Manual Intel SC450NX

24 pages 0.16 mb
Download

Go to site of 24

Summary
  • Intel SC450NX - page 1

    SC450NX MP Server Rack/Pedestal Kit Installation Guide Order Number: 711917-001a ...

  • Intel SC450NX - page 2

    Intel Corporation (Intel) makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Intel assumes no responsibility for any errors that may appear in this document. Intel makes no commitment to update nor to keep current the information ...

  • Intel SC450NX - page 3

    Copyright  1998, Intel Corporation. All Rights Reserved. ...

  • Intel SC450NX - page 4

    ...

  • Intel SC450NX - page 5

    v Safety Guidelines Before you remove a server cover, observe these safety guidelines: • Only technically qualified personnel should integrate the server. • Turn off all peripheral devices connected to the server. • Turn off the server using the push-button on/off power switch on the front panel of the server, and unplug the AC power cord fro ...

  • Intel SC450NX - page 6

    vi CAUTIONS E LECTROSTATIC DISCHARGE (ESD) AND ESD PROTECTION : ESD can damage disk drives, add-in boards, and other components. This server can withstand normal levels of environmental ESD while hot -swapping SCSI hard disk drives. However, we recommend doing all procedures in this manual only at an ESD-protected workstation. If one is not availab ...

  • Intel SC450NX - page 7

    vii Equipment Rack Precautions WARNINGS A NCHOR THE EQUIPMENT RACK : The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The anchors must be able to withstand a force of up to 113 kg (250 lbs). You must also consider the weight of any o ...

  • Intel SC450NX - page 8

    viii ...

  • Intel SC450NX - page 9

    ix Contents Safety Guidelines Server Precautions ............................................................................................................... v Equipment Rack Precautions .............................................................................................. vii Introduction Tools You Need ................................. ...

  • Intel SC450NX - page 10

    x ...

  • Intel SC450NX - page 11

    11 Introduction The SC450NX MP server is designed to either stand upright (pedestal mode) or be mounted in a rack (rack mode). Figures 1 and 2 on page 12 show examples of these configurations. Before operation, you must purchase an adapter kit to configure the server for one of the two modes. If you have already created a pedestal server but now wa ...

  • Intel SC450NX - page 12

    12 Table 1 . SC450NX MP Server Physical Specifications Specification Pedestal Mode Rack Mode Height 48.26 cm (19 inches) 7u Width 31.12cm (12.25 inches) 19 inch rack Depth 63.5cm (25 inches) 25 inches Weight 38.25 kg (85 lbs) minimum configuration 45 kg (100 lbs) maximum configuration 38.25 kg (85 lbs) minimum configuration 45 kg (100 lbs) maximum ...

  • Intel SC450NX - page 13

    13 Configuring for Rack Mount Before starting, please read “ Safety Guidelines ” on page v . Prepare the Slide Assemblies See Figure 3 . 1. Remove the slide assemblies from the kit. 2. Orient a slide assembly so that the smallest outer bar is facing down. 3. Fully extend the telescoping slide assembly until the center bar hits the safety latch ...

  • Intel SC450NX - page 14

    14 Prepare the Server Before you can install the server in the 19-inch equipment rack, you must install a bezel, handles, and the small bars of the slide assemblies onto the sides of the server. Attaching the Bezel Frame and Door To be installed in a rack, the server needs a bezel frame with rectangular cutouts where the chassis handles fit. 1. Att ...

  • Intel SC450NX - page 15

    15 Attach the Small Bar of the Slide Assembly to the Server See Figure 4 . 1. Remove four screws from the kit. 2. While facing the side of the server, orient the small bar so that the flat side faces the top and the right-angle end faces the front of the server. 3. Align the first hole in the right-angle end of the bar with the first threaded hole ...

  • Intel SC450NX - page 16

    16 Prepare the Equipment Rack Before you can install the server in the 19-inch equipment rack, you must attach the center bar and large outer bar assemblies to the vertical rails of the rack. Attach the Right-angle Extension Brackets to the Equipment Rack / NOTE Mounting holes in the vertical rails of equipment racks are commonly spaced in a 5/8 x ...

  • Intel SC450NX - page 17

    17 Attach the Center Bar and Large Outer Bar Assemblies to the Equipment Rack See Figure 6 . 1. Orient a center bar and large outer bar assembly so that the flat side is facing toward the brackets attached to the vertical rails and the safety latch on the center bar is near the back of the rack. 2. Press the flat side of the outer bar into the U -s ...

  • Intel SC450NX - page 18

    18 Install the Server in the Rack WARNINGS A NCHOR THE EQUIPMENT RACK : The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The anchors must be able to withstand a force of up to 113 kg (250 lbs). You must also consider the weight of an ...

  • Intel SC450NX - page 19

    19 1 Small outer bar 2 Center bar 3 Large outer bar 4 Safety latch Figure 7 . Installing the Server in the Rack ...

  • Intel SC450NX - page 20

    20 ...

  • Intel SC450NX - page 21

    21 Configuring for Pedestal Mount Install Chassis Feet See Figure 8 . 1. Remove two system feet and two screws from the kit. 2. Each system foot has one screw hole and, on the opposite end, two slots that fit two tabs extending from the chassis wall. Orient the chassis foot to align these features with their corresponding parts of the chassis wall. ...

  • Intel SC450NX - page 22

    22 Install Bezel Frame and Door 1. Attach the bezel frame by inserting the tabs at the corner of the frame into their corresponding rectangular slots on the chassis. 2. Attach the bezel door: with the door all the way open (left, as it stands upright in a pedestal mount), align the tabs on the door with their corresponding hinge loops on the chassi ...

  • Intel SC450NX - page 23

    23 Changing from Pedestal to Rack To change your server from pedestal mode to rack mode, you must complete two basic steps: removing the components of the pedestal mount, then configuring the server for a rack mount. Because configuring for a rack mount was described in an earlier section (page 13 ), this section covers only a few details unique to ...

  • Intel SC450NX - page 24

    24 Exchange the Bezel Frame To be installed in a rack, the server needs a new bezel frame with rectangular cutouts where the chassis handles fit. You need to remove the old bezel frame and install the new one from the rack kit. 1. Remove the bezel door: with the door open all the way (to the left), lift it upward to release it from its hinges on th ...

Manufacturer Intel Category Life Jacket

Documents that we receive from a manufacturer of a Intel SC450NX can be divided into several groups. They are, among others:
- Intel technical drawings
- SC450NX manuals
- Intel product data sheets
- information booklets
- or energy labels Intel SC450NX
All of them are important, but the most important information from the point of view of use of the device are in the user manual Intel SC450NX.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Intel SC450NX, service manual, brief instructions and user manuals Intel SC450NX. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Intel SC450NX.

Similar manuals

A complete manual for the device Intel SC450NX, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Intel SC450NX by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Intel SC450NX.

A complete Intel manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Intel SC450NX - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Intel SC450NX, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Intel SC450NX, that we can find in the current document
3. Tips how to use the basic functions of the device Intel SC450NX - which should help us in our first steps of using Intel SC450NX
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Intel SC450NX
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Intel SC450NX in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Intel SC450NX?

Use the form below

If you did not solve your problem by using a manual Intel SC450NX, ask a question using the form below. If a user had a similar problem with Intel SC450NX it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)