Manual Siemens 410

82 pages 0.73 mb
Download

Go to site of 82

Summary
  • Siemens 410 - page 1

    MICROMASTER 410 Operatin g I nstructions Issue A1 User Documentation Order number: 6SE6 400-5EA0 0-0BP0 ...

  • Siemens 410 - page 2

    MICROMA STER 410 Documentat ion Getting Star te d Guide Is for quick commiss ioning. Operating Instru ctions Gives inf orm ation about f eatures of the MM410, Installat ion, Comm iss ioning, Contr ol m odes, System Param eter str ucture, T roublesh ooting , Specif ications and availab le opt ions of the MM410. Paramet er List The Param eter Lis t c ...

  • Siemens 410 - page 3

    MICROMASTER 410 Operating Instructions User Docum entation Valid for Issue 10/0 1 Converter Ty pe MICROMAST ER 410 Issue A 1 Overv iew 1 Installation 2 Commissioning 3 Using the MICROMA STER 410 4 Syst em Parameters 5 Troubleshooting 6 MICROMA STER 410 Spec ifications 7 Available options 8 Electro-Ma gnetic Compatibility 9 A ppendices A B C Index ...

  • Siemens 410 - page 4

    MICROMASTER 410 Operating Instructions 4 6SE6400-5EA 00-0BP0 Further information can be obtained from Internet website: ht tp :/ /ww w.s i em ens . de/m ic r omas t er Approved Siemens Qualit y for S oft ware and Training is to DIN ISO 9001, Reg. No. 2160-01 The reproduction, t ransm ission or use of this doc ument, or its contents is not permitted ...

  • Siemens 410 - page 5

    Issue A1 Foreword MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 5 Forew ord User Documentation WARNING Before i nstalli ng and com mis sioning the inver ter, you must read a ll saf ety instruc tions an d warn ings c arefull y inclu ding al l the warn ing l abels att ached to t he equipm ent. Mak e sure that th e war ning labe ls are k ...

  • Siemens 410 - page 6

    Definitions and W arnings Issue A1 MICROMASTER 410 Operating Instructions 6 6SE6400-5EA 00-0BP0 Definitions and Warnings DA NGE R indicates an imm ientl y hazardo us situa tion wh ich, if not avoid ed, will r esult in deat h or serious injur y. WARNING indicates a potent iall y hazardo us situa tion which, if not avo ided, co uld resul t in death o ...

  • Siemens 410 - page 7

    Issue A1 Safety Ins tructions MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 7 Safety Instructions The f ollowing W arnings , Cautio ns and Not es are provided f or your safet y and as a means of preventi ng dam age to the product or com ponents in th e m achines connecte d. This s ection l ists W arnings, Ca utions an d Notes, which ap ...

  • Siemens 410 - page 8

    Safety Ins tructions Issue A1 MICROMASTER 410 Operating Instructions 8 6SE6400-5EA 00-0BP0 Transport & Storage WARNING ♦ Correct tr ansport, s torage, er ection an d m ounting, as well as car eful operatio n and m aintenanc e are es sentia l for pr oper and safe oper ation of the equipm ent. CA UTI ON ♦ Protect t he inver ter aga inst ph ys ...

  • Siemens 410 - page 9

    Issue A1 Safety Ins tructions MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 9 Opera tion WARNING ♦ MICROMAST ERS op erate at high voltag es. ♦ W hen operating electric al devic es, it is im possible to avoid appl ying hazardo us volta ges to c ertain p arts of the equipm ent. ♦ Emer gency Stop f acilities accordi ng to EN 6 0204 ...

  • Siemens 410 - page 10

    Safety Ins tructions Issue A1 MICROMASTER 410 Operating Instructions 10 6SE6400-5EA 00-0BP0 ...

  • Siemens 410 - page 11

    Issue A1 Table of C ontents MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 11 Table of Contents 1 Overv iew ................................................................................................................ 15 1.1 The MICROM ASTER 4 10 ....................................................................................... ...

