  • Agilent Technologies 34970A - page 1

    4XLFN5H IHUHQF H*XLGH SCPI Co mmand Summa ry The following conventions are used for SCPI command syntax for remote interface programming: • Square brackets ( [ ] ) indicate o ptional keywords o r parameters. • Braces ( { } ) enclose parameter choices with in a command string. • Triangle brackets ( < > ) enclose parameters for whic ...

  • Agilent Technologies 34970A - page 2

    Scan Measurement Commands ( see page 226 in the User’s Gu ide ) MEASure :TEMPerature? { TCoup le |RTD|FRTD|THERmi stor|DEF} ,{< type >|DEF}[,1[,{< resolution >|MIN|MAX|DEF}]] ,( @ < scan_list >) :VOLTage:DC? [{< range >| AUTO |MIN| MAX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) :VOLTage:AC? [{< ...

  • Agilent Technologies 34970A - page 3

    Scan Configuration Commands ( see page 226 in the User’s Gu ide ) ROUTe :SCAN ( @ < scan_list >) :SCAN? :SCAN:SIZE? TRIGger : SOU Rce {B U S | IMMediate |EXTernal|ALA Rm1|ALARm2|ALARm3|ALARm4 |TIMer} :SOURce? TRIGger :TIMer {< seconds >| MIN |MAX} :TIMer? TRIGger :COUNt {< count >| MIN |MAX|INFi nity} :COUNt? ROUTe :CHANnel:DELa ...

  • Agilent Technologies 34970A - page 4

    Scanning With an External Instrument ( see page 239 in the User’s Gu ide ) ROUTe :SCAN ( @ < scan_list >) :SCAN? :SCAN:SIZE? TRIGger :SOURce {BUS|IMMediate|EXT ernal| TIMer } :SOURce? TRIGger :TIMer {< seconds >| MIN |MAX} :TIMer? TRIGger :COUNt {< count >|MIN|MAX| INFi nity } :COUNt? ROUTe :CHANnel:DELay < seconds >[,( @ ...

  • Agilent Technologies 34970A - page 5

    Temperature Configuration Commands ( see page 219 in the User’s Gu ide ) CONFigure :TEMPerature { TCoupl e |RTD|FRTD|THERmis tor|DEF} ,{< type >|DEF}[,1[,{< resolution >|MIN|MAX|DEF}]] ,( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] UNIT :TEMPerature { C |F|K}[,( @ < ch_list >)] :TEMPerature? [( @ < ch_list > ...

  • Agilent Technologies 34970A - page 6

    Voltage Configuration Commands ( see page 223 in the User’s Gu ide ) CONFigure :VOLTage:DC [{< range >| AUTO |MIN|M AX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:] VOLTage:DC:RANGe {< range >|MIN|MAX}[, ( @ < ch_list >)] VOLTage:DC:RANGe? [{( @ < ch_list &g ...

  • Agilent Technologies 34970A - page 7

    Resistance Configuration Commands ( see page 224 in the User’s Gu ide ) CONFigure :RESistance [{< range >| AUTO |MIN|M AX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:] RESistance:RANGe {< range >|MIN|MAX}[, ( @ < ch_list >)] RESistance:RANGe? [{( @ < ch_list ...

  • Agilent Technologies 34970A - page 8

    Current Configuration Commands ( see page 224 in the User’s Gu ide ) Valid only on channels 21 and 22 on the 34901A mul tiplexer module. CONFigure :CURRent:DC [{< range >| AUTO |MIN|M AX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:] CURRent:DC:RANGe {< range >|MIN|MA ...

  • Agilent Technologies 34970A - page 9

    Frequency a nd Period Configuration Commands ( see page 214 in the User’s Gu ide ) CONFigure :FREQuency [{< range >| AUTO |MIN|MA X|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:] FREQuency:VOLTage:RANGe {< range >|MIN|MAX}[,( @ < ch_list >) ] FREQuency:VOLTage:R ...

  • Agilent Technologies 34970A - page 10

    Mx+B Scalin g Commands ( see page 244 in the User’s Gu ide ) CALCulate :SCALe:GAIN < gain >[ ,( @ < ch_list >)] :SCALe:GAIN? [( @ < ch_list >)] :SCALe:OFFSet < offset >[,( @ < ch_list >)] :SCALe:OFFSet? [( @ < ch_list >)] :SCALe:UNIT < quot ed_ strin g >[,( @ < ch_ list >)] :SCALe:UNIT? [( @ < ch ...

  • Agilent Technologies 34970A - page 11

    Digital Input Commands ( see page 255 in the User’s Gu ide ) Ch 01 DIO (L SB) Ch 0 2 DIO (MSB ) Ch 03 Totalizer Ch 04 DAC Ch 05 DAC CONFigure:DIGital:BYTE ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:]DIGital:DATA:{ BYT E |WORD}? [( @ < ch_lis t >)] Totalizer Commands ( see page 256 in the User’s Gu ide ) Ch 01 DIO ...

