    Multimeter Selection Guide Fluke 8508A & Agilent 3458/HFL TECHNICAL INFORMATION When comparing two products features and specification using sales information it is often difficult to determine which pr oduct will meet the needs of your specific application. This is mostly because each supplier will define specifications using alternate methods ...

  • Fluke 3458/HFL - page 2

    DC Volt age ±( ppm of se tt ing + ppm of r ange) , r el ati ve t o cal i brat i on sta nd ar ds use d . Cali brat i on I nt e rv al 365 day , ±1°C of l ast TC AL R ange 1281 H P3458/HF L 8508A 120. 00000m V - 4 + 3 - 199. 999999m V 6 + 0. 5 - 2. 7 + 0.5 1. 20000000V - 3 + 0. 3 - 1. 99999999V 3 + 0.2 - 2. 7 + 0. 2 12. 000000V - 3 + 0. 05 - 19. 99 ...

  • Fluke 3458/HFL - page 3

    DC C urrent ±(ppm of setting + ppm of range), relative to calib ration standards used. Calibration Interval 365 day , ±1°C of last TCAL Range 1281 HP3458/HFL 8508A 120.000nA - 30 + 400 - 1.200000µA - 20 + 40 - 12.000000µA - 20 + 10 - 120.00000µA - 20 + 8 - 199.99999µA 25 + 2 - 6.5 + 2.0 1.2000000mA - 20 + 5 - 1.9999999mA 25 + 2 - 6.5 + 2.0 1 ...

  • Fluke 3458/HFL - page 4

    Resistance ±(ppm of setting + ppm of range), relative to calibration standa rds used. Calibration Interv al 365 day, ±1°C of las t TC AL Range 1281 HP3458/HFL 8508A 1.99999999 Ohm - - 10 + 2.0 12.00000 Ohm - 10 + 5 - 19.9999999 Ohm 12 + 1.0 - 7.0 + 0.7 120.00000 Ohm - 8 + 5 - 199.999999 Ohm 8 + 0.3 7.0 + 0.25 1.2000000 kOhm - 7 .5 + 0.5 - 1.9999 ...

  • Fluke 3458/HFL - page 5

    A C Current ±(ppm of setting + ppm o f range), rela tive to cal ibrati on standards use d. Calibration Interval 365 day, ±1°C of last TCAL Range Frequency 1281 HP3458/HFL 8508A 120.0000µA 10Hz - 20Hz - 4000 + 200 - 20Hz - 45Hz - 1500 + 200 - 45Hz - 100Hz - 600 + 200 - 100Hz - 5kHz - 600 + 200 - 199.9999µA 1Hz - 10Hz - - 250 + 100 10Hz - 5kHz 2 ...

  • Fluke 3458/HFL - page 6

    A C Voltage ± (ppm of setting + ppm of range), relative to cali bration standards used. Cali bration Interval 365 day, ±1°C of last TCA L Range Frequ ency 1281 HP3458/HFL 8508A 12.00000 mV 1Hz - 40Hz - 300 + 300 - 40Hz - 1kHz - 200 + 110 - 1kHz - 20 kHz - 300 + 110 - 20kHz - 50k Hz - 1000 + 110 - 50kHz - 100 kHz - 5000 + 110 - 100kHz - 300kHz - ...

  • Fluke 3458/HFL - page 7

    A C Voltage ± (ppm of setting + ppm of range), relative to cali bration standards used. Calibration Int erval 365 day, ±1°C of last T CAL Range Frequency 1281 HP3458/HFL 8508A 19.99999V 1Hz - 10Hz - - 100 + 60 10Hz - 40Hz - - 100 + 10 40Hz - 100Hz 80 + 10 - 80 + 10 100Hz - 2kHz 60 + 10 - 60 + 10 2kHz - 10kHz 80 + 10 - 80 + 10 10kHz - 30kHz 200 + ...

  • Fluke 3458/HFL - page 8

    Fluke 8508A 3458/HFL 8508A vs 3458/HFL Functional & Versatility Parameters Comments Full Scale (dc & ac Voltage) 200mV, 2V, 20V, 200V, 1050Vrms 120mV, 1.2V, 12V, 120V, 1050Vdc (ac = 700Vrms) 8508A maintains >10Gohm input impedance to 20Vdc. This compares with 12V on 3458/HFL. The 8508A 1050Vrms measurement is often used to calibrate cali ...

  • Fluke 3458/HFL - page 9

    8508A vs 3458/HFL Functional & Versatility Parameters Comments High Resistance Measurement (compliance voltage) Test Voltage or Full Scale stimulus = 200V Test Voltage or Full Scale stimulus @ 1.2G Ω = 5V Reduces errors when performing high resistance measurement (feature available 8508A - 20M Ω to 20G Ω range only) Tru-Ohms or Offset Com ...

  • Fluke 3458/HFL - page 10

    ACV & DCV 4 wire input. Selectable 2 and 4-wire measurement. Unavailable 4-wire sense measurement support improved accuracy when calibrating calibrators with 4 wire sense output. Remote switched GUARD Terminal IEEE controlled Manual Switch IEEE control of GUARD terminal helps fully automate calibration without need for manual switching. Read ra ...

  • Fluke 3458/HFL - page 11

    8508A vs 3458/HFL Ease of Use Parameters Comments Rear input switched remotely using IEEE 488 commands Yes No The 3458/HFL must be switched manually using a front panel button. Instrument simultaneously displays Frequency as well as the AC voltage & current. Yes Selectable Requires further commands or key presses to determine frequency. Two cha ...

  • Fluke 3458/HFL - page 12

    8508A Options and Accessories: Model Description 8508A 8.5 digit Reference Multimeter 8508A/01 8.5 digit Reference Multimeter with Rear Input Ratio measurement Accessories 8508A-SPRT Standard Platinum Resistanc e Thermometer 8508A-PRT Platinum Resistance Thermometer 8508A-LE AD Comprehensive Measuremen t Lead Kit Y8508 Rack Mount Kit Y8508S Rack Mo ...

  • Fluke 3458/HFL - page 13

    Notes: ...

Manufacturer Fluke Category Wireless Office Headset

Documents that we receive from a manufacturer of a Fluke 3458/HFL can be divided into several groups. They are, among others:
- Fluke technical drawings
- 3458/HFL manuals
- Fluke product data sheets
- information booklets
- or energy labels Fluke 3458/HFL
All of them are important, but the most important information from the point of view of use of the device are in the user manual Fluke 3458/HFL.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Fluke 3458/HFL, service manual, brief instructions and user manuals Fluke 3458/HFL. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Fluke 3458/HFL.

Similar manuals

A complete manual for the device Fluke 3458/HFL, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Fluke 3458/HFL by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Fluke 3458/HFL.

A complete Fluke manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Fluke 3458/HFL - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Fluke 3458/HFL, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Fluke 3458/HFL, that we can find in the current document
3. Tips how to use the basic functions of the device Fluke 3458/HFL - which should help us in our first steps of using Fluke 3458/HFL
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Fluke 3458/HFL
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Fluke 3458/HFL in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Fluke 3458/HFL?

Use the form below

If you did not solve your problem by using a manual Fluke 3458/HFL, ask a question using the form below. If a user had a similar problem with Fluke 3458/HFL it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)