Manual Rinnai RHFE-750ETRA

40 pages 2.4 mb
Download

Go to site of 40

Summary
  • Rinnai RHFE-750ETRA - page 1

    — Do not store or use gasoline or ot her flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical swit ch; do not use any phone in your building. • Immediately call y our gas supplie r from a neighbor’s phone. Follow the ...

  • Rinnai RHFE-750ETRA - page 2

    2 Rinnai Corporation RHFE-750ETRA Consumer Safety Information Safety Definitions ........................................ 2 Safety Behaviors and Practices .................. 3 Safety Features .......................................... 3 Specifications ................................................. 4 Features ..................................... ...

  • Rinnai RHFE-750ETRA - page 3

    Rinnai Corporation RHFE-750ET RA 3 Safety Behavior and Practices Safety Features • Overheat: The appli ance will automatically shut down when the appliance ex cee ds a predetermined temperature. • Flame Failure: The appliance will automatically shut down if the burner flame is extinguished. • Power Failure: The appliance will cut off the gas ...

  • Rinnai RHFE-750ETRA - page 4

    4 Rinnai Corporation RHFE-750ETRA Application Vented gas fireplace heater; Inbuilt only; for residentia l installation, commer- cial setting, or manufactured home; not des igned for installation in a solid-fuel burning fireplace General Description Inbuilt convector, glass and steel fronted, ceramic lo g space heater with forced convection and po w ...

  • Rinnai RHFE-750ETRA - page 5

    Rinnai Corporation RHFE-750ET RA 5 Features • Direct Vent: Intake air is taken from the outside and the combustion products are exhausted to the outside. Therefore the furnace has no effect on the quality of the indoor air. • Push Button Ignition: Only one push of the STANDBY/ON switch is all that is required to operate the heater. • Lock: Th ...

  • Rinnai RHFE-750ETRA - page 6

    6 Rinnai Corporation RHFE-750ETRA Operating Instructions Front Panel Description Part Number Flat Metal - Bla ck Front R2 700 Flat Metal - Stainless Steel Front R2701 Radius (curved) Gla ss - Silver Front R2702 Radius (curved) Gla ss - Black Front R2703 Front Panel Models Front P anel (featu res are th e same f o r fl at an d cu rved mod els) TIM E ...

  • Rinnai RHFE-750ETRA - page 7

    Rinnai Corporation RHFE-750ET RA 7 • Use two 1.5V AAA batteries. • To replace batteries unscrew the battery compartment cover located on the back of the remote control counter clockwise. Ensure that the correct polarity is observed. The polarity is engraved into the battery compartment. Replace the cover by turning clockwise until a soft click ...

  • Rinnai RHFE-750ETRA - page 8

    8 Rinnai Corporation RHFE-750ETRA Sequence of Operations The combustion fan will ru n for several seconds before ignition to purge the combustio n chamber of any gas. If the front burner fails to ignite the appliance will turn off and fault code 11 will be displayed. If the rear burner fails to ignite the appliance will turn off and make another at ...

  • Rinnai RHFE-750ETRA - page 9

    Rinnai Corporation RHFE-750ET RA 9 Adjusting the Temperature Pressing the UP and DOWN buttons will change the temperature setting by 2 degree (F) increments. The display will show “Temperature” and the new temperature as confirmation. The temperature can be set to: • L (Low) - burner is on minimum combustion • 60° F - 80° F in two degree ...

  • Rinnai RHFE-750ETRA - page 10

    10 Rinnai Corporation RHFE-750ETRA Timers Programming the clock and timers The clock must be set before the timers will operate. The temperature setting during timer ope ration is the temperature last used when the appliance was on. During the steps belo w, if no button is pressed for 90 seconds then the screen will return to the current time displ ...

  • Rinnai RHFE-750ETRA - page 11

    Rinnai Corporation RHFE-750ET RA 11 Care and Maintenance Filters This appliance has two filters which are behind the louvers on either side of t he heater. The louvers are hinged to allow access to the filters. Dirty filters reduce the air flow and the appliance’ s Maintenance Repairs should be perform ed by a qualified service technician. The ap ...

  • Rinnai RHFE-750ETRA - page 12

    12 Rinnai Corporation RHFE-750ETRA W ARNING Do not clean glass when hot. Do not clean glass with abrasive clean ers. Care and Maintenance Over time combustion products may leave a film on the combustion chamber g lass. Continued use of the appliance may permanentl y stain the glass. If filming occurs, this glass panel needs to be rem oved, cleaned, ...

