    Agilent T echnologies 54600-Series Oscilloscopes Data Sheet Multiple configurations to meet your needs If you w ork with bot h analog and digital components, Agilent T echnologies 54600-Series oscilloscopes can help you easil y see more of what's going on in your designs. The unique 2 + 16-channel mix ed signal oscillo- scope (MSO) models and ...

  • Agilent Technologies 54600-Series - page 2

    2 Selection Guide Figure 1. 2 + 16-channel mixed signal oscilloscope (MSO) family shown with 2- and 4-channel models. Selection Guide Model Bandwidth Maximum Sample Rate Maximum Memory* Channels 54621A 60 MHz 200 MSa/s 4 MB 2 54621D 60 MHz 200 MSa/s 4 MB 2+16 54622A 100 MHz 200 MSa/s 4 MB 2 54622D 100 MHz 200 MSa/s 4 MB 2+16 54624A 100 MHz 200 MSa/ ...

  • Agilent Technologies 54600-Series - page 3

    3 Figure 2. 2 + 16-channel mixed signal oscilloscope (MSO) allows you to view analog and digital content on one instrument. Mixed-signal scopes (models 54621D, 54622D, 54641D, and 54642D) The mix ed-signal oscilloscopes (MSO), with 2 analog channels and 16 digital channels, uniquely combine the det ailed signal analy- sis of a scope with t he multi ...

  • Agilent Technologies 54600-Series - page 4

    4 Affordable and Responsive MegaZoom deep memory With 4 MB t o 8 MB of MegaZoom deep memor y , 54600-Series scopes give y ou deep-memor y capture without t he sluggish response and complex operation you’v e had to t olerate wit h other deep-memor y scopes. And unlike the alter natives, MegaZoom deep memor y is not a special mode. That means it’ ...

  • Agilent Technologies 54600-Series - page 5

    5 Affordable and Responsive (continued) Revolutionary high-definition dis- play helps you see details Combine MegaZoom deep memor y with a patent ed high-def inition display system, and y ou will see subtle details t hat most scopes w on’t show y ou. The MegaZoom deep memor y is mapped into 32 lev els of int ensity on a display that has twice t h ...

  • Agilent Technologies 54600-Series - page 6

    6 Deep memory transfer over the bus Transfer all of y our dat a ov er t he bus, ev en when using deep memor y. T ypical transfer time is <70 seconds for 2 MB of data o ver GPIB. The 54640-Series requires soft- ware revision 1.0 or later . The 54620-Series requires software revision 1.5 or later . The syst em software is st ored in FL ASH ROM tha ...

  • Agilent Technologies 54600-Series - page 7

    7 N2758A CAN T rigger Module • T rigger on CAN 2.0A/B message frames with user specified IDs and/or data • T rigger on Error frames • Differential CAN • Acknowledge On/Off • Built In QuickHelp • Remote Control via GPIB/RS232 • Compatible with 54621D, 54622D, 54641D, 54642D The N2758A CAN trigger module extends your Mix ed Signal Oscil ...

  • Agilent Technologies 54600-Series - page 8

    8 T riggering Flexible T riggering With mixed analog and digital designs, sometimes it is hard to trace an anomaly back to its root cause unless you can trigger on it and correlat e it with anot her signal. With t he 54600-Series scopes, triggering is no longer a hassle. They come with f lexible triggering capabilities across all channels so you ca ...

  • Agilent Technologies 54600-Series - page 9

    9 T riggering (continued) I 2 C and SPI T riggering Don’t spend your time sorting through communication frames to find t he one of interest. Let Agilent set up an Int er -Int egrat ed Circuit (I 2 C) or Serial P eripheral Inter face (SPI) trigger to sif t through the frames for y ou. And like the C AN, LIN, and USB trig- gers, I 2 C and SPI come ...

