Manual Agilent Technologies InfiniiVision 6000 Series

368 pages 1.53 mb
Download

Go to site of 368

Summary
  • Agilent Technologies InfiniiVision 6000 Series - page 1

    Agilent T echnologies Agilent InfiniiV ision 6000 Series Oscilloscopes User’ s Guide ...

  • Agilent Technologies InfiniiVision 6000 Series - page 2

    6000 Series Oscilloscope User’s Guide Notices © Agilent T echnologies, Inc. 2005-2008 N o p a r t o f t h i s m a n u a l m a y b e re p r o d u c e d i n any form or by any means (inc luding elec- tronic storage and retrieval or translation into a foreign language) without prior agree- ment and written consen t from Agilent T echnologies, Inc . ...

  • Agilent Technologies InfiniiVision 6000 Series - page 3

    6000 Series Oscilloscope User’s Guide 3 In This User’ s Guide… This guide shows y ou how to use the A gilent Inf iniiVision 6000 Series oscilloscopes. It cont ains t he f ollo wing chapt ers and top ics: 1G e t t i n g S t a r t e d U npacking and setting up your oscilloscope, using Quick Help. 2 Front-Panel Controls A quick o verview of the ...

  • Agilent Technologies InfiniiVision 6000 Series - page 4

    4 6000 Series Oscilloscope User’s Guide The Agile nt InfiniiVi sion 6000 Series oscillo scopes deliver po werful features and high per f or mance: • 100 MHz, 300 MHz, 500 MHz, and 1 GHz bandwidth models. • U p to 4 GSa /s sa mp le r ate. • P o werful triggering inclu d ing anal og HDT V , I 2 C, SPI, LIN, CA N, a nd US B . • USB, L AN, an ...

  • Agilent Technologies InfiniiVision 6000 Series - page 5

    6000 Series Oscilloscope User’s Guide 5 Ta b l e 1 Model Numbers, Bandwidths, and Sampling Rates Bandwidth 100 MHz 300 MHz 500 MHz 1 GHz Maximum Sample Rate 2 G Sa/s 2 GSa/s 4 GSa/s 4 GSa/s 2-Channel + 16 Logic Channels MSO MSO6012A MSO6032A MSO6 052A MSO6102A 4-Channel + 16 Logic Channels MSO MSO6014A MSO6034A MSO6 054A MSO6104A 2-Channel D SO D ...

  • Agilent Technologies InfiniiVision 6000 Series - page 6

    6 6000 Series Oscilloscope User’s Guide Memor y upg rades can be easily inst alled without re turning t he oscilloscope to a S ervice Center . These upg rades are license d. The foll owing options can be easi ly installed with out returning the osci lloscope to a S ervice Center . These upgrades are licensed. Ta b l e 3 Memory Depth Option Number ...

  • Agilent Technologies InfiniiVision 6000 Series - page 7

    6000 Series Oscilloscope User’s Guide 7 The follo wing option can not be installed af ter time of purchase. Vis it www .agilent.com/find/mso6000 to view the 6000A Series and 6000 L Series data sheets. Ta b l e 5 Order-Only Options Licensed Option Order Battery Operation (Option BA T) Avai la ble at time of purchase. Option can not be added after ...

  • Agilent Technologies InfiniiVision 6000 Series - page 8

    8 6000 Series Oscilloscope User’s Guide Built-in Quick Help A Quick Help system is built into the oscilloscope. Instructions for u sing the quick help system are given on page 58 . Digital Channels Because all of the oscilloscop es in th e Agilent 6000 Seri es have analog channels, the analog channel topics in th is book apply to all i nstruments ...

  • Agilent Technologies InfiniiVision 6000 Series - page 9

    6000 Series Oscilloscope User’s Guide 9 Contents 1 Getting Started 19 T o inspect p ackage contents 22 T o adjust the 6000A Series handle 28 T o mount the oscilloscope in a rack 29 T o mount the 6000A Series oscilloscope in a rack 29 T o mount the 6000L Series oscilloscope in a rack 29 V entilation requirements 32 T o power-on the oscilloscope 33 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 10

    10 6000 Series Oscilloscope User’s Guide Contents Maximum input voltage for analog inputs 52 T o verify basic oscilloscope operation 52 T o compensate the oscilloscope probes 54 T o calibra te the probes 55 Passive Probes Supported 55 Active Probes Supported 56 By 300 MHz, 500 MHz, and 1 GHz Bandwidth Models 56 By 100 MHz Bandwidth Models 57 Usin ...

  • Agilent Technologies InfiniiVision 6000 Series - page 11

    Contents 6000 Series Oscilloscope User’s Guide 11 6000A Series Front-Panel Operation 76 T o adjust the waveform intensity 76 T o adjust the display g rid (graticule) intensity 76 T o start and stop an acquisition 77 T o make a single acquisition 78 T o pan and zoom 79 Choosing Auto trigger mode or Normal trigger mode 80 Using AutoScale 80 T o set ...

  • Agilent Technologies InfiniiVision 6000 Series - page 12

    12 6000 Series Oscilloscope User’s Guide Contents Interpreting the digital waveform display 118 T o switch all digital channels on or off 119 T o switch groups of channels on or off 119 T o switch a single channel on or off 119 T o change the displayed size of the digital channels 120 T o reposition a digital channel 120 T o change the logi c thr ...

  • Agilent Technologies InfiniiVision 6000 Series - page 13

    Contents 6000 Series Oscilloscope User’s Guide 13 T o use Pulse Width triggering 142 < qualifier time set softkey 144 > qualifier time set softkey 144 T o use Pattern triggering 145 Hex Bus Pattern T riggering 147 T o use CAN triggering 148 T o use Duration triggering 152 < qualifier time set softkey 154 > qualifier time set softkey 1 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 14

    14 6000 Series Oscilloscope User’s Guide Contents T o use TV triggering 187 Example exercises 191 T o trigger on a sp ecific line of video 191 T o trigger on all sync pulses 193 T o trigger on a specific field of the video signal 194 T o trigger on all fields of the video signal 195 T o trigger on odd or even fields 196 T o use UART/RS232 trigger ...

  • Agilent Technologies InfiniiVision 6000 Series - page 15

    Contents 6000 Series Oscilloscope User’s Guide 15 Automatic Measurements 239 T o make an automa tic measurement 240 T o set measurement thresholds 241 Tim e M e as ur e me nt s 243 Delay and Phase Measurements 247 V oltage Measurements 249 Overshoot and Preshoot Measurements 255 6 Displaying Data 257 Pan and Zoom 258 T o pan and zoom a waveform 2 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 16

    16 6000 Series Oscilloscope User’s Guide Contents Using Serial Decode 271 To d e c o d e I 2 C data 272 T o decode SPI data 276 T o decode CAN data 281 CAN T otalizer 286 T o decode LIN data 288 T o decode FlexRay data 294 FlexRay T otalizer 298 T o decode UART/RS232 data 300 UART/RS232 T otalizer 306 T o reduce the random noise on a signal 307 H ...

  • Agilent Technologies InfiniiVision 6000 Series - page 17

    Contents 6000 Series Oscilloscope User’s Guide 17 Saving oscilloscope data 320 Selecting a destination for your saved data 321 Selecting a file name 322 W aveform T race and Oscilloscope Setup 324 Display Image and W aveform Data Files 324 Choosing save settings 325 T o save a waveform and/or set up to a USB device 327 T o save a waveform and/or ...

  • Agilent Technologies InfiniiVision 6000 Series - page 18

    18 6000 Series Oscilloscope User’s Guide Contents Digital channel signal fidelity: Probe im pedance and grounding 340 Input Impedance 340 Probe Grounding 342 Best Probing Practices 344 T o replace digital prob e leads 345 Binary Data (.bin) 346 Binary Data in MA TLAB 346 Binary Header Format 346 Example Program for Readi ng Binary Data 350 Exampl ...

  • Agilent Technologies InfiniiVision 6000 Series - page 19

    19 Agilent 6000 Series Oscilloscope User’s Guide  A 1 Getting Started T o inspe c t package contents 22 T o adjust the 6000A Series handle 28 T o mount the oscilloscope in a rack 29 T o power-on the oscilloscope 33 V entilation requirements 32 The remote interface 38 T o establish a LAN connection (6000A Series) 39 T o establish a LAN connecti ...

  • Agilent Technologies InfiniiVision 6000 Series - page 20

    20 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d ✔ V erify basic osci lloscope operation and compensate t he probes. ...

  • Agilent Technologies InfiniiVision 6000 Series - page 21

    Getting Started 1 6000 Series Oscilloscope User’s Guide 21 Built-in Quick Help A Quick Help system is built into the oscilloscope. Instructions for u sing the quick help system are given on page 58 . Digital Channels Because all of the oscilloscop es in th e Agilent 6000 Seri es have analog channels, the analog channel topics in th is book apply ...

  • Agilent Technologies InfiniiVision 6000 Series - page 22

    22 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d T o inspect package contents ✔ Inspect the shipping cont ainer for damage. If y o ur shipping container appe ars to be damaged, keep the shipping cont ainer or cushioning material until you ha ve inspected the cont ents of the shipment f or completeness and ha ve checked the ...

  • Agilent Technologies InfiniiVision 6000 Series - page 23

    Getting Started 1 6000 Series Oscilloscope User’s Guide 23 Figure 1 Package contents for 6000A Seri es AC-powered oscilloscopes Power cord (Part numbers given on page 37 ) *Digital Probe Kit contains: 54620-618 01 16-channel cable ( qty 1) 5959-9334 2-i nch prob e ground leads (qty 5) 5090-4833 Grabbe r (qty 20) Digital pro b e re placement parts ...

  • Agilent Technologies InfiniiVision 6000 Series - page 24

    24 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d Figure 2 Package contents for 6000 A Series batt ery-powered oscilloscopes (Option BA T) AC/DC power adapter Front-panel cover 6000A Series Option BA T Oscilloscope Power cord (see Power Cords table) Oscilloscope probes 10073C or 10074C (Qty 2 or 4) Manuals and CD-ROMs Digital ...

  • Agilent Technologies InfiniiVision 6000 Series - page 25

    Getting Started 1 6000 Series Oscilloscope User’s Guide 25 Figure 3 Package contents for 6000 L Series oscilloscopes 6000L Series Oscilloscope Manuals and CD-ROMs Oscilloscope Probes 10073C or 10074C Qty. 4 Power cord (Part numbe rs given on page 37 ) 50 ohm feedthrough termination ad apter P/N 0960-030 1, Qty. 4 GPIB cable extender P/N 5183-0 80 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 26

    26 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d Ta b l e 6 Accessories availabl e Model Description N2918A 6000 Series Osci l loscope Evaluation Kit 1180CZ T estmobile oscilloscope car t (requires N291 9A adapter ki t) N2919A T estmobile Adapter Kit N2916A 6000A Rackmoun t Kit 54684-44 101 Front-pane l cover N2605A -097 USB ...

  • Agilent Technologies InfiniiVision 6000 Series - page 27

    Getting Started 1 6000 Series Oscilloscope User’s Guide 27 F or information on more probes and accessories see “5989-6162EN Probes and A ccessories Selection Guide” and “5968-8153EN 5000 and 6000 Series Oscilloscope Probes and A ccessories dat a sheet, available at www .agilent.com. N2782A Current probe, 50 MHz, 30 A, AC/DC (use with N2779A ...

  • Agilent Technologies InfiniiVision 6000 Series - page 28

    28 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d T o adjust the 6000A Series handle Y ou can use t he oscilloscope’s handle f or car r ying the instr ument, or y ou can use it as a stand to tilt t he instrument up f o r easier viewin g of its displa y. 1 Grasp t he handle hubs on each side of the instr ument and pull the hu ...

  • Agilent Technologies InfiniiVision 6000 Series - page 29

    Getting Started 1 6000 Series Oscilloscope User’s Guide 29 T o mount the oscilloscope in a rack The InfiniiVision 6000 Series osci lloscopes can be mounted into Electronic Industries As sociation (EIA) standard 19-inc h (487-mm) rack cabine ts. T o mount the 6000A Series oscilloscope in a rack Purchase and install the N2916A rack mount kit. Instr ...

  • Agilent Technologies InfiniiVision 6000 Series - page 30

    30 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d 1 Lo osel y at tach the Fron t Exte nde r Supp orts to the Rea r Extender Supports wit h f our (4) clip-nuts and four (4) of the 10-32 x 0.375 Rail Screws. (The scre ws require a Torx T20 driver .) Choose t he correct set of slots in t he supports such that t heir o verall leng ...

  • Agilent Technologies InfiniiVision 6000 Series - page 31

    Getting Started 1 6000 Series Oscilloscope User’s Guide 31 2 Fasten t he Rack Mount Extenders to t he oscilloscope chassis with t he f our (4) M3 x 6 mm screws, using a T or x T10 driver as f ollows: a Attach a Rack Mount Ext ender to t he left side of t he oscilloscope using tw o (2) of t he M3 x 6 mm screws in the inner set of holes on t he Rac ...

  • Agilent Technologies InfiniiVision 6000 Series - page 32

    32 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d Extenders to t he rack usi ng t he f our (4) remaining 10-32 x 0.375 Rail Screws. Use the T or x T20 driver . 5 Se cure ly attac h the R ear Exten der Supp orts to the Fr ont Extender Suppor ts by tightening the four (4) 10-32 x 0.375 Rail Screws scre ws t hat y ou loosely att ...

  • Agilent Technologies InfiniiVision 6000 Series - page 33

    Getting Started 1 6000 Series Oscilloscope User’s Guide 33 T o power-on the oscilloscope AC-Powered 6000 Series 1 Co nnec t the p o we r cor d to the re ar of the os cill osc ope, then to a suit able A C voltage source. The oscilloscope automatically adjusts f or input line voltages in the range 100 to 240 V A C. Ensure that you ha ve the corr ec ...

  • Agilent Technologies InfiniiVision 6000 Series - page 34

    34 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d The 6000A Series Option BA T oscilloscopes are batter y po wered. They have additional LED indicators on t he front panel: Batter y life is appr oximatel y 1.75 hours, depending on the oscilloscope configuration . Operating with the Internal Battery When operating wit h the int ...

  • Agilent Technologies InfiniiVision 6000 Series - page 35

    Getting Started 1 6000 Series Oscilloscope User’s Guide 35 3 Press the pow er switch. The po wer switch is located on t he lo wer left corner of t he front panel. Some front panel lights will come on and the oscilloscope will be operational in a fe w seconds. Figure 5 Ground post on rear panel Ground Post ...

  • Agilent Technologies InfiniiVision 6000 Series - page 36

    36 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d Charging the Battery When charging the batter y , t he operating tem perature should be in the rang e from 0 ° C to 45 ° C, ≤ 80% relativ e humidity. 1 Co nnec t the s uppl ied A C ad apter to the b ack of the oscilloscope, and connect the adapter’s po wer cord to a suita ...

  • Agilent Technologies InfiniiVision 6000 Series - page 37

    Getting Started 1 6000 Series Oscilloscope User’s Guide 37 Ta b l e 8 Power Cords Plug T ype Cable Part Number Plug T ype Cable Part Number Opt 900 (U.K .) 8121-1579 Opt 918 (Japan ) 8121-16 03 Opt 901 (Austral ia) 8121 -1581 Opt 919 (Israel) 8121-166 2 Opt 902 (E urope) 8121-15 80 Opt 920 (Argen tina) 8121-1599 Opt 903 (U. S.A.) 8121-160 9 Opt 9 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 38

    38 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d The remote interface Y ou can communicat e with all Infi niiVision 6000 Series oscilloscopes via L AN, US B, or GPIB. 6000A Series oscilloscopes can also be controlled using the front panel k eys. The 6000L Series oscilloscopes do not hav e a ke yboard or displa y , so communic ...

  • Agilent Technologies InfiniiVision 6000 Series - page 39

    Getting Started 1 6000 Series Oscilloscope User’s Guide 39 T o establish a LAN conne ction (6000A Series) 1 If the controller PC isn’t already connected to t he local area netw ork (L AN), do t hat first. 2 Get the oscilloscope’s netw ork parameters (hostname, domain, IP address, subnet mask, gateway IP , DNS IP , et c.) from y our network ad ...

  • Agilent Technologies InfiniiVision 6000 Series - page 40

    40 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d T o establish a LAN connection (6000L Series) 1 Connect a cable from your site Local Area Netw ork (L AN) t o the LAN port on the re ar p anel of the osc illo scop e. 2 Switc h on the oscillo scope po wer . When t he L AN indicator illuminates g reen, the L AN is connected as c ...

  • Agilent Technologies InfiniiVision 6000 Series - page 41

    Getting Started 1 6000 Series Oscilloscope User’s Guide 41 F or mor e inf or mation about connecti ng to t he oscilloscope, refer to the A gilent Technologies US B/LAN/GPIB Interfaces Connectivity Guide . F or a print able electronic copy of the Connectivity Guide, dire ct y our W eb bro wser t o www .agilent.com and search f or Connectivity Guid ...

  • Agilent Technologies InfiniiVision 6000 Series - page 42

    42 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d T o establish a point-to-point L AN connection Stand-alone connection to a PC The follo wi ng pr oc edure describes how to est ablish a point-to-point (st and alone) conne ct ion to the os cil los cope . Thi s is useful if y o u want to control the oscilloscope using a lapt op ...