  • Rinnai RHFE-750ETRA - page 13

    Rinnai Corporation RHFE-750ET RA 13 T roubleshooting No display on remote Replace the remote control batteries. No ignition or no panel indications Ensure the appliance has power. Press the control panel ON/OFF button. Burners fail to ignite Air may need to be purged from the gas line. Several ignition attempts may purge the gas line. Turn on the g ...

  • Rinnai RHFE-750ETRA - page 14

    14 Rinnai Corporation RHFE-750ETRA Fault Codes If there is a malfunction the appliance may shut down as a safety precaution and display a fault code to assist in diagnosing the problem. The fault code will flash in the Fault Code Displa y window and the O peration Indicator will flash green. Code Fault Remedy 11 Ignition failure Confirm that the ga ...

  • Rinnai RHFE-750ETRA - page 15

    Rinnai Corporation RHFE-750ET RA 15 Installation Instructions General Instructions A qualified service technici an should install the appliance and inspect it before u se. The installation must conform with lo cal codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 , or the Natural Gas and Propane Installat ...

  • Rinnai RHFE-750ETRA - page 16

    16 Rinnai Corporation RHFE-750ETRA Flue T erminal Clearances INS I DE CO RN ER D E TA I L FIXED CLOSED OPERABLE FIXED CLOSED OPERABLE B B B A J B M C F B B E D L G A H K I X V AIR SUPPLY INLET VENT TERMINAL AREA WHERE TERMINAL IS NOT PERMITTTED The clearances to combus tibles as stated on the rating plate and as shown in the figure s must be follow ...

  • Rinnai RHFE-750ETRA - page 17

    Rinnai Corporation RHFE-750ET RA 17 Ref Description Canadian Installations US Installations A Clearance above grade, verand a, porch, deck, or balcony. (Take into account the anticipated snow line.) 12 inches ( 30 cm) 12 inches ( 30 cm) B Clearance to window or door that may be opened 12 inches (30 cm) 9 inches (23 cm) C Clearance to permanently cl ...

  • Rinnai RHFE-750ETRA - page 18

    18 Rinnai Corporation RHFE-750ETRA Do not vent the exhaust into ‘natural draft’ flue pipes or a chimney flue. The enclosure must be within these limits: NOTE: These are minimum clearance s. The front panel extends below the surfa ce on which the appliance rests. Ensure that clearance is maintained in order to install the front panel. Width (w) ...

  • Rinnai RHFE-750ETRA - page 19

    Rinnai Corporation RHFE-750ET RA 19 Cor r ec t Flo or Leve l Ins t allat ion Parti cle B oard, MD F , Pl ywood et c. Wa l l Li n i n g Parti cle B oard, MD F , P lyw ood etc . W all Li ning Particle Boar d, MD F , Plywood etc. Wa l l Li n i n g Floor ( T imber , Concre te, Tile, etc.) W all Lining Hearth Parti cle B oard, MD F , Pl ywood etc. W all ...

  • Rinnai RHFE-750ETRA - page 20

    20 Rinnai Corporation RHFE-750ETRA F l u e M a n i f o l d I n s t a l l a t i o n 1. Disassemble the Flue Manifold The flue consists of 3 parts: • sleeve • inside connection • terminal Disassemble the flue manifold by first pulling out the inside connection. To rem ove the outer terminal pull and release the two internal ties and then pull o ...

  • Rinnai RHFE-750ETRA - page 21

    Rinnai Corporation RHFE-750ET RA 21 2. Assemble and Adjust the Sleeve Lengt h Measure wall thickness through previously drilled 3 1/2 inch (90 mm) hole. The end of the sleeve should prot rude 3/16 - 3/8 inch (5-10 mm) from the outside wall. In the FOT-203 (Vent Kit A) there are 4 parts provided with which to assemble the sleeve. Use the table to de ...

  • Rinnai RHFE-750ETRA - page 22

    22 Rinnai Corporation RHFE-750ETRA V e n t i n g 5. Lock the ties Pulling hard on the left and right hand ties, clip the ties over the notches inside the sleev e. You should be able to pull the ties 2 or 3 notches p ast the starting point. Cut the ties, leaving about 3/4 inch (20 mm) past the notch. Bend the ties back into the sleeve and parallel t ...

