxitech.com CT-100B Preface 5 D ECLARATION OF C ONFORMITY Declaration of Conformity According to ISO/IEC Guide 22 and EN 45014 M ANUFACTURER ’ S N AME VXI Technology, Inc. M ANUFACTURER ’ S A DDRESS 2031 Main Street Irvine, Californi a 92614-6509 P RODUCT N AME Six-Slot VXIbus Chassis M ODEL N UMBER ( S ) CT-100B P RODUCT O PTIONS All P ROD ...

  • VXI Six-Slot VXIBus Chassis - page 6

    VXI Technology, Inc. 6 CT-100B Preface ...

  • VXI Six-Slot VXIBus Chassis - page 7

    www.vxitech.com CT-100B Preface 7 G ENERAL S AFETY I NSTRUCTIONS Review the following safety precau tions to avoid bodily injury a nd/or damage to the product. These precautions must be observed during all phase s of operation or service of this product. Failure to comply with these pr ecautions, or with specific warni ngs elsewhere in this m anual ...

  • VXI Six-Slot VXIBus Chassis - page 8

    VXI Technology, Inc. 8 CT-100B Preface W ARNINGS (C ONT .) Avoid Electric Shock To avoid electric shoc k or fire hazard, do not operate this product with the covers rem oved. Do not connect or disconnect any cable, probes, test leads, etc. while they are connected to a voltage source. Rem ove all power and unplug unit before perform ing any service ...

  • VXI Six-Slot VXIBus Chassis - page 9

    www.vxitech.com CT-100B Preface 9 S UPPORT R ESOURCES Support resources for this product are availa ble on the Internet and at VXI Technology customer support centers. Internet Support E-mail: support@vxitech.com Web Address: http://www.vxitech.com Telephone Support (U.S.) Tel: (949) 955-1894 West Coast (216) 447-8950 East Coast Fax: (949) 955-3041 ...

  • VXI Six-Slot VXIBus Chassis - page 10

    VXI Technology, Inc. 10 CT-100B Preface ...

  • VXI Six-Slot VXIBus Chassis - page 11

    www.vxitech.com CT-100B Introducti on 11 S ECTION 1 I NTRODUCTION I NTRODUCTION The CT-100B portable C-size VXIbus m ainfram e provides cost-effective test si tuations in a sm all footprint. When using VMIP  instrum ents such as DMMs, wavefo rm generators, di gitizers, etc., complete test scenarios can easily be configured. F IGURE 1-1 CT-100B S ...

  • VXI Six-Slot VXIBus Chassis - page 12

    VXI Technology, Inc. 12 CT-100B Introducti on G ENERAL D ESCRIPTION The CT-100B chassis is a portabl e, C-size, six-slot, VXIbus com patible chassis that conform s fully to VXIbus Specification Revision 1.4. The chassis employs a multi-layer backplane to ensure premium VXIbus and VMEbus performance and provides al l power supplies required by the V ...

  • VXI Six-Slot VXIBus Chassis - page 13

    www.vxitech.com CT-100B Installa tion 13 F LEXIBILITY The CT-100B is designed to provi de flexibility of use in bench- top and rack-mount applications, as well as in portable environments. The out side cover is rem ovable for easy access to the VXIbus modules during bench-t op development, troubleshooting or cali bration. For rack-mount application ...

  • VXI Six-Slot VXIBus Chassis - page 14

    VXI Technology, Inc. 14 CT-100B Introducti on CT-100B S ERIES S PECIFICATIONS G ENERAL S PECIFICATIONS S IZE 8.2” W x 15” H x 21” D without feet and handle 8.5” W x 17” H x 21” D with feet and handle Six C-Size VXIbus card slots W EIGHT 28 lbs (12.7 kg) VXIbus Version 1.4 MTTR 30 min E NVIRONMENTAL S PECIFICATIONS O PERATING L OCATION T ...

  • VXI Six-Slot VXIBus Chassis - page 15

    www.vxitech.com CT-100B Installa tion 15 P OWER S PECIFICATIONS U SEABLE P OWER 450 W at 40°C DC Supply Voltage Voltage Peak Current (I MP ) Dynamic Current (I MD ) +5 V 35 A 5 A -5.2 V 25 A 4 A -2 V 7 A 2 A +12 V 4 A 2 A -12 V 4 A 1.5 A +24 V 4 A 3 A -24 V 4 A 3 A Output Voltage Voltage Allowed Variation Ripple/Noise DC Load Induced Ripple Noise ...