  • Siemens 410 - page 12

    Table of C ontents Iss ue A1 MICROMASTER 410 Operating Instructions 12 6SE6400-5EA 00-0BP0 8 Options ................................................................................................................... 67 8.1 Variant Inde pendent O ptions .................................................................................. 67 8.2 Varian ...

  • Siemens 410 - page 13

    Issue A1 Table of C ontents MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 13 List of Ill ustrati ons Figure 2-1 Forming.............................................................................................................. ...................18 Figure 2-2 Power Losse s, 230 V ..................................................... ...

  • Siemens 410 - page 14

    Table of C ontents Iss ue A1 MICROMASTER 410 Operating Instructions 14 6SE6400-5EA 00-0BP0 ...

  • Siemens 410 - page 15

    Issue A1 1 Overv iew MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 15 1 Over view 1.1 The MICROM A STER 410 The MICROM ASTER 4 10s are a range of f requency inv erters f or control ling the speed of three phas e AC m otors. T he various models availa ble rang e from 120 W to 750 W single-phas e input. The inv erters are m icr oprocess ...

  • Siemens 410 - page 16

    1 Overv iew Issue A1 MICROMASTER 410 Operating Instructions 16 6SE6400-5EA 00-0BP0 Performance Characteristics Ø F lux Current Control (F CC) for im prove d d ynamic res ponse and m otor c ontrol Ø F ast Current Lim itation (FCL) f or trip-f ree oper ation Ø Built -in D C in jectio n bra ke Ø Com pound br aking to im prove brak ing per form anc ...

  • Siemens 410 - page 17

    Issue A1 2 Installati on MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 17 2 Inst allation WARNING ♦ ♦ ♦ ♦ W ork on the devic e/s ystem b y unqualif ied pers onnel or failur e to com ply wit h warnings c an resu lt in se vere per sonal injur y or serious dam age to m aterial. Only suit abl y qualifie d pers onnel tra ined in the ...

  • Siemens 410 - page 18

    2 Installati on Issue A1 MICROMASTER 410 Operating Instructions 18 6SE6400-5EA 00-0BP0 2.1 General Insta lla tion afte r a P erio d o f S torag e Follo wing a pro longed per iod of storage, you m ust ref orm the c apacitors in the inverter . It is impo rtant t hat the time o f storag e is calcu lated from the time of manufacture and not the time of ...

  • Siemens 410 - page 19

    Issue A1 2 Installati on MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 19 2.2 Power Losses Figure 2- 2 sho ws the power l oss f or the MICROMAST ER 410 Inverter . The graph c an be us ed to rea d the loss at f ull load of a part icular v ariant. 2.3 A mbient oper ating condi ti ons Temperature Frame Size AA AB Min. [ ° ° ° ° C] -10 ...

  • Siemens 410 - page 20

    2 Installati on Issue A1 MICROMASTER 410 Operating Instructions 20 6SE6400-5EA 00-0BP0 Shock Do not drop the inv erter or exp ose to sudden shoc k. Do no t instal l the in verter in an area where it is lik el y to be exposed to cons t ant vi brat ion. Mechanic al strengt h to EN 60721-3- 3 Ø Deflectio n: 0.075 mm (10 ... 58 H z) Ø Accel erati on: ...

  • Siemens 410 - page 21

    Issue A1 2 Installati on MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 21 2.4 Harmonic Current s Harm onic curr ents with 1% m ains im pedance. Table 2-1 Single Pha se 115 V Co nnection MLFB Filter Type Power CT (kW) Fundamen- tal Amps 3 rd Amp s 5 th Amp s 7 th Amp s 9 th Amp s 11 th Amp s 13 th Amp s 6SE6410-2UA11-2A A0 UNFILTERED 0, ...

  • Siemens 410 - page 22

    2 Installati on Issue A1 MICROMASTER 410 Operating Instructions 22 6SE6400-5EA 00-0BP0 2.6 Overv olt age and T rip Levels The inv erter wil l protec t itself f rom both suppl y overvolta ge and undervolt age. T rip levels are sho w in T able 2-4. I ntern al overvo ltage c an occ ur during brak ing where internal voltages are f orced high by energ y ...

