Manual Hoshizaki KM-900MAF

65 pages 0.79 mb
Download

Go to site of 65

Summary
  • Hoshizaki KM-900MAF - page 1

    SER VICE MANUAL NO.: ISSUED: REVISED: MAR. 19, 1999 73083 HOSHIZAKI MODULAR CRESCENT CUBER MODELS KM-900MAF KM-900MWF KM-900MRF KM-900MRF3 DEC. 15, 2003 ...

  • Hoshizaki KM-900MAF - page 2

    2 IMPORT ANT Only qualified service technicians should attempt to service or maintain this icemaker. No service or maintenance should be undertaken until the technician has thoroughly read this Service Manual. HOSHIZAKI AMERICA, INC. 618 Highway 74 South Peachtree City , GA 30269 Attn: HOSHIZAKI T echnical Support Department Phone: 1-800-233-1940 T ...

  • Hoshizaki KM-900MAF - page 3

    3 Please review this manual. It should be read carefully before the icemaker is serviced or maintenance operations are performed. Only qualified service technicians should service and maintain the icemaker. This manual should be made available to the technician prior to service or maintenance. CONTENTS PAGE I. SPECIFICATIONS ....................... ...

  • Hoshizaki KM-900MAF - page 4

    4 IV. SERVICE DIAGNOSIS ........................................................................................... 40 1. NO ICE PRODUCTION ........................................................................................ 40 2. EVAPORATOR IS FROZEN UP .......................................................................... 43 3. LOW ICE PR ...

  • Hoshizaki KM-900MAF - page 5

    5 I. SPECIFICATIONS 1. KM-900MAF * We reserve the right to make changes in specifications and design without prior notice. ...

  • Hoshizaki KM-900MAF - page 6

    6 2. KM-900MWF * We reserve the right to make changes in specifications and design without prior notice. ...

  • Hoshizaki KM-900MAF - page 7

    7 3. KM-900MRF * We reserve the right to make changes in specifications and design without prior notice. ...

  • Hoshizaki KM-900MAF - page 8

    8 4. KM-900MRF3 * We reserve the right to make changes in specifications and design without prior notice. ...

  • Hoshizaki KM-900MAF - page 9

    9 5. CONDENSING UNIT URC-12F ...

  • Hoshizaki KM-900MAF - page 10

    10 SPECIFICATIONS MODEL: URC-12F EXTERIOR DIMENSIONS (W x D x H) REFRIGERANT CHARGE URC-12F WEIGHT CONNECTIONS REFRIGERANT ELECTRICAL CONDENSER HEAD PRESSURE CONTROL AMBIENT CONDITION Galvanized Steel 35 - 11/16” x 15-11/16” x 21-15/16” (907.2 x 398 x 557.8 mm) R404A 4 lbs. 7 oz. (2000 g) Net 80 lbs. (36 kg) Shipping 87 lbs. (39 kg) One Shot ...

  • Hoshizaki KM-900MAF - page 11

    11 II. GENERAL INFORMA TION 1. CONSTRUCTION [a] KM-900MAF ...

  • Hoshizaki KM-900MAF - page 12

    12 [b] KM-900MWF ...

  • Hoshizaki KM-900MAF - page 13

    13 [c] KM-900MRF ...

  • Hoshizaki KM-900MAF - page 14

    14 [d] KM-900MRF3 ...

  • Hoshizaki KM-900MAF - page 15

    15 2. CONTROLLER BOARD [a] SOLID-STATE CONTROL 1) A HOSHIZAKI exclusive solid-state control is employed in KM-900MAF, KM-900MWF, KM-900MRF and KM-900MRF3 Modular Crescent Cubers. 2) A Printed Circuit Board (hereafter called “Controller Board”) includes a stable and high quality control system. 3) All models are pretested and factory-adjusted. [ ...

  • Hoshizaki KM-900MAF - page 16

    16 2) Defrost Timer The defrost cycle starts when the Float Switch opens and completes the freeze cycle. But the Defrost Timer does not start counting until the Thermistor senses 48°F at the Evaporator outlet. The period from the end of the freeze cycle up to the point of the Thermistor's sensing varies depending on the ambient and water temp ...

  • Hoshizaki KM-900MAF - page 17

    17 problem occurs. At startup a 5 second delay occurs while the board conducts an internal timer check. A short beep occurs when the power switch is turned ON or OFF. The green LED’s 1-4 represent the corresponding relays and energize and sequence 5 seconds from initial startup as follows: Sequence Step LED’s on Length: Min. Max. Avg. 1 Minute ...

