Manual A&D UT-302PBT

24 pages 0.75 mb
Download

Go to site of 24

Summary
  • A&D UT-302PBT - page 1

    PBT DIGIT AL BL UETOO TH THEROMETER ...

  • A&D UT-302PBT - page 2

    Inde x 1 2 3 3 4 5 6 7 10 11 14 14 15 15 16 18 Introduction Important Information Befor e Us e Produc t I dentification Description of LC D Display Battery Installation Changing Modes (°C/°F S witchable) T ips fo r M easuring Huma nT emperatur e M easuring Body Te m peratur e in th e Ear Memory F unction Car e an d Maintenanc e A pplied Standards ...

  • A&D UT-302PBT - page 3

    1 Introduction Utilizing infrared technology , t his t hermomete r take s temperatures in seconds by m easuring h eat g enerated by th e ea r c anal or other objects .T his produc t c onforms to th e provisions of th e EC directiv e MDD(93/42/EEC).Its advantages include: 1. Wireles s communication : B luetoot h (clas s 2) 2. Intended use: Fo r home ...

  • A&D UT-302PBT - page 4

    2 Important Information Before Us e W hen using t his product, p leas e be sure to f ollow all th e notes listed below .A ny action agains t t hes e notices ma y c aus e injur y or affect th e a ccuracy . 1. Do not disassemble, r epair , or remodel th e t hermomete r. 2. Be sure to c lean th e t hermomete r l ens each time a fte r usage. 3. Av oid ...

  • A&D UT-302PBT - page 5

    Produc t Identification Probe Ti p P ower & M easur e Butto n LCD Display MEMO RY Recall Butto n Battery compartment lid Description of LC D Displa y Degrees of Te m peratur e Celsius Scale F ahrenheit Scale Sca n in Progres s Low battery Wa r ning Memory Symbol and Sets of Records Smiling face I ndicating temperatur e is lower t han 38° C ( 1 ...

  • A&D UT-302PBT - page 6

    Battery Installation Low battery w arning: W hen th e battery power becomes low , th e low battery symbol “” will a ppear on th e display .T he t hermomete r ca n still be used during t his time , bu t the batteries s hould be replaced as s oon as possible. If th e batteries ru n ou t completely ,“ Lo” will be displayed a long with th e lo ...

  • A&D UT-302PBT - page 7

    5 Changing Mode s (°C/°F Switchable ) T his t hermomete r ca n display result in either degrees F ahrenheit(°F) or degrees Celsius(°C) . Changing °C / °F , p leas e mak e sur e th e device is in power on condition. Pres s th e Power/Sca n button, hold it , an d t hen pres s th e Memor y butto n to t oggle between °C an d °F . ...

  • A&D UT-302PBT - page 8

    6 T ips fo r Measuring Human T emperatur e B ear in mind t hat th e t hermomete r needs to have b een in th e room in w hic h th e measurement is take n fo r at leas t 30 minutes befor e use. •S om e p eople produc e di ff erent r eadings in t heir lef t and right ea r. In order to recor d temperatur e c hanges , a lway s m easur e a person’ s ...

  • A&D UT-302PBT - page 9

    M easuring B ody T emperatur e in the Ear 2. Pres s th e Power butto n to switch th e t hermomete r on. F ollowing a successful self test , th e device emit s tw o shor t b eeps . 3. Make sur e t hat th e sensor ti p an d also th e ea r c anal ar e clean. As th e ea r c anal is s lightly curved, yo u hav e to p ull th e ea r s lightly up an d backw ...

  • A&D UT-302PBT - page 10

    5. Yo u may take ou t th e device to read th e m easurement result . 6. Th e backlight display will remain l ight fo r approximately 5 seconds eac h time the “Power & M easure” butto n is pressed, a fte r eac h reading is completed, an d each time the “Memory” butto n is presse d to recall a previous r eading. 7. Th e t hermomete r will ...

  • A&D UT-302PBT - page 11

    M easuring B ody T emperatur e in the Ear 9 The R eadings : If th e temperatur e measurement is below 38°C , a “Smiling Face ” will be a ppear nex t to th e reading. If th e reading is 38° C or above, a “Frowning Face ” will be displayed. ...

  • A&D UT-302PBT - page 12

    1. W hile in p ower on mode, pres s onc e briefly on th e “Memory” button, t hen pass it a gain to show th e last m easurement a ccompanied by “” symbol. 2. C ontinue to pres s the “Memory” butto n to view th e nex t previously stored measurement , so “” t hen al l th e wa y to “” . 10 M emory F unction Yo u can recall up to 10 ...

  • A&D UT-302PBT - page 13

    11 Operating Th e B luetoot h F unction 1. Tu rn th e ea r t hermomete r to th e back s ide. 2. Tu rn on th e wireles s power (Fro m "o ff " to "on"), while th e t hermomete r s earches fo r other B luetoot h compatible devices, th e LE D (connection i ndicator ) will f lash. W hen th e device connects successfully to healt h mo ...

  • A&D UT-302PBT - page 14

    12 Operating Th e B luetoot h F unction Wha tY ou N eed : Th e host computer or terminal s ystem to run Serial Port Profile ( SPP) -A personal computer wit h O perating s ystem : W indows 95 or later -A Smart P hone with A ndroid s ystem - Others: PDA, etc. Pleas e refer to th e instruction manual of y our personal computer fo r how to install Seri ...