  • Siemens 410 - page 23

    Issue A1 2 Installati on MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 23 30 mm 100 mm 100 mm 30 mm Figure 2-5 Clearance distances for mou nting the inverter For side m ounting and UL com plia nce the am bient tem peratur e shoul d be no greater t han 40 ºC. T he m aximum output curre nt of the 7 50 W inverter is 3.2 A. Table 2-5 Dime ...

  • Siemens 410 - page 24

    2 Installati on Issue A1 MICROMASTER 410 Operating Instructions 24 6SE6400-5EA 00-0BP0 2.7.1 Mounting Brackets The MICROM ASTER 4 10 ca n be m ounted using m ount ing brac kets, wh ich are slotted i nto the heats ink at the rear of the in verter f or norm al m ounting pos ition (see Figure 2- 6 A. For s ide m ounting of the in verter the br ack ets ...

  • Siemens 410 - page 25

    Issue A1 2 Installati on MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 25 A B C D E 2.7.2 DIN Rail Mounting The DIN Rai l Mounti ng Kit c onsists of the fol lowing i tems : Ø 1 x plastic moulded base Ø 1 x plastic moulded reta ining c lip Ø 1 x Metal sprin g The DIN Rai l Mounti ng Kit is suppl ied as an option f or the in verter. I ...

  • Siemens 410 - page 26

    2 Installati on Issue A1 MICROMASTER 410 Operating Instructions 26 6SE6400-5EA 00-0BP0 2.8 Electrical Inst allation WARNING THIS EQUIPM ENT MUST BE GROUNDED. ♦ To ens ure the safe o peration of the equipm ent, it m ust be ins talled and comm issioned b y qua lified person nel in f ull com plianc e with the warn ings laid down in these oper ati ng ...

  • Siemens 410 - page 27

    Issue A1 2 Installati on MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 27 Operation with Residual Current Device If an RCD (also ref erred to as E LCB or RCC B) is fitted, t he MICROMAST ER inverter s will operate without nuisance trip ping, pro vided th at: þ A t ype B RCD is used. þ The trip lim it of the RCD is 30 m A. þ The neut ...

  • Siemens 410 - page 28

    2 Installati on Issue A1 MICROMASTER 410 Operating Instructions 28 6SE6400-5EA 00-0BP0 Removal of ‘Y’ Capacitor Link To use the i nverter o n unground ed suppl ies the ‘ Y’ capacitor ( cap) link m ust be rem oved as f ollows: 1. Ensure the inver ter has been disc onnecte d from all power suppl ies. 2. Locate the ‘Y’ Cap cover on the lef ...

  • Siemens 410 - page 29

    Issue A1 2 Installati on MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 29 Figure 2-9 Motor and Pow er Connections 2.8.3 A voiding Electro-Magnetic Interfer ence (EMI) The inv erters are d esigned to operat e in a n industr ial en vironm ent where a high level of EMI c an be exp ected. Us uall y, good inst allat ion practic es wil l ens ...

  • Siemens 410 - page 30

    2 Installati on Issue A1 MICROMASTER 410 Operating Instructions 30 6SE6400-5EA 00-0BP0 The inv erter can be screene d using the m ethodolog y shown in Figure 2- 10. Legend 1 Motor cable 2 Use suitable clips to fix motor and control cable screens securely to metal bac k plate 3 Mains pow er cable 4 Metal mounting brackets 5 Line commutati ng Ch oke ...

  • Siemens 410 - page 31

    Issue A1 3 Commis sioning MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 31 3 Commissioni ng WARNING ♦ ♦ ♦ ♦ MICROMAST ERS op erate at high voltag es. ♦ ♦ ♦ ♦ W hen operating electric al devic es, it is im possible to avoid appl ying hazardo us volta ges to c ertain p arts of the equipm ent. ♦ ♦ ♦ ♦ Emer gency St ...

  • Siemens 410 - page 32

    3 Commis sioning Issue A1 MICROMASTER 410 Operating Instructions 32 6SE6400-5EA 00-0BP0 3.1 Block Diagram Figure 3-1 Inverter bloc k diagram ...