  • Hoshizaki KM-900MAF - page 18

    18 (Control Product s HOS-001A Board) to the K1 connector. If there is a white wire, place the switch in the C position. If this switch is placed in the wrong position either the compressor contactor will remain ener- gized with the control switch OFF or the unit will not start. The dip switches should be adjusted per the adjustment chart published ...

  • Hoshizaki KM-900MAF - page 19

    19 [c] SEQUENCE 1st Cycle 1. Unit energized and Control Switch to “ICE” position. Water supply cycle starts. 2. After 1 minute, Defrost cycle starts. 3. Thermistor reads 48° F. Defrost Timer starts counting. IMPORTANT Water Valve opening is limited to 6 minutes. & 5. After the first 5 minutes in freeze cycle. Ready to complete freeze cycle ...

  • Hoshizaki KM-900MAF - page 20

    20 2nd Cycle and after with pump drain IMPORTANT Freeze cycle time is limited to 60 minutes even if Float Switch does not open. 1. Float Switch opens and signals to complete freeze cycle. Drain timer starts counting. 2. Drain timer stops counting. Pump drain is completed 3. Thermistor reads 48° F. Defrost Timer starts counting. IMPORTANT Water Val ...

  • Hoshizaki KM-900MAF - page 21

    21 2nd Cycle and after with no pump drain IMPORTANT Freeze cycle time is limited to 60 minutes even if Float Switch does not open. 1. Float Switch opens and signals to complete freeze cycle. 2. Thermistor reads 48° F. Defrost Timer starts counting. IMPORTANT Water Valve opening is limited to 6 minutes. 4. After the first 5 minutes in freeze cycle. ...

  • Hoshizaki KM-900MAF - page 22

    22 DIP SWITCH NO. 1 2 3 4 5 6 7 8 9 10 KM-900MRF/3 OFF OFF ON OFF ON ON OFF OFF OFF ON KM-900MAF, OFF OFF ON OFF ON ON OFF OFF OFF ON KM-900MWF [d] CONTROLS AND ADJUSTMENTS The Dip Switch is factory-adjusted to the following positions: Switch Nos. 1 and 2: Used for adjustment of the Defrost Timer. The Defrost Timer starts counting when the Thermist ...

  • Hoshizaki KM-900MAF - page 23

    23 1) Defrost Control A thermistor (Semiconductor) is used for a defrost control sensor. The resistance var- ies depending on the Suction Line temperatures. The Thermistor detects the tempera- ture of the Evaporator outlet to start the Defrost Timer. No adjustment is required. If necessary, check for resistance between Thermistor leads, and visuall ...

  • Hoshizaki KM-900MAF - page 24

    24 3) Drain Timer The Drain Timer is factory-adjusted, and no adjustment is required. SETTING TIME Dip Switch Dip Switch No. 3 No. 4 T1 T2 OFF OFF 10 seconds 150 seconds ON OFF 10 seconds 180 seconds OFF ON 10 seconds 120 seconds ON ON 20 seconds 180 seconds T1: Time to drain the Water Tank T2: Time to restrain defrost completion 4) Drain Counter C ...

  • Hoshizaki KM-900MAF - page 25

    25 6) Bin Control CAUTION When the ambient temperature is below 45°F, the Bin Control Thermostat operates to stop the icemaker even if the Ice Storage Bin is empty. When the Thermostat is set in the prohibited range, the icemaker operates continuously even if the Ice Storage Bin is filled with ice. Setting in the prohibited range might cause sever ...

  • Hoshizaki KM-900MAF - page 26

    26 (iv) After Step (iii), de-energize the unit and confirm that the Defrost Timer is in the minimum position. Disconnect the resistor from the Controller Board, and ener- gize the unit. After the 1 minute water supply cycle, the defrost cycle starts. Re-connect a 1.5 k Ω - 3.5 k Ω resistor to the Connector K3 (pins #1 and #2) after the first 2 ...

  • Hoshizaki KM-900MAF - page 27

    27 III. TECHNICAL INFORMA TION 1. WATER CIRCUIT AND REFRIGERANT CIRCUIT [a] KM-900MAF ...

  • Hoshizaki KM-900MAF - page 28

    28 [b] KM-900MWF ...

  • Hoshizaki KM-900MAF - page 29

    29 [c] KM-900MRF and KM-900MRF3 ...

  • Hoshizaki KM-900MAF - page 30

    30 2. WIRING DIAGRAMS [a] KM-900MAF Note: Pressure Switch Cut-out 412 ± PSIG Cut-in 327 ± 21 PSIG 21 0 ...

  • Hoshizaki KM-900MAF - page 31

    31 [b] KM-900MWF Note: Pressure Switch Cut-out 412 ± PSIG Cut-in 327 ± 21 PSIG 21 0 ...