  • Agilent Technologies InfiniiVision 6000 Series - page 43

    Getting Started 1 6000 Series Oscilloscope User’s Guide 43 11 When the instr ument is f ound, select OK and OK to clos e the A dd Ins trument windo ws. No w t he instrument is connect ed and the instrument’s W eb inter face may be used. T o use the W eb interface All Inf iniiVision 6000 Series oscilloscopes include a built-in W eb server (requi ...

  • Agilent Technologies InfiniiVision 6000 Series - page 44

    44 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d Controlling the oscilloscop e using a W eb browser A built-in W eb server allo ws c ommunication and control via a Ja va™ -enabled W eb bro w ser . Measurements can be set up, wa veforms can be monitored, sc reen images c an be captured, and the osc illoscope can be operated ...

  • Agilent Technologies InfiniiVision 6000 Series - page 45

    Getting Started 1 6000 Series Oscilloscope User’s Guide 45 possible to use a point-to-point connection (see page 42 ), but using a LAN is t he pref erred met hod. 2 T ype the oscilloscope’s hostname or IP address i n the we b bro wser . 3 When the oscilloscope’s W eb page is dis pla yed, select Browser W eb Control , then sele ct Remote Front ...

  • Agilent Technologies InfiniiVision 6000 Series - page 46

    46 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d Setting a password Whenever y ou connect t he oscilloscope t o a L AN, it is good pr acti ce to set a pass w ord to pr ev ent una uthori zed acc ess to the oscilloscope via W eb bro wser . 1 Select th e Configure Network tab from the instr ument’s We l c o m e p a g e . Step ...

  • Agilent Technologies InfiniiVision 6000 Series - page 47

    Getting Started 1 6000 Series Oscilloscope User’s Guide 47 2 Select the Mo dify Configu ration button. 3 Enter your desired passw ord, and click Apply Changes . 4 T o reset t he passw ord: • 6000A Series oscillo scopes - Press Utility & I/O & LAN Reset . • 6000L Series oscillos copes - Press the LAN RESET butt on on the front panel. S ...

  • Agilent Technologies InfiniiVision 6000 Series - page 48

    48 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d Function Keys Softkeys Hint appears when you roll over with mouse Main Menu (Left-click to select, Right- click for Quick Help ...

  • Agilent Technologies InfiniiVision 6000 Series - page 49

    Getting Started 1 6000 Series Oscilloscope User’s Guide 49 Scrolling and Monitor Resolution When using a monitor resolution of 1024 x 7 68 or less on t he re mote c om puter , y ou n eed to scr oll to ac cess the fu ll r emote front panel. T o display the re mote front panel without scroll bars, use a monitor resolution g reater than 1024 x 7 68 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 50

    50 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d Printing the oscilloscope’ s display from a web browser T o print t he oscilloscope’s displa y from a web br owser: 1 Est ablish a connection to t he oscillosco pe as described in thi s cha pter a nd go to the osci llos cope ’s W elc ome page . 2 Select the Get Image tab ...

  • Agilent Technologies InfiniiVision 6000 Series - page 51

    Getting Started 1 6000 Series Oscilloscope User’s Guide 51 T o connect the oscilloscope probes The analog input im pedance of t he 100 MHz oscilloscopes is fix ed at 1 M Ω . The 1 M Ω mode is for use with man y pass iv e probes and f or general purpose measurements. The high impedance minimizes t he loading effect of the oscilloscope on the c ...

  • Agilent Technologies InfiniiVision 6000 Series - page 52

    52 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d T o verify basic oscilloscope operation If y ou have a 6000L Series oscilloscope, y ou will need to st art a W eb control session, as described on page 44 . 1 Press the Save/Recall ke y on t he front panel, the n press the Default Setup sof tk ey. (The softkeys are located dire ...

  • Agilent Technologies InfiniiVision 6000 Series - page 53

    Getting Started 1 6000 Series Oscilloscope User’s Guide 53 5 Y ou should see a wave form on t he oscilloscope’s display similar to t his: If y o u see the wave form, but t he square wav e is not s haped correctly as sho wn abov e, per f or m the procedure “T o compensate t he oscilloscope probes” on page 54. If y ou d o not see the wav efor ...

  • Agilent Technologies InfiniiVision 6000 Series - page 54

    54 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d T o compensate the oscilloscope probes Y ou s houl d com pens ate y our osci llos cop e pr obes to match their characterist ics to the o scilloscope’s channels. A poorly compensated probe can introduce measurem ent errors. 1 P er form the procedure “T o verif y basic oscill ...

  • Agilent Technologies InfiniiVision 6000 Series - page 55

    Getting Started 1 6000 Series Oscilloscope User’s Guide 55 T o calibrate the probes The oscilloscope can accurately calibrate its analog oscilloscope channels to cer t ain activ e probes, such as InfiniiMax probes. Other probes, such as the 10073C and 1007 4C passive probes, do not require calibration. The Calibrat e Probe softke y will be gray e ...

  • Agilent Technologies InfiniiVision 6000 Series - page 56

    56 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d Active Probes Supported By 300 MHz, 500 MHz, and 1 GHz Bandwidth Models A ctive probes that do not have their o wn ext ernal po wer suppl y re quir e su bstant ial p o we r fr om th e A utoPr ob e inte r fa ce. (The A u toProbe interface is present on t he 300 MHz, 500 MHz, and ...

  • Agilent Technologies InfiniiVision 6000 Series - page 57

    Getting Started 1 6000 Series Oscilloscope User’s Guide 57 By 100 MHz Bandwidth Models The foll owing activ e probes use their own po wer supply. Theref ore, t hey can be used on all 6000 Series oscilloscopes, including the 100 MHz bandwidt h models. Ma ny a c ti ve p rob e s h ave a 50 Ω output im pedance. The input impedance of 6000 Series 10 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 58

    58 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d Using Quick Help T o view Quick Help on 6000L Series oscilloscopes: Star t a W eb bro wser control session as described on page 44 and select Remote F ront P anel. To vie w Qu ick Help inf or mation, right-click on the softkey. Hel p is not available f or front panel key s; on ...

  • Agilent Technologies InfiniiVision 6000 Series - page 59

    Getting Started 1 6000 Series Oscilloscope User’s Guide 59 Quick Help Languages At the time this manual was published, Quick Help was a vai lable in Eng lish, Simplified Chinese, Japanes e, German, Fre nch , a nd R uss ian . T o choose a Quick Help language in t he oscilloscope: 1 Press Utility , t hen press the Language sof tke y. 2 Repeatedly p ...

  • Agilent Technologies InfiniiVision 6000 Series - page 60

    60 6000 Series Oscilloscope User’s Guide 1G e t t i n g S t a r t e d ...

  • Agilent Technologies InfiniiVision 6000 Series - page 61

    61 Agilent T echnologies Agilent 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls 6000L Series Oscilloscope Controls 62 6000A Series Oscillosco pe F ront-Panel Controls 66 6000A Series Front-Panel Operation 76 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 62

    62 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls 6000L Series Oscilloscope Controls The 6000L Series oscilloscope is designed to be remot el y controlled. Theref ore the front panel la yout is sim ple. Front Panel Rear Panel 5 Intensity Control 1 Power Switch 2 Power Indicator 3 LAN Status Indicator 6 USB Port 7 Probe Comp Terminal ...

  • Agilent Technologies InfiniiVision 6000 Series - page 63

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 63 Front and Rear Panel Controls and Connectors 1. Power Switch Press once to swit ch po wer on; press again to switch pow er of f. See page 33 . 2. Power Indicator Illuminates g reen when po wer is on. 3. LAN Status Indicator This indicator illumin ates gree n when a L AN connection ha ...

  • Agilent Technologies InfiniiVision 6000 Series - page 64

    64 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls 7. Probe Compensation T erminals Use the signal at th ese termi nal s to ma tch ea ch pr ob e’s c hara cter isti cs to the oscilloscope channel t o which it is connecte d. See page 54 . 8. AutoProbe Interface (Not availabl e on 100 MHz bandwidt h models.) When you connect a probe t ...

  • Agilent Technologies InfiniiVision 6000 Series - page 65

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 65 15. Digital Channels Input If you pur chased t he MSO upgrade you can vie w and trigger on digit al signals. See page 111 . 16. USB Host Port Connect a USB compliant mass storage device to store or recall oscilloscope setup files o r wa vef or ms. Y ou c an a lso u se the USB p ort t ...

  • Agilent Technologies InfiniiVision 6000 Series - page 66

    66 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls 6000A Series Oscilloscope Front-Panel Controls This is an introduction to the front-panel contr ols of t he Agilent 6000A Series oscilloscope. Generally , yo u set up t he front-panel controls and then mak e a measurement. The ke ys on t he fr on t panel bring up softkey menus on the ...

  • Agilent Technologies InfiniiVision 6000 Series - page 67

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 67 Conventions Throughout this book, the front-panel k eys and softkeys are denoted by a change in f ont. F or example, the Cursors key is in the Measure section of t he fr ont panel. The Acq Mode so ftkey is the left -mos t so ftk ey whe n the Ac qui re m enu i s di spl a ye d. In this ...

  • Agilent Technologies InfiniiVision 6000 Series - page 68

    68 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls 4-Channel 6000A Series Os cilloscope Front Panel The fo llowing diagram sho ws the front panel of the 6000A Series 4-channel oscilloscopes. The controls of the 2-channel oscilloscopes are very simila r . For a diag ram sho wing the differences of the 2-ch annel oscilloscope, see page ...

  • Agilent Technologies InfiniiVision 6000 Series - page 69

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 69 Front Panel Controls 1. Power Switch Press once to swit ch po wer on; press again to switch pow er of f. See page 33 . 2. Intensity Control Rota te clo ckwi se to i ncr ease anal og wa vef orm in tensi ty; coun terc loc kwis e to de crea se. Y o u can v ar y the int ensity control to ...

  • Agilent Technologies InfiniiVision 6000 Series - page 70

    70 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls 6. V ertical Position Control Use this k nob to cha nge th e channel’s vertical position on t he displa y. Ther e is one V er tical P osition control f or each channel. See “Using t he analog channels” on page 83. 7. Channel On/Off Key Use th is k e y to sw itch th e cha nnel o ...

  • Agilent Technologies InfiniiVision 6000 Series - page 71

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 71 14. Utility Key Press th is k ey to access t he Utility menu, which lets you configure the oscillosco pe’s I/O settings, printer configuration, f ile explorer , service menu, and ot her options. 15. T rigger Controls These controls determine ho w t he oscilloscope triggers t o capt ...

  • Agilent Technologies InfiniiVision 6000 Series - page 72

    72 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls Run mode) then you are looking at the wav eform dat a from the last acquisition t ak en. See “T o set up the Horizont al time base” on page 88. 19. Horizontal Menu/Zoom Key (Labeled Main/Delayed on older models.) Press this ke y t o access the menu where you can split the osci ll ...

  • Agilent Technologies InfiniiVision 6000 Series - page 73

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 73 24. AutoScale Key When y ou press t he A ut oScale k ey the oscilloscope will quickly dete rmine which channels ha ve activity , and it will tur n these channels on and scale them t o display the in put sign als. See “Ho w AutoScale W orks” on page 312 25. Softkeys The functions ...

  • Agilent Technologies InfiniiVision 6000 Series - page 74

    74 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls 2-Channel 6000A Series Oscilloscope Front Panel (differences only) Figure 7 6000A Series 2-Channel Os cillosc ope Front Panel The differences betw een t he front panel of the 4-channel oscilloscopes and the 2-channel oscilloscopes are: • The 2-channel oscilloscope has tw o sets of ...

  • Agilent Technologies InfiniiVision 6000 Series - page 75

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 75 Interpreting the display The oscilloscope display contains acquired wav eforms, setup information, measurement results, and softkeys f o r setting up parameters. Figure 8 Interpreting the display Status line The top line of t he displa y contains ver tical, horizont al, and trigger s ...

  • Agilent Technologies InfiniiVision 6000 Series - page 76

    76 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls 6000A Series Front-Panel Operation This section provides a brie f overview of operating the front-panel controls. Detail ed oscilloscope operating instructions are provided in later chapters. T o adjust the waveform intensity The Intensity control is at the lo wer left cor ner of the ...

  • Agilent Technologies InfiniiVision 6000 Series - page 77

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 77 T o start and stop an acquisition • When y ou press t he Run/Stop ke y , it illuminates in g reen and the oscilloscope is in continuous r unning mode. The oscilloscope examines the in put voltage at each pr obe, and updates t he displa y whenev er t he trigger condi tions are met. ...

  • Agilent Technologies InfiniiVision 6000 Series - page 78

    78 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls T o make a single acquisition When y ou press t he Single k ey it illuminates in yello w and t he oscilloscope st arts t he acquisition system, searching f or t he trigger condition. When t he tr igger condition is met, t he captured wav eform is display ed, th e Single k ey is extin ...

  • Agilent Technologies InfiniiVision 6000 Series - page 79

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 79 2 If y ou are triggering on anal og channel e vents, turn t he Trig ger Lev el kn ob to the tri gger thres hol d to a l ev el th at y our wa veform will cr oss. 3 T o begin a sing le acquisition, press t he Single key . When y ou press Sing le , the displa y is cleared, the trigger c ...

  • Agilent Technologies InfiniiVision 6000 Series - page 80

    80 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls 3 Tu rn the Horizont al P osition knob () to pan horizont ally and turn t he channel’s v er tical position knob ( ) t o pan ver t ic al ly. The stopped display ma y cont ain sev eral triggers wort h of information, but only the last trigger acquisition is a vailable for pan and zoo ...

  • Agilent Technologies InfiniiVision 6000 Series - page 81

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 81 T o make t he oscilloscope remai n in t he acquisiti o n mode y ou ha ve chosen, press t he AutoScale Acq Mode sof tke y and select Preserve Acquisition Mode . Ot her wise, the acquis ition mode will default to Normal whenever the AutoScale key is pressed. Example Connect the oscillo ...

  • Agilent Technologies InfiniiVision 6000 Series - page 82

    82 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls around the oscilloscope’s B N C connec tor . Therefore, the oscilloscope will automatically set the att enuation factor for recognized Agilent passive pr obes. Passiv e probes that do not have a pin that connects to the ring around the BNC connector will not be recognized by the os ...

  • Agilent Technologies InfiniiVision 6000 Series - page 83

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 83 Using the analog channels Connect the oscilloscope prob es for channels 1 and 2 to the Probe Com p output on t he front panel of the instr ument. 1 Press the 1 ke y in the Analog section of t he oscilloscope’s front panel to display the Channel 1 menu. Pressing an analog channel k ...

  • Agilent Technologies InfiniiVision 6000 Series - page 84

    84 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls V ertical sensitivity Tur n the large knob abo ve the channel key to set t he sensitivity (v olts/division) for the channel. The vertical sensiti vity knob changes t he analog channel sensitivity in a 1-2-5 step sequence (wit h a 1:1 pr obe att ached). The analog channel V olts/Div v ...

  • Agilent Technologies InfiniiVision 6000 Series - page 85

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 85 2 Press the channel’s on/of f ke y , t hen press the Coupling sof tk ey to select t he input channel coupling. Coupling changes t he channel' s input coupling to either AC (alternating cur rent) or DC (direct current) . A C coupling places a 3.5 Hz high-pass filter in series w ...

  • Agilent Technologies InfiniiVision 6000 Series - page 86

    86 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls • 50 Ohm mode mat ches 50-ohm cables commonly used in making high frequency meas urements, and 50-ohm active probes. This im pedance matching gives y ou the most accurate measurements sinc e ref lections are minimiz ed along the signal pat h. When 50 Ohm is selected, “50 Ω ” ...

  • Agilent Technologies InfiniiVision 6000 Series - page 87

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 87 6 Press the Pro be softke y t o displa y t he channel pr obe menu. This menu lets you select additional pr obe parameters s uch as attenuation factor and units of measurement for the connect ed pr ob e. • Probe Units — Press the Units sof tke y to select t he proper measurement u ...

  • Agilent Technologies InfiniiVision 6000 Series - page 88

    88 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls • Calibrate Probe — See “T o calibrat e the probes” on page 55. T o set up the Horizontal time base 1 Press the Menu/Zoom ke y (lab eled Main/Delayed on older models) in t he Horizont al section of the front panel. T o manually control t he horizont al time base on 6000L mode ...

  • Agilent Technologies InfiniiVision 6000 Series - page 89

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 89 2 Tu rn t he large knob (time/ division) in the H orizont al section and notice the change it mak e s to the st atus line. When the oscilloscope is running in Main mode, use the large Horizontal knob t o change sweep speed and use t he small kn ob ( ) to set th e hor izo ntal positio ...

  • Agilent Technologies InfiniiVision 6000 Series - page 90

    90 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls • Wh en the h ori zonta l mod e is s et to M ain , the h oriz ontal position knob positions th e main sw eep relative to t he trigger . This delay is a fixed number . Changing t his dela y value does not affect the sw eep speed. • When the horizo ntal mode is set to Zoom, t he ho ...

  • Agilent Technologies InfiniiVision 6000 Series - page 91

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 91 Zoom mode Zoom sweep is an expanded version of main sweep. When Zoom mode is selected, t he display divides in half and the Zoom s wee p i c o n di s pl ay s in t h e m id d l e o f t h e l i n e a t t h e t op o f t h e displa y. The top half of the display sho ws the main sweep and ...

  • Agilent Technologies InfiniiVision 6000 Series - page 92

    92 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls The area of the m ain display that is expanded is intensi fied and marked on each end with a v er tical marker . These markers sho w what por tion of the ma in sw eep is expand ed in the low er half. The Horizont al knobs control the size and position of t he Zoom sw e ep. The delay ...