  • Rinnai RHFE-750ETRA - page 23

    Rinnai Corporation RHFE-750ET RA 23 CONDENSATE COLLECTOR, 3CGDS HORIZONTAL TERMINATION, 3CGRHT Maximum Length = 33 feet (10 m) and 3 elbo w s Maximum Length draining back to appliance without a Condensate Collector = 8.2 feet (2.5 m) VERTICAL TERMINATION, 3CGRVT Sloped toward appliance to prevent condensate collectin g in the elbow. Certified and L ...

  • Rinnai RHFE-750ETRA - page 24

    24 Rinnai Corporation RHFE-750ETRA V e n t i n g Vent Length Switch If using extended venting, move the dip switch in the control panel to L-F. Vent Length Switch Additional Venting Clearances Wall Horizontal Vent Termination The distance between the wall and the air inlet cover should be 1.0 - 2.36 inches (25 - 60 mm) The top of the vertical termi ...

  • Rinnai RHFE-750ETRA - page 25

    Rinnai Corporation RHFE-750ET RA 25 6. Unscrew the flue acce ss panel held by two screws located inside the top left hand corne r of the appliance. Slide this panel to the right behind the convection fan. Connections 1. Carefully remove the packaged ceramic logs and place in a safe location. 2. To ensure the correct positioning, terminate the gas s ...

  • Rinnai RHFE-750ETRA - page 26

    26 Rinnai Corporation RHFE-750ETRA Connections 9. Remove clamp L and slide the vertical pipe M down into the lower elbow N to remove parts J and K. Separate J and K. 10. Attach pipe J to the flue manifold (or the adapter or the 2 inch elbow for extended venting) with clamp and screw. 11. Push the air intake line ont o the flue manifold or adapter a ...

  • Rinnai RHFE-750ETRA - page 27

    Rinnai Corporation RHFE-750ET RA 27 Final Assembly 1. Remove the t wo retaining screws that secu re the combustion chamber glass panel. 2. Rotate an d lift the combustion chamber glass clear of the combustion chamber and place in a safe location. 3. Seat the rear log into the combustion chamber onto its location pins. 4. Seat the left hand middle l ...

  • Rinnai RHFE-750ETRA - page 28

    28 Rinnai Corporation RHFE-750ETRA Place the condensate tray on top of the lower panel on the left side under the condensate tube. Place it flat so that it matches up with the shape of the lower panel. One edge of the tray has a sho rt lip. Position the tray so that this lip is towards the front of the appliance. Condensate Tray Front of appliance ...

  • Rinnai RHFE-750ETRA - page 29

    Rinnai Corporation RHFE-750ET RA 29 Air Guide Vanes To move the air flow more to the right or to the left, bend the air guide vanes using o nly light hand pressure. Do not bend repeatedly (no more than 5 times) o r else the vane will break. Install the Front Panel 1. Install the front panel by hooking the top into the body and rotating the bottom t ...

  • Rinnai RHFE-750ETRA - page 30

    30 Rinnai Corporation RHFE-750ETRA Operating Instructions FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING If you do not follow these instructio ns exactly, a fire or explosion may result causing property damage, pe rsonal injury or loss of life. A. This appliance is equippe d with an ignition device that automatically lights the pilot. Do not try t ...

  • Rinnai RHFE-750ETRA - page 31

    Rinnai Corporation RHFE-750ET RA 31 Wiring and Schematic Diagrams If any of the original wire as supplied with the appliance must be replace d, it must be replaced with type 18 AWG wire or its equivalent. Label all wires prior to disconnection when servicing controls. Wiring errors can cau se improper and dange rous operation. CAUTION ...

  • Rinnai RHFE-750ETRA - page 32

    32 Rinnai Corporation RHFE-750ETRA Parts List For replacement parts call Rinn ai at 1-800-621-9419. ...

  • Rinnai RHFE-750ETRA - page 33

    Rinnai Corporation RHFE-750ET RA 33 Parts List ...

  • Rinnai RHFE-750ETRA - page 34

    34 Rinnai Corporation RHFE-750ETRA Parts List 121 130 131 120 105 104 119 132 108 106 125 107 114 110 113 112 109 111 98 115 74 117 123 102 118 49 99 126 80 98 100 103 124 122 101 99 133 101 120 115 116 118 123 123 128 127 97 117 129 134 ...