  • VXI Six-Slot VXIBus Chassis - page 16

    VXI Technology, Inc. 16 CT-100B Introducti on C OOLING S PECIFICATIONS C OOLING R EQUIREMENTS (TBD) 60 W/slot for a 10°C Rise 80 W/slot for a 15°C Rise A IR F LOW P ATH Air is drawn into the chassis fro m the r ear and is pressurized below the cards. The air is then distributed across all sl ots along the total length of each slot and is exhauste ...

  • VXI Six-Slot VXIBus Chassis - page 17

    www.vxitech.com CT-100B Installa tion 17 +5 STANDBY +5 STANDBY RETURN FUSE 10A 1 15VAC 5A 230V AC 8.100 (205.74) 21.000 (533.40) VXI Technology -2V -24V -12V -5 . 2 V + 5V STBY + 24V + 12V + 5V 0 1 0 1 2 3 4 5 V OL TAGE MONI TOR bus -2V -24V -12V -5 . 2 V + 5V STBY + 24V + 12V + 5V CT100B Mai nframe 0 1 VOLTAGE MON ITOR 0.343 (8.71) 16.404 (416.66) ...

  • VXI Six-Slot VXIBus Chassis - page 18

    VXI Technology, Inc. 18 CT-100B Introducti on ...

  • VXI Six-Slot VXIBus Chassis - page 19

    www.vxitech.com CT-100B Installa tion 19 S ECTION 2 I NSTALLATION I NTRODUCTION When the CT-100B is unpacked from i ts shipping carton, the cont ents should include the following items: (1) CT-100B Six-Slot C hassis (1) CT-100B Module User’s Ma nual (this m anual) (2) Replacement fuses, one 10 A sl ow blow, one 5 A slow blow (1) Power cord All co ...

  • VXI Six-Slot VXIBus Chassis - page 20

    VXI Technology, Inc. 20 CT-100B Installati on +5 ST AN DBY +5 ST AN DBY RETURN FUSE 10A 115VAC 5A 230V AC F IGURE 2-1 CT-100B B ACK P ANEL ...

  • VXI Six-Slot VXIBus Chassis - page 21

    www.vxitech.com CT-100B Installa tion 21 R ACK M OUNT O PTION I NSTALLATION O VERVIEW This section contains the procedures for i nstalling a CT-100B chassis in a standard 19” relay rack. The available rack mounting options are: Option 52 – Rack Mount Ear Ki t Option 53 – Rack Mount Door Ki t Option 57 – 20” Slide Kit Option 58 – 24” S ...

  • VXI Six-Slot VXIBus Chassis - page 22

    VXI Technology, Inc. 22 CT-100B Installati on R ACK M OUNT K IT I NSTALLATION The rack mount kit (Option 59) provides the ba sic hardware necessary to rack m ount the CT-100B chassis. With the chassis being onl y 15” wide, standard rack support rail s cannot provide mechanical support to the chassis. If the equipm ent mounted below the CT-100B ca ...

  • VXI Six-Slot VXIBus Chassis - page 23

    www.vxitech.com CT-100B Installa tion 23 Blac k Oxi de Pan Head Ph illips S crew s (x 4) Rack M ount Ea rs (x2) Flu sh Rack mount C onfigura tion * Recessed Rack Mount Installation Shown F IGURE 2.2: R ACK M OUNT E AR I NSTALLATION D IAGRAM ...

  • VXI Six-Slot VXIBus Chassis - page 24

    VXI Technology, Inc. 24 CT-100B Installati on R ACK S LIDE I NSTALLATION (20” AND 24”) The 20” and 24” slide hardware kits (Options 63 and 64, respect ively) provide standard flanges t o mount the sli des into standard EIA relay racks. It should be not ed that the slide flanges in the front should be installed behind the rack’s front pane ...

  • VXI Six-Slot VXIBus Chassis - page 25

    www.vxitech.com CT-100B Installa tion 25 5. Locat e the slide hardware kit provided. Instal l the rack flanges to the slides as required by the application using the hardware in the kit. Note that the screws are inserted from the inside of the slides and the nuts would show on the out side. 6. Inst all the slides to the m ounting brackets already i ...

  • VXI Six-Slot VXIBus Chassis - page 26

    VXI Technology, Inc. 26 CT-100B Installati on R ACK M OUNT D OOR K IT I NSTALLATION The rack mount door kit (Option 60) provides the necessary hardware to install a 1/8” thick aluminum door in front of the rack mounted chassis. This option requi res that the rack mount ear kit also be install ed and configured for recessed mounti ng. The door may ...