  • Agilent Technologies InfiniiVision 6000 Series - page 93

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 93 T o change t he sweep speed f or t he Zoom sweep windo w , tur n the sweep speed knob. As you turn the knob, t he sweep speed is highlighted in the status line abov e the wav eform displa y area. The time refe rence position sets t he initial position of the trigger event within acqu ...

  • Agilent Technologies InfiniiVision 6000 Series - page 94

    94 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls • In Roll mode there is no trigger . The fixed ref erence point on the screen is t he right edge of the screen and refers to th e current moment in time. E v ents t hat ha ve occur red are scrolled to the lef t of t he ref erence point. Since t here is no trigger , no pre -trigger ...

  • Agilent Technologies InfiniiVision 6000 Series - page 95

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 95 T o make cursor measurements Y ou can use the cursors to make custom v olt age or time measurements on osc illosc ope signals, and timing measurements on digit al channels. • T o manually control Cursors on 6000L models st ar t the Remote F r ont Panel (see page 44 ) and select Mea ...

  • Agilent Technologies InfiniiVision 6000 Series - page 96

    96 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls T o make automatic measurements Y ou can use aut omatic measurements on any channel sour ce or an y r unning math function. Cursors are tur ned on to focus on the most recently selected me asurement (right-most on t he measurement line above the sof tk eys on the displa y). 1 Press t ...

  • Agilent Technologies InfiniiVision 6000 Series - page 97

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 97 Using Labels Y ou can def ine labels and assign them t o each analog in put channel, or you can turn labels off t o increase the wavef or m displa y area. Labels can also be applied t o digital channels on MSO models. T o turn the label display on or off 1 Press the Label ke y on t h ...

  • Agilent Technologies InfiniiVision 6000 Series - page 98

    98 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls T o assign a predefined label to a channel 1 Press the Label ke y. 2 Press the Channel sof tk ey , t hen turn the Entr y knob or successivel y press t he Channel softkey to select a channel f o r label assignment. The f igure abo ve sho w s the list of chan nels and their def ault la ...

  • Agilent Technologies InfiniiVision 6000 Series - page 99

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 99 T o define a new label 1 Press the Label ke y. 2 Press the Channel sof tk ey , t hen turn the Entr y knob or successivel y press t he softke y t o select a channel f o r label assignment. The channel does not hav e to be tur ned on to hav e a label as sign ed to i t. I f the c hann e ...

  • Agilent Technologies InfiniiVision 6000 Series - page 100

    100 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls T o load a list of labels f rom a text file you create It may be conv en ient to creat e a list of labels using a text edit or , then loa d the l abel lis t into the os cill osc ope. Thi s let s y ou t ype on a ke yboard rather t han edit the label list using t he oscilloscope’s c ...

  • Agilent Technologies InfiniiVision 6000 Series - page 101

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 101 T o reset the label library to the factory default 1 Press Utility & Options & Preferences . 2 Press the Defau lt Librar y softke y. This will delete all user- def ined labels from the librar y and set the labe ls in the librar y back t o the fa ctor y default. Ho wev er , t ...

  • Agilent Technologies InfiniiVision 6000 Series - page 102

    102 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls T o set the clock The Clock menu lets you set the current date and time of da y (24-hour f or mat). This time/dat e stamp will appear on har dcopy prints and director y information on the USB mass st orage device. T o set the da te and tim e, or to vie w the c urren t date and t ime ...

  • Agilent Technologies InfiniiVision 6000 Series - page 103

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 103 T o set up the screen saver The oscilloscope can be configured to turn on a display screen sa ver when the oscill oscope has be en idle for a specified lengt h of time. 1 Press Utility & Options & Preferences & Screen Saver to d isp la y the screen sav er menu. 2 Press t ...

  • Agilent Technologies InfiniiVision 6000 Series - page 104

    104 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls 3 Tu rn the Entr y knob t o select the number of minutes t o wait bef o re the selected screen s a ver activates. When y ou tur n the Entr y knob, t he number of minutes is display ed in t he Wa i t sof tk ey. The default time is 180 min utes (3 hours) . 4 Press the Previe w softke ...

  • Agilent Technologies InfiniiVision 6000 Series - page 105

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 105 T o perform service functions • Press the Utility & Service to display the service menu. The Service Menu lets y ou: • P er f orm User Cal on the oscillosc ope. • View User Cal status. • P er form instr ument Self T est. • Vie w information abo ut your osc illoscope mo ...

  • Agilent Technologies InfiniiVision 6000 Series - page 106

    106 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls P er forming User Cal will invalidate your Certificat e of Calibration. If NIST (National Institute of Standards and T echnology) traceability is required, per form the Performance V erification procedure in the Agilent InfiniiV ision 6000 Series Oscilloscopes Service Guide using tr ...

  • Agilent Technologies InfiniiVision 6000 Series - page 107

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 107 F or a 4-channel oscilloscope, connect BNC tees to t he equal-length cables as shown belo w . Then connect a BNC(f)-to-BNC(f) (barrel connector ) to the t ee as sho wn belo w . Figure 11 User Cal ibration cable for 4-channel os cilloscope 1 Connect a BN C cable (40 inches maximum) f ...

  • Agilent Technologies InfiniiVision 6000 Series - page 108

    108 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls probes do not need to be calibrated, but Inf iniiMax pr obes can be calibrat ed. F or more information ab out calibrating probes see page 55 . Results: User Cal date: Change in temperature since last User Cal: Failure: Comments: Probe Cal Status: Self T est Pressing Utility & Se ...

  • Agilent Technologies InfiniiVision 6000 Series - page 109

    Front-Panel Controls 2 6000 Series Oscilloscope User’s Guide 109 Installed licenses: This line in the About This Oscilloscope dialog cont ains information about the licenses t hat ha ve been installed on t he oscilloscope. F or example, it can sho w: • 232 — U ART (Univ ersal Asynchronous Receiver/Transmitter) and RS232 (Recommended Standa rd ...

  • Agilent Technologies InfiniiVision 6000 Series - page 110

    110 6000 Series Oscilloscope User’s Guide 2 Front-Panel Controls T o restore the oscilloscope to its default configuration • Press the Save/Recall ke y , then press t he Default Setup softke y. The default conf iguration returns th e oscilloscope t o its defau lt settings. This places t he oscilloscope in a kno wn oper ating condition. The majo ...

  • Agilent Technologies InfiniiVision 6000 Series - page 111

    111 Agilent T echnologies Agilent 6000 Series Oscilloscope User’s Guide 3 V iewing and Measuring Digital Signals T o connect the digital probes to the circuit under test 112 Acquiring waveforms usin g the digital channels 115 T o display digital channel s using AutoScale 116 Interpr eting the digital wave form display 118 T o switch a ll digital ...

  • Agilent Technologies InfiniiVision 6000 Series - page 112

    112 6000 Series Oscilloscope User’s Guide 3 Viewing and Measuring Digital Signals T o connect the digital probes to the circuit under test The digit al channels are enabled on MSO6000 models and DSO6000 models which ha ve the MSO upg rade license installed. 1 If y ou feel it’s necessar y , turn of f the po wer suppl y t o the circuit under test ...

  • Agilent Technologies InfiniiVision 6000 Series - page 113

    Viewing and Measuring Digital Signals 3 6000 Series Oscilloscope User’s Guide 113 the osci lloscope. Snap t he wide end of t he cable guide in place, being carefu l no t to pinch the cable. 4 Connect the g round lead on each set of channels (each pod), using a probe grabber . The ground lead impro ves signal fideli ty to t he oscilloscope, ensuri ...

  • Agilent Technologies InfiniiVision 6000 Series - page 114

    114 6000 Series Oscilloscope User’s Guide 3 Viewing and Measuring Digital Signals 6 Connect the g rabber to a node in the circuit you want to test. 7 F or high-spe ed signals, connect a g round lead to th e pr ob e lead, connect a grabber t o the g r ound lead, and att ach the gra bbe r to gr oun d in th e ci rc uit unde r tes t. Signal Lead Grou ...

  • Agilent Technologies InfiniiVision 6000 Series - page 115

    Viewing and Measuring Digital Signals 3 6000 Series Oscilloscope User’s Guide 115 8 Repeat steps 3 t hr ough 6 until you ha ve conn ected all poin ts of interest. Acquiring waveforms using the digital channels When you press Run/Stop or Si ngle t o run the oscilloscope, t he oscilloscope examines t he input v olt age at each input pr o be. When t ...

  • Agilent Technologies InfiniiVision 6000 Series - page 116

    116 6000 Series Oscilloscope User’s Guide 3 Viewing and Measuring Digital Signals T o display digital channels using AutoScale When signals are connected to the digit al channels, A ut oScale quickly configures and disp la ys t he digital channels. • T o conf igure t he instrume nt quickly , press the AutoScale ke y. An y digit al channel with ...

  • Agilent Technologies InfiniiVision 6000 Series - page 117

    Viewing and Measuring Digital Signals 3 6000 Series Oscilloscope User’s Guide 117 configuration by pressing t he Save/Recall k ey , then th e Default Setup sof tk ey. Then press t he AutoSca le key. Y ou should see a displa y similar t o the follo wing. Figure 12 AutoScale of digital channels 0 & 1 (MSO model s only) ...

  • Agilent Technologies InfiniiVision 6000 Series - page 118

    118 6000 Series Oscilloscope User’s Guide 3 Viewing and Measuring Digital Signals Interpreting the digital waveform display The foll owing figure sho ws a typical display with digital channels. Activity indicator When an y digit al channels are turn ed on, an activity indicator is displa yed in t he status line at t he bottom of the display. A di ...

  • Agilent Technologies InfiniiVision 6000 Series - page 119

    Viewing and Measuring Digital Signals 3 6000 Series Oscilloscope User’s Guide 119 T o switch all digital channels on or off 1 Press the D15 T hru D0 ke y t o switch the display of the digital channels on or off. The Digit al Channel Menu will be display ed abov e t he softkeys. On 6000L models select Digital from the main menu or press ctrl+D. Th ...

  • Agilent Technologies InfiniiVision 6000 Series - page 120

    120 6000 Series Oscilloscope User’s Guide 3 Viewing and Measuring Digital Signals T o change the displayed size of the digital channels 1 Press the D15 T hru D0 key . 2 Press the size ( ) sof tk ey to select ho w t he digital channels are displa yed. The sizing control lets y ou spre ad out or compress t he digit al traces v er tically on the dis ...

  • Agilent Technologies InfiniiVision 6000 Series - page 121

    Viewing and Measuring Digital Signals 3 6000 Series Oscilloscope User’s Guide 121 function changes depending on which menu is display ed. F or examp le, when assigning Labels on digital channels the Entr y knob selects th e channel to which t he Label will be applied. T o change the logic threshold for digital channels 1 Press the D15 T hru D0 k ...

  • Agilent Technologies InfiniiVision 6000 Series - page 122

    122 6000 Series Oscilloscope User’s Guide 3 Viewing and Measuring Digital Signals T o display digital channels as a bus Digit al channels ma y be grouped and displa yed as a bus, with each bus value display ed at t he bottom of th e displa y in hex or binar y. Y ou can create up t o tw o busses. T o conf igure and displa y each bus, press t he D1 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 123

    Viewing and Measuring Digital Signals 3 6000 Series Oscilloscope User’s Guide 123 The buses are sho w n at the bott om of t he display. Using cursors to read bu s values T o read the digit al bus value at any point using the cursors: 1 Switch on Cursors (b y pressing the Cursor k ey on the front panel) 2 Press the cur sor Mode softke y and change ...

  • Agilent Technologies InfiniiVision 6000 Series - page 124

    124 6000 Series Oscilloscope User’s Guide 3 Viewing and Measuring Digital Signals 4 Use the Entr y knob and t he X1 and X2 sof tk eys to positio n the cursors where y ou wan t to read the bus values. When y ou press t he D15 Thru D0 k ey t o displa y t he Digit al Channel Menu, the digit al activity indicator is shown where the cursor values were ...

  • Agilent Technologies InfiniiVision 6000 Series - page 125

    Viewing and Measuring Digital Signals 3 6000 Series Oscilloscope User’s Guide 125 Bus values are displayed when using Pattern trigger The bus values are also displa yed when using t he Pattern trigger function. Press the Pattern key on the front panel t o display the Pattern Trigger Menu and the bus values will be displa yed on the right, abo ve ...

  • Agilent Technologies InfiniiVision 6000 Series - page 126

    126 6000 Series Oscilloscope User’s Guide 3 Viewing and Measuring Digital Signals ...

  • Agilent Technologies InfiniiVision 6000 Series - page 127

    127 Agilent T echnologies Agilent 6000 Series Oscilloscope User’s Guide 4 T riggering the Oscilloscope Selecting T rigger Modes and Conditions 130 The External T rigger input 136 T rigger T ypes 139 T o use Edge triggering 140 T o use Pulse Width triggering 142 T o use Pattern triggering 145 T o use CAN triggering 14 8 T o use Duration triggering ...

  • Agilent Technologies InfiniiVision 6000 Series - page 128

    128 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope The Agilent In finiiVis ion 6000 Series oscill oscopes pro v ide a full se t of f eatu res to hel p auto mate yo ur me asur eme nt tasks. MegaZoom technology lets y ou capture and examine untriggered wav eforms. Wit h these oscilloscopes you can: • Modify the way the oscill ...

  • Agilent Technologies InfiniiVision 6000 Series - page 129

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 129 • Trigger Out connect or T o manually control T riggering on 6000L models st art t he Remote F r ont Panel (see page 44 ) and select T rigger from the Main Menu. NOTE Adding options such as the Low Speed Serial (LSS) or Automoti ve Serial (AMS) serial decode feature to the ...

  • Agilent Technologies InfiniiVision 6000 Series - page 130

    130 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope Selecting T rigger Modes and Conditions The trigger mode affects the way in which the oscilloscope searches for the trigger . The f igure below sho ws th e conceptual represent ation of acquisition m emor y. Think of the tr igger ev ent as dividing acquisition memo r y into a ...

  • Agilent Technologies InfiniiVision 6000 Series - page 131

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 131 T rigger modes: Normal and Auto An introduction to Normal and A u to trigger modes is given on page 80 . 1 Press the Mode/Coupling ke y. 2 Press the Mode sof tke y , t hen select Normal or Auto . • Normal mode displa ys a wav e f or m when the trigger conditions are met, ot ...

  • Agilent Technologies InfiniiVision 6000 Series - page 132

    132 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope Normal mode Use Normal trigger mode f or lo w repetitive-rate sign als or when A u to trigger is not required. In Normal mode the oscilloscope must fill t he pre-trigger buff er with dat a before it will begin sear ching for a trigger ev ent. The trigger mode indicator on the ...

  • Agilent Technologies InfiniiVision 6000 Series - page 133

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 133 T o select trigger Coupling 1 Press the Mode/Coupling ke y. 2 Press the Coupling sof tk ey , t hen select DC, AC, or LF Reject coupling. • DC coupling allo ws DC and A C signals int o the trigger path. • AC coupling places a 10 Hz (3.5 Hz in 100 MHz bandwidth models) high ...

  • Agilent Technologies InfiniiVision 6000 Series - page 134

    134 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope • HF Reject adds a 50 kHz lo w-pass f ilter in the trigger path to remov e high frequency components fr om t he trigger wa veform. Y ou can use HF Reject to remo ve h i g h - f r e q u e n c y n o i s e , s u c h a s A M o r F M b r o a d c a s t s t a t i o n s or noise fr ...

  • Agilent Technologies InfiniiVision 6000 Series - page 135

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 135 Holdoff Operating Hints Holdoff keeps a trigger from occurri ng until after a certain amount of time has passed sinc e the last trigger . This feat ure is valuable when a wavef orm crosses the trigger level multip le times during one period of the waveform. Without holdoff, t ...

  • Agilent Technologies InfiniiVision 6000 Series - page 136

    136 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope The External T rigger input Th e Ex te r nal T rig ger inpu t c an b e u sed as a so urce in sever al o f the trigger types. On 2-channel oscilloscopes, the ext ernal trigger BNC in put is on the front panel and is labeled Ext T rigger . On 4-channel oscilloscopes, the ext er ...

  • Agilent Technologies InfiniiVision 6000 Series - page 137

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 137 When you connect an Au t oProbe self-sensing probe, the oscilloscope will automatically configure your probe to the correct atten uation factor . Note t hat the AutoProbe f eature is not available on 100 MHz bandwidth models. The probe correction factor m ust be set pr operly ...

  • Agilent Technologies InfiniiVision 6000 Series - page 138

    138 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope • 1M Ohm mode is for use with many passive probes and f or general-purpose measu rements. The higher im pedance minimizes the loading effect of the oscilloscope on the circ uit under test. Probe Units P ress the Un its softkey to select the proper measurement unit for the c ...

  • Agilent Technologies InfiniiVision 6000 Series - page 139

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 139 T rigger T ypes The oscilloscope lets you synchronize the display to t he actions of th e circuit under test by def i ning a trigger condition. Y ou can use any in put channel or t he Ext Trigger BNC as t he source f or most trigger types. These trigger type s are available a ...

  • Agilent Technologies InfiniiVision 6000 Series - page 140

    140 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope T o use Edge triggering The Edge trigger type id entif ies a trigger b y looking for a specified edge (slope) and voltage level on a wa vef or m. Y ou can define t he trigger source and slope in this menu. The slope can be set to rising edge or falling edge, and can be set to ...

