    Pr oduct Dat a MODEL 213R LEGACY t - - RNC SE RIES HE A T PUMP SIZE S 018 T O 060 1 - - 1/2 TO 5 NOMINAL TONS Sh own w ith opt ional dens e coil guar d FEA TURES / BENEFITS Effi ciency S 13 SEER/ 1 1 EER / Up to 8. 6 HSPF (Nomina l) S Mi cr otube T ec hnology t refrigeration sy stem S Indoor a ir qua lity accessories av ailable Sound S Sound leve l ...

  • Bryant LEGACY 213R - page 2

    2 MODEL NUMBER NOMENCLA T URE 1 2 34 5 6 7 8 9 1 0 1 11 2 1 4 N N N A A/N N N N N A/N A/N N A 21 3 R N A 0 3 6 0 0 0 0 Pro d- uct Fa mil y Tier SEER Major Series Voltag e V ar i ati ons Cooling Capaci ty Open Open Open S erie s 2=HP 1= Leg acy RNC 3=13 SEER R=R - - - 22 N= 208/230 - - - 1 P=208/230 --- 3 E=460/3 A=S t a n d a r d G=Den se Coil Gua ...

  • Bryant LEGACY 213R - page 3

    3 PHYS ICAL DA T A UNIT SIZE - - - SE RIES 018 - - - A 024 - - - A 030 - - - A 036 - - - A 042 - - - A 048 - - - A 060 - - - A Operat ing Weig ht (lb ) 159 160 208 211 233 269 295 Shippin g Weight (lb) 184 185 240 242 262 300 327 Compressor T ype Scroll REFRIGERAN T Fr e on ® ( R --- 2 2 ) Cont rol T X V ( R --- 2 2 H a r d S h u t o f f ) Charge ...

  • Bryant LEGACY 213R - page 4

    4 ACCESSO R Y THERMOST A TS THE RMOSTA T / SU BB ASE PKG. DESCRI PTI ON TST ATBBPRH01 - - - B* Thermi dist at t Control — Non - - - Programmable/Programm able Thermostat wi th Humi dity Cont rol ( F or use in Dual F uel, AC, HP , and 2S appli cat ions . Include s Out- door Air T empe rature Sensor .) TST ATBBPHH01 - - - B* HybridHeat t (Dual F ue ...

  • Bryant LEGACY 213R - page 5

    5 ACCESSO R Y USAGE GUIDELINE Accessor y RE QUIRED FOR L OW - - - AMBI - ENT APPLIC A TIONS (Below 55 ° F) RE QUIRED FOR L ONG LINE APPLICATIONS* (Over 80 F t.) REQUI RED FOR SEA COAS T APPLICATIONS (Within 2 miles) Crankc ase Heat er Ye s Ye s No Evapora t or Freeze T hermostat Ye s No No Accum ulator No No No Compressor Star t Assist Capacitor a ...

  • Bryant LEGACY 213R - page 6

    6 Accesso ry Des cripti on and Us age (Listed Al ph abetica lly) - - CO NTINUE D 1 1. Outdoor Air T empe rat ur e Sens or De si gne d for use wi th Br yant The rmos ta ts l is ted in t his publi cat ion. This de vice e nable s the ther mosta t to displ ay the outdoor te mpe ra ture . This devi ce als o is re quire d to e nable special th ermo stat ...

  • Bryant LEGACY 213R - page 7

    7 ELECTRICAL DA T A (VOL TAGE) UNIT S IZE --- S E R I E S V/PH OPER VOL TS* COMP R FA N MCA MIN WIRE SIZE { MIN WIRE SIZE { MAX LENG TH (FT) } MAX LENG TH (FT) } MAX FUSE* * or CKT BRK AMPS MAX MIN LRA RLA FL A 60 ° C 75 ° C 60 ° C 75 ° C (N) 018 - - - A 208/230/1 253 187 41 9.0 0.5 11.70 14 14 166 158 20 (N) 024 - - - A 54 11.3 0.8 14.80 14 14 ...

  • Bryant LEGACY 213R - page 8

    8 DIMENSIONS NOTE : Opti onal “G ” dens e coil gua rd shown. 213R ...

  • Bryant LEGACY 213R - page 9

    9 213RN(A, G) BALANCE POINT WORKSHEET 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 - - 1 00 1 0 2 03 04 05 0 6 07 08 0 OUTDOOR TEMPERA TURE, ºF BUILDI NG HEA T LOSS, UNIT I NTEGRA TED HEA TING CAP ACITY , MBTUH 0.0 2.9 5.9 8.8 11 . 7 14.6 17.6 20.5 23.4 kW 213RN( A,G)024A F A4CN F024 213RN( A,G)030A F A4CN F030 213RN( A,G)036A FC4DNF036 A0 ...

  • Bryant LEGACY 213R - page 10

    10 COMBINA TION RA TINGS Unit Size --- S e r i e s Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce Mo del Fac tor y Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity EC O P H Capacity HC O P 018 - - - A *FA4CN(F ,C)018 17,100 TDR&TXV 13.00 10.80 18,000 3.52 10,500 2.34 8.0 F A4CN(F ,C)024 17, ...

  • Bryant LEGACY 213R - page 11

    11 COMBINA TION RA TINGS - - CONTINUED Unit Size --- S e r i e s Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce Mo del Fac tor y Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity EC O P H Capacity HC O P 024 - - - A CNRV*2414A** 22,800 TXV 13.00 10.80 23,800 3.66 14,500 2.38 8.2 CNRV*2414A** 22, ...

  • Bryant LEGACY 213R - page 12

    12 COMBINA TION RA TINGS - - CONTINUED U n i t S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce Mo del Fac tor y Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity EC O P H Capacity HC O P 030 - - - A *FA4CN(F ,C)030 28,400 TDR&TXV 13.00 10.80 30,200 3.46 18,700 2.42 8.1 FC4D ...

