    Fluke 430 Series Three-Phase Power Quality Analyzers Pinpoint power problems faster , safer and in greater detail T echnical Data The Fluke 434 and 433 three-phase power quality analyzers help you locate, predict, prevent and trou- bleshoot problems in power distribution systems. These easy-to-use handhelds are a “must have” for any person who ...

  • Fluke 430 Series - page 2

    Measures every thing Measure true-rms & peak voltage and current, frequency, dips and swells, transients, interrup- tions, power and power consumption, peak demand harmonics, inter-harmonics, flicker and unbalance. Automatic transient displa y Every time an event or distortion on voltage is detected, the instrument triggers and automati - cally ...

  • Fluke 430 Series - page 3

    Fluke 430 Series Three-Phase Power Quality Analyzers Fluke Corporation 3 System-Monitor: Multi- parameter power quality health check on one display A single push of the MO N ITOR button delivers a single dashboard display of rms voltage, har- monics, flicker, interruptions, rapid voltage changes, swells, unbalance and frequenc y . The dashboard is ...

  • Fluke 430 Series - page 4

    Specifications Input characteristics V oltage inputs Number of inputs 4 (3 phases + neutral) Maximum input voltage 1 000 Vrms Maximum peak voltage 6 kV Input impedance 4 M Ω / 5 pF Bandwidth 9 kHz, up to 1 00 kHz for transient display Scaling 1:1 , 1 0:1 , 1 00:1 , 1 000:1 and variable Current inputs Number of inputs 4 (3 phases + neutral) Type C ...

  • Fluke 430 Series - page 5

    Specifications continued Accuracy, resolution and range V olt/ Amps/ Hertz Measurement range Resolution Accuracy V rms (AC+DC) 1 to 1 000 Vrms 0. 1 Vrms ± 0.5 % of nominal voltage Vpk 1 to 1 400 Vpk 1 V 5 % of nominal voltage CFV 1 .0 to > 2.8 0. 1 ± 5 % Arms (AC+DC) 0 to 20,000 Arms 1 0,00 1 to 1 0 Arms 1 ± 1 % of reading ± 5 c ounts 3 with ...

  • Fluke 430 Series - page 6

    Specifications continued Trend recording Method AutoTrend automatically records min, max and average values over time for all readings being displayed for the 3 phases and neutral simultaneously V olts/amps/hertz, harmonics, pow er and energy, flicker and unbalance mode Sampling 5 readings/sec continuous sampling per channel Memory 1 800 min, max a ...

  • Fluke 430 Series - page 7

    Specifications continued General Case Design Rugged, shock proof with integrated protective holster Drip and dust proof I P5 1 according to I E C60529 when used in tilt stand position Shock and Vibration Shock 30 g, Vibration: 3 g Sinusoid, Random 0.03 g 2 / Hz according to M I L-P RF-28800F Class 2 Display Type Bright Full- Color LCD with C CFL ba ...

  • Fluke 430 Series - page 8

    Fluke Corporation PO Box 9 090, Everett, WA USA 9820 6 Fluke Europe B .V . PO Box 1 1 86, 56 02 BD Eindhoven, The Netherlands F or more information call: In the U.S .A. (800) 443-5853 or F ax (425) 446-5 1 1 6 In Europe/ M-East/Africa (3 1 40) 2 67 5 200 or F ax (3 1 40) 2 67 5 222 In Canada (8 00) 36- FLU KE or F ax (9 05) 89 0-6866 From other cou ...

Manufacturer Fluke Category Computer Monitor

Documents that we receive from a manufacturer of a Fluke 430 Series can be divided into several groups. They are, among others:
- Fluke technical drawings
- 430 Series manuals
- Fluke product data sheets
- information booklets
- or energy labels Fluke 430 Series
All of them are important, but the most important information from the point of view of use of the device are in the user manual Fluke 430 Series.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Fluke 430 Series, service manual, brief instructions and user manuals Fluke 430 Series. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Fluke 430 Series.

Similar manuals

A complete manual for the device Fluke 430 Series, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Fluke 430 Series by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Fluke 430 Series.

A complete Fluke manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Fluke 430 Series - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Fluke 430 Series, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Fluke 430 Series, that we can find in the current document
3. Tips how to use the basic functions of the device Fluke 430 Series - which should help us in our first steps of using Fluke 430 Series
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Fluke 430 Series
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Fluke 430 Series in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Fluke 430 Series?

Use the form below

If you did not solve your problem by using a manual Fluke 430 Series, ask a question using the form below. If a user had a similar problem with Fluke 430 Series it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)