  • Siemens 410 - page 33

    Issue A1 3 Commis sioning MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 33 3.2 Commission Modes The MICRO MAST ER 410 is suppli ed with def ault p aram eter settings c over t he follo wing: Ø T he motor rating dat a; vo ltage, curr ent an d freque ncy data is ke yed into th e inverter to ensur e that th e m otor is com patible with th ...

  • Siemens 410 - page 34

    3 Commis sioning Issue A1 MICROMASTER 410 Operating Instructions 34 6SE6400-5EA 00-0BP0 3.2.1 Commissioning without an Operator Panel The inv erter is s upplie d with an L ED to i ndicate t he opera tion stat e of the unit. The inv erter can be used with its d efault s ettings , for a num ber of applic ations . The default se ttings are s ho wn in ...

  • Siemens 410 - page 35

    Issue A1 3 Commis sioning MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 35 3.2.3 Changing the Line Supply Frequenc y The s upply frequenc y of the inverter can be ch anged us ing either the Operator Pan el or b y physica ll y cutting th e Suppl y Frequenc y Link as shown in Figure 3- 4: Cutting the supply link The line suppl y frequenc ...

  • Siemens 410 - page 36

    3 Commis sioning Issue A1 MICROMASTER 410 Operating Instructions 36 6SE6400-5EA 00-0BP0 3.2.4.1 Commissioning with the Operator Panel The O perator Pane l (OP) provid es acc ess to the inverter param eters and e nables the user t o custom ize the settings of your MICRO MAST ER 41 0. The OP c an be used to c onfigure several MICROMA STER 41 0 Invert ...

  • Siemens 410 - page 37

    Issue A1 3 Commis sioning MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 37 Buttons on the Operator Panel Panel/Button Function Effects Indicates Status T he LCD displa ys the sett ings curr entl y used b y the convert er. Start motor Pressing the button st arts the c onver ter. This button is disabled by defau lt. To en able t his butt ...

  • Siemens 410 - page 38

    3 Commis sioning Issue A1 MICROMASTER 410 Operating Instructions 38 6SE6400-5EA 00-0BP0 Changing parameters with the Operator Panel The proc edure for changi ng the va lue of param eter P0004 is desc ribed b elow. Modif ying the value of an indexe d param eter is illustr ated us ing the ex ample of P2011. F ollow exac tly the s ame proc edure to a ...

  • Siemens 410 - page 39

    Issue A1 3 Commis sioning MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 39 NOTE In som e cases - when chang ing param eter values - t he dis pla y on the Operat or Pane l shows . This means the i nverter is bus y with task s of higher pr iorit y. Changing single digits in Parameter values For chang ing the par ameter value r apidly, th ...

  • Siemens 410 - page 40

    3 Commis sioning Issue A1 MICROMASTER 410 Operating Instructions 40 6SE6400-5EA 00-0BP0 Flo w char t Quick Comm issionin g (L ev el 1 Only ) 1) Motor related paramet ers – please refer to motor rating plate. 2) Denotes parameters that c ontain m ore detail e d lists of possible setti ngs f or use in specific applicat i ons. Pleas e refer t o the ...

  • Siemens 410 - page 41

    Issue A1 3 Commis sioning MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 41 Motor d ata for pa rameter i zation Figure 3-7 T ypical M otor Rating Plate Ex ample NOTE Ø P03 08 & P 0309 are onl y visible if P0003 = 3. On ly one of the param eters is shown depe nding on the set tings of P0100 . Ø P03 07 ind icates kW or hp depending ...

  • Siemens 410 - page 42

    3 Commis sioning Issue A1 MICROMASTER 410 Operating Instructions 42 6SE6400-5EA 00-0BP0 3.3 General operation For a f ull desc ription of Level 1 to Le vel 3 par ameter s, pleas e refer to the Parameter List. NOTICE 1. The inv erter does not have a m ain po wer switch an d is li ve when th e m ains suppl y is connect ed. It waits, with t he out put ...