  • A&D UT-302PBT - page 15

    13 Operating Th e B luetoot h F unction Communications Interface: To connec t to a ne w device (new master ) the must be ou t of r ange fro m th e previous master or unpaired fro m t hat master . UT-302PBT Using Bluetooth communications terms, the UT -302PBT is a slave device. T o connect the UT -302PBT to a master device you must initiate the conn ...

  • A&D UT-302PBT - page 16

    14 Care an d Maintenance • Clean th e probe an d ti p with an alcohol swab before an d a fte r eac h measurement . Probe an d T ip: • Us e a soft, dr y c lot h to clean t hermomete r body . Neve r us e abrasiv e cleaning a gents, t hinner s or benzene fo r c leaning. Do no t s cratc h th e surface of th e probe l ens or th e display . Do no t e ...

  • A&D UT-302PBT - page 17

    • 34°C~43° C ( 93.2°F~109.4°F) • 35.5°C~42° C ( 95.9°F~107.6°F) : outside th e r ange: • 16 C~35 C ( 60. 8F ~9 5F ) wit h r elativ e humidit y up to 85 % ( non c ondensing) • -2 5C ~+5 5C (-1 3F ~+131 F) wit h r elativ e humidit y up to 85 % ( non c ondensing) • 0.1 C or F • 2 x 1.5 V AAA alkaline batteries • approx . 70 g ( w ...

  • A&D UT-302PBT - page 18

    16 FC C Statemen t T his equipment ha s been tested an d f ound to comply wit h th e limits fo r a C las s B d igital device , pursuant to Part 15 of th e FC C R ules . T hes e limits ar e designed to provide reasonable protection a gains t harmful interferenc e in a residential installation. T his equipment g enerates , uses , an d can radiat e ra ...

  • A&D UT-302PBT - page 19

    17 FC C Statemen t 6. T his devic e complies wit h Par t 15 of th e FC C R ules . O peration is s ubjec t to th e f ollowing tw o conditions : (1 ) t his devic e may not c aus e harmful interference, and (2) t his devic e mus t a ccept an y interferenc e received, including interferenc e t hat ma y c aus e undesired o peration. 7. T his devic e com ...

  • A&D UT-302PBT - page 20

    18 EMC Ta ble s Guidanc e an d manufacturer's d eclaration-electromagneti c emission The intended fo r us e in th e e lectromagnetic environment s pecified below .T he customer or th e user of the should a ssure t hat it is used in such an environment . Thermometer Thermometer Emissions t est Complianc e Electromagneti c environmen t guidanc e ...

  • A&D UT-302PBT - page 21

    19 EMC Ta ble s Guidanc e an d manufacturer's d eclaration-electromagneti c i mmunit y The is intended fo r us e in th e electromagnetic environment specified below. T he customer or th e user of the should a ssure t hat it is used in such an environment . Thermometer Thermometer I mmunit y test IE C 6 0601 t est l evel Complianc e l evel Elec ...

  • A&D UT-302PBT - page 22

    20 EMC Ta ble s Recommende d separation distances between portable an d m obile RF communications e quipmen t an d the Thermometer The monitor is intended fo r us e in an e lectromagnetic environment in whic h r adiated RF disturbances ar e c ontrolled. Th e customer or th e user of th e ca n h elp prevent e lectromagnetic interferenc e by m aintai ...

  • A&D UT-302PBT - page 23

    This device includes RF transmitter (with wireless communication) 21 ...

  • A&D UT-302PBT - page 24

    A&D Company, Limited 1-243 As ahi , K itamoto -s hi , S aitama 364-8585 JAPA N Telephone: [81](48)593-1111 Fax: [81](48)593-1119 A&D INSTRUMENTS LTD. Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon , Oxfordshire O X14 1DY United Kingdom Telephone: [44](1235)550420 Fax: [44](1235)550485 A&D ENGINEERING, INC. 1756 A utomation ...

Manufacturer A&D Category Thermometer

Documents that we receive from a manufacturer of a A&D UT-302PBT can be divided into several groups. They are, among others:
- A&D technical drawings
- UT-302PBT manuals
- A&D product data sheets
- information booklets
- or energy labels A&D UT-302PBT
All of them are important, but the most important information from the point of view of use of the device are in the user manual A&D UT-302PBT.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals A&D UT-302PBT, service manual, brief instructions and user manuals A&D UT-302PBT. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product A&D UT-302PBT.

Similar manuals

A complete manual for the device A&D UT-302PBT, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use A&D UT-302PBT by users. Manuals are usually written by a technical writer, but in a language understandable to all users of A&D UT-302PBT.

A complete A&D manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual A&D UT-302PBT - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the A&D UT-302PBT, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the A&D UT-302PBT, that we can find in the current document
3. Tips how to use the basic functions of the device A&D UT-302PBT - which should help us in our first steps of using A&D UT-302PBT
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with A&D UT-302PBT
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of A&D UT-302PBT in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning A&D UT-302PBT?

Use the form below

If you did not solve your problem by using a manual A&D UT-302PBT, ask a question using the form below. If a user had a similar problem with A&D UT-302PBT it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)