  • Vermont Casting 2468 - page 1

    INST ALLER / CONSUMER SAFETY INFORMA TION 30002008 3/06 Rev . 6 PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING APPLIANCE. W ARNING! IF THE INFORMA TION IN THIS MANUAL IS NOT FOLLOWED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPER- TY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. FOR YOUR SAFETY Installation and service must be per- fo ...

  • Vermont Casting 2468 - page 2

    2 Dutchwes t N atur al V ent Gas H ea ter 30002008 PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a poss ...

  • Vermont Casting 2468 - page 3

    3 Dutchwes t N atur al V ent Gas H eater 30002008 The Dutchwest Natural V ent Room Heater , Model Nos. 2467 and 2468, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.33b-2001 for V ented Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use at High Al - titudes. The installation of the Dutchwest Natural V ent Roo ...

  • Vermont Casting 2468 - page 4

    4 Dutchwes t N atur al V ent Gas H eater 30002008 C L V alve Inlet C L V alve Inlet 2008 Dutchwest NV dimensions 6/23/03 17" (419 mm) 23" (584 mm) 28  " (721 mm) 4  " (1 1 1 mm) 6  " (172 mm) 12  " (318 mm) 24  " (622 mm) See Page 5 for Flue Collar Centerline Dimensions ...

  • Vermont Casting 2468 - page 5

    5 Dutchwes t N atur al V ent Gas H eater 30002008 Clearance Requirements Minimum Clearances to Combustible Materials Measure side clearances as shown in Figures 2 through 5 from the outer edge of the cast iron stove top. Measure rear clearances from the outermost surface of the sheet metal rear skirt. The Dutchwest heater is approved for installati ...

  • Vermont Casting 2468 - page 6

    6 Dutchwes t N atur al V ent Gas H eater 30002008 V enting Requirements and Options The Dutchwest must be properly connected to a listed 4” (102 mm) T ype B venting system or to an approved Class A masonry or factory-built chimney system. In Canada, a complete relining of Class A chimney sys- tems is required. The Dutchwest Natural V ent stove wi ...

  • Vermont Casting 2468 - page 7

    7 Dutchwes t N atur al V ent Gas H eater 30002008 Passing Through a Combustible W all or Ceiling An approved pass-through device is always required when a vent passes through a combustible wall or ceil- ing. Check with the maker of the vent system for the correct listed devices that are available. A listed pass- through device is required whether o ...

  • Vermont Casting 2468 - page 8

    8 Dutchwes t N atur al V ent Gas H eater 30002008 ST194 attach fan to shroud 1 1/99 Outer Shroud Slot Inner Shroud Slot ST194 Fig. 1 1 Position the fan to engage the inner shroud with the fan bracket slots and secure with sheet metal screws. ST720 attach snapstat 8/02 Left Air Duct Fan Inner Shroud ST720 Fig. 10 Attach snapstat wire assembly to ...

  • Vermont Casting 2468 - page 9

    9 Dutchwes t N atur al V ent Gas H eater 30002008 ST671 attach snapstat Snapstat Left Air Duct ST671 Fig. 12 Install the snapstat and connect the extension wire terminals. View is with top removed, however , access is available through the rear when installing fan before gas line connection. 9. After sliding the firebox in place, the rheostat cont ...

  • Vermont Casting 2468 - page 10

    10 Dutchwes t N atur al V ent Gas H eater 30002008 Connect the Gas Supply Line Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Dutchwest may be converted from one gas to another using the appropri- ate Fuel Conversion Kit listed on Page 23. Thi ...

  • Vermont Casting 2468 - page 11

    1 1 Dutchwes t N atur al V ent Gas H eater 30002008 Burner Information The appliance must only use the gas specified on the rating plate, unless converted using a CFM Corporation Fuel Conversion Kit. Refer to Page 23 for the correct Fuel Conversion Kit for your model. Conversion instructions are provided with each kit and beginning on Page 16 in t ...

  • Vermont Casting 2468 - page 12

    12 Dutchwes t N atur al V ent Gas H eater 30002008 Install the Stove Front Insert the handle stub into the hole in the front casting. Fasten in place with the 3/8” locking nut provided. (Fig. 23) The front attaches to the stove by four steel tabs that engage with corresponding cast ribs onto the sides and bottom of the stove body . Position the f ...

  • Vermont Casting 2468 - page 13

    13 Dutchwes t N atur al V ent Gas H eater 30002008 Operation Y our First Fire Read these instructions carefully and familiarize your- self with the burner controls. Locate the pilot assembly , Figure 25. Follow the lighting instructions on Page 14 exactly . During the first fire, it is not unusual to smell some odor associated with new logs, pain ...

  • Vermont Casting 2468 - page 14

    14 Dutchwes t N atur al V ent Gas H eater 30002008 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. T urn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONL Y , go on to Step 4. ...

  • Vermont Casting 2468 - page 15

    15 Dutchwes t N atur al V ent Gas H eater 30002008 A. Defective or misaligned Using a match, light [ilot. If pilot lights, turn off pilot and electrode at the pilot push the ignitor button again. If pilot will not light, check gap at electrode and pilot - it should be 1/8” to have a strong spark. B. Defective ignitor (push Push piezo ignitor butt ...

  • Vermont Casting 2468 - page 16

    16 Dutchwes t N atur al V ent Gas H eater 30002008 Conversion Precautions Conversion must be completed only by qualified per- sonnel. Before proceeding, turn control knob on valve to “OFF” and turn gas supply OFF . T urn OFF any electricity that may be going to the appliance. CAU- TION: Allow stove to cool completely before beginning conversio ...

