    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 1 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch any electrical switch. DO NOT use any phone in your building. ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 2

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealership purchased from: _ ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 3

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 4

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 4  = Contains updated information. 13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 45 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 14 Appliance Setup A. Remove Fixed Glass Assembly . ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 5

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 5 B. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT deale ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 6

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 6 B. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating mate ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 7

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 7 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commission (CPSC). The tempered glass ha ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 8

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 9

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 9 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . DECORA TIVE DOORS (NO ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 10

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects. Fig ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 11

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 1 1 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when using the transformer . 1. Turn off all electric power to the appliance. 2. This applian ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 12

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 12 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace of f and allow it to completely cool. • Remove fi xed glass assembly . See Section 14.I. • Clean fi xed glass assembly . See Section 3. ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 13

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 13 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming glass • Avoid ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 14

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 14 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc. • V erify termination cap clearance to subseque ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 15

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 15 (Either cobrahead or SIT) Figure 3.1 IPI Pilot Flame Patterns ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 16

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 16 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.1 T ypical System Note: Dual venti ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 17

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 17 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. Insta ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 18

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 18 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and f ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 19

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 19 C B D A B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: T reatment of ceiling fi restops and wall shield ? ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 20

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 20 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 21

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 21 Figure 6.3 Leveled T ermination Caps A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 22

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 22 O N P R Q V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 6.4 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches................. clearances to ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 23

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 23 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP venting systems. Refer to Section 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers. The pipe is tested to be r ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 24

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 24 V 1 Minimum H 1 + H 2 Maximum 1 ft. 305 mm Cannot do 1 1/2 ft. 457 mm 1-1/2 ft. 457 mm 2 ft. 610 mm 3 ft. 914 mm 3 ft. 914 mm 6 ft. 1.8 m 4 ft. 1.2 m 9 ft. 2.7 m V 1 + H 1 + H 2 = 50 ft. (15.2 m) Maximum H 1 + H 2 = 17 ft. (5.2 m) Maximum V 1 = 1 ft. (305 mm) Minimum ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 25

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 25 Figure 7.5 T op V ent - Horizontal T ermination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Minimum H 1 Maximum V 2 Minimum H 2 Maximum V 1 + V 2 Minimum H 1 + H 2 Maximum 6 in. 152 mm 3 ft 914 mm 1 ft 305 mm 3 ft 914 mm 1-1/2 ft 457 mm 6 ft 1.8 m 1 ft 305 mm 3 ft ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 26

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 26 T op V ent - V ertical T ermination No Elbow Figure 7.6 Note: If installing a vertical vent/termination of f the top of the appliance, the fl ue restrictor should be used. V 1 V 1 = 50 ft. Max. (15.2 m) V 1 = 3 ft. Min. (914 mm) Installing the fl ue restrictor Figur ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 27

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 27 Figure 7.1 1 T wo Elbows H 1 V 1 V 2 Three Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 2 T op V ent - V ertical T ermination - (continued) Figure 7.12 V 1 H 1 Maximum V 2 V 1 + V 2 Minimum 6 in. 152 mm 3 ft 914 mm * * * 1 ft 305 mm 3 ft 914 mm * * * 2 ft 607 mm 6 f ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 28

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 28 A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops • Between wall shield fi restops • Around vent system Failure to keep insulation or othe ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 29

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 29 A 12 in. 10 in. B Figure 8.6 W all Penetration B. W all Penetration Framing A* B 49-1/2 in, 48-1/2 in, Figure 8.5 Horizontal V enting Clearances to Combustible Materials 3 IN. TOP CLEARANCE HEA T SHIELD HEA T SHIELD WA LL WA LL SHIELD FIRESTOP 1 IN. CLEARANCE BOTTOM S ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 30

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 30 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.7). • Frame the area with the same s ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 31

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 31 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an attic shield cons ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 32

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 32 A. Attaching Sheetrock Ledges Attach sheetrock ledges together using the attachment holes (see Figure 9.1). Figure 9.1 The sheetrock ledges will attach to the top of the unit (see Figure 9.2). Figure 9.2 Attach previous assembly to the top of the unit using the provid ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 33

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 33 C. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation. M ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 34

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 34 1 0 10 Inst alli ng V ent Pipe A. Assemble V ent Sections Attach V ent to the Firebox Assembly Note: The end of th e pipe secti ons with the lanc ed tabs will f ace toward the applianc e. Attach the fi rst pipe section to the starting collar: • Lanced pipe end to t ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 35

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 35 B. Assemble Slip Sections • Slide the inner fl ue of the slip section into the inner fl ue of the pipe section and the outer fl ue of the slip section over the outer fl ue of the pipe section. See Figure 10.6. • Slide together to the desired length. Figure 10. ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 36

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 36 D. Disassemble V ent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown in Figure 10.1 1. • Pull carefully to separate the pieces of pipe. Figure 10.1 1 Align and Disassemble V ent Sections Figure 10.10 Rota ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 37

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 37 E. Install Metal Roof Flashing Note : Skip this section if using the RF4-8. • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 38

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 38 G. Install RF4-8 The RF4-8 may be used in place of the roof fl ashing and storm collar (Sections 10.G. and 10.H.) Pipe must be supported within 12 inches of the roofline using plumbers strapping or an SLP-FS when using the RF4-8 Flashing. Refer to Section 10.D. Secur ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 39