  • Agilent Technologies InfiniiVision 6000 Series - page 141

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 141 3 Select the trigger sour ce. Y ou can select analog channel 1 or 2, Ext, or Line as t he trigger source on an y A gilent 6000 Series oscilloscope. The trigger source can also be set to channel 3 and 4 on the 4-channel oscilloscopes, or di gital channels D15 t hr ough D0 on t ...

  • Agilent Technologies InfiniiVision 6000 Series - page 142

    142 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope set the t hreshold lev el (TTL, CMOS , ECL, or us er defined) for the select ed digital channel g r oup. The t hreshold value is displa yed in the upper -right corner of the display. When Ext (Exter nal Trigger) is selected, its l evel can be adj ust ed using the Level knob i ...

  • Agilent Technologies InfiniiVision 6000 Series - page 143

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 143 The channel you select is sho wn in t he upper -right corner of the d isp la y nex t to th e pol arit y sym bol . The source can be any analog or digital channel avail able on y our oscillosco pe. Exter nal tri g ger may also be specified as a source when using a 2-channel os ...

  • Agilent Technologies InfiniiVision 6000 Series - page 144

    144 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope F or example, f or a positive pulse, if y o u set t>10 ns: • within a range of time values ( >< ). F or example, f or a positive pulse, if y o u set t>10 ns and t<15 ns: 5 Select the qualifier time set softk ey ( < or > ), then r otate th e Entr y knob ...

  • Agilent Technologies InfiniiVision 6000 Series - page 145

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 145 T o use Pattern triggering The Patter n trigger identif ies a tr igge r condition by looking for a specifi ed patter n. This patter n is a logical AND combination of the channels. Each channel can ha ve a value of high (H), low (L), don't care (X). A rising or falli ng e ...

  • Agilent Technologies InfiniiVision 6000 Series - page 146

    146 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope A djust t he trigger lev el for the selected analog channel by turning the Trigger Lev el knob. Press the D15 Thru D0 ke y a n d select Thresholds to se t the th resh old l ev el fo r dig ital channels. The value of the trigge r lev el or digit al threshold is displa yed in t ...

  • Agilent Technologies InfiniiVision 6000 Series - page 147

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 147 Hex Bus Pattern T riggering Y ou can s pecify a bus value on which t o trigger . To do this, f irst define the bus. See “T o display digital channels as a bus” on page 122 for details. Y ou can trigger on a bus value whet her y ou are displa ying t he bus or not. T o trig ...

  • Agilent Technologies InfiniiVision 6000 Series - page 148

    148 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope T o use CAN triggering Controller Area N etwork (C AN) trigger will trigger on CAN version 2.0A and 2.0B signals. Setup consists of connecting t he oscilloscope to a CAN signal, using the Settings menu to specify the event to trigger on, and using the Signals men u to s peci ...

  • Agilent Technologies InfiniiVision 6000 Series - page 149

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 149 softkey , t hen press the Settings soft k ey to display C AN trig ger menu. 2 Repeat edly press and release the T rigger: so f tk ey or r otate the Entr y knob to select the trigger condition. • SOF - Start of Frame — The oscilloscope tr iggers at the st ar t of a frame. ...

  • Agilent Technologies InfiniiVision 6000 Series - page 150

    150 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope • Error Frame - The oscilloscope wi ll trigger on C A N activ e error frames. • All Errors - The oscilloscope wil l trigger when any f or m error or active error is encountered. • Acknowledge Error - The oscilloscope will trigger when the ackno wledge bit is recessive ( ...

  • Agilent Technologies InfiniiVision 6000 Series - page 151

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 151 5 Repeat edly press and release the Baud softke y to set the CAN si gnal baud rate to matc h y our C AN bu s si gnal . The CAN baud rate can be set t o: The default baud rate is 1 Mb/s 6 Repeatedly press and release t he Smpl Pt sof tk ey to select t he point between phase se ...

  • Agilent Technologies InfiniiVision 6000 Series - page 152

    152 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope T o use Duration triggering Duration trigger lets you define a patter n, then trigger on a specified time duration of this logical AND combin ation of t he channels. 1 Press the More ke y in t he Trigger section of the front panel, rotat e the Entr y knob un til Duration is d ...

  • Agilent Technologies InfiniiVision 6000 Series - page 153

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 153 A djust t he trigger lev el for the selected analog channel by turning the Trigger Lev el knob. Press the D15 Thru D0 ke y a n d select Thresholds to se t the th resh old l ev el fo r dig ital channels. The value of the trigge r lev el or digit al threshold is displa yed in t ...

  • Agilent Technologies InfiniiVision 6000 Series - page 154

    154 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope < qualifier time set softkey • When the less than ( < ) qu alifier is s elected, the E ntr y knob sets the oscilloscope t o trigger on a patter n duration less than t he time value displa yed on the so ftke y. • When the within time range ( >< ) qualifier is s ...

  • Agilent Technologies InfiniiVision 6000 Series - page 155

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 155 T o use FlexRay triggering The N5432A FlexRa y triggering an d decode option, along wit h the A gilent VPT1000 pr ot ocol analyzer and its MSO communications cable, allo w a 6000 Series mixe d-signal oscilloscope to: • Control the VPT1000 (without a PC). • Trigg er on Fle ...

  • Agilent Technologies InfiniiVision 6000 Series - page 156

    156 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope Oscilloscope Cont rols the VPT1000, Synchronous Mode Monitoring Y ou can see a synchronous and time-correlat ed displa y of segment and slot timing boun daries by importing a FIBEX (Field Bus Exchange f ormat) f ile t hat defines the g lobal FlexRay schedule. PC Controls the ...

  • Agilent Technologies InfiniiVision 6000 Series - page 157

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 157 Specifying the V PT1000 LAN Address This is necessar y when the oscilloscope controls the VPT1000 (but not when a PC with J8130A Option 200 sof tware controls the VPT1000). 1 From the VPT1000 Menu, press the LAN Address softke y to access the VPT1000 L AN Addresses Menu. 2 En ...

  • Agilent Technologies InfiniiVision 6000 Series - page 158

    158 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope Note that the VPT1000 is shipped pre-conf igured with an IP address of 192.168.80.<serial number>, and a subnet mask of 255.255.240.0. See the VPT1000 user manual for more information. 4 Set the oscilloscope’s IP address: 1 Press Utility & IO & Control . Desel ...

  • Agilent Technologies InfiniiVision 6000 Series - page 159

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 159 In Asynchronous Mode 1 Press the Baud sof tk ey to select a baud rate of 2.5 Mb /s , 5M b / s , or 10 Mb/s . 2 Press the Channel sof tk ey to select channel A or B . In Synchronous Mode 1 Press the FIBEX File softke y to specify the locat ion of the FIBEX (Field Bus Exchange ...

  • Agilent Technologies InfiniiVision 6000 Series - page 160

    160 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope T riggering on FlexRay Fr ames, Times, or Erro rs Accessing the FlexRay T r igger Menu 1 In the T rigger section on the front panel, press the More key . 2 Press the T rigger softke y , and use the Entr y knob to select FlexRay . 3 Press the Settings softkey to access the Fle ...

  • Agilent Technologies InfiniiVision 6000 Series - page 161

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 161 This is the c y cle count in the frame heade r , not th e instance in time where that cycle begins. 5 Press the Frame T ype softkey to select the frame type value from: • All Frames • Startup Frames • NULL Frames • Sync Frames • Normal Frames • NOT Startup Frames ...

  • Agilent Technologies InfiniiVision 6000 Series - page 162

    162 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope 4 Press the Cyc C t Bas sof tk ey , and use t he Entr y knob to select the cycl e count base value from 0 thr ough the Cyc C t Rep value minus 1, or All . 5 Press the Segment sof tk ey t o select the type of segments from: • Static Segments • Dynamic Segments • Symbol S ...

  • Agilent Technologies InfiniiVision 6000 Series - page 163

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 163 • TSS Violation — transmission star t sequence violation. • Header CRC Error — cy clic redundan cy check er ror in the header . • Frame CRC Error — cy clic redundancy check error i n t he frame. • Frame End Sequence Error — i ndi cates that th e FES has b een ...

  • Agilent Technologies InfiniiVision 6000 Series - page 164

    164 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope T o use I 2 C triggering An I 2 C (Inter -IC bus) trigger setup consists of connecting t he os ci llo sc ope to the s er ial da ta (S D A) lin e a nd the s er ial cl oc k (SCL) line, then triggering on a st op/star t condition, a rest art, a missing ackno wledge, an EEPROM da ...

  • Agilent Technologies InfiniiVision 6000 Series - page 165

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 165 2 Press the Signals sof tk ey to display the I 2 C signals menu. 3 Connect an oscilloscope channel to the SCL (serial clock) line in t he cir cui t un der te st, th en se t the SCL clock channe l so f tk ey to that chan nel. As yo u press t he SCL so ftk e y (o r r otat e th ...

  • Agilent Technologies InfiniiVision 6000 Series - page 166

    166 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope Dat a needs to be stable during the whole high clock cy cle or it will be interpreted as a st ar t or stop condition (data transitioning while t he clock is high). 6 Ret urn to the pr evi ous menu ; then , pre ss the T rigger: softkey to select one of the follo wing I 2 C tri ...

  • Agilent Technologies InfiniiVision 6000 Series - page 167

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 167 • EEPROM Data Read — The trigger look s f or EEPROM control byte value 1010xxx on the SD A line, follo wed by a Read bit and an A c k bit. It then looks for the dat a value and qualif ier set by the Data softkey and the Data is sof tk ey. When this eve nt occurs, t he osc ...

  • Agilent Technologies InfiniiVision 6000 Series - page 168

    168 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope • Frame (Start: Addr 7: Read: Ack: Data: Ack: Data2) or Frame (Start: Addr7: W rite: Ack: Data: Ack: Data2) — The oscilloscope triggers on a read or write frame in 7-bit addressing mode on the 26t h clock edge if all bits in t he patter n match. For triggering purposes, a ...

  • Agilent Technologies InfiniiVision 6000 Series - page 169

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 169 Press the Data is softkey to set the oscilloscope to trigger when data is = (equal t o), ≠ (not equal to), < (less than), or > ( greate r tha n) the data v alue set in the Data sof tk ey. The oscilloscope will trigger on the clock edge for the Ack bit aft er the trigg ...

  • Agilent Technologies InfiniiVision 6000 Series - page 170

    170 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope T o use Nth Edge Burst triggering The Nth Edge Burst trigger lets yo u trigger on the Nth edge of a burst that occurs af ter an idle time. Nth Edge Burst trigger set up co ns ists of selecting the source, the slope of the edge, t he idle ti me, and t he number of the edge: 1 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 171

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 171 3 Press the Slope sof tke y t o specify t he slope of t he edge. 4 Press the Idle sof tk ey; then, turn t he Entr y knob to specify the i dle time . 5 Press the Edge softk ey; then, turn th e Ent r y kn ob to whic h edge to trigger on. Assign channels Slope of edge Idle time ...

  • Agilent Technologies InfiniiVision 6000 Series - page 172

    172 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope T o use LIN triggering LIN (Local Interconnect Netw or k) tr igger setup consists of connecting t he oscilloscope to a seri al LIN signal. LIN triggering will trigger on th e rising edge at the Sync Break exit of th e LIN single-wire bu s signal that mark s the b eginning of ...

  • Agilent Technologies InfiniiVision 6000 Series - page 173

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 173 1 Press the More ke y in t he Trigger section of the front panel, rotate t he Entr y knob until LIN is display ed in t he T rigger sof tk ey. 2 Press the Settings sof tk ey to display LIN trigger menu. 3 Press the T rigger: sof tk ey and choose to trigger on Sync Break or Fra ...

  • Agilent Technologies InfiniiVision 6000 Series - page 174

    174 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope 4 Press the Signals sof tk ey. The LIN Signals Menu will be display ed. 5 Press the Source sof tk ey to select the channel connected t o the L IN s igna l li ne. A djust t he trigger lev el for the selected analog channel by turning the Trigger Lev el knob. Press the D15 Thru ...

  • Agilent Technologies InfiniiVision 6000 Series - page 175

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 175 T o use Sequence triggering Sequence trigge r lets y ou trig ger the oscillo scope aft er f inding a sequence of ev ents. Def ining a sequence trigger requ ires three steps: 1 Define an event to find befo re y ou search for the trigger . The “find” event can be a pattern, ...

  • Agilent Technologies InfiniiVision 6000 Series - page 176

    176 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope As y ou set st age, ter m, and channel definitions for the sequence trigger , these s ettings will be sho w n in the wa veform area of the displa y. Channel select Stage select Find, Trigge r on, or Reset condition Define term Trigger level or threshold Sequence trigger Retur ...

  • Agilent Technologies InfiniiVision 6000 Series - page 177

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 177 Define the Find: stage 1 Press the Stage sof tk ey and select Find: . Find : is the f irst st age in the trigger sequence. When y ou select the Stage Find sof tke y , t he next sof tk ey to t he right will displa y Find: and give y ou a list of t he terms you can define f o r ...

  • Agilent Technologies InfiniiVision 6000 Series - page 178

    178 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope • X sets the patt ern t o don't care on the select ed channel. An y channel set t o don't care is ignored and is not used as par t of the patter n. If all channels in the patter n are set to don't care, th e oscilloscope will not trigger . A djust t he trigge ...

  • Agilent Technologies InfiniiVision 6000 Series - page 179

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 179 • Pattern 2 Entered — A pattern is ent ered on the last edg e that mak e s the patter n true (logical AND). • Pattern 2 Exited — A patter n is exited on the f irst edge that mak e s the patter n false (logical N AN D). • Edge 2 • Pattern 2 and Edge 2 • Nth Edge ...

  • Agilent Technologies InfiniiVision 6000 Series - page 180

    180 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope When Nth Edge 2 (no re-find) is selected, if the Find event occurs again bef ore t he Count (N) ev ent is satisf ied, the Count (N) is not reset to zero. b Press the Te r m sof tk ey and select Count (N) . c Press the N sof tk ey , t hen turn the Entr y knob t o set the numbe ...

  • Agilent Technologies InfiniiVision 6000 Series - page 181

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 181 5 If yo u select a patt ern t erm, each channel in th e pattern must be set to a H (high), L (l ow), or X (don't care). a Press the Channel so ftk ey (o r r ota te th e E nt r y k no b o n mix ed-signal oscilloscopes) t o select the channel. b Press the L H X sof tk ey t ...

  • Agilent Technologies InfiniiVision 6000 Series - page 182

    182 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope T o use SPI triggering Serial P eripheral Inte rface (SPI) trigger setup consists of connecting the oscilloscope to a clock, data, and framing signal. Y ou can t hen trigger on a data patt ern that occurs at t he star t of a frame. The serial data string ca n be specif ied to ...

  • Agilent Technologies InfiniiVision 6000 Series - page 183

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 183 Assign channels # data b its in string Data bit select Set all data bits to value Trigger level or threshold Currently selected Clock, Framing, or Data channel SPI trigger Return to previous menu Data bit value Data string values Graphic showing current state of the SPI trigg ...

  • Agilent Technologies InfiniiVision 6000 Series - page 184

    184 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope Assign source channels to the clock, data, and frame signals 1 Press the Signals sof tk ey to access SPI trigger settings for clock source and slope, data source, and frame type and source. 2 Press the Clock sof tk ey or turn t he Entr y knob to select t he channel connected ...

  • Agilent Technologies InfiniiVision 6000 Series - page 185

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 185 4 Press the Dat a softkey or turn the Entr y knob t o select the channel that is connect ed to th e SPI serial dat a line. (If t he channel you selected is of f, switch it on.) As yo u press t he Data s oft ke y ( or ro tate the En try kn ob on mix ed-signal oscilloscopes), t ...

  • Agilent Technologies InfiniiVision 6000 Series - page 186

    186 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope Y ou can set t he oscilloscope to trigger during a high chip select ( CS ), a low chip select ( ~CS ), or afte r a Time o ut period during which the clock signal has been idle. • If the frami ng signal is set to CS (or ~CS ), t he firs t clock edge as defined, rising or fal ...

  • Agilent Technologies InfiniiVision 6000 Series - page 187

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 187 The Timeout value can be set anywhere from 100 ns to 10 s. 6 Pr ess th e up- arro w so f t ke y to r eturn to the p rev ious menu . Set up the number of bits in the seri al data string and set values for those data bits 1 Press the #Bits sof tk ey , and turn t he Entr y knob ...

  • Agilent Technologies InfiniiVision 6000 Series - page 188

    188 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope The oscilloscope’s MegaZoom III t echnology gives y ou bri ght, easily vie wed displa ys of any part of t he video wav eform. Analysis of video wa vef o rms is simplified by the oscilloscope’s ability to trigger on an y selected line of the video signal. 1 Press the More ...

  • Agilent Technologies InfiniiVision 6000 Series - page 189

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 189 The select ed trigger source is display ed in t he upper-right corner of the displa y. T urning the Trigger Level knob does not change th e trigger lev el becau se the trigger level is au tomat ical ly set to the sy nc pulse. Trigger coupling is automatically set to TV in t h ...

  • Agilent Technologies InfiniiVision 6000 Series - page 190

    190 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope • Line — Trig ger on the select ed line # (EDT V and H DT V stan dar ds only ). • Line: Field1 and Line:Field2 — Trigger on the selected line # in field 1 or f ield 2 (interlace d st andards only ex cept 1080i). • Line: Alternate — Altern atel y tr igg er on the s ...