  • Siemens 410 - page 43

    Issue A1 3 Commis sioning MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 43 External motor thermal ov erl oad protection When oper ated bel ow rated s peed, the cooling effec t of fans f itted to the m otor shaft is reduced. Consequ entiall y, mos t motor s require de- rating for c ontinuous operatio n at lo w frequenci es. T o ensure t ...

  • Siemens 410 - page 44

    3 Commis sioning Issue A1 MICROMASTER 410 Operating Instructions 44 6SE6400-5EA 00-0BP0 ...

  • Siemens 410 - page 45

    Issue A1 4 Using th e MICRO MASTE R 41 0 MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 45 4 Using the MICROM A ST ER 410 WARNING ♦ ♦ ♦ ♦ W hen operating electric al devic es, it is im possible to avoid appl ying hazardo us volta ges to c ertain p arts of the equipm ent. ♦ ♦ ♦ ♦ Emer gency Stop f acilities accordi ng to ...

  • Siemens 410 - page 46

    4 Using th e MICRO MASTER 4 10 Iss ue A1 MICROMASTER 410 Operating Instructions 46 6SE6400-5EA 00-0BP0 4.2 Command Sources (P0700) NOTICE The ram p tim es and ram p-sm oothing func tions also aff ect how the m otor star ts and stops. For details of these f unctions, please r efer to param eters P112 0, P1121, P1130 – P 1134 in th e Param eter Lis ...

  • Siemens 410 - page 47

    Issue A1 4 Using th e MICRO MASTE R 41 0 MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 47 4.3.2 OFF2 This comm and causes the m otor to c oast to a s tandsti ll (pu lses disa bled). NOTICE The OF F2 comm and can ha ve one or mor e sources . By defaul t the OFF 2 comm and is set to O perat or Pane l. This source s till ex ists e ven if ...

  • Siemens 410 - page 48

    4 Using th e MICRO MASTER 4 10 Iss ue A1 MICROMASTER 410 Operating Instructions 48 6SE6400-5EA 00-0BP0 4.4 Control Modes (P1300) The vario us m odes of oper ation of the MICROM ASTER 4 10 contr ol the rel ation- ship bet ween the s peed of the m otor and the voltage s upp lied b y the inver ter. A summ ary of the co ntrol m odes ava ilable ar e lis ...

  • Siemens 410 - page 49

    Issue A1 5 Syste m Parame ters MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 49 5 System Parameter s 5.1 Introduction to MICROM ASTER Sy stem Par ameter s The parameters can only be changed by using the Opera tor Panel (OP) or the Serial Inte rface. Param eters can be c hanged and set us ing the O P to adj ust the d esired pr operties ...

  • Siemens 410 - page 50

    5 Syste m Parameters Issue A1 MICROMASTER 410 Operating Instructions 50 6SE6400-5EA 00-0BP0 5.2 Parameter Overv iew P0004 = 2 Inve rter Un it P0004 = 3 Mo tor Da ta P0004 = 7 Commands and Digtal I /O P0004 = 8 Analogue I/O P0004 = 1 0 Setpoint Channel & Ramp Generator P0004 = 12 Drive Features P0004 = 13 Motor Control P0004 = 20 Co mmuni cation ...

  • Siemens 410 - page 51

    Issue A1 5 Syste m Parame ters MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 51 5.3 Parameter List (short form) Explanat ory inf orm ation on f ollowin g table: Ø Default: Factor y settin g Ø Level: Access l evel ( Acc) Ø DS Inverter s tatus (Dr ive St ate), ind icates t he inver ter st ate in whic h a param eter can be m odified (s ...

  • Siemens 410 - page 52

    5 Syste m Parameters Issue A1 MICROMASTER 410 Operating Instructions 52 6SE6400-5EA 00-0BP0 Motor Data (P0004 = 3) ParNr Par Text Default Acc DS QC r0034 CO: Motor temperature (i 2 t) - 3 - - P0300 Select motor type 1 3 C Q P0304 Rated m otor voltage 230 1 C Q P0305 Rated m otor current 3.25 1 C Q P0307 Rated m otor power 0.75 1 C Q P0308 Rated m o ...