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 39 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.23 Figure 10.23 TERMINA TION CAP H. Install V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 40

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 40 Figure 10.25 Venting through the wall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEA THING VENT DEPTH FROM BACK OF APPLIANCE T O OUTSIDE SURF ACE OF EXTERIOR WALL (SEE CHART BELOW) SLIP SECTION CAN ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 41

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 41 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts. B. Gas Pressure • Optimum appliance performan ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 42

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 42 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.1. • Wire the appl ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 43

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 43 D. Electrical Service and Repair W ARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing. Figure 12.2 Intelli fi re Pilot Ignition (I ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 44

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 44 F . W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.5): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from the switch box t ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 45

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 45 A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materi- als (i.e., steel studs, concrete board, etc.) Failure to comp ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 46

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 46 A. Remove Fixed Glass Assembly See Section 14.I. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the con ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 47

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 47 G. Ember Placement W ARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT place embers directly over burner ports. Replace ember material annually . Improperly placed embers interfere with proper burner operation. Ember material is shipped ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 48

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 48 H. Install the Log Assembly STEP 2. Place the metal grate on top of the burner . Position the legs of the grate into the forward set of indentations in the burner top. Make sure the grate is all the way forward. See Figure 14.9. Log Assembly: LOGS-6000G STEP 1. CAUTIO ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 49

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 49 Figure 14.19 T op View Figure 14.13 T op View STEP 5. Log #3 (SRV2103-1 10): Place log #3 on top of the burner surface in front of the hump. The bottom of the log has a square groove cut through it. The groove sits over the second grate tine from the left. Slide it ba ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 50

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 50 M. Air Shutter Setting Air shutter settings should be adjusted by a quali fi ed ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 14.21. • L ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 51

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 51 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service technician in the diagnosis of a p ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 52

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 52 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occ ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 53

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 53 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions A B C D E F G I J K L M N P Q GAS LINE ACCESS ELEC ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 54

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 54 B. V ent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in. (337 mm) 1/2 in. TYP DVP90ST (90° Elbow) 10 in. (254 mm) 10 in. (254 mm) ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 55

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 55 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 56

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 56 B. V ent Components Diagrams (continued) Figure 16.4 DVP vent components DVP-TB1 Basement Vent Cap 12 in. 1-1/2 in. 7-3/8 in. 14 in. 17-3/4 in. 10-1/2 in. 3-7/8 in. DVP-TV V ertical Termination Cap 13-1/4 in. 24-5/8 in. 27-1/2 in. RF6M Roof Flashing Multi-pak 31 in. 2 ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 57

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 57 B. V ent Components Diagrams (continued) DVP-HRC-SS DVP-HRC-ZC-SS HORIZONT AL TERMINA TION CAP 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 58

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 58 C. Service Parts Part number list on following page. Service Parts Diagram 6000GCF-IPI Beginning Manufacturing Date: May 2006 Ending Manufacturing Date: ______ 11 6 8 9 12 10 7 1 2 3 4 5 Log Set Assembly ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 59

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 59 C. Service Parts List 6000GCF-IPI IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stock ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 60

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 60 Intermittent Pilot Ignition V alve Assembly Service Parts V alve Assembly Diagram/ Parts List 6000GCF-IPI Beginning Manufacturing Date: May 2006 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts fo ...

  • Hearth and Home Technologies 6000GCF-IPIL - page 61

    Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 21 10-900 Rev . H • 1 1/08 61 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215th St, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer ...

Manufacturer Hearth and Home Technologies Category Indoor Fireplace

Documents that we receive from a manufacturer of a Hearth and Home Technologies 6000GCF-IPIL can be divided into several groups. They are, among others:
- Hearth and Home Technologies technical drawings
- 6000GCF-IPIL manuals
- Hearth and Home Technologies product data sheets
- information booklets
- or energy labels Hearth and Home Technologies 6000GCF-IPIL
All of them are important, but the most important information from the point of view of use of the device are in the user manual Hearth and Home Technologies 6000GCF-IPIL.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Hearth and Home Technologies 6000GCF-IPIL, service manual, brief instructions and user manuals Hearth and Home Technologies 6000GCF-IPIL. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Hearth and Home Technologies 6000GCF-IPIL.

A complete manual for the device Hearth and Home Technologies 6000GCF-IPIL, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Hearth and Home Technologies 6000GCF-IPIL by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Hearth and Home Technologies 6000GCF-IPIL.

A complete Hearth and Home Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Hearth and Home Technologies 6000GCF-IPIL - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Hearth and Home Technologies 6000GCF-IPIL, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Hearth and Home Technologies 6000GCF-IPIL, that we can find in the current document
3. Tips how to use the basic functions of the device Hearth and Home Technologies 6000GCF-IPIL - which should help us in our first steps of using Hearth and Home Technologies 6000GCF-IPIL
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Hearth and Home Technologies 6000GCF-IPIL
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Hearth and Home Technologies 6000GCF-IPIL in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Hearth and Home Technologies 6000GCF-IPIL?

Use the form below

If you did not solve your problem by using a manual Hearth and Home Technologies 6000GCF-IPIL, ask a question using the form below. If a user had a similar problem with Hearth and Home Technologies 6000GCF-IPIL it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)