  • Agilent Technologies InfiniiVision 6000 Series - page 191

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 191 Ta b l e 1 2 Line (or count for Generi c) numbers per field for each non-HDTV/EDTV vi deo standard Ta b l e 1 3 Line numbers for each EDTV/HD TV video standard Example exercises The f ollo wing are exer cises to familiarize y ou with T V triggering. These exercises use th e N ...

  • Agilent Technologies InfiniiVision 6000 Series - page 192

    192 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope O n e e x a m p l e o f t r i g g e r i n g o n a s p e c i f i c l i n e o f v i d e o i s l o o k i n g a t the vertical int erval test signals (VITS), which are typically in line 18. Another exam ple is closed captioni ng, which is typically in line 21. 1 Press the T rigge ...

  • Agilent Technologies InfiniiVision 6000 Series - page 193

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 193 T o trigger on all sync pulses T o quickly find maximum video le vels, y o u could trigger on all sync pulses. When All Lines is select ed as the T V trigger mode, the osci lloscope will trigger on all horizontal sync pulses. 1 Press the T rigger More k e y , then pres s the ...

  • Agilent Technologies InfiniiVision 6000 Series - page 194

    194 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope T o trigger on a specific field of the video signal T o examine the components of a video signal, tri gger on eit her Field 1 o r Field 2 (available f or int erlea ved st andards). When a specifi c field is se lected, t he oscilloscope triggers on the rising edge of the f irs ...

  • Agilent Technologies InfiniiVision 6000 Series - page 195

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 195 T o trigger on all fields of the video signal T o quickly and easily vie w transitions between fields, or t o find the amplitude dif f ere nces betw e en the f ields, use t he All Fields trigger mode. 1 Press the T rigger More k e y , then pres s the TV softke y. 2 Press the ...

  • Agilent Technologies InfiniiVision 6000 Series - page 196

    196 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope T o trigger on odd or even fields To c h e c k t h e e n v e l o p e o f y o u r v i d e o s i g n a l s , o r t o m e a s u r e w o r s t case distor tion, trigger on t he odd or even fields. When F ield 1 is selected, t he oscilloscope triggers on color f ields 1 or 3. When ...

  • Agilent Technologies InfiniiVision 6000 Series - page 197

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 197 If a mor e det ailed ana lysis is requir ed, th en only one color f ield should be selected to be the trig ger . Y ou can do this by using the TV Holdoff sof tk ey in th e trigger More T rigger Menu when th e trigger type is set to TV . Press t he TV Holdoff sof tke y and use ...

  • Agilent Technologies InfiniiVision 6000 Series - page 198

    198 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope Ta b l e 1 4 Half-field hold off time Figure 20 Using TV Holdoff to Synchronize to Color Field 1 or 3 ( F ield 1 mode) Standard Time NTSC 8. 35 ms PA L 1 0 m s PA L - M 1 0 m s SECAM 10 ms Generic 8.35 ms EDTV 480p/60 8.35 ms HDTV 720p/60 8.35 ms HDTV 1080 p/24 20.835 ms HDTV ...

  • Agilent Technologies InfiniiVision 6000 Series - page 199

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 199 T o use UART/RS232 triggering T o trigger on a U ART (Universal Asynchr onous Receiver/Transmitt er) signal connect t he oscilloscope to t he Rx and Tx lines and set up a trigger condition. RS232 (Recommended St andar d 232) is one exam ple of a U ART protocol. 1 Press the Mo ...

  • Agilent Technologies InfiniiVision 6000 Series - page 200

    200 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope 3 Press the Signals sof tk ey to display the U ART/RS232 signals menu. 4 Connect an oscilloscope channel to t he Rx signal in the circuit under test (the t arget system), t hen press the Rx so f tk ey a nd r otate the En tr y k nob to sel ect th e cha nnel . As yo u press t h ...

  • Agilent Technologies InfiniiVision 6000 Series - page 201

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 201 8 Press the Bus Config sof tke y and set t he f ollowing parameters. a# B i t s : Set the number of bits in t he U ART/RS232 wor ds t o match your targ et system (selec table from 5-9 bits). bP a r i t y : Choo se odd, ev en, or none, based o n your target system. cB a u d : ...

  • Agilent Technologies InfiniiVision 6000 Series - page 202

    202 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope • Rx X:Data: F or use when the t arget system data wor ds are 9 bits in length including the aler t bit (t he 9th bit). T riggers on a data b yte that y ou sp eci fy re gar dles s of the va lue o f the 9 th (a lert) b it. T he s peci fied d ata b yte ap plie s to th e least ...

  • Agilent Technologies InfiniiVision 6000 Series - page 203

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 203 15 Remember t o set the trig ger mode to Normal (pr ess Mode/Coupling → Mode → Normal ) to prev ent Auto Triggering. ...

  • Agilent Technologies InfiniiVision 6000 Series - page 204

    204 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope T o use USB triggering USB trigger will trigger on a St ar t of P acket (SOP), End of Pack et (EOP) signal, Reset Complete (R C), Ent er Suspend (Suspend), or Exit Suspend (Exi t Sus) on the dif f erential USB dat a lines (D+ and D-). USB Lo w Speed and F ull Speed are suppor ...

  • Agilent Technologies InfiniiVision 6000 Series - page 205

    Triggering the Oscilloscope 4 6000 Series Oscilloscope User’s Guide 205 As yo u press t he D+ or D– s oftk e y ( or ro tate the Ent ry kn ob on mix ed-signal oscilloscopes), the D+ and D– label for the source channel is automatically set and the channel y o u select is sho wn in t he upper -right corner of the displa y next to “ USB ”. A ...

  • Agilent Technologies InfiniiVision 6000 Series - page 206

    206 6000 Series Oscilloscope User’s Guide 4 Triggering the Oscilloscope The T rigger Out connector Y ou can select one of t he f ollowing signals to be output at the TRIG OUT connector on t he rear panel of the oscilloscope: • Tri gge rs • Source fre quency • Source fre quency/8 (exc ept 100 MHz BW models) T riggers This is the default sele ...

  • Agilent Technologies InfiniiVision 6000 Series - page 207

    207 Agilent T echnologies Agilent 6000 Series Oscilloscope User’s Guide 5 Making Measurements T o use the XY horizontal mode 208 Math Functions 213 Cursor Measurements 232 Automatic Mea surements 239 Post Acquisition Processing In additi on to changing display paramete rs after the acquisition, you c an perform all of the measurements an d math f ...

  • Agilent Technologies InfiniiVision 6000 Series - page 208

    208 6000 Series Oscilloscope User’s Guide 5 Making Measurements T o use the XY horizontal mode The XY horizont al mode conv er ts the oscilloscope from a v olts-versus-time display to a v olts-versus-volts displa y using tw o input channels. Channel 1 is the X-axis in put, channel 2 is the Y -axis input. Y ou can use various transducers so the d ...

  • Agilent Technologies InfiniiVision 6000 Series - page 209

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 209 Figure 21 Exampl e of centering a signal on th e display Figure 22 Signal centered on the di splay 4 Press the Cursors key . 5 Se t the Y 2 cur sor to the top of th e sig nal , and set Y 1 to the bottom o f the signal. A B D C Signal must be centered in “X” ...

  • Agilent Technologies InfiniiVision 6000 Series - page 210

    210 6000 Series Oscilloscope User’s Guide 5 Making Measurements N ote the ∆ Y value at t he bottom of t he displa y. In t his examp le, we are using the Y cursors, but y ou could ha ve used the X cursors in stead. Figure 23 Cursors set on displayed signal 6 Mo ve the Y1 and Y 2 cursors to the inte rsection of the signal and the Y axis. Again, n ...

  • Agilent Technologies InfiniiVision 6000 Series - page 211

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 211 7 Calculate t he phase dif f erenc e using the formula be lo w . Figure 24 Cursors set to center of signal Z- Axis Input in XY Display Mode (Blanking) When you select the XY dis play mode, the time base is turned off. Ch annel 1 is the X -axis input, ch annel 2 is the Y -axis inpu t, ...

  • Agilent Technologies InfiniiVision 6000 Series - page 212

    212 6000 Series Oscilloscope User’s Guide 5 Making Measurements Figure 25 Signals are 90 out of phase Figure 26 Signals are in phase ...

  • Agilent Technologies InfiniiVision 6000 Series - page 213

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 213 Math Functions The Math menu lets you displa y mat h functions on analog channels. Y ou can: • subtract (–) o r multiply (*) th e signals acquired on analog channels 1 and 2, then display the result. • integ rate, dif f er entiate, per form an FFT , or t he square root function ...

  • Agilent Technologies InfiniiVision 6000 Series - page 214

    214 6000 Series Oscilloscope User’s Guide 5 Making Measurements Math scale and offset An y math function may be manually scaled by pressing the Scale or Offset softke ys and t hen adjusting the value. 1 In th e W a v ef orm Ma th Men u f or the sel ected math f unct ion , press the Scale or Offset sofke ys t o set y our own scale factors (units/d ...

  • Agilent Technologies InfiniiVision 6000 Series - page 215

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 215 Multiply When y ou select 1*2 , channel 1 and channel 2 v olt age values are multiplied point by point, and the result is displayed. 1 * 2 is useful for seeing po wer relationships when one of t he channels is proportional t o the cur rent. 1 Press the Math key, p re s s t h e 1*2 so ...

  • Agilent Technologies InfiniiVision 6000 Series - page 216

    216 6000 Series Oscilloscope User’s Guide 5 Making Measurements The figure below sho ws an example of multipl y. Figure 27 Mult iply Channel 1 Channel 2 1 * 2 waveform 1 * 2 Scale 1 * 2 Offset Math Function Math Function ...

  • Agilent Technologies InfiniiVision 6000 Series - page 217

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 217 Subtract When y ou select 1–2 , channel 2 v olt age values are subtracted from channel 1 v olt age values point b y point, and t he result is display ed. Y ou can use 1 – 2 to make a diff eren tial measurem ent or t o compare tw o wave forms. Y ou may need to use a tr ue differen ...

  • Agilent Technologies InfiniiVision 6000 Series - page 218

    218 6000 Series Oscilloscope User’s Guide 5 Making Measurements The figure below sho ws an example of subtract. Figure 28 Subtract Channel 1 Channel 2 1 – 2 waveform 1 – 2 Scale 1 – 2 Offset ...

  • Agilent Technologies InfiniiVision 6000 Series - page 219

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 219 Differentiate d/dt (differentiate) calculates the di screte time derivative of t he selected source. Y ou can us e differentiate t o measure t he inst antaneous slope of a wav eform. Fo r example, the slew rate of an operational amplifier m a y be me asured using the dif f erentiat e ...

  • Agilent Technologies InfiniiVision 6000 Series - page 220

    220 6000 Series Oscilloscope User’s Guide 5 Making Measurements • Offset —lets yo u s et y our own offset f or t he dV/dt math function. The offset value is in units/second where units can be V (V olts), A (Am ps), or W (W atts) and is represented by the cent er horizontal g rid line of the display. Press the Offset sof tk ey , t hen turn the ...

  • Agilent Technologies InfiniiVision 6000 Series - page 221

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 221 Integrate ∫ dt (integ rate) calculat es the in tegral of t he select ed source. Y ou can use integrate t o calculate the energy of a pulse in v olt-seconds or measure the area under a wa vef orm. ∫ dt plot s the inte gral of th e sou rc e usi ng th e “Tr apez oid al R ule” . ...

  • Agilent Technologies InfiniiVision 6000 Series - page 222

    222 6000 Series Oscilloscope User’s Guide 5 Making Measurements Figure 30 Integrate and Signal Offset Channel 1 ∫ dt waveform ∫ dt Scale ∫ dt Offset Source select Channel 1 ∫ dt waveform 0 V 0 V ...

  • Agilent Technologies InfiniiVision 6000 Series - page 223

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 223 FF T Measurement FFT is used to compute the fast F ourier transform using analog input cha n nels or math functions 1 + 2, 1 – 2, or 1 * 2. FFT takes the digitized ti me record of t he specified sour ce and transf orms it to t he frequency domain. Whe n the FFT function is selected ...

  • Agilent Technologies InfiniiVision 6000 Series - page 224

    224 6000 Series Oscilloscope User’s Guide 5 Making Measurements vertical bandwidth when making FFT meas urements. The FFT sample rate is displa yed directly abo ve the sof tke ys when t he FFT menu is display ed . Aliasing happens when t here are frequency components in the si gnal high er tha n hal f the sa mp le ra te. Si nce th e FFT sp ect r ...

  • Agilent Technologies InfiniiVision 6000 Series - page 225

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 225 Spectral Leakage The FFT operation assumes that t he time record repeats. U nless there is an int egral number of cycles of the sampled wa vef or m in the reco rd, a discontinuity is create d at the end of t he record. This is referred to as leakage. In order t o minimize spectral le ...

  • Agilent Technologies InfiniiVision 6000 Series - page 226

    226 6000 Series Oscilloscope User’s Guide 5 Making Measurements • Center — se ts t he FFT spectrum frequency represented at the center vertical gr id line of the display. It is possible to set the Cent er to values belo w half the span or abo ve the maximum available frequency , in which case t he displa yed spectrum will not t ake up the who ...

  • Agilent Technologies InfiniiVision 6000 Series - page 227

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 227 • Scale — lets you set y our o wn vertical scale factors for FFT expressed in dB/div (d ecibels/division). Press t he Scale softkey , t hen turn t he Entry knob t o rescale y our mat h function. • Offset — lets you set your o wn of fset for the FFT . The of fset value is in d ...

  • Agilent Technologies InfiniiVision 6000 Series - page 228

    228 6000 Series Oscilloscope User’s Guide 5 Making Measurements Figure 32 FF T measurements FF T Measurement Hints The number of points acquired f or t he FFT record is 1000 and when frequency span is at maxi mum, all points are displa yed. Once the FFT spectrum is disp layed, the frequency span and center frequency controls are used much lik e t ...

  • Agilent Technologies InfiniiVision 6000 Series - page 229

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 229 resolve tw o c losely space frequencies. A good way to test t he ability of the FFT to resolve tw o closely spaced frequencies is to examine the sidebands of an amplitude modulated sine wav e. F or th e best v er tical accuracy on peak measurements: • Mak e sure t he probe attenuat ...

  • Agilent Technologies InfiniiVision 6000 Series - page 230

    230 6000 Series Oscilloscope User’s Guide 5 Making Measurements Square Root √ (square root) calculates the square root of t he selected source. In Zoom mode, the √ (square root) function does not display in the zoomed por tion of t he displa y. 1 Press the Math ke y , press the √ (squ are root) softkey , then press the Source , Scale , or O ...

  • Agilent Technologies InfiniiVision 6000 Series - page 231

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 231 The figure below sho ws an example of √ (square r oot). Figure 33 Square Root Channel 1 √ waveform √ Scale √ Offset Source select ...

  • Agilent Technologies InfiniiVision 6000 Series - page 232

    232 6000 Series Oscilloscope User’s Guide 5 Making Measurements Cursor Measurements Y ou can measure wav eform dat a using cursors. Cursors are horizont al and v er tical markers that indicate X-axis values (usually time) and Y -axis values (usually v o ltage) on a selected wa veform source. The position of the cursors can be mov e d b y turning ...

  • Agilent Technologies InfiniiVision 6000 Series - page 233

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 233 • Binary — Binar y logic lev els are display ed directly abov e the sof tk eys for the current X1 and X2 cursor positions f or all displa yed channels. • Hex — Hexadecimal logic lev els are displa yed di rectly abo ve the sof tk eys for the current X1 and X2 cursor positions ...

  • Agilent Technologies InfiniiVision 6000 Series - page 234

    234 6000 Series Oscilloscope User’s Guide 5 Making Measurements 4 Select the X and Y sof tke ys t o mak e a measurement. • XY — Press t his softke y t o select either X cursors or Y cursors for adjustment. The cursor cur rently assigned to the E ntry kn ob di spla ys b righ ter tha n the o ther c urs ors. X cursors are v er tical dashed lines ...

  • Agilent Technologies InfiniiVision 6000 Series - page 235

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 235 T u r n t h e E n t r y k n o b t o a d j u s t t h e Y 1 o r Y 2 c u r s o r w h e n i t s softkey is selected. • X1 X2 — Press this sof tke y t o adjust the X1 and X2 cursor s together by turning the Entr y knob. The ∆ X value will remain the same since t he cursors adjust to ...

  • Agilent Technologies InfiniiVision 6000 Series - page 236

    236 6000 Series Oscilloscope User’s Guide 5 Making Measurements Cursor Exam ples Figure 34 Curs ors measure pulse widths other than middle threshold points Figure 35 Curs ors measure frequency of pulse rin ging ...

  • Agilent Technologies InfiniiVision 6000 Series - page 237

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 237 Exp and the di spla y with zoo m sw eep , then cha racte rize the e ven t of inter est with the cur sors . Figure 36 Cursors track zoom sweep Put the X1 cursor on one side of a pulse and t he X2 cursor on the other side of t he pulse. Figure 37 Measur ing pulse width with cur sors ...

  • Agilent Technologies InfiniiVision 6000 Series - page 238

    238 6000 Series Oscilloscope User’s Guide 5 Making Measurements Press the X1 X2 softk ey a nd mo v e the cu rso rs tog ether to ch eck f or pulse widt h variations in a pulse train. Figure 38 Moving the cursors together to check pulse width variat ions ...

  • Agilent Technologies InfiniiVision 6000 Series - page 239

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 239 Automatic Measurements The follo wi ng automatic meas urements can be made in t he Quick Meas menu. T i me Measurements • Counter • Duty Cy cle • Fre que nc y • Pe r i od • Rise Time* • Fall Time* • + Width • – Widt h • X at Max* • X at Min* Phase an d Delay • ...