  • Rinnai RHFE-750ETRA - page 35

    Rinnai Corporation RHFE-750ET RA 35 Parts List 1 1 10201 PANEL BASE RHFE750ET R 2 2 10777 FOOT KIT RHFE 3 1 BRACKET COMB CHAMBER SUPPORT RH R750 NON SERVICEABLE PART 4 1 BRACKET COMB CHAMBER SUPPORT LH R750 NON SERVICEABLE PART 5 2 10458 BRACKET FRONT MOUNT RHFE 6 2 10751 WHEEL KIT RHFE750/IBOF 7 2 10778 GLASS RET AINER SPRING KIT RHFE750 8 1 10232 ...

  • Rinnai RHFE-750ETRA - page 36

    36 Rinnai Corporation RHFE-750ETRA Parts List 48 2 10359F BURNER ASSEMBLY BRAY 250 Ø3.0 x 2 NG LEFT AND RIGHT ** 48 1 10359B BURNER ASSEMBLY BRAY 250 Ø6.0 x 2 LPG LEFT ONLY ** 48 1 10359G BURNER ASSEMBLY BRAY 250 Ø6.5 x 2 LPG RIGHT ONLY ** 49 1 10764 PILOT ASSEMBLY RHFE750 50 1 10772 PILOT ELECTRODE KIT RHFE750 INCLUDES DOUBLE ELECTRODE, FLAME R ...

  • Rinnai RHFE-750ETRA - page 37

    Rinnai Corporation RHFE-750ET RA 37 Parts List ITEM QTY PART NO. DESCRIPTION COMMENTS 90 1 10271 PACKING FOR AIR INLET BOX 91 1 10278 PACKING COMB FAN RHFE750ETR 92 1 10796 AIR INLET ASSEMBLY RHFE750 US 93 1 10349 AIR INLET HOSE 94 1 4328 AIR INLET ELBOW B 50x50 95 1 10330 HOSE SS 10 530 3/8SAE RHFE750 96 1 10567 VALVE 3/8" SAEM-FLARE 1/2" ...

  • Rinnai RHFE-750ETRA - page 38

    38 Rinnai Corporation RHFE-750ETRA Consumer Support W arranty Information Limited W arranty RHFE-750ETRA Direct Vent Fireplace What is covered? This Warranty covers any defects in ma terials or workmanshi p, subject to the terms stated below. This Wa rranty extends to the original purchaser and subsequent transferees, but only while the product rem ...

  • Rinnai RHFE-750ETRA - page 39

    Rinnai Corporation RHFE-750ET RA 39 Limited W arranty - continued What will Rinnai do? Rinnai will repair any part or compo nent that is defective in materials or workmanship as set forth as follo ws. All repair parts must be genu ine Rinnai parts. All repairs or replacements must be performed by an individual or servicing company that has been aut ...

  • Rinnai RHFE-750ETRA - page 40

    15237 (Issue G) Manufactured by Rinnai New Zealand LTD 105 Pavilion Drive, Airport Oaks Mangerg, Manukau City New Zealand ...

Manufacturer Rinnai Category Indoor Fireplace

Documents that we receive from a manufacturer of a Rinnai RHFE-750ETRA can be divided into several groups. They are, among others:
- Rinnai technical drawings
- RHFE-750ETRA manuals
- Rinnai product data sheets
- information booklets
- or energy labels Rinnai RHFE-750ETRA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Rinnai RHFE-750ETRA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Rinnai RHFE-750ETRA, service manual, brief instructions and user manuals Rinnai RHFE-750ETRA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Rinnai RHFE-750ETRA.

A complete manual for the device Rinnai RHFE-750ETRA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Rinnai RHFE-750ETRA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Rinnai RHFE-750ETRA.

A complete Rinnai manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Rinnai RHFE-750ETRA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Rinnai RHFE-750ETRA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Rinnai RHFE-750ETRA, that we can find in the current document
3. Tips how to use the basic functions of the device Rinnai RHFE-750ETRA - which should help us in our first steps of using Rinnai RHFE-750ETRA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Rinnai RHFE-750ETRA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Rinnai RHFE-750ETRA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Rinnai RHFE-750ETRA?

Use the form below

If you did not solve your problem by using a manual Rinnai RHFE-750ETRA, ask a question using the form below. If a user had a similar problem with Rinnai RHFE-750ETRA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)