  • Siemens 410 - page 53

    Issue A1 5 Syste m Parame ters MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 53 A nalogue I/O (P0004 = 8) ParNr Par Text Default Acc DS QC r0752 Act. i nput of ADC [ V] - 3 - - P0753 Smooth time ADC 3 3 CUT N r0754 Act. ADC value aft er scal i ng [%] - 2 - - P0757 Value x1 of ADC scali ng [V] 0 3 CUT N P0758 Value y1 of ADC scali n g 0 ...

  • Siemens 410 - page 54

    5 Syste m Parameters Issue A1 MICROMASTER 410 Operating Instructions 54 6SE6400-5EA 00-0BP0 Drive Features (P0004 = 12) ParNr Par Text Default Acc DS QC P0005 Displ ay select ion 21 2 CUT N P1200 Flying start 0 3 CUT N P1202 Motor-current: Flying start 100 3 CUT N P1203 Search rate: Flying st art 100 3 CUT N P1210 Autom atic rest art 1 2 CUT N P121 ...

  • Siemens 410 - page 55

    Issue A1 5 Syste m Parame ters MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 55 Communication (P0004 = 20) ParNr Par Text Default Acc DS QC P0927 Paramet er changeable vi a 15 3 CUT N r0964[5] Firmware version data - 3 - - P0971 Transfer data from RAM to EEPROM 0 3 CUT N P2000 Reference f requenc y 50.00 3 CT N P2009[2] USS normalizati ...

  • Siemens 410 - page 56

    5 Syste m Parameters Issue A1 MICROMASTER 410 Operating Instructions 56 6SE6400-5EA 00-0BP0 ...

  • Siemens 410 - page 57

    Issue A1 6 Troub leshoot ing MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 57 6 T rouble shooting WARNING ♦ ♦ ♦ ♦ Repairs on equipm ent m ay onl y be carried o ut b y Siemens Servic e , b y repair centers au thorized by Siem ens or b y qualif ied pers onnel who are t horough ly acquainte d with al l the warn in gs and operat in ...

  • Siemens 410 - page 58

    6 Troub leshoot ing Issue A1 MICROMASTER 410 Operating Instructions 58 6SE6400-5EA 00-0BP0 6.3 Fault messages Fault Possibl e Causes Diagnose & R emedy Reac- tion F0001 OverCurrent Ø Motor power (P0307) does not correspond t o the inverter power (r0206) Ø Motor lead short circ uit Ø Earth faults Check t he following: 1. Motor power (P0307) m ...

  • Siemens 410 - page 59

    Issue A1 6 Troub leshoot ing MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 59 Fault Possibl e Causes Diagnose & R emedy Reac- tion F0060 A s ic Timeout Internal c ommunications failure If fault persist s, change inverter Contact Servi c e Department OFF2 F0071 USS (BOP- link) setpoint fault No setpoint val ues f rom USS during tele ...

  • Siemens 410 - page 60

    6 Troub leshoot ing Issue A1 MICROMASTER 410 Operating Instructions 60 6SE6400-5EA 00-0BP0 6.4 A l arms Alarm Possible C auses Diagnose & Remedy Reac- tion A 0501 Current Limit Ø Motor power does not correspond t o the inverter power Ø Motor leads are too long Ø Earth faults Check t he following: 1. Motor power (P 0307) must correspond to in ...

  • Siemens 410 - page 61

    Issue A1 6 Troub leshoot ing MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 61 Alarm Possible C auses Diagnose & Remedy Reac- tion A 0920 AD C parameters not set properly. ADC parameters should not be set to identic al values, si nce t his would produce illogical results. Check P0757, P0758, P0759 and P0760 -- A 0922 No loa d applie ...