  • Agilent Technologies InfiniiVision 6000 Series - page 240

    240 6000 Series Oscilloscope User’s Guide 5 Making Measurements Preshoot and Overshoot • Preshoot* • Overshoot* * Measurement on analog channels only. T o make an automatic measurement A brief description of how to ma ke aut omatic measurements is given on page 96 . Quick Meas mak es aut omatic measurements on an y channel source or an y r un ...

  • Agilent Technologies InfiniiVision 6000 Series - page 241

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 241 If a por tion of the wav eform required for a measurement is not displa yed or does not display enough resolution to mak e the measurement, the result will displa y “No Edges”, “Clipped”, “Lo w Signal”, “< valu e”, or “> value”, or a similar me ssag e to in ...

  • Agilent Technologies InfiniiVision 6000 Series - page 242

    242 6000 Series Oscilloscope User’s Guide 5 Making Measurements thresholds. Each analog channel and the math wav eform can be assigned unique t hreshold values. 3 Press the Ty p e sof tke y t o set the measurement t hreshold to % (percentage of T op and Base value) or t o Absolut e (absolut e value.) • P ercent age thresholds can be set from 5% ...

  • Agilent Technologies InfiniiVision 6000 Series - page 243

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 243 • If threshold Ty p e is set to % , the middle t hreshold value can be set from 6% to 94%. 6 Press the Upper sof tke y , t hen turn t he Entr y knob to set t he upper measurement t hreshold value. Decreasing the upper value below the set middle value will automatically decrease the ...

  • Agilent Technologies InfiniiVision 6000 Series - page 244

    244 6000 Series Oscilloscope User’s Guide 5 Making Measurements Counter The 6000 Series oscilloscopes ha ve an integ rated hardware frequency co unter which coun ts the number of cy cl es that occur within a period of time (known as the gate time ) to mea sure the frequency of a signal. The gate time f or the Coun ter me asu reme nt is auto mati ...

  • Agilent Technologies InfiniiVision 6000 Series - page 245

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 245 through the low er and upper threshold levels which eliminates runt pulses. The X cursors sho w what por tion of the wav e f orm is being measured . The Y cursor sho ws t he middle t hreshold point. T o isolate an event for frequency measurement The fol lowing figure shows ho w t o u ...

  • Agilent Technologies InfiniiVision 6000 Series - page 246

    246 6000 Series Oscilloscope User’s Guide 5 Making Measurements Fall T i me The fall time of a signal is the time dif f erence between the crossing of the upper t hreshold an d th e c ro ssi ng of the l o w er threshold for a negative -going edge. The X cursor shows the edge being me asured. F or maximum measurement ac curacy , set the sweep spee ...

  • Agilent Technologies InfiniiVision 6000 Series - page 247

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 247 T o measure the peak of an FFT: 1 Select FF T as th e math fun ctio n in th e Math menu. 2 Choose Math as the so ur ce in t he Quick Meas menu. 3 Choose Maximum and X at Max measurements. Maximum units are in dB and X at Max units are in Her tz for FFT . X at Min X at Min is the X ax ...

  • Agilent Technologies InfiniiVision 6000 Series - page 248

    248 6000 Series Oscilloscope User’s Guide 5 Making Measurements 1 Press the Quick Meas & Select and select Delay . Press the Settings softkey to select the sour ce channels and slope for the delay measurement. The default Dela y settings measur e from t he rising edge of channel 1 to th e rising edge of channel 2. 2 Press the Measure Delay so ...

  • Agilent Technologies InfiniiVision 6000 Series - page 249

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 249 1 Press the Settings sof tk ey to select t he source 1 and sour ce 2 channels f o r the phase measurement. The default Phase settings measure from channel 1 to channel 2. The example belo w shows a phase measurement betw een the channel 1 and the mat h d/dt function on channel 1. Fig ...

  • Agilent Technologies InfiniiVision 6000 Series - page 250

    250 6000 Series Oscilloscope User’s Guide 5 Making Measurements and ∫ dt when 1-2 or 1+2 is the select ed source if channel 1 and channel 2 are set to dissimilar units in t he channel Probe Units softkey. The f ollo wing f igure sho ws the voltage measurement points. Math Measurements and Units Only Peak-Peak, Maximum, Minimum, A ver age, X at ...

  • Agilent Technologies InfiniiVision 6000 Series - page 251

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 251 Amplitude The Amplitude of a wa veform is the dif ference betw een its T op and Base va lues. The Y cursors show the value s being measured. Av er ag e A verage is t he sum of the wa vef or m samples di vided by the number of samples o ver one or mor e full periods. If less than one ...

  • Agilent Technologies InfiniiVision 6000 Series - page 252

    252 6000 Series Oscilloscope User’s Guide 5 Making Measurements RMS RMS (DC) is the root-mean-square valu e of t he wa vef or m o ver one or more full periods. If less t han one period is display ed, RMS (DC) a verage is calculated on t he full width of t he displa y. The X cursors sho w what int erval of the wa vef or m is being measured. Std De ...

  • Agilent Technologies InfiniiVision 6000 Series - page 253

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 253 The mean is calculated as follo ws: where: x = the mean. N = the nu mber of measuremen ts taken. x i = the i th measurement result. The st andar d de viation is calculat ed as fo llows: where: σ = the st andard deviation. N = the nu mber of measuremen ts taken. x i = the i th measur ...

  • Agilent Technologies InfiniiVision 6000 Series - page 254

    254 6000 Series Oscilloscope User’s Guide 5 Making Measurements Top The T op of a wav eform is the mo de (most common value) of the upper par t of the wav eform, or if t he mode is not w ell def ined, the to p is the sa me as Max imum . The Y cur sor s ho ws the v alu e being measur ed. T o isolate a pulse for T op measurement The follo wing f ig ...

  • Agilent Technologies InfiniiVision 6000 Series - page 255

    Making Measurements 5 6000 Series Oscilloscope User’s Guide 255 Overshoot and Preshoot Measurements Preshoot Preshoot is distortion that precedes a major edge transition expressed as a percentage of Amplitude. The X cursors show which edge is being m easured (edge closes t to the trigger reference point). Digital channel time measurements Automat ...

  • Agilent Technologies InfiniiVision 6000 Series - page 256

    256 6000 Series Oscilloscope User’s Guide 5 Making Measurements Overshoot Overshoot is distortion t hat f ollows a ma jor edge transition expressed as a percentage of Amplitude. The X cursors sho w which edge is being m easured (edge closes t to the tr igger reference point). Figure 42 Automatic Oversh oot mea surement Rising edge overshoot = loc ...

  • Agilent Technologies InfiniiVision 6000 Series - page 257

    257 Agilent T echnologies Agilent 6000 Series Oscilloscope User’s Guide 6 Displaying Data Pan and Zoom 258 Antialia sing 260 Using the XGA video output 260 Display Settin gs 261 V arying the intensity to view signal detail 263 Acquisition Modes 265 Using Serial Decode 271 T o decode I2C data 272 T o decode SPI data 276 T o decode CAN d ata 281 T ...

  • Agilent Technologies InfiniiVision 6000 Series - page 258

    258 6000 Series Oscilloscope User’s Guide 6 Displaying Data Pan and Zoom The ability to pan (mo ve horizo nt ally) and zoom (expand or compress horizontally) an acqu ired wav eform is import ant because of the additional insight it can reveal about the captured wa veform. This additional insight is of ten gained from seeing the wa vef or m at dif ...

  • Agilent Technologies InfiniiVision 6000 Series - page 259

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 259 T o pan and zoom a waveform 1 Press the Run/Stop key to stop acquisitions. The Run/Stop key is illuminated red when the oscilloscope is stopped. 2 Tu rn the sweep speed knob to zoom horizont ally and t u rn the volts/division knob to zoom vertically. The ∇ sy mbol at the top of the di ...

  • Agilent Technologies InfiniiVision 6000 Series - page 260

    260 6000 Series Oscilloscope User’s Guide 6 Displaying Data Antialiasing At slo wer sw eep speeds, t he sample rate is reduced and a proprietar y display algorit hm is us ed to minimize t he lik elihood of aliasing. By default, Antialiasing is enabled. Y o u should lea ve Antialiasing enabled unless there is a specif ic reason to swit ch it of f. ...

  • Agilent Technologies InfiniiVision 6000 Series - page 261

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 261 Display Settings • Press the Display key to vie w t he Display menu. T o manually contr ol Display settings on 6000L models star t the Remote F r ont Panel (see page 44 ) and select Wa v e f o r m from the Main Menu or press ctrl+W t o access the oscilloscope’s Display Menu. Infinite ...

  • Agilent Technologies InfiniiVision 6000 Series - page 262

    262 6000 Series Oscilloscope User’s Guide 6 Displaying Data Grid intensity T o adjust t he grid (g raticule) intensity , press Display & Grid and use the E ntry kno b to adj ust th e inte nsi ty. V ectors (connect the dots) The Agilent 6000 Series oscillosco pes are designed t o operate optimally with vectors on. This mode gives the most real ...

  • Agilent Technologies InfiniiVision 6000 Series - page 263

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 263 Using V ectors (Display menu) One of t he most fundament al choices y ou must make about your displa y is whet her to draw v ect ors (connect the dots) between the samples, or sim ply let the samples f ill in the wav eform. T o some degree, t his is a matter of personal preference, but i ...

  • Agilent Technologies InfiniiVision 6000 Series - page 264

    264 6000 Series Oscilloscope User’s Guide 6 Displaying Data Figure 43 Amplitude Modulation with No ise Shown at 100% Intensity Figure 44 Amplitude Modulation wi th Noise Shown at 40% Intensit y ...

  • Agilent Technologies InfiniiVision 6000 Series - page 265

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 265 Acquisition Modes The 6000 Series oscilloscopes ha ve t he f ollo wing acquisition modes: • Normal — fo r most wavef o rms (wit h normal decimating at slo wer sw eep speeds, no av eraging). • Peak Detect — f or displaying narro w pulses t hat occur infrequently (at slo w er sweep ...

  • Agilent Technologies InfiniiVision 6000 Series - page 266

    266 6000 Series Oscilloscope User’s Guide 6 Displaying Data Normal Mode In Normal mode at slo wer sw eep speeds, extra samples are decimated (in other w ords, some are t hro wn awa y). This mode yields the best display f o r most wa veforms. Peak Detect Mode In P eak Det ect mode at slo wer sweep speeds, minimum and maximum samples are kept in or ...

  • Agilent Technologies InfiniiVision 6000 Series - page 267

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 267 Hig h Re solu tio n mode is eq uiv alen t to the A ve ragi ng mo de w ith #A verages=1; ho wev er , you can tu rn on Realtime sam pling in the H igh Reso lut ion mo de. High Resolution mode can b e used on both single-shot and repetitive signals and it does not slo w wavef orm updat e be ...

  • Agilent Technologies InfiniiVision 6000 Series - page 268

    268 6000 Series Oscilloscope User’s Guide 6 Displaying Data T o use the Averaging mode 1 Press the Acquire ke y , th en pr ess th e Acq Mode softke y until the A veraging mode is sel e cted. 2 Press the #Avgs softkey and turn the Entr y knob to set t he number of a verages that best elim inates t he noise fr om the display ed wavef o rm. The numb ...

  • Agilent Technologies InfiniiVision 6000 Series - page 269

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 269 Figure 46 128 A verages used to reduce random noise Realtime Sampling Option Realtime sampling specifies th at t he oscilloscope produce the wa veform display fr om samples collected during one trigger ev ent (t hat is, one acquisition). Use Realtime sampling to capture infrequent trigge ...

  • Agilent Technologies InfiniiVision 6000 Series - page 270

    270 6000 Series Oscilloscope User’s Guide 6 Displaying Data • The oscilloscope produces the wav eform display from samples collected from multiple acquisitions. In t his case, the reconstr uction filter is not used. Realtime Sampling and Oscilloscope Bandwidth T o accurately reproduce a sam pled wav eform, t he sampl e rate should be at least f ...

  • Agilent Technologies InfiniiVision 6000 Series - page 271

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 271 Using Serial Decode Agilent’s hardware accelerated se rial decode options can be licensed on 4-channel or 4+16-ch annel 6000 Series oscilloscopes. Three serial decode licenses are a vailable: • The N5423A (Option LSS) license pro vides the ability t o decode I 2 C (Inter-IC) and SPI ...

  • Agilent Technologies InfiniiVision 6000 Series - page 272

    272 6000 Series Oscilloscope User’s Guide 6 Displaying Data T o decode I 2 C data T o manually control Serial Decode on 6000L models st art t he Remote F r ont Panel (see page 44 ) and select Wa v e f o r m from the Main Menu or press ctrl+A t o ac cess the o scilloscope’s Acquire Menu. 1 Select the I 2 C serial decode mode: a Press the Acquire ...

  • Agilent Technologies InfiniiVision 6000 Series - page 273

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 273 2 Specify the I 2 C signals: a Press the Settings sof tk ey to access t he I 2 C Signals Menu. b Press the SCL so f t ke y , a nd us e the Ent r y kn ob to sele ct th e channel probing the clock sign al. c Press the SDA softk ey , and use the En tr y k nob to sel ect th e channel probing ...

  • Agilent Technologies InfiniiVision 6000 Series - page 274

    274 6000 Series Oscilloscope User’s Guide 6 Displaying Data Y ou can use the Zoom horizont al sweep mode for easier na vigatio n of the acquired dat a. Interpreting De coded I 2 C Data NOTE If the setup does not produce a stable trigger , the I 2 C signal may be slow enough that the oscilloscope is AutoT riggering . Press the Mode/Coupling key , ...

  • Agilent Technologies InfiniiVision 6000 Series - page 275

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 275 • White lines sho w an idle bus. • Blue rect angles show an acti v e bus (insid e a pack et/frame). • In the decoded hexadecimal dat a: • A ddress values appear at t he star t of a frame. • W rite addresses appear in light-blue along with t he “W” character . • Read addre ...

  • Agilent Technologies InfiniiVision 6000 Series - page 276

    276 6000 Series Oscilloscope User’s Guide 6 Displaying Data T o decode SPI data 1 Select the SPI serial decode mode: a Press the Acquire ke y. b Press the Serial Decode sof tk ey. c In the Serial Decode Menu, press the Mode softke y. d Use the Entr y knob (or repeat edly press and release t he Mode sof tk ey) to select the SPI ser ial decode mode ...

  • Agilent Technologies InfiniiVision 6000 Series - page 277

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 277 2 Specify the SPI signals: a Press the Settings sof tk ey to access t he SPI Signals Menu. NOTE If you have a lready set up an SPI trigger , the signals and thei r trigger or threshold levels ha ve already been specifie d, and you can continue on with step 4 . Changing SPI signals in the ...

  • Agilent Technologies InfiniiVision 6000 Series - page 278

    278 6000 Series Oscilloscope User’s Guide 6 Displaying Data b Press the Clock softk ey , and use the En tr y k nob to sele ct the channel probing the clock sig nal. c Press the rising or falling edge sof tke y t o specify the edge that t he clock occurs on. d Press the Data sof tke y , and use t he Entr y knob t o select t he channel probing the ...

  • Agilent Technologies InfiniiVision 6000 Series - page 279

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 279 Y ou can use the Zoom horizont al sweep mode for easier na vigatio n of the acquired dat a. Interpreting Decode d SPI Data • White lines sho w an idle bus. • Blue rect angles show an acti v e bus (insid e a pack et/frame). • The number of clock s in a fram e appears in light-blue a ...

  • Agilent Technologies InfiniiVision 6000 Series - page 280

    280 6000 Series Oscilloscope User’s Guide 6 Displaying Data • Aliased bus values (undersampled or indeter minate) are dra wn in red. • U nknown bus values (undefined or er r or conditions) are dra wn in red. ...

  • Agilent Technologies InfiniiVision 6000 Series - page 281

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 281 T o decode CAN data 1 Co nnec t the C AN si gnal to one of th e osc ill osco pe’s in put channels. 2 Set up the trigger mo de as described in “Triggering the Oscilloscope ” on page 127. Y ou can u se C AN trig ger or another trigger type. 3 Select the CAN serial decode mode: a Pres ...

  • Agilent Technologies InfiniiVision 6000 Series - page 282

    282 6000 Series Oscilloscope User’s Guide 6 Displaying Data 4 Specify the C AN signal: a Press the Settings sof tk ey to access t he CAN Signals Menu. 5 Press the Source s of t key , an d u se t he E nt r y kn ob t o s e le ct t he channel f or the CAN signal. Mak e sure t he trigger or threshold levels are set to the midd le of the CAN signal. 6 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 283

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 283 bus is measured. This controls th e point within the bit’s time where the bit value is captured. 8 Set the trigger level. • F or analog channels, turn t he Trigger Level knob. • F or digital channels, press t he D15 Thru D0 key a n d t h e Thresholds sof tk ey to access t he thresh ...

  • Agilent Technologies InfiniiVision 6000 Series - page 284

    284 6000 Series Oscilloscope User’s Guide 6 Displaying Data Interpreting Decode d CAN Data • Frame ID appears in hex d igits in y ellow . F rames of 11 or 29 bits are automatically detected. • Remote frame (RMT) appears in g reen. • Dat a length code (DLC) appears in blue. • Dat a b yt es appear in hex digits in white for data frames. • ...

