  • Emerson 1F82-261 - page 1

    Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage. Thermostat installation and all components of the sy ...

  • Emerson 1F82-261 - page 2

    2 INST ALLA TION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermo- stat and th ...

  • Emerson 1F82-261 - page 3

    3 L R E 24 VAC 120 VAC Hot SYSTEM MONITOR SWITCH Neutral THERMOSTAT SYSTEM G W2 Figure 2. Typical wiring diagram for single transformer systems TRANSFORMER (Class II Current Limited) Changeover Relay* C Y O/B Compressor Contactor * Changeover Relay is energized in COOL when O/B switch is in the “O” position Changeover Relay is energized in HEAT ...

  • Emerson 1F82-261 - page 4

    4 2 1 3 4 5 6 7 8 11 14 16 12 15 11 10 13 13 9 9 Figure 5. Thermostat display, buttons, and switches SU EMER HOLD PM SA MALF FLTR AM MO TU WE TH FR TIME PRGM RUN HOLD Fltr FAN EMER ON AUTO COOL OFF HEAT OPERA TION Do not allow the compressor to run unless the com- pressor oil heaters have been operational for 6 hours and the system has not been ope ...

  • Emerson 1F82-261 - page 5

    5 Press HOLD to change to the next menu item or press TIME to go backwards to the previous item in the menu. To exit the menu and return to the program operation, press RUN. If no keys are pressed within fifteen minutes, the thermostat will revert to normal operation. 1) Select Temporary Hold Time - The thermostat can hold any temperature you set i ...

  • Emerson 1F82-261 - page 6

    6 WEEKDAYS (5 Day) SATURDAY (1 Day) Start Time Temp Start Time Temp 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH SAMPLE Heating/Cooling Schedule Plan (Factory Program) Period 6:00 AM 8:00 AM 5:00 PM 10:00 PM 6:00 AM 8:00 AM 5:00 PM 10:00 PM 6:00 AM 8:00 AM 5:00 PM 10:00 PM 6:00 AM 8:00 AM 5:00 PM 10:00 PM 70 ° F 62 ° F 70 ° F 62 ° F 78 ° F 85 ° F 78 ° F ...

  • Emerson 1F82-261 - page 7

    7 Use the table to plan your program time periods and the temperatures you want during each period. Fill in the complete table to have a record of your programs. Entering Your Program Set Current Time and Day 1. Press TIME button once. The display will show the hour only. EXAMPLE: PM 2. Press and hold either or until you reach the correct hour and ...

  • Emerson 1F82-261 - page 8

    TROUBLESHOO TING Symptom P ossible Cause Corrective Action No Hea No Hea No Hea No Hea No Hea t/No Cool/No F t/No Cool/No F t/No Cool/No F t/No Cool/No F t/No Cool/No F an an an an an 1. Blo wn fuse or tripped circuit breaker . Replace fuse or reset breaker . (common problems) (common problems) (common problems) (common problems) (common problems) ...

Manufacturer Emerson Category Heat Pump

Documents that we receive from a manufacturer of a Emerson 1F82-261 can be divided into several groups. They are, among others:
- Emerson technical drawings
- 1F82-261 manuals
- Emerson product data sheets
- information booklets
- or energy labels Emerson 1F82-261
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson 1F82-261.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson 1F82-261, service manual, brief instructions and user manuals Emerson 1F82-261. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson 1F82-261.

Similar manuals

A complete manual for the device Emerson 1F82-261, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson 1F82-261 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson 1F82-261.

A complete Emerson manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson 1F82-261 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson 1F82-261, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson 1F82-261, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson 1F82-261 - which should help us in our first steps of using Emerson 1F82-261
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson 1F82-261
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emerson 1F82-261 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emerson 1F82-261?

Use the form below

If you did not solve your problem by using a manual Emerson 1F82-261, ask a question using the form below. If a user had a similar problem with Emerson 1F82-261 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)