  • VXI Six-Slot VXIBus Chassis - page 27

    www.vxitech.com CT-100B Installa tion 27 Hinges (x2) 3/8” Flat H ead Phillips Screws (x4) Rackmount Brac es (x 2) 3/8” Pan Head Blac k Oxide Phillips Screws (x8) Front Door , Aluminum Door Latch Kit Front Door Stop 1/2” Pan H ead Phillips Screws (x2) 6-32 Hex Nuts (x2) F IGURE 2.4: R ACK D OOR I NSTALLATION D IAGRAM ...

  • VXI Six-Slot VXIBus Chassis - page 28

    VXI Technology, Inc. 28 CT-100B Installati on A CRYLIC R ACK M OUNT D OOR K IT I NSTALLATION An acrylic rack m ount door is offered as an alternat ive to the alum inum rack m ount door. The kit (Option 65) provides the necessary hardware to inst all a 1/8” thick acry lic door in front of the rack mounted chassis. An i nstallation diagram is provi ...

  • VXI Six-Slot VXIBus Chassis - page 29

    www.vxitech.com CT-100B Installa tion 29 6. Locate the four tapped holes on the front surface of the rack m ount ear to which the door is to be attached. 7. Inst all the door by it s hinges to the rack mount ear using four 3/8” black pan head screws provided with the opti on kit. 8. Test that the door opens and closes smoothly and adjust the la t ...

  • VXI Six-Slot VXIBus Chassis - page 30

    VXI Technology, Inc. 30 CT-100B Installati on ...

  • VXI Six-Slot VXIBus Chassis - page 31

    www.vxitech.com CT-100B Operation 31 S ECTION 3 O PERATION I NTRODUCTION There are no operating instructions requi red for the CT-100B VXIbus chassis. After the chassi s is installed, operation is com p letely transparent to the operator. Just plug in the instruments then power up the chassis. The power supply lines are m onitored and displayed on ...

  • VXI Six-Slot VXIBus Chassis - page 32

    VXI Technology, Inc. 32 CT-100B Operation VXI T echnolo gy -2V -24V -12V -5.2V + 5V STBY + 24V + 12V + 5V 0 1 0 1 2 3 4 5 VOL TAGE MONITOR bus -2V -24V -12V -5.2V + 5V STBY + 24V + 12V + 5V CT 10 0B M ainf rame 0 1 VOL TAGE MONITOR Green Not Lit Red : Within V ol tage S peci ficati ons : Under V oltage : Over V oltage V ol tage Monitor LEDs F IGURE ...

  • VXI Six-Slot VXIBus Chassis - page 33

    www.vxitech.com CT-100B Index 33 I NDEX # 5V STANDB Y................................................................ 12 A airflow....................................................................... 12, 15 B backplan e ........................................................................ 12 backplane conf iguration............................ ...

Manufacturer VXI Category Medical Alarms

Documents that we receive from a manufacturer of a VXI Six-Slot VXIBus Chassis can be divided into several groups. They are, among others:
- VXI technical drawings
- Six-Slot Bus Chassis manuals
- VXI product data sheets
- information booklets
- or energy labels VXI Six-Slot VXIBus Chassis
All of them are important, but the most important information from the point of view of use of the device are in the user manual VXI Six-Slot VXIBus Chassis.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals VXI Six-Slot VXIBus Chassis, service manual, brief instructions and user manuals VXI Six-Slot VXIBus Chassis. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product VXI Six-Slot VXIBus Chassis.

Similar manuals

A complete manual for the device VXI Six-Slot VXIBus Chassis, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use VXI Six-Slot VXIBus Chassis by users. Manuals are usually written by a technical writer, but in a language understandable to all users of VXI Six-Slot VXIBus Chassis.

A complete VXI manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual VXI Six-Slot VXIBus Chassis - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the VXI Six-Slot VXIBus Chassis, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the VXI Six-Slot VXIBus Chassis, that we can find in the current document
3. Tips how to use the basic functions of the device VXI Six-Slot VXIBus Chassis - which should help us in our first steps of using VXI Six-Slot VXIBus Chassis
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with VXI Six-Slot VXIBus Chassis
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of VXI Six-Slot VXIBus Chassis in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning VXI Six-Slot VXIBus Chassis?

Use the form below

If you did not solve your problem by using a manual VXI Six-Slot VXIBus Chassis, ask a question using the form below. If a user had a similar problem with VXI Six-Slot VXIBus Chassis it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)