  • Agilent Technologies InfiniiVision 6000 Series - page 285

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 285 • Red dots in the decode line indicat e that there is data t hat is not being display ed. Scroll or expand the horizontal scale t o view the inf or mation. • Aliased bus values (undersampled or indeter minate) are dra wn in red. • U nknown bus values (undefined or er r or condition ...

  • Agilent Technologies InfiniiVision 6000 Series - page 286

    286 6000 Series Oscilloscope User’s Guide 6 Displaying Data CAN T otalizer The CAN totalizer pro vides a direct measure of bus quality and ef ficiency. The CAN tot alizer measure s tot al CAN frames, f lagged er ror frames, o verload frames, and bus utilization. The tot alizer is always running (counting frames and calculating percentages) and is ...

  • Agilent Technologies InfiniiVision 6000 Series - page 287

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 287 Overload Frame Count and Percent Error Frame Count and Percent Bus Utilization Percentage Total Fra me Count ...

  • Agilent Technologies InfiniiVision 6000 Series - page 288

    288 6000 Series Oscilloscope User’s Guide 6 Displaying Data T o decode LIN data 1 Select the LIN serial decode mode: a Press the Acquire ke y. b Press the Serial Decode sof tk ey. c In the Serial Decode Menu, press the Mode softke y. d Use the Entr y knob (or repeat edly press and release t he Mode sof tk ey) to select the LIN serial d ecode mode ...

  • Agilent Technologies InfiniiVision 6000 Series - page 289

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 289 3 Specify the LIN signal : a Press the Settings sof tk ey to access t he LIN Signals Menu. LIN signal source LIN baud rate Signal sample point Sync Break selection Trigger level or threshold Currently selected channel LIN trigger Return to previous menu LIN standar d selection Decoded LI ...

  • Agilent Technologies InfiniiVision 6000 Series - page 290

    290 6000 Series Oscilloscope User’s Guide 6 Displaying Data b Press the Source sof tke y , and use the Entr y knob t o select the channel probin g t he LIN signal. c Repeatedly press and release the Baud sof tk ey to specify the L IN s igna l ba ud ra te. d Repeatedly press and release the Smpl Pt sof tk ey to select the sample point. This contro ...

  • Agilent Technologies InfiniiVision 6000 Series - page 291

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 291 g If the decode line does not appear on the d ispla y , press the up -arr o w softk ey to ret urn to th e pre vio us me nu, t he n press the Decode softkey. 5 If the oscilloscope is stopped, press t he Run/Stop ke y t o acquire and decode dat a. Y ou can use the Zoom horizont al sweep mo ...

  • Agilent Technologies InfiniiVision 6000 Series - page 292

    292 6000 Series Oscilloscope User’s Guide 6 Displaying Data Interpreting Decoded LIN Data ...

  • Agilent Technologies InfiniiVision 6000 Series - page 293

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 293 • White traces sho w an id le bus (LIN 1.3 onl y). • Blue bi-lev el trace shows an activ e bus (inside a pack et/frame). • The hexadecimal ID and parity bits (if enabled) appear in yello w . If a parity error is detected the hexadecimal ID and parity bits (if enabled) appear in red ...

  • Agilent Technologies InfiniiVision 6000 Series - page 294

    294 6000 Series Oscilloscope User’s Guide 6 Displaying Data T o decode FlexRay data T o decode FlexRa y dat a, you need a f our -channel 6000 Series mix ed signal oscilloscope, t he N5432A FlexRa y triggering and decode option, the A gilent VPT1000 protocol analyzer , and its MSO communications cable . 1 Set up the oscilloscope and t he VPT1000. ...

  • Agilent Technologies InfiniiVision 6000 Series - page 295

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 295 When the FlexRay mode i s selected, you can use t he Settings softkey to access the VPT1000 Menu for changing the VPT1000 control/operating modes. 4 If the decode line does not appear on the display , press the Decode so f tkey t o t ur n it on . Th e VP T1 000 mus t be co nne ct ed and ...

  • Agilent Technologies InfiniiVision 6000 Series - page 296

    296 6000 Series Oscilloscope User’s Guide 6 Displaying Data Interpreting Decode d FlexRay Frame Data The FlexRay decode displa y sho ws fr ame decoding (bottom ro w) and if the VPT1000 is in t he synchronous monitoring mode, global time-schedule decoding (top ro w). Frame Decoding (bottom ro w of deco de displa y) • Frame type (NORM, SYNC, SUP ...

  • Agilent Technologies InfiniiVision 6000 Series - page 297

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 297 Interpreting Decoded FlexRay T ime Data Global T i me-Schedule Decoding (top ro w of decode display) • Segment type: st atic = SS in or ange, dynamic = DS in green, Symbol in yello w , Id le = NIT (network idle time) in white. • Segment number: decimal digits in orange (st atic) or g ...

  • Agilent Technologies InfiniiVision 6000 Series - page 298

    298 6000 Series Oscilloscope User’s Guide 6 Displaying Data FlexRay T otalizer The FlexRa y tot alizer consists of cou nters t hat pro vide a direct measure of bus quality and eff iciency. The tot alizer is r unning, cou nting frames and calculating percentage s, ev en when t he oscilloscope is st opped (not acquiring dat a). The tot alizer appea ...

  • Agilent Technologies InfiniiVision 6000 Series - page 299

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 299 Counters • The FRAMES count er giv es a real -ti me count of all received frames. • The NULL counte r giv es t he number and pe rc e ntage of nu ll frames. • The SYNC counter gives t he number and percent age of sync frames. Null Frame Count and Percent Total Frame Count Sync Frame ...

  • Agilent Technologies InfiniiVision 6000 Series - page 300

    300 6000 Series Oscilloscope User’s Guide 6 Displaying Data T o decode UART/RS232 data 1 Select the U ART/RS232 serial decode mode: a Press the Acquire ke y. b Press the Serial Decode sof tk ey. c In the Serial Decode Menu, press the Mode softke y. d Use the Entr y knob (or repeat edly press and release t he Mode sof tk ey) to select t he UART/RS ...

  • Agilent Technologies InfiniiVision 6000 Series - page 301

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 301 2 Specify the UART/RS232 signals: a Press the Settings sof tk ey to access t he U ART/RS232 decode settings menu. b Press the Signals sof tk ey , and select t he oscilloscope channels that you ha ve connected to t he Rx and Tx signals. NOTE Changing UART/RS232 signals in the Serial Decod ...

  • Agilent Technologies InfiniiVision 6000 Series - page 302

    302 6000 Series Oscilloscope User’s Guide 6 Displaying Data See the UART/RS23 2 tr iggering section on page page 199 f o r detailed instr uctions. 3 Press the Retur n to previous menu (up arro w) sof tke y. 4 Press the Bus Config sof tk ey. a# B i t s : Set the number of bits in t he U ART/RS232 wor ds t o match your targ et system (selec table f ...

  • Agilent Technologies InfiniiVision 6000 Series - page 303

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 303 7 Optional: Press the Framing softke y and select a value. In the decode display the chosen valu e will b e display ed in l ight blue. Ho wev er , if a parity er ror occurs the dat a will be display ed in red. 8 Mak e sure the trigger or threshold lev els are set to the middle of the sig ...

  • Agilent Technologies InfiniiVision 6000 Series - page 304

    304 6000 Series Oscilloscope User’s Guide 6 Displaying Data Interpreting Decoded UART/RS232 Data • An idle bus is shown in white. • An active bus is sho wn in dark blue, wit h v er tical lines designating the st ar t and end of each data wor d. • When using 5-8 bit formats, the decoded dat a is display ed in white (in binar y , hex, or ASCI ...

  • Agilent Technologies InfiniiVision 6000 Series - page 305

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 305 • An unkno wn (undef ined) bus is sho wn in red. • A parity error will cause th e associated dat a w ord to be sho wn in red, whic h includes the 5-8 dat a bits and the optional 9t h bit. ...

  • Agilent Technologies InfiniiVision 6000 Series - page 306

    306 6000 Series Oscilloscope User’s Guide 6 Displaying Data UART/RS232 T otalizer The U ART/RS232 tot alizer consists of coun ters that pro vide a direct measure of bus quali ty and eff icienc y. The tot alizer appears on screen whenev er UART/RS232 Decode is ON in the Serial Decode Menu. The tot alizer is r unning, counti ng frames and calculati ...

  • Agilent Technologies InfiniiVision 6000 Series - page 307

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 307 T o reduce the random noise on a signal If the signal you are pr obing is noisy , y ou can set up t he oscilloscope to reduce t he noise on the display ed wav eform. First, you stabilize t he display ed wavef orm by removing the noise from th e trigger pat h. Second, you reduce t he nois ...

  • Agilent Technologies InfiniiVision 6000 Series - page 308

    308 6000 Series Oscilloscope User’s Guide 6 Displaying Data LF Reject Lo w-frequency reject (LF reject) adds a high-pass filt er with the 3-dB point at 50 kHz. LF reject remo ves lo w-frequency signals, such as po wer line noise, from the trigger path. • Press Mode/Coupling & Coupling & LF Reject . Noise rejection Noise reject increases ...

  • Agilent Technologies InfiniiVision 6000 Series - page 309

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 309 T o capture glitches or narrow puls es with peak detect and infinite persistence A glit ch is a rapid change in the wav eform t hat is usuall y narro w as compared t o the wa veform. P eak det ect mode can be used to mor e easily vie w g litches or nar ro w pulses . In peak detect mode, ...

  • Agilent Technologies InfiniiVision 6000 Series - page 310

    310 6000 Series Oscilloscope User’s Guide 6 Displaying Data Figure 48 15 ns Narrow Pulse, 20 ms /d iv , Pe ak Detect Mode Using peak detect mode to find a glitch 1 Connect a signal to the oscilloscope and obt ain a stable displa y. 2 T o f ind the g litch, press t he Acquire k ey , then , pr ess th e Acq Mode sof tk ey until Peak Detect is select ...

  • Agilent Technologies InfiniiVision 6000 Series - page 311

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 311 4 Characterize t he glit ch with zoom sweep: a Press the Menu/Zoom k ey , then pres s the Zoom so ftkey. b T o obt ain a better reso lution of the g lit ch, expand t he time base. c Use the horizont al position knob ( ) to pan t hrough the wa vef orm to s et the exp ande d porti on of th ...

  • Agilent Technologies InfiniiVision 6000 Series - page 312

    312 6000 Series Oscilloscope User’s Guide 6 Displaying Data How AutoScale W orks A utoS cale autom ati call y co nfigu res th e osc ill osco pe to b est displa y t he input sign als b y analyzing an y wav e f or ms present at each channel and at t he exter nal trigger input. This includes th e digit al channe ls on MSO model s. A u toScale finds, ...

  • Agilent Technologies InfiniiVision 6000 Series - page 313

    Displaying Data 6 6000 Series Oscilloscope User’s Guide 313 Specifying the Channels Displayed After AutoScale The Channels softke y selection determines which channels will be displa yed on subsequent AutoScales. • All Channels — The next time y ou press AutoScale , all channels tha t meet the r equi reme nts of A utoS cale wil l be d ispl a ...

  • Agilent Technologies InfiniiVision 6000 Series - page 314

    314 6000 Series Oscilloscope User’s Guide 6 Displaying Data ...

  • Agilent Technologies InfiniiVision 6000 Series - page 315

    315 Agilent T echnologies Agilent 6000 Series Oscilloscope User’s Guide 7 Saving and Printing Data Printing the oscilloscope’ s display 316 Supported Printers 318 Saving oscilloscope data 320 Selecting a destination for your saved data 321 Selecting a file n ame 322 W aveform T race and Oscilloscope Setup 324 Display Image and W aveform Data Fi ...

  • Agilent Technologies InfiniiVision 6000 Series - page 316

    316 6000 Series Oscilloscope User’s Guide 7 Saving and Printing Data Printing the oscilloscope’ s display T o print t he oscilloscope’s displa y: 1 Connect a USB printer to either t he USB por t on the front panel or the rect angular USB host por t on t he rear panel. A list of support ed printers is on page 318 . 2 Press the Print key ( la b ...

  • Agilent Technologies InfiniiVision 6000 Series - page 317

    Saving and Printing Data 7 6000 Series Oscilloscope User’s Guide 317 Selecting print options Press the Options softk ey to cha nge the f ollo wi ng op tio ns: • Factors — Select Factors if y ou want the oscilloscope scale factors t o be included on yo ur printout. Oscilloscope scale factors include vertical, horizont al, trigger , acquisition ...

  • Agilent Technologies InfiniiVision 6000 Series - page 318

    318 6000 Series Oscilloscope User’s Guide 7 Saving and Printing Data Supported Printers The follo wi ng HP printers, available in store s at the time t his manual was written, hav e been t ested and found to be compatible with the Inf iniiV ision 6000 Series oscilloscopes. Visit www .agilent.com/f ind/mso6000 and select T echnical Support , then ...

  • Agilent Technologies InfiniiVision 6000 Series - page 319

    Saving and Printing Data 7 6000 Series Oscilloscope User’s Guide 319 Deskjet 980 Deskjet 990C Deskjet 995 Deskjet 1220C & 1125C Deskjet 38 16 & 3820 Deskjet 55 50 & 5551 Deskjet 61 22 & 6127 Deskjet 56 00 & 5100 & 5800 Deskjet 65 40 & 6520 Deskjet 5740 Deskjet 6840 Deskjet 37 40 & 3840 Deskjet CP 1160 & CP1700 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 320

    320 6000 Series Oscilloscope User’s Guide 7 Saving and Printing Data Saving oscilloscope data Here are a f ew points about sa v ing oscilloscope dat a: • Y ou can sav e a wav eform trace and recall it later . The recalled trace appears in cyan (blue). • Y ou can s a ve oscilloscope setu p parameters and recall t hem later . The setup f ile st ...

  • Agilent Technologies InfiniiVision 6000 Series - page 321

    Saving and Printing Data 7 6000 Series Oscilloscope User’s Guide 321 Selecting a destinatio n for your saved data Press Save/Recall → Save to access t he Sa ve menu and select a destination for sa ving your data. Press to go/Location/Save to softkey (Using the oscilloscope’ s File Explorer) The second sof tk ey from the left in the Sav e me n ...

  • Agilent Technologies InfiniiVision 6000 Series - page 322

    322 6000 Series Oscilloscope User’s Guide 7 Saving and Printing Data If one or more USB storage devic es are connect ed to the os cill osco pe, yo u can na viga te to the USB d evi ce us ing the sam e method. The follo wing display im age sho ws an image ready to be sa ved to a subfolder called “Rise time” on a USB de vice. Push the E ntry kn ...

  • Agilent Technologies InfiniiVision 6000 Series - page 323

    Saving and Printing Data 7 6000 Series Oscilloscope User’s Guide 323 Spell softkey and press the Enter so f tk ey to cre ate the n ew fi le name. 3 Y ou can press t he Enter so f t ke y o r t h e En t r y kn o b t o mov e t h e cursor f or ward within t he file name. 4 Y ou can press t he Delete Character softk ey to del ete th e cu r re nt c har ...

  • Agilent Technologies InfiniiVision 6000 Series - page 324

    324 6000 Series Oscilloscope User’s Guide 7 Saving and Printing Data W aveform T r ace and Oscilloscope Setup When the Tr a c e & S e t u p option is selected fr om the Format softkey , bot h wav eform trace and oscilloscope setup are sa ved to th e USB d riv e o r the o scil los cope ’s in ternal mem or y. After sa ving, you can choose to ...

  • Agilent Technologies InfiniiVision 6000 Series - page 325

    Saving and Printing Data 7 6000 Series Oscilloscope User’s Guide 325 • ASCII XY data file - This creates a f ile of comma-separated variables for each displa yed channel. If the oscilloscope acquisition is stopped, t hen data records great er than 1000 points can be writte n. This f or mat is also suit able f or spreadsheets. • BIN data file ...

  • Agilent Technologies InfiniiVision 6000 Series - page 326

    326 6000 Series Oscilloscope User’s Guide 7 Saving and Printing Data The Invert Graticule Colors option can be used t o reduce the amount of black ink it takes to print oscilloscope images by changing the black back ground to white. Invert Graticule Colors is the default mode. Invert Graticule Colors is a vailable when the BMP and PNG formats are ...

  • Agilent Technologies InfiniiVision 6000 Series - page 327

    Saving and Printing Data 7 6000 Series Oscilloscope User’s Guide 327 The Length control will per f or m a “1 of n” decimation of t he dat a when necessar y. F or example: if the Length is set t o 1000, and yo u are displaying a record that is 5000 data points in length, four of each five data po ints will be decimat ed, creating an output fil ...

  • Agilent Technologies InfiniiVision 6000 Series - page 328

    328 6000 Series Oscilloscope User’s Guide 7 Saving and Printing Data T o recall waveform trace and/or oscilloscope setup A recalled trace is typically us ed for a quick com p arison of measurement results. F or example, y ou might sav e a trace of a wa veform to use as a reference, then mak e a similar measurement on a t est system and then recal ...

  • Agilent Technologies InfiniiVision 6000 Series - page 329

    Saving and Printing Data 7 6000 Series Oscilloscope User’s Guide 329 When the USB storage device is connected to the oscilloscope’s front or rear USB host port, a smal l four -color circle icon may be display ed brief ly as the USB device is read. Y ou do not need t o “eject” the USB device befo re removing it. Simpl y ensu re that any file ...

  • Agilent Technologies InfiniiVision 6000 Series - page 330

    330 6000 Series Oscilloscope User’s Guide 7 Saving and Printing Data T o use the file explorer Files can be loaded and delet ed using the f ile explorer . Y ou can c reate direct ories on a USB mass st orage device using your PC or other instr ument. Y ou can na vigat e to any director y on the USB device by rotating th e Entr y knob and pressing ...