  • Hoshizaki KM-900MAF - page 32

    32 [c] KM-900MRF Note: Pressure Switch Cut-out 412 ± PSIG Cut-in 327 ± 21 PSIG 21 0 ...

  • Hoshizaki KM-900MAF - page 33

    33 [d] KM-900MRF3 Note: Pressure Switch Cut-out 412 ± PSIG Cut-in 327 ± 21 PSIG 21 0 ...

  • Hoshizaki KM-900MAF - page 34

    34 3. TIMING CHART Control Sw. in ICE Bin Thermo- stat ON Pressure Sw. ON Overheat Protect Reset Hi Temp Mid Temp Lo Temp Too Lo Temp Normal Too Hi Temp Lo Water Max. Min. 60 min 5 min Min. Max. Max. 2 min 6 min 6 min Max. 20 min Time Up (60 sec) If Float Sw. is OFF From Defrost Cycle When Control Sw. is turned OFF, Pressure Sw. is OFF, or Thermist ...

  • Hoshizaki KM-900MAF - page 35

    35 To Freeze Cycle To Stand-by Cycle (When Control Sw. is turned OFF, Pressure Sw. is OFF, or Thermistor Temp. exceeds t1.) From Freeze Cycle Control Sw. in WASH Min. Max. Max. 3 min 6 min 6 min Max. 20 min *1 The Pump Motor waits for 2 seconds before starting a drain cycle. See “II. 2. [d] CONTROLS AND ADJUSTMENTS.” *2 The icemaker does not co ...

  • Hoshizaki KM-900MAF - page 36

    36 4. PERFORMANCE DATA [a] KM-900MAF Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only. * We reserve the right to make changes in specifications and design without prior notice. ...

  • Hoshizaki KM-900MAF - page 37

    37 [b] KM-900MWF Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only. * We reserve the right to make changes in specifications and design without prior notice. ...

  • Hoshizaki KM-900MAF - page 38

    38 [c] KM-900MRF Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only. * We reserve the right to make changes in specifications and design without prior notice. ...

  • Hoshizaki KM-900MAF - page 39

    39 [b] KM-900MRF3 Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only. * We reserve the right to make changes in specifications and design without prior notice. ...

  • Hoshizaki KM-900MAF - page 40

    40 PROBLEM POSSIBLE CAUSE REMEDY [1] The icemaker a) Power Supply 1. “OFF” position. 1. Move to “ON” position will not start 2. Loose connections. 2. Tighten 3. Bad contacts. 3. Check for continuity and replace. 4. Voltage too high. 4. Check and get recommended voltage. b) Fuse (Inside Fused 1. Blown out. 1. Check for short circuit Disconne ...

  • Hoshizaki KM-900MAF - page 41

    41 PROBLEM POSSIBLE CAUSE REMEDY l) Controller Board 1. Defective 1. See “II.2[e] CHECKING CONTROLLER BOARD.” m) Interlock Switch 1. “OFF” position. 1. Move to “ON” position. (Cleaning Valve) 2. Bad contacts. 2. Check for continuity and replace. [2] Water a) Float switch 1. Connector disconnected. 1. Place in position. continues to 2. L ...

  • Hoshizaki KM-900MAF - page 42

    42 PROBLEM POSSIBLE CAUSE REMEDY [4] Water a) Water Solenoid 1. Diaphragm does not close. 1. Check for water leaks continues to Valve with icemaker off. be supplied in b) Controller Board 1. Defective. 1. See “II.2.[e] CHECKING freeze cycle. CONTROLLER BOARD.” [5] No water a) Water Supply Line 1. Water pressure too low and 1. Check and get come ...

  • Hoshizaki KM-900MAF - page 43

    43 PROBLEM POSSIBLE CAUSE REMEDY [1] Freeze cycle a) See chart 1 - [3], and check dirty Air Filter or Condenser, ambient or water time is long. temperature, water pressure, Water Regulator or refrigerant charge. b) See chart 2 - [1], and check Float Switch, Water Solenoid Valve or Controller Board. [2] Harvest cycle a) See chart 2 - [2], and check ...

  • Hoshizaki KM-900MAF - page 44

    44 PROBLEM POSSIBLE CAUSE REMEDY [1] Icemaker will a) Bin Control 1. Set too cold. 1. Adjust warmer. not stop when Thermostat 2. Defective. 2. Replace. bin is filled with ice. [2] Abnormal a) Pump Motor 1. Bearings worn out. 1. Replace. noise b) Fan Motor 1. Bearings worn out. 1. Replace. 2. Fan blade deformed. 2. Replace fan blade. 3. Fan blade do ...