  • Agilent Technologies 54600-Series - page 10

    10 MegaZoom deep memor y helps you determine ho w your signals are impacting each other . Wit h shallo w memor y scopes, you ha ve to choose whet her you look at a slo w analog signal or fast digit al content. With up t o 8 MB deep memor y , you don’t ha ve to choose – capture all of your data at once. Revolutionary high-def inition display re ...

  • Agilent Technologies 54600-Series - page 11

    11 Quickly pan and zoom f or analysis with MegaZoom’s inst ant response and optimum resolution. Autoscale lets y ou quickly display an y active signals, automatically setting the vertical, horizontal and trigger controls for the best displa y , while opti- mizing memor y. QuickMeas gives y ou any three automated measurements wit h the push of a b ...

  • Agilent Technologies 54600-Series - page 12

    12 Probes T o get t he most out of your scope, you need the right probes and accessories for y our par ticular application. That's why Agilent T echnologies of fers a com plet e family of inno vative probes and 54600-Series scopes. F or more comprehensiv e information, please see the A gilent 54600-Series Oscilloscopes Probes and A ccessories ...

  • Agilent Technologies 54600-Series - page 13

    13 Performance Characteristics Acquisition: Analog Channels Max Sample Rate 54621A/D, 54622A/D, 54624A: 200 MSa/s 54641A/D, 54642A/D: 2 GSa/sec interleaved, 1 GSa/sec each channel Max Memory Depth 54621A/D, 54622A/D, 54624A: 4 MB interleaved, 2 MB each channel 54641A/D, 54642A/D: 8 MB interleaved, 4 MB each channel V ertical Resolution 8 bits Peak ...

  • Agilent Technologies 54600-Series - page 14

    14 Performance Characteristics (continued) V ertical System: Analog Channels (continued) Range 1,2 54621A/D, 54622A/D, 54624A: 1 mV/div to 5 V/div 54641A/D, 54642A/D: 2 mV/div to 5 V/div Maximum Input CA T I 300 Vrms, 400 V pk, CA T II 100 Vrms, 400 Vpk With 10073C/10074C 10:1 probe: CA T I 500 Vpk, CA T II 400 Vpk 5 Vrms with 50 Ω input Offset R ...

  • Agilent Technologies 54600-Series - page 15

    15 Performance Characteristics (continued) V ertical System: Digital Channels (54621D, 54622D, 54641D, and 54642D only) Number of Channels 16 Digital – labeled D15 - D0 Threshold Groupings Pod 1: D7 - D0 Pod 2: D15 - D8 Threshold Selections TTL, CMOS, ECL, user-definable (selectable by pod) User-Defined Threshold Range ±8.0 V in 10 mV increments ...

  • Agilent Technologies 54600-Series - page 16

    16 Performance Characteristics (continued) Horizontal (continued) Digital Delta-t Accuracy 54621A/D, 54622A/D, 54624A: (non- V ernier settings) Same Channel: ±0.01% reading ±0.1% screen width ±(1 digital sample period, 2.5 or 5 ns based on sample rate of 200/400 MSa/s) Channel-to-Channel: ±0.01% reading ±0.1% screen width ±(1 digital sample p ...

  • Agilent Technologies 54600-Series - page 17

    17 Performance Characteristics (continued) T rigger System (continued) I 2 C T rigger on I 2 C (Inter-IC bus) serial protocol at a start/stop condition or user defined frame with address and/or data values. Also trigger on Missing Acknowledge, Restart, EEPROM read, and 10 bit write. SPI T rigger on SPI (Serial Protocol Interface) data pattern durin ...

  • Agilent Technologies 54600-Series - page 18

    18 Performance Characteristics (continued) Display System Display 7-inch raster monochrome CRT Throughput of Analog Channels 25 million vectors/sec per channel with 32 levels of intensity Resolution 255 vertical by 1000 horizontal points (waveform area) 32 levels of gray scale Controls W aveform intensity on front panel. Vectors on/off; infinite pe ...