  • Agilent Technologies InfiniiVision 6000 Series - page 331

    Saving and Printing Data 7 6000 Series Oscilloscope User’s Guide 331 Secure Environment Mode Option Secure environment mode is com p liant t o N a tional Industrial Security Program Operating Manual (NISPOM) Chapter 8 requirements. Secure environment mode is ca lled option SEC when it is or der ed with th e os ci llo sc ope . W h en adding secure ...

  • Agilent Technologies InfiniiVision 6000 Series - page 332

    332 6000 Series Oscilloscope User’s Guide 7 Saving and Printing Data Ta b l e 1 8 Ordering the Secure En vironment Mode Option Ordering the Secure Environment Mode Option New oscilloscope purchase ... Order Option SEC. After oscilloscope purch ase, if you have not saved confidential trace or setups on the oscillos cope... Order N5427A and return ...

  • Agilent Technologies InfiniiVision 6000 Series - page 333

    333 Agilent T echnologies Agilent 6000 Series Oscilloscope User’s Guide 8 Reference Upgrading to an MSO or adding memory depth 334 Software and firmware updates 334 T o set up the I/O p ort 335 Using the 10 MHz re ference clock 336 T o supply a sample clock to the oscilloscope 336 T o synchroniz e the timebas e of two or more instruments 338 T o ...

  • Agilent Technologies InfiniiVision 6000 Series - page 334

    334 6000 Series Oscilloscope User’s Guide 8 Reference Upgrading to an MSO or adding memory depth A license can be inst alled to acti vate t he digital channels of an oscilloscope that was not originally ordered as a mix ed-signal oscilloscope (MSO). This incl udes 6000A Series and 6000L Series oscilloscopes. A mix ed signal oscilloscope has analo ...

  • Agilent Technologies InfiniiVision 6000 Series - page 335

    Reference 8 6000 Series Oscilloscope User’s Guide 335 T o set up the I/O port The oscilloscope can be control led via GPIB, LAN, or USB. The oscilloscope’s I/O confi gurat ion, including i ts IP address and hostname, can be view ed by pressing Utility & I/O . T o change the I/O contro ller settings, press t he Configure softkey , and choose ...

  • Agilent Technologies InfiniiVision 6000 Series - page 336

    336 6000 Series Oscilloscope User’s Guide 8 Reference Using the 10 MHz reference clock The 10 MHz REF BNC connector on the rear panel is pro vided so you c an : • Supply a more accurate sample clock signal to the oscilloscope, or • Synchronize the timebase of tw o or mor e instruments. Sample clock and freq uency counte r accu racy The oscill ...

  • Agilent Technologies InfiniiVision 6000 Series - page 337

    Reference 8 6000 Series Oscilloscope User’s Guide 337 2 Press Utility & Options & Rear Panel & Ref Signal . 3 Use the Entr y Knob and the Ref Signal sof tk ey to select 10 MHz input . A black lock ed padlock icon will appear at t he top of t he displa y. If the exter nally supplied sample clock varies great er than 0.5% from 10 MHz a ...

  • Agilent Technologies InfiniiVision 6000 Series - page 338

    338 6000 Series Oscilloscope User’s Guide 8 Reference T o synchronize the timebase of two or more instruments The oscilloscope can output it’s 10 MHz system clock for the purpose of synchronization with ot her instr uments. 1 Connect a BNC cable to the BNC connector labeled 10 MHz REF on the rear panel of th e oscilloscope. 2 Connect the other ...

  • Agilent Technologies InfiniiVision 6000 Series - page 339

    Reference 8 6000 Series Oscilloscope User’s Guide 339 T o return the instrument Before shipping the oscilloscope to Agilen t T echnologies, contact your nearest Agilent Techno logies sales or service off ice f or additional det ails. Information on contacting A gilent T echnologies can be f o und at www .agilent. com/find/con tactus . 1 W rite th ...

  • Agilent Technologies InfiniiVision 6000 Series - page 340

    340 6000 Series Oscilloscope User’s Guide 8 Reference Digital channel signal fidelity: Probe impedance and grounding Y ou may encount er problems when using t he mixed-signal oscilloscope that are relat ed to probing. These pr oblems fall into two categories: probe loading and probe grounding. Probe loading problems generally af f ect t he circui ...

  • Agilent Technologies InfiniiVision 6000 Series - page 341

    Reference 8 6000 Series Oscilloscope User’s Guide 341 Figure 49 DC and Low -Frequency Probe Equivalent Circuit Figure 50 High -Frequency Probe Equivalent Circuit The impedance plots f or t he tw o mo dels are sho wn in t hese figu res. By comparing the two plots, y ou can see that bot h the series tip resist or and the cable’s characteristic im ...

  • Agilent Technologies InfiniiVision 6000 Series - page 342

    342 6000 Series Oscilloscope User’s Guide 8 Reference Figure 51 Impedance versus Frequency fo r Both Probe Circuit Models The logic pr obes are represented by the high-frequenc y circuit model shown abo ve. They are designed to pro vi de as much series tip resist ance as possible. Stray tip capacitance t o ground is minimized b y the proper mech ...

  • Agilent Technologies InfiniiVision 6000 Series - page 343

    Reference 8 6000 Series Oscilloscope User’s Guide 343 Sharing one probe ground with man y probes for ces all t he cu r re nt th at f lo ws in to ea ch pr ob e to ret urn th rou gh the same common g round inductance of the probe whose ground return is used. The result is inc reased current ( di ) in the above equation, and, depending on the transi ...

  • Agilent Technologies InfiniiVision 6000 Series - page 344

    344 6000 Series Oscilloscope User’s Guide 8 Reference Best Probing Practices Because of t he variables L , di , and dt , you ma y be unsure ho w much margin is available in your measurement setup. The f ollowing are guidelines f or good probing practices: • The ground lead from each digital channel group (D15–D8 and D7–D0) should be attache ...

  • Agilent Technologies InfiniiVision 6000 Series - page 345

    Reference 8 6000 Series Oscilloscope User’s Guide 345 T o replace digital probe leads If y o u need to remov e a probe lead from the cable, inser t a paper clip or other small poin te d o bjec t into the si de o f the cable assembly , and push t o release the latch while pulling out the probe lead. F or ot her replacement parts, consult t he Infi ...

  • Agilent Technologies InfiniiVision 6000 Series - page 346

    346 6000 Series Oscilloscope User’s Guide 8 Reference Binary Data (.bin) The binar y dat a f or mat stores wav eform dat a in binar y f or mat and pro vides dat a headers that describe that dat a. Because the dat a is in binar y format, the size of t he file is appro ximately 5 times smaller than the XYPairs format. If more t han one source is on ...

  • Agilent Technologies InfiniiVision 6000 Series - page 347

    Reference 8 6000 Series Oscilloscope User’s Guide 347 File Size A 3 2-bi t in teger that i s the n umbe r of byt es tha t are in the file. Number of W aveforms A 3 2-bi t inte ger that i s the n umbe r of wa veforms that are st ored in the f ile. Wa v e f o r m H e a d e r It is possible to s tore more t han one wav eform in t he file, and each w ...

  • Agilent Technologies InfiniiVision 6000 Series - page 348

    348 6000 Series Oscilloscope User’s Guide 8 Reference X Display Range A 32-bit f loat that is t he X -axis duration of t he wa veform that is display ed. For time domain wa vef o rms, it is the duration of time across th e disp la y. If t he value is zer o then no dat a has been acquired. X Display Origin A 64-bit double that is t he X-axis value ...

  • Agilent Technologies InfiniiVision 6000 Series - page 349

    Reference 8 6000 Series Oscilloscope User’s Guide 349 Tim e A16-bit character ar ra y , left blank in t he 6000 Series oscilloscope. Frame A 2 4 by te ch arac ter a rra y that is th e mod el n umbe r an d serial number of t he oscilloscope in the format of: MODEL#:SERIAL#. Wa v e f o r m L a b e l A 16 byte character array that cont ains t he lab ...

  • Agilent Technologies InfiniiVision 6000 Series - page 350

    350 6000 Series Oscilloscope User’s Guide 8 Reference Wa v e f o r m D a t a H e a d e r A wa veform ma y have more than one data set. Each wavef or m dat a set will ha ve a wa vef or m data header . The wavef orm dat a header consists of inf or mation about the wavef orm data set. This header is st ored immediately before the dat a set. W avefor ...

  • Agilent Technologies InfiniiVision 6000 Series - page 351

    Reference 8 6000 Series Oscilloscope User’s Guide 351 Examples of Binary Files Single Acquisition Mult iple Analog Channels The follo wing picture shows a binar y file of a sing le acquisition with multiple analog channels. File Header 12 bytes Number of W aveforms = N Number of W aveform Buffers = 1 Buffer T ype = 1 (floating point) Bytes per Po ...

  • Agilent Technologies InfiniiVision 6000 Series - page 352

    352 6000 Series Oscilloscope User’s Guide 8 Reference Single Acquisition All Pods Logic Channels The follo wing picture shows a binar y file of a sing le acquisition with all pods for the logic channels sav ed. File Header 12 bytes W aveform Header 2 140 bytes W aveform Data Header 1 12 bytes Pod 1 Timing Data buffer size W aveform Data Header 2 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 353

    Reference 8 6000 Series Oscilloscope User’s Guide 353 Minimum and Maximum V a lues in CSV Files If you are running a Quick Me asurement Minimum or Maximum measurement, t he minimum an d maximum values shown in the Quick Measurement displa y may not appear in the CSV f ile. Explanation: When the osci lloscope’s sample ra te is 4 GSa/s, a sam ple ...

  • Agilent Technologies InfiniiVision 6000 Series - page 354

    354 6000 Series Oscilloscope User’s Guide 8 Reference ...

  • Agilent Technologies InfiniiVision 6000 Series - page 355

    355 Agilent T echnologies Agilent 6000 Series Oscilloscope User’s Guide 9 Power and Environmental Conditions Power Requirements 356 Measurement Category 357 Environmental Conditions 359 Specifica tions 360 Acknowledgements 360 Contact us 361 This chapter describes t he po wer requirements and environment al conditions appropriate for the A gilent ...

  • Agilent Technologies InfiniiVision 6000 Series - page 356

    356 6000 Series Oscilloscope User’s Guide 9 Power and Environmental Conditions Power Requirements Line voltage range ~ Line 120 W max, 96-144 V/48-440 Hz, 192-288 V/48-66 Hz, automatic selection Line frequency 50/60 Hz, 100-240 V A C; 440 Hz, 100-132 V A C Power usage 110 W max ...

  • Agilent Technologies InfiniiVision 6000 Series - page 357

    Power and Environmental Conditions 9 6000 Series Oscilloscope User’s Guide 357 Measurement Category Measurement Category The 6000 Series oscilloscope is intended t o be used f or measurements in Measurement Categor y I. Measurement Category Defini tions Measurement categor y I is f or measurements performed on circuits not directl y connect ed to ...

  • Agilent Technologies InfiniiVision 6000 Series - page 358

    358 6000 Series Oscilloscope User’s Guide 9 Power and Environmental Conditions T ransient Withstand Capability CAUTION Maximum input voltage for analog inputs CA T I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kV pk CA T II 100 Vrms, 400 V pk with N2863A 10:1 probe: CA T I 600 V , CA T II 300 V (DC + peak AC) with 10073C 10:1 probe: CA T I 500 V ...

  • Agilent Technologies InfiniiVision 6000 Series - page 359

    Power and Environmental Conditions 9 6000 Series Oscilloscope User’s Guide 359 Environmental Conditions Environment Indoor use only. Ambient temperature Operating –10 °C to +55 °C; non-operating –51 °C to +71 °C Humidity Operating 95% RH at 40 °C f or 24 hr; non-operating 90% RH at 65 °C for 24 hr Altitude Operating to 4,570 m (15,000 f ...

  • Agilent Technologies InfiniiVision 6000 Series - page 360

    360 6000 Series Oscilloscope User’s Guide 9 Power and Environmental Conditions Specifications Please see the Inf iniiVision 6000 Series Oscilloscopes Data Sheet f or complete, up-to-date specifications and characteristics. T o download a cop y of the d ata sheet please visit: www .agilent.com/f ind/mso6000 and select Libr ary , then sele ct Speci ...

  • Agilent Technologies InfiniiVision 6000 Series - page 361

    9 6000 Series Oscilloscope User’s Guide 361 Contact us Americas Canada (8 77) 894- 4414 Latin Ameri ca 305 269 7500 United States (800) 829-4444 Asia Pacifi c Australia 1 800 629 485 China 800 810 0189 Hong Kong 80 0 938 693 India 1 800 11 2 929 Japan 81 4 26 56 7832 Korea 080 7 69 0800 Malaysia 1 800 888 848 Singapore 1 80 0 375 8100 T aiwan 08 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 362

    362 6000 Series Oscilloscope User’s Guide 9 ...

  • Agilent Technologies InfiniiVision 6000 Series - page 363

    6000 Series Oscilloscopes User’s Guide 363 Index Symbols (-)Width measurement , 246 (+)Width measurement , 246 Numerics 1*2 math function , 215 1-2 math function , 21 7 232 , 109 6000L , 8 , 21 A about oscilloscope , 108 AC adapter , 36 AC channel coupl ing , 85 accessories , 22 , 26 , 27 acquire , 268 acquisition memory , 130 acquisition mode , ...

  • Agilent Technologies InfiniiVision 6000 Series - page 364

    364 6000 Series Oscilloscopes User’s Guide Index channel analog , 83 bandwidth limi t , 86 coupling , 85 invert , 86 on/off keys , 70 positio n , 84 probe units , 87 skew , 87 vernier , 84 vertical sensiti vity , 84 channel pair , 270 charging indic ator , 34 , 36 choosing values , 66 cleaning , 339 clear display , 261 , 310 clock , 102 CMOS thre ...

  • Agilent Technologies InfiniiVision 6000 Series - page 365

    6000 Series Oscilloscopes User’s Guide 365 Index file keys , 70 file name, new , 322 firmware updates , 334 firmware version information , 43 Flat top window , 226 FlexRay frame counter , 298 FlexRay serial decode , 294 FlexRay totalizer , 298 FlexRay trigger , 155 format wavefo rm , 324 FPG , 109 frame trigger , I2C , 16 7 , 168 Frequency measur ...

  • Agilent Technologies InfiniiVision 6000 Series - page 366

    366 6000 Series Oscilloscopes User’s Guide Index Maximum measurement , 251 maximum sample rate , 270 measure keys , 72 measurement category definition s , 357 measurement definitions , 244 measurement line , 75 measurement thresholds , 241 measurements , 96 , 315 MegaZoom III , 4 mem2M license , 109 mem8M license , 109 memory depth , 78 upgrade , ...

  • Agilent Technologies InfiniiVision 6000 Series - page 367

    6000 Series Oscilloscopes User’s Guide 367 Index replacement parts , 34 5 reset LAN , 40 restart condition, I2C trigger , 166 return instrument for service , 339 Rise time measurement , 246 RMS measurement , 252 roll mode , 93 run controls , 71 Run/Stop key , 77 runt pulses , 245 S sample rate , 5 , 266 , 270 current rate displayed , 88 save brow ...

  • Agilent Technologies InfiniiVision 6000 Series - page 368

    368 6000 Series Oscilloscopes User’s Guide Index trigger type , 139 CAN , 148 duration , 152 edge , 140 FlexRay , 155 glitch , 142 hex bus , 14 7 I2C , 164 LIN , 172 Nth edge burst , 170 pattern , 145 pulse width , 142 sequence , 175 slope , 140 SPI , 182 TV , 187 UART/RS232 , 199 USB , 204 triggers , 206 TTL threshold , 121 turn channel on , 70 ...

Manufacturer Agilent Technologies Category Respiratory Product

Documents that we receive from a manufacturer of a Agilent Technologies InfiniiVision 6000 Series can be divided into several groups. They are, among others:
- Agilent Technologies technical drawings
- InfiniiVision 6000 Series manuals
- Agilent Technologies product data sheets
- information booklets
- or energy labels Agilent Technologies InfiniiVision 6000 Series
All of them are important, but the most important information from the point of view of use of the device are in the user manual Agilent Technologies InfiniiVision 6000 Series.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Agilent Technologies InfiniiVision 6000 Series, service manual, brief instructions and user manuals Agilent Technologies InfiniiVision 6000 Series. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Agilent Technologies InfiniiVision 6000 Series.

A complete manual for the device Agilent Technologies InfiniiVision 6000 Series, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Agilent Technologies InfiniiVision 6000 Series by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Agilent Technologies InfiniiVision 6000 Series.

A complete Agilent Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Agilent Technologies InfiniiVision 6000 Series - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Agilent Technologies InfiniiVision 6000 Series, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Agilent Technologies InfiniiVision 6000 Series, that we can find in the current document
3. Tips how to use the basic functions of the device Agilent Technologies InfiniiVision 6000 Series - which should help us in our first steps of using Agilent Technologies InfiniiVision 6000 Series
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Agilent Technologies InfiniiVision 6000 Series
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Agilent Technologies InfiniiVision 6000 Series in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Agilent Technologies InfiniiVision 6000 Series?

Use the form below

If you did not solve your problem by using a manual Agilent Technologies InfiniiVision 6000 Series, ask a question using the form below. If a user had a similar problem with Agilent Technologies InfiniiVision 6000 Series it is likely that he will want to share the way to solve it.

Copy the text from the picture