  • Hoshizaki KM-900MAF - page 45

    45 V. REMOVAL AND REPLACEMENT OF COMPONENTS IMPORTANT Ensure all components, fasteners and thumbscrews are securely in place after the equipment is serviced. IMPORTANT 1. The Polyol Ester (POE) oils used in R-404A units can absorb moisture quickly. Therefore it is important to prevent moisture from entering the system when replacing or servicing pa ...

  • Hoshizaki KM-900MAF - page 46

    46 5) Disconnect the Vacuum Pump, and attach a Refrigerant Service Cylinder to the High- side line. Remember to loosen the connection, and purge the air from the Hose. See the Nameplate for the required refrigerant charge. Hoshizaki recommends only virgin refrigerant or reclaimed refrigerant which meets ARI Standard No. 700-88 be used. 6) A liquid ...

  • Hoshizaki KM-900MAF - page 47

    47 3. REMOV AL AND REPLACEMENT OF COMPRESSOR IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. Note: When replacing a Compressor with a defective winding, be sure to install the new Start Capacitor and Start Relay supplied w ...

  • Hoshizaki KM-900MAF - page 48

    48 15) Evacuate the system, and charge it with refrigerant. For air-cooled and water-cooled models, see the Nameplate for the required refrigerant charge. For remote air-cooled models, see the Charge Label in the machine compartment. 16) Connect the Terminals, and replace the Terminal Cover in its correct position. 17) Replace the panels in their c ...

  • Hoshizaki KM-900MAF - page 49

    49 4. REMOV AL AND REPLACEMENT OF DRIER IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply. 2) Remove the panels. 3) Recover the refrigerant and store it in an approved container. 4) Remove the Dr ...

  • Hoshizaki KM-900MAF - page 50

    50 3) Recover the refrigerant and store it in an approved container. 4) Remove the insulation and the Expansion Valve Bulb on the suction line. 5) Remove the Expansion Valve Cover, and disconnect the Expansion Valve using brazing equipment. 6) Braze the new Expansion Valve, with nitrogen gas flowing at the pressure of 3-4 PSIG. W ARNING Always prot ...

  • Hoshizaki KM-900MAF - page 51

    51 IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply. 2) Remove the panels. 3) Recover the refrigerant and store it in an approved container. 4) Remove the screw and the Solenoid. 5) Disconnect t ...

  • Hoshizaki KM-900MAF - page 52

    52 7. REMOV AL AND REPLACEMENT OF EV APORA TOR IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repairs or replacement have been made. 1) Turn off the power supply. 2) Remove the panels and the Top Insulation over the Evaporator. 3) Recover the refrigerant and ...

  • Hoshizaki KM-900MAF - page 53

    53 8. REMOV AL AND REPLACEMENT OF W A TER REGULA TING V AL VE - W A TER-COOLED MODEL ONL Y IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply. 2) Close the Water Supply Line Shut-off Valve. 3) Rem ...

  • Hoshizaki KM-900MAF - page 54

    54 9. ADJUSTMENT OF W A TER REGULA TING V AL VE - W A TER-COOLED MODEL ONL Y The Water Regulating Valve (also called “WATER REGULATOR”) is factory-adjusted. No adjustment is required under normal use. Adjust the Water Regulator, if necessary, using the following procedures. 1) Attach a pressure gauge to the high-side line of the system. Or prep ...

  • Hoshizaki KM-900MAF - page 55

    55 10. REMOV AL AND REPLACEMENT OF CONDENSING PRESSURE REGULA T OR (C.P .R.) - REMOTE AIR-COOLED MODEL ONL Y IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply. 2) Remove the panels from the remot ...

  • Hoshizaki KM-900MAF - page 56

    56 1 1. REMOV AL AND REPLACEMENT OF THERMIST OR CAUTION 1. Fragile, handle very carefully. 2. Always use a recommended sealant (High Thermal Conductive Type), Model KE4560RTV manufactured by SHINETSU SILICONE, Part Code 60Y000-11, or Part Code 4A0683-01 equivalent. 3. Always use a recommended foam insulation (Non-absorbent Type) or equivalent. 4. D ...

  • Hoshizaki KM-900MAF - page 57

    57 Min. 4-3/4" Liquid Bypass Flow 10) Secure the insulation using the Plastic Cable Ties. 11) Connect the Thermistor leads through the bushing of the Control Box to the K3 Connector on the Controller Board. Note: Do not cut the leads of the Thermistor while installing it. 12) Replace the Control Box Cover and the panels in their correct positi ...

