  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 1

    PS-025 QuarterHorse Series 0.25 hp Portable Chiller Operation and Installation Manual ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 2

    Page 2 PS QuarterHorse Series Chillers AEC, Inc./Application Engineering is commi tted to a continuing program of product improvement. Specifications, appearance, and dimensions described in this manual are subject to change without notice. © Copyright AEC/Application Engineering and AEC, Inc. 2002 All rights reserved. Effective 9/24/02 ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 3

    PS QuarterHorse Series Chillers Page 3 Safety Considerations PS Series Chillers are designed to provide safe and reliable operation when installed and operated within design specifications, following national and local safety codes. To avoid possible personnel injury or equipment damage when installing, operating or maintaining this equipment, use ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 4

    Page 4 PS QuarterHorse Series Chillers Table of Contents 1 General Information ................................................. 7 1-1 Introduction 1-2 Necessary Documents 1-3 Models Covered 1-4 Available Options 1-5 Uncrating Your New Chiller 1-6 In the Event of Shipping Damages 1-7 If the Shipment is Not Complete 1-8 If the Shipment is Incorrect ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 5

    PS QuarterHorse Series Chillers Page 5 Table of Contents 4 Startup Checklists .................................................. 17 4-1 Introduction 4-2 PS Pre-Startup Checklist 4-3 PS Startup Checklist 5 Microprocessor Control ......................................... 19 5-1 Introduction 5-2 Setting the Process Water Temperature 5-3 Power Switch 6 ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 6

    Page 6 PS QuarterHorse Series Chillers Charts and Figures 1 PS050A Process Pump Curves 10 2 PS Series Chiller Specifications 10 3 Ethylene Glycol Curve 13 4 Overhead Piping 14 ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 7

    PS QuarterHorse Series Chillers Page 7 1 General Information 1-1 Introduction PS Series Water Chillers are reliable, accurate, and easy-to-use air cooled chillers designed for use with water/glycol. Standard range of operation is 50 ° F to 70 ° F (10°C to 21°C). This PS chiller is a ¼ hp (187 W) model and has an internal one gallon (3.8 liter) ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 8

    Page 8 PS QuarterHorse Series Chillers 1-4 Available Options PS Series chillers are available with options that tailor the unit to your requirements. Some are factory installed, some can be retrofitted in the field. Consult your local Application Engineering Sales Representative. Some of these options are: Power Cord A 6 foot (1.8 m) power cord is ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 9

    PS QuarterHorse Series Chillers Page 9 1-6 In the Event of Shipping Damages Important! According to the contract terms and conditions of the Carrier, the responsibility of the Shipper ends at the time and place of shipment. ; Notify the transportation company’s local agent. ; Hold the damaged goods and packing material for the exam ining agent’ ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 10

    Page 10 PS QuarterHorse Series Chillers 1-9 Returns Important! Do not return any damaged or incorrect items until you receive shipping instructions from Application Engineering. Figure 1 PS025 Process Pump Curve 6 0 HE RTZ P UMP CURV E C U R VES R EPR ESEN T PUMP DI SC H A RG E A D JU STE D F OR I N TERN A L B Y -P ASS PS 0 25 - P R O C E S S P U M ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 11

    PS QuarterHorse Series Chillers Page 11 2 Chiller Installation 2-1 Electrical Connections Check serial tag voltage and amperage requirements and m ake sure your electrical service conforms. See Figure 2 on Page 10 for total running amps. ; Electrical connections must comp ly with all applicable electrical codes. ; The chiller must be grounded in ac ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 12

    Page 12 PS QuarterHorse Series Chillers Process Water Bypass All PS chillers have an internal bypass device. If the process flow becomes blocked during chiller operation, this component allows water to flow through the chiller. This protects the chiller from freeze-up, excessive pressures, and pump dam age, and allows other safety features to remai ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 13

    PS QuarterHorse Series Chillers Page 13 ; If you want to use straight water, contact Application Engineering’s, Engineering Department. ; The 1 gallon (3.8 liter) reservoir is not designed to withstand water pressure above 5 psi (34 kPa). ; The fill opening and vent line must be vented to the atm osphere for proper operation. Properly Venting and ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 14

    Page 14 PS QuarterHorse Series Chillers 2-5 Overhead Process Considerations If your application has chilled water or process piping above the reservoir fill and vent level, install a standpipe to a point 1’ (30 cm) above the highest point in the system. In applications where the process or its piping is 15 feet (4.6 m) or more above the reservoir ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 15