  • Siemens 410 - page 62

    6 Troub leshoot ing Issue A1 MICROMASTER 410 Operating Instructions 62 6SE6400-5EA 00-0BP0 ...

  • Siemens 410 - page 63

    Issue A1 7 MICRO MAST ER 410 Spe ci ficatio ns MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 63 7 MICROM ASTER 410 S p ecifications Table 7-1 MICROMAST E R 410 Performan ce Ratings Feature Specification Mains Operating Volt age & Power Ranges 100 to 120 V ± 10% 1AC 0.12 kW – 0.55 k W 200 to 240 V ± 10% 1AC 0.12 kW – 0.75 kW I ...

  • Siemens 410 - page 64

    7 MICRO MAST ER 410 Spec ificat ions Issue A1 MICROMASTER 410 Operating Instructions 64 6SE6400-5EA 00-0BP0 Table 7-2 Terminal Torques – Field W irin g Connectors Motorside PE terminal Al l other t erminal s [Nm] 0.8 1 .1 Tightening Torque [lbf.in] 7. 1 9.8 Table 7-3 MICROMASTER 410 Spe c ificat ions Input voltage range 1 AC 200 V – 240 V, ± 1 ...

  • Siemens 410 - page 65

    Issue A1 7 MICRO MAST ER 410 Spe ci ficatio ns MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 65 Input voltage range 1 AC 200 V – 240 V, ± 10 % (Unfiltered) Order No. 6SE6410- 2UB11 -2AA0 2UB12 -5AA0 2UB13 -7AA0 2UB15 -5BA0 2UB17 -5BA0 [kW] 0.12 0. 25 0.37 0. 55 0.75 Motor Output Rating [hp] 0.16 0. 33 0.5 0.75 1.0 Output Current M a ...

  • Siemens 410 - page 66

    7 MICRO MAST ER 410 Spec ificat ions Issue A1 MICROMASTER 410 Operating Instructions 66 6SE6400-5EA 00-0BP0 ...

  • Siemens 410 - page 67

    Issue A1 8 Options MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 67 8 Options The f ollowing access ories are a vailab le as opt ions for your MICRO MAST ER MM410 I nverter. For mor e details p lease r efer to t he catalo gue or c ontact your loca l Siemens sale s office if you require assi stance. 8.1 V ari ant I ndependent Options Ø ...

  • Siemens 410 - page 68

    8 Options Issue A1 MICROMASTER 410 Operating Instructions 68 6SE6400-5EA 00-0BP0 ...

  • Siemens 410 - page 69

    Issue A1 9 Electro- Magnetic Comp atib ility MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 69 9 Electro-Magnetic Comp atibility (EMC) 9.1 Electro- M agnetic Comp atibilit y (EM C) All m anufactur ers / ass emblers of electr ical a pparatus which “per form s a com plete intrinsic functio n and is placed o n the m arket as a single uni ...

  • Siemens 410 - page 70

    9 Electro- Magnetic Comp atibility Issue A1 MICROMASTER 410 Operating Instructions 70 6SE6400-5EA 00-0BP0 9.1.3 EM C Directiv e Compliance with Harmonics R egulations From 1s t Januar y 2001 all e lectric al apparat us cov ered b y the EMC Directiv e will have to c ompl y with EN 6100 0-3-2 "Lim its f or harmonic current em is sions (equipm en ...

  • Siemens 410 - page 71

    Issue A1 9 Electro- Magnetic Comp atib ility MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 71 9.1.4 Genera l cases of EMC performan ce Three G eneral ca ses of EMC perf orm ance are avail able as detailed belo w: Case 1: General Industrial Complianc e with the EMC Pr oduct Sta ndard f or Po wer Drive S ystem s EN 68100-3 for us e in Se ...

  • Siemens 410 - page 72

    9 Electro- Magnetic Comp atibility Issue A1 MICROMASTER 410 Operating Instructions 72 6SE6400-5EA 00-0BP0 Case 3: Filtered - for residential, commerc i al and li ght industry This level of perf ormance wil l allo w the m anufac turer / ass embler to self- certif y complia nce of the ir appar atus wit h the EMC directi ve for the residen tial, comm ...

  • Siemens 410 - page 73

    Issue A1 Fitting the O perator Panel MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 73 A p pendice s A Fitting the Operator Panel ...