  • Hoshizaki KM-900MAF - page 58

    58 13. REMOV AL AND REPLACEMENT OF W A TER V AL VE 1) Turn off the power supply. 2) Close the Water Supply Line Shut-off Valve. 3) Remove the Front Panel. 4) Remove the Valve Outlet Tubing by releasing the Clamp. 5) Remove the Bracket from the unit. 6) Remove the Fitting Nut and Water Valve. 7) Disconnect the Terminals from the Water Valve. 8) Inst ...

  • Hoshizaki KM-900MAF - page 59

    59 8) Remove the closed end connectors from the Pump Motor leads. 9) Remove the two screws and the Pump Motor Bracket. 10) Remove the Pump Housing, and check the Impeller. 11) If the Impeller is defective, install a new Impeller. 12) Install the new motor or new parts, and replace the removed parts in the reverse order of which they were removed. 1 ...

  • Hoshizaki KM-900MAF - page 60

    60 VI. MAINTENANCE AND CLEANING INSTRUCTIONS IMPORTANT Ensure all components, fasteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment. 1. PREPARING THE ICEMAKER FOR LONG STORAGE WARNING When shutting off the icemaker for an extended time, drain out all water from the water tank and remove the ice f ...

  • Hoshizaki KM-900MAF - page 61

    61 [2] Remove the water from the potable water supply line: 1) Remove the Front Panel. (Except water-cooled model) 2) Move the Control Switch, on the Control Box, to the “OFF” position. 3) Wait 3 minutes. 4) Close the Potable Water Supply Line Shut-off Valve and open the Potable Water Supply Line Drain Valve. 5) Allow the line to drain by gravi ...

  • Hoshizaki KM-900MAF - page 62

    62 CLOSED POSITION OPEN POSITION 2. CLEANING IMPORTANT Ensure all components, fasteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment. WARNING 1. HOSHIZAKI recommends cleaning this unit at least once a year. More frequent cleaning, however, may be required in some existing water conditions. 2. To p ...

  • Hoshizaki KM-900MAF - page 63

    63 [a] CLEANING PROCEDURE 1) Dilute 16 fl. oz. of the recommended cleaner Hoshizaki “Scale Away” or “LIME-A-WAY” (Economics Laboratory, Inc.) with 3 gallons of water. 2) Remove all ice from the Evaporator and the Storage Bin. Note: To remove cubes on the Evaporator, turn off the power supply and turn it on after 3 minutes. The defrost cycle ...

  • Hoshizaki KM-900MAF - page 64

    64 20) Turn on the power supply to fill the Water Tank with water. 21) Turn off the power supply after 3 minutes. 22) Remove the Front Panel, and fully open the Cleaning Valve. 23) Move the Control Switchto the “Wash” position. 24) Replace the Front Panel in its correct position. 25) Turn on the power supply to rise off the cleaning solution. 2 ...

  • Hoshizaki KM-900MAF - page 65

    65 8) Drain the Water Tank. See the above step 5) in “[a] CLEANING PROCEDURE.” 9) Replace the removed parts and the Insulation Panel in their correct positions. 10) Repeat the above steps 15) through 28) in “[a] CLEANING PROCEDURE” two times to rinse thoroughly. 11) Close the Cleaning Valve. 12) Move the Control Switch to the “ICE” posi ...

Manufacturer Hoshizaki Category Cooktop

Documents that we receive from a manufacturer of a Hoshizaki KM-900MAF can be divided into several groups. They are, among others:
- Hoshizaki technical drawings
- KM-900MAF manuals
- Hoshizaki product data sheets
- information booklets
- or energy labels Hoshizaki KM-900MAF
All of them are important, but the most important information from the point of view of use of the device are in the user manual Hoshizaki KM-900MAF.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Hoshizaki KM-900MAF, service manual, brief instructions and user manuals Hoshizaki KM-900MAF. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Hoshizaki KM-900MAF.

A complete manual for the device Hoshizaki KM-900MAF, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Hoshizaki KM-900MAF by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Hoshizaki KM-900MAF.

A complete Hoshizaki manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Hoshizaki KM-900MAF - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Hoshizaki KM-900MAF, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Hoshizaki KM-900MAF, that we can find in the current document
3. Tips how to use the basic functions of the device Hoshizaki KM-900MAF - which should help us in our first steps of using Hoshizaki KM-900MAF
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Hoshizaki KM-900MAF
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Hoshizaki KM-900MAF in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Hoshizaki KM-900MAF?

Use the form below

If you did not solve your problem by using a manual Hoshizaki KM-900MAF, ask a question using the form below. If a user had a similar problem with Hoshizaki KM-900MAF it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)