    PS QuarterHorse Series Chillers Page 15 3 Sequence of Operation Important! The PS unit has a leaving water temperature range of 50°F to 70°F (10°C to 18°C). Do not attempt to run the PS unit outside this temperature range or damage to the unit may occur . 3-1 Chilled Water Circuit ; Process cooling water supply and return connections are made a ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 16

    Page 16 PS QuarterHorse Series Chillers - Notes - ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 17

    PS-025 QuarterHorse Series 0.25 hp Portable Chiller Operation and Installation Manual ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 18

    Page 18 PS QuarterHorse Series Chillers - Notes - ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 19

    PS QuarterHorse Series Chillers Page 19 5 Microprocessor Control 5-1 Introduction Standard PS Series chillers use a microprocessor based controller. The controller is a modular, self-contained unit that can slide from its m ounting housing. It is factory set and adjusted; no field adjustment to the internal controls is necessary. 5-2 Setting the Pr ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 20

    Page 20 PS QuarterHorse Series Chillers - Notes - ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 21

    PS QuarterHorse Series Chillers Page 21 6 Routine Maintenance 6-1 Lubrication Every three months, grease all fan motors and pum p motors that do not have permanently sealed bearings. Remove grease relief plug (m otors only) before adding grease. Failure to do so may result in dislodging the bearing grease retainer, eventually causing bearing failur ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 22

    Page 22 PS QuarterHorse Series Chillers - Notes - ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 23

    PS QuarterHorse Series Chillers Page 23 7 Troubleshooting Guide Problem Possible cause Solution No power. Check main disconnect fuses, wiring, and power lead to the unit. Wrong voltage supplied to the chiller. Voltage must be within plus or minus 10% of the nameplate rating. Defective on/off switch. Replace. Control circuit fuse blown. Replace, che ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 24

    Page 24 PS QuarterHorse Series Chillers Service Notes ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 25

    PS QuarterHorse Series Chillers Page 25 Service Notes ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 26

    Page 26 PS QuarterHorse Series Chillers Parts Department Call toll-free 7am–6pm CST [ 800 ] 423-3183 or call [ 847 ] 273 - 7700 The AEC/Application Engineering Parts Depar tment at AEC, Inc. is ready to prov ide the parts to keep your systems up and running. AEC/Application Engineeri ng replacement parts ens ure operation at design specifications ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 27

    Warranty AEC, Inc. warrants all equipment manufactured by it to be free from defects in workmanship and material when used under recomme nded conditions. The Company’s obligation i s limited to repair or replace FOB the factory any parts that ar e returned prepa id within one year of equipment shipment to the original purcha ser, and whic h, in t ...

  • HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - page 28

    801 AEC Drive • Wood Dale, IL 60191-1198 USA (630) 595-1060 • Fax (630) 595-6641 http://www.aecinternet.com ...

Manufacturer HP Category Refrigerator

Documents that we receive from a manufacturer of a HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 can be divided into several groups. They are, among others:
- HP technical drawings
- QuarterHorse Series 0.25 hp Portable Chiller PS-025 manuals
- HP product data sheets
- information booklets
- or energy labels HP QuarterHorse Series 0.25 hp Portable Chiller PS-025
All of them are important, but the most important information from the point of view of use of the device are in the user manual HP QuarterHorse Series 0.25 hp Portable Chiller PS-025.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals HP QuarterHorse Series 0.25 hp Portable Chiller PS-025, service manual, brief instructions and user manuals HP QuarterHorse Series 0.25 hp Portable Chiller PS-025. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product HP QuarterHorse Series 0.25 hp Portable Chiller PS-025.

A complete manual for the device HP QuarterHorse Series 0.25 hp Portable Chiller PS-025, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of HP QuarterHorse Series 0.25 hp Portable Chiller PS-025.

A complete HP manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the HP QuarterHorse Series 0.25 hp Portable Chiller PS-025, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the HP QuarterHorse Series 0.25 hp Portable Chiller PS-025, that we can find in the current document
3. Tips how to use the basic functions of the device HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 - which should help us in our first steps of using HP QuarterHorse Series 0.25 hp Portable Chiller PS-025
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with HP QuarterHorse Series 0.25 hp Portable Chiller PS-025
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning HP QuarterHorse Series 0.25 hp Portable Chiller PS-025?

Use the form below

If you did not solve your problem by using a manual HP QuarterHorse Series 0.25 hp Portable Chiller PS-025, ask a question using the form below. If a user had a similar problem with HP QuarterHorse Series 0.25 hp Portable Chiller PS-025 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)