  • Bryant LEGACY 213R - page 13

    13 COMBINA TION RA TINGS - - CONTINUED U n i t S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce Mo del Fac tor y Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity EC O P H Capacity HC O P 030 - - - A CNRH*3617A** 28,400 TDR&TXV 14.00 11.50 29,000 3.54 18,000 2.50 8.2 355AAV0 ...

  • Bryant LEGACY 213R - page 14

    14 COMBINA TION RA TINGS - - CONTINUED U n i t S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce Mo del Fac tor y Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity EC O P H Capacity HC O P 036 - - - A CNRV*4221A** 33,600 TDR&TXV 13.20 11.00 35,200 3.50 20,600 2.46 8.1 355AAV0 ...

  • Bryant LEGACY 213R - page 15

    15 COMBINA TION RA TINGS - - CONTINUED U n i t S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce Mo del Fac tor y Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity EC O P H Capacity HC O P 042 - - - A CAR**4224A** 40,500 TDR&TXV 13.20 11.00 41,000 3.44 25,400 2.48 7.7 355AAV0 ...

  • Bryant LEGACY 213R - page 16

    16 COMBINA TION RA TINGS - - CONTINUED U n i t S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce Mo del Fac tor y Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity EC O P H Capacity HC O P 042 - - - A CSRH*4212A* * 41,000 TDR&TXV 13.50 11.20 41,000 3.58 25,600 2.54 8.0 355AAV ...

  • Bryant LEGACY 213R - page 17

    17 COMBINA TION RA TINGS - - CONTINUED U n i t S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce Mo del Fac tor y Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity EC O P H Capacity HC O P 048 - - - A CNRH*6024A** 45,500 TDR&TXV 13.20 11.00 47,500 3.22 29,800 2.48 8.0 355AAV0 ...

  • Bryant LEGACY 213R - page 18

    18 DET AILED COOLING CAP ACITIES EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EW B Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh† T otal Sys- ...

  • Bryant LEGACY 213R - page 19

    19 DET AILED COOLING CAP ACITIES - - CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal S ...

  • Bryant LEGACY 213R - page 20

    20 DET AILED COOLING CAP ACITIES - - CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh? ...

  • Bryant LEGACY 213R - page 21

    21 DET AILED COOLING CAP ACITIES - - CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh† T otal Sys- tem KW* * Capacity MBtuh? ...

  • Bryant LEGACY 213R - page 22

    22 DET AILED COOLING CAP ACITIES - - CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal S ...

  • Bryant LEGACY 213R - page 23

    23 DET AILED COOLING CAP ACITIES - - CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal S ...

  • Bryant LEGACY 213R - page 24

    24 DET AILED COOLING CAP ACITIES - - CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal S ...

  • Bryant LEGACY 213R - page 25

    25 HEA T PUMP HEA TING PERFORMANCE INDOOR AIR OUTDOOR COIL EN TERING AIR TEMPERA TURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- ...

  • Bryant LEGACY 213R - page 26

    26 HEA T PUMP HEA TING PERFORMANCE - - CONTINUED INDOOR AIR OUTDOOR COIL EN TERING AIR TEMPERA TURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh ...

  • Bryant LEGACY 213R - page 27

    27 HEA T PUMP HEA TING PERFORMANCE - - CONTINUED INDOOR AIR OUTDOOR COIL EN TERING AIR TEMPERA TURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh ...

  • Bryant LEGACY 213R - page 28

    28 HEA T PUMP HEA TING PERFORMANCE - - CONTINUED INDOOR AIR OUTDOOR COIL EN TERING AIR TEMPERA TURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh ...

  • Bryant LEGACY 213R - page 29

    29 HEA T PUMP HEA TING PERFORMANCE - - CONTINUED INDOOR AIR OUTDOOR COIL EN TERING AIR TEMPERA TURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh ...

  • Bryant LEGACY 213R - page 30

    30 HEA T PUMP HEA TING PERFORMANCE - - CONTINUED INDOOR AIR OUTDOOR COIL EN TERING AIR TEMPERA TURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh ...

  • Bryant LEGACY 213R - page 31

    31 HEA T PUMP HEA TING PERFORMANCE - - CONTINUED INDOOR AIR OUTDOOR COIL EN TERING AIR TEMPERA TURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh ...

  • Bryant LEGACY 213R - page 32

    32 GUIDE SPECIFICA TIONS GENERAL System Description Outdoor- - mounted, air- - cooled, split - -system heat pump unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor , an air - - cooled coil, propeller- -type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Un ...

Manufacturer Bryant Category Heat Pump

Documents that we receive from a manufacturer of a Bryant LEGACY 213R can be divided into several groups. They are, among others:
- Bryant technical drawings
- LEGACY 213R manuals
- Bryant product data sheets
- information booklets
- or energy labels Bryant LEGACY 213R
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bryant LEGACY 213R.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bryant LEGACY 213R, service manual, brief instructions and user manuals Bryant LEGACY 213R. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bryant LEGACY 213R.

Similar manuals

A complete manual for the device Bryant LEGACY 213R, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bryant LEGACY 213R by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bryant LEGACY 213R.

A complete Bryant manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bryant LEGACY 213R - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bryant LEGACY 213R, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bryant LEGACY 213R, that we can find in the current document
3. Tips how to use the basic functions of the device Bryant LEGACY 213R - which should help us in our first steps of using Bryant LEGACY 213R
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bryant LEGACY 213R
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bryant LEGACY 213R in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bryant LEGACY 213R?

Use the form below

If you did not solve your problem by using a manual Bryant LEGACY 213R, ask a question using the form below. If a user had a similar problem with Bryant LEGACY 213R it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)