  • Agilent Technologies 54600-Series - page 19

    19 Performance Characteristics (continued) Storage Save/Recall (non-volatile) 54621A/D, 54622A/D, 54624A: 3 setups and traces can be saved and recalled internally 54641A/D, 54642A/D: 4 setups and traces can be saved and recalled internally Floppy Disk 3.5” 1.44 MB double density Image formats : TIF , BMP Data formats: X and Y (time/voltage) value ...

  • Agilent Technologies 54600-Series - page 20

    20 Performance Characteristics (continued) Power Requirements Line V oltage Range 54621A/D, 54622A/D, 54624A: 100 - 240 V AC ±10%, CA T II, automatic selection 54641A/D, 54642A/D: 100-240 V AC, 50/60 Hz, CA T II, automatic selection; 100-132 VAC, 440 Hz, CA T II, automatic selection Line Frequency 54621A/D, 54622A/D, 54624A: 47 to 440 Hz 54641A/D, ...

  • Agilent Technologies 54600-Series - page 21

    21 Ordering Information Description 54621A 2-channel 60 MHz Oscilloscope 54621D 2+16 channel 60 MHz Mixed Signal Oscilloscope 54622A 2-channel 100 MHz Oscilloscope 54622D 2+16 channel 100 MHz Mixed Signal Oscilloscope 54624A 4-channel 100 MHz Oscilloscope 54641A 2-channel 350 MHz Oscilloscope 54641D 2+16 channel 350 MHz Mixed Signal Oscilloscope 54 ...

  • Agilent Technologies 54600-Series - page 22

    22 Available Options Description Option 003 Shielding Option for use in severe environments or with sensitive devices under test – shields both ways (in and out): RS-03 Magnetic interface shielding added to CRT , and RE-02 display shield added to CRT to reduce radiated interference Option 1CM Rackmount kit (same as 1186A) . W arranty and Calibrat ...

  • Agilent Technologies 54600-Series - page 23

    23 Ordering Information (continued) Fine Pitch Probing Description 10072A Fine-pitch probe kit 10075A 0.5 mm, IC clip kit E2613B 0.5mm, Wedge probe adapter , 3-signal, qty 2 E2614A 0.5 mm, Wedge probe adapter , 8-signal, qty 1 E2643A 0.5 mm, Wedge probe adapter 16-signal, qty 1 E2615B 0.65mm, Wedge probe adapter , 3-signal, qty 2 E2616A 0.65 mm, We ...

  • Agilent Technologies 54600-Series - page 24

    Call the measurement experts at Agilent T echnologies Whether your work is mostly digital, mostly analog, or somewhere in the middle, our measurement specialists can help you select the best debugging solution. Call today to talk to a knowledgeable engineer about your particular application. See for yourself with a no-obligation, 2-week demo If you ...

Manufacturer Agilent Technologies Category Respiratory Product

Documents that we receive from a manufacturer of a Agilent Technologies 54600-Series can be divided into several groups. They are, among others:
- Agilent Technologies technical drawings
- 54600-Series manuals
- Agilent Technologies product data sheets
- information booklets
- or energy labels Agilent Technologies 54600-Series
All of them are important, but the most important information from the point of view of use of the device are in the user manual Agilent Technologies 54600-Series.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Agilent Technologies 54600-Series, service manual, brief instructions and user manuals Agilent Technologies 54600-Series. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Agilent Technologies 54600-Series.

A complete manual for the device Agilent Technologies 54600-Series, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Agilent Technologies 54600-Series by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Agilent Technologies 54600-Series.

A complete Agilent Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Agilent Technologies 54600-Series - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Agilent Technologies 54600-Series, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Agilent Technologies 54600-Series, that we can find in the current document
3. Tips how to use the basic functions of the device Agilent Technologies 54600-Series - which should help us in our first steps of using Agilent Technologies 54600-Series
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Agilent Technologies 54600-Series
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Agilent Technologies 54600-Series in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Agilent Technologies 54600-Series?

Use the form below

If you did not solve your problem by using a manual Agilent Technologies 54600-Series, ask a question using the form below. If a user had a similar problem with Agilent Technologies 54600-Series it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)