  • Vermont Casting 2468 - page 17

    17 Dutchwes t N atur al V ent Gas H eater 30002008 CO105a gas conv ersion Pilot  1/28/00 djt  Pilot Hood Pilot Bracket CO105a Fig. 31 Remove pilot hood. CO106a D V360/580 Gas Con v ersion Pilot2 1/28/00 djt Index T ab Snap Ring Allen Wrench CO106a Fig. 32 Remove pilot orifice. • Remove pilot orifice with allen wrench. (F ...

  • Vermont Casting 2468 - page 18

    18 Dutchwes t N atur al V ent Gas H eater 30002008 Conversion to LP Input (BTU/h) Air Shutter Kit # Front Part # Rear Part # Minimum Maximum Setting 000-5022 #69 / .029” 30000513 #54 / .055” 20000130 21,500 28,000 3/8” Open Conversion to Natural Gas Input (BTU/h) Air Shutter Kit # Front Part # Rear Part # Minimum Maximum Setting 000-5021 #54 ...

  • Vermont Casting 2468 - page 19

    19 Dutchwes t N atur al V ent Gas H eater 30002008 Maintenance Y our Dutchwest Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly . Annual System Inspection Have the entire heater and venting system inspected annually by a qualified gas technician. ...

  • Vermont Casting 2468 - page 20

    20 Dutchwes t N atur al V ent Gas H eater 30002008 Gasket Replacement The Dutchwest Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer . Shut off the gas supply and allow the stove to cool. ...

  • Vermont Casting 2468 - page 21

    21 Dutchwes t N atur al V ent Gas H eater 30002008 NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP- PLIED WITH THE APPLIANCE, MUST BE RE- PLACED, IT MUST BE REPLACED WITH TYPE SF-2, 200°C WIRE OR ITS EQUIV ALENT . ST665 Fig. 41 Safety Limit Switch wiring.  Ther m ocoupl e Safety Limit Switch Valve ST665 Safety Limit Switch wiring 5/29/01 djt F AN ...

  • Vermont Casting 2468 - page 22

    22 Dutchwes t N atur al V ent Gas H eater 30002008 Dutchwest Natural V ent Gas Heater Models 2467, 2468 Ref. Description Part Number 1. SDV30 Log Set Assembly 20003458 1a. Rear Log 20003459 1b. Right Log 20003460 1c. Left Log 20003461 2. Small Lava Rock Package 57897 3. T op, NV DW Gas 30002005 4. Grille, NV DW Gas 30002044 5. Front, DW Gas 3000192 ...

  • Vermont Casting 2468 - page 23

    23 Dutchwes t N atur al V ent Gas H eater 30002008 Dutchwest Natural V ent Gas Heater (continued) Models 2467, 2468 Ref. Description Part Number 8. End, Rt - DW Gas 30001927 9. End, Lt - DW Gas 30001926 10. Gasket, Glass Med. Knit - RDV40 1203702 1 1. Glass, DV25 1601691 12. Glass Frame Assembly SDV30 30000127 13. Manifold T ube Assembly - Double B ...

  • Vermont Casting 2468 - page 24

    24 Dutchwes t N atur al V ent Gas H eater 30002008 Decorative Rings 4” brass or black rings are available to add a decorative touch to the exposed stove pipe. Model Description 4FSDRB/4 4” Black Rings (4) 4FSDRP/4 4” Polished Brass Rings (4) Outside Air Adapter An outside air adapter , #5076, may be added to the stove to bring fresh air for c ...

  • Vermont Casting 2468 - page 25

    25 Dutchwes t N atur al V ent Gas H eater 30002008 ...

  • Vermont Casting 2468 - page 26

    26 Dutchwes t N atur al V ent Gas H eater 30002008 ...

  • Vermont Casting 2468 - page 27

    27 Dutchwes t N atur al V ent Gas H eater 30002008 BASIC W ARRANTY CFM Corporation Company (hereinafter referred to collectively as the Company) warrants that your new Dutchwest Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations. ...

  • Vermont Casting 2468 - page 28

    Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 2467 51.4 2468 51.4 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation ...

Manufacturer Vermont Casting Category Fan

Documents that we receive from a manufacturer of a Vermont Casting 2468 can be divided into several groups. They are, among others:
- Vermont Casting technical drawings
- 2468 manuals
- Vermont Casting product data sheets
- information booklets
- or energy labels Vermont Casting 2468
All of them are important, but the most important information from the point of view of use of the device are in the user manual Vermont Casting 2468.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Vermont Casting 2468, service manual, brief instructions and user manuals Vermont Casting 2468. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Vermont Casting 2468.

A complete manual for the device Vermont Casting 2468, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Vermont Casting 2468 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Vermont Casting 2468.

A complete Vermont Casting manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Vermont Casting 2468 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Vermont Casting 2468, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Vermont Casting 2468, that we can find in the current document
3. Tips how to use the basic functions of the device Vermont Casting 2468 - which should help us in our first steps of using Vermont Casting 2468
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Vermont Casting 2468
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Vermont Casting 2468 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Vermont Casting 2468?

Use the form below

If you did not solve your problem by using a manual Vermont Casting 2468, ask a question using the form below. If a user had a similar problem with Vermont Casting 2468 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)