  • Siemens 410 - page 74

    Applica ble St andards Issue A1 MICROMASTER 410 Operating Instructions 74 6SE6400-5EA 00-0BP0 B A p plicable Standard s European Low Voltage Dir ective The MICROM ASTER pr oduct r ange com plies with the r equirem ents of the Low Voltage D irecti ve 73/23/EEC as am ended b y Directiv e 98/68/E EC. The u nits are certif ied for c om pliance with the ...

  • Siemens 410 - page 75

    Issue A1 List of Ab brevia tions MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 75 C List of A bbr eviations AC Alternat ing Curr ent AI N Anal og Inpu t CT Constant T orque DC Direct Current DIN Digital In put EEC European Econom ic Communit y ELCB Earth Leakage C ircuit Break er EM C Electro- Magnet ic Com patibilit y EM I Electro- Ma ...

  • Siemens 410 - page 76

    Index Issue A1 MICROMASTER 410 Operating Instructions 76 6SE6400-5EA 00-0BP0 Index A Access Levels .......................................... 49 Altitude ..................................................... 19 Ambient o perating conditi ons .................. 19 Applica ble st andards European E MC Directive ...................... 74 European Low ...

  • Siemens 410 - page 77

    Issue A1 Index MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 77 MICROMAST ER 410 available o ptions .................................. 67 general ................................................. 15 main c haracteristics ............................. 15 perform ance characteris tics ................. 16 protection ch aracteristics .... ...

  • Siemens 410 - page 78

    Index Issue A1 MICROMASTER 410 Operating Instructions 78 6SE6400-5EA 00-0BP0 ...

  • Siemens 410 - page 79

    MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 79 Suggestions and/or Co rrections Suggestions Correctio ns To: Siemens AG Automation & Driv es Group SD VM 4 P.O. Box 3269 D-91050 Erlangen Federal Republic of Germany For Pub licati on/Manual : MICROMAST ER 410 Em ail: Tec hnical.docum entatio n@con.s iemens .co.uk User Doc umentatio ...

  • Siemens 410 - page 80

    MICROMASTER 410 Operating Instructions 80 6SE6400-5EA 00-0BP0 ...

  • Siemens 410 - page 81

    Issue A1 View of Units MICROMASTER 410 Operating Instructions 6SE6400-5EA 00-0BP0 81 Vie w of Un it Standard Inv ert er Inverter with Optional Operato r Panel Fitted Key: 1. Line T erminals 2. Status L ED 3. Operator Panel Con nec tor 4. Control T erm inals 5. Motor Terminals 6. DC+/DC- Term inals Connections & Ter min al s ...

  • Siemens 410 - page 82

    Siemen s AG Bereich Automat i on and Drives (A&D) Geschäftsgebi et Standard Drives (SD) Postfach 3269, D-91050 E rl angen Federal Republic of Germany © Siem ens AG, 2001 Subject to chan ge wi tho ut pri or notice Siemens Aktieng esells chaf t Ord er No.: 6SE6 400-5EA 00-0BP 0 Date: 10/0 1 Order Num ber *6SE6400-5EA00-0BP0* ...

Manufacturer Siemens Category Microscope & Magnifier

Documents that we receive from a manufacturer of a Siemens 410 can be divided into several groups. They are, among others:
- Siemens technical drawings
- 410 manuals
- Siemens product data sheets
- information booklets
- or energy labels Siemens 410
All of them are important, but the most important information from the point of view of use of the device are in the user manual Siemens 410.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Siemens 410, service manual, brief instructions and user manuals Siemens 410. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Siemens 410.

Similar manuals

A complete manual for the device Siemens 410, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Siemens 410 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Siemens 410.

A complete Siemens manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Siemens 410 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Siemens 410, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Siemens 410, that we can find in the current document
3. Tips how to use the basic functions of the device Siemens 410 - which should help us in our first steps of using Siemens 410
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Siemens 410
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Siemens 410 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Siemens 410?

Use the form below

If you did not solve your problem by using a manual Siemens 410, ask a question using the form below. If a user had a similar problem with Siemens 410 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)