  • Agilent Technologies 34970A - page 12

    Switch Control Commands ( see page 259 in the User’s Gu ide ) ROUTe :CLOSe ( @ < ch_list >) :CLOSe:EXCLusive ( @ < ch_list >) :CLOSe? ( @ < ch_lis t >) ROUTe :OPEN ( @ < ch_list >) :OPEN? ( @ < ch_list >) ROUTe:DONE? SYSTem:CPON {100|200|300|ALL } Scan Triggering Commands ( see page 228 in the User’s Gu ide ) TRIGg ...

  • Agilent Technologies 34970A - page 13

    System-Related Commands ( see page 264 in the User’s Gu ide ) SYSTem :DATE < yyyy > , < mm > ,< dd > :DATE? :TIME < hh >,< mm >,< ss.sss > :TIME? FORMat :READing:TIME:TYPE {ABSolu te| RELative } :READing:TIME:TYPE? *IDN? SYSTem:CTYPe? {100|200|300} DIAGnostic :POKE:SLOT:DATA {100|200|3 00}, < quoted_string & ...

  • Agilent Technologies 34970A - page 14

    Status System Commands ( see page 286 in the User’s Gu ide ) *STB? *SRE < enable _value > *SRE? STATus :QUEStionable:CONDition? :QUEStionable[:EVENt]? :QUEStionable:ENABle < ena ble_value > :QUEStionable:ENABle? *ESR? *ESE < enable _value > *ESE? STATus :ALARm:CONDition? :ALARm[:EVENt]? :ALARm:ENABle < en able_value > :ALA ...

  • Agilent Technologies 34970A - page 15

    Service-Related Commands ( see page 294 in the User’s Gu ide ) INSTrument :DMM {OFF|ON} :DMM? :DMM:INSTalled? DIAGnostic :DMM:CYCLes? :DMM:CYCLes:CLEar (1|2|3} DIAGnostic :RELay:CYCLes? [( @ < ch_list >)] :RELay:CYCLes:CLEar [( @ < ch_list >)] *RST SYSTem:PRESet SYSTem:CPON {100|200|300|ALL } SYSTem:VERSion? *TST? IEEE 488.2 Co mmon C ...

  • Agilent Technologies 34970A - page 16

    Agilent 34901A 20-Channel Multiplexer ( see page 164 in the User’s Gu ide ) Agilent 34902A 16-Channel Multiplexer ( see page 166 in the User’s Gu ide ) 16 ...

  • Agilent Technologies 34970A - page 17

    Agilent 34903A 20-Channel Act uator ( see page 168 in the User’s Gu ide ) Agilent 34904A 4x8 Matrix ( see page 170 in the User’s Gu ide ) 17 ...

  • Agilent Technologies 34970A - page 18

    Agilent 34905A/6A Dual 4- Channel RF Multiplexers ( see page 172 in the User’s Gu ide ) Agilent 34908A 40-Channel Single-Ended Mul tiplexer ( see page 174 in the User’s Gu ide ) 18 ...

  • Agilent Technologies 34970A - page 19

    Agilent 34907A Mult ifunction Module ( see page 176 in the User’s Gu ide ) 19 ...

  • Agilent Technologies 34970A - page 20

    Factory Reset State The table below shows the state of the instrument after a FACTORY RESET from the Sto/Rcl menu or *RST command from the remote interface. Measurement Configurati on Fu ncti on Range Res olu tio n Inte gration Time Input Re sistance Channel D elay Totalizer Rese t Mode Tota lize r Edge De tect Scanning Oper atio ns Scan L ist Read ...

Manufacturer Agilent Technologies Category Switch

Documents that we receive from a manufacturer of a Agilent Technologies 34970A can be divided into several groups. They are, among others:
- Agilent Technologies technical drawings
- 34970A manuals
- Agilent Technologies product data sheets
- information booklets
- or energy labels Agilent Technologies 34970A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Agilent Technologies 34970A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Agilent Technologies 34970A, service manual, brief instructions and user manuals Agilent Technologies 34970A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Agilent Technologies 34970A.

A complete manual for the device Agilent Technologies 34970A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Agilent Technologies 34970A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Agilent Technologies 34970A.

A complete Agilent Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Agilent Technologies 34970A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Agilent Technologies 34970A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Agilent Technologies 34970A, that we can find in the current document
3. Tips how to use the basic functions of the device Agilent Technologies 34970A - which should help us in our first steps of using Agilent Technologies 34970A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Agilent Technologies 34970A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Agilent Technologies 34970A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Agilent Technologies 34970A?

Use the form below

If you did not solve your problem by using a manual Agilent Technologies 34970A, ask a question using the form below. If a user had a similar problem with Agilent Technologies 34970A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)