    Installation Manual 20002514, Rev BA December 2010 Micro Motion ® R-Series Coriolis Flow Sensors ...

  • Emerson 20002514 - page 2

    Safety and approval information This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this manual. Refer to the EC declaration of conformity for directives that apply to this product. The EC declaration of conformity, with all applicable European directives, and the ...

  • Emerson 20002514 - page 3

    Contents Chapter 1 Planning ...........................................................................................................................1 1.1 Installation checklist ........................................................................................................................1 1.2 Best practices ............................. ...

  • Emerson 20002514 - page 4

    Contents ii Micro Motion R-Series ...

  • Emerson 20002514 - page 5

    1 Planning Topics covered in this chapter: • Installation checklist • Best practices • Environmental limits 1.1 Installation checklist □ Make sure that the hazardous area specified on the sensor approval tag is suitable for the environment in which the sensor is installed. □ Verify that the local ambient and process temperatures are withi ...

  • Emerson 20002514 - page 6

    Recommended sensor orientation Table 1-3: Liquids Gases Slurries □ Install the sensor so that the flow direction arrow on the sensor matches the actual forward flow of the process. 1.2 Best practices The following information can help you get the most from your sensor. • There are no pipe run requirements for Micro Motion sensors. Straight runs ...

  • Emerson 20002514 - page 7

    Environmental limits for R-Series sensors Figure 1-1: Maximum process temperature in °F (°C) 176 (80) 140 (60) 104 (40) 68 (20) 32 (0) –4 (–20) –40 (–40) –148 (–100) 158 (70) Ambient temperature of core processor or transmitter in °F (°C) –112 (–80) –76 (–60) –40 (–40) –4 (–20) 32 (0) 68 (20) 104 (40) 140 (60) 176 (8 ...

  • Emerson 20002514 - page 8

    2 Mounting 2.1 Mount the sensor Use your common practices to minimize torque and bending load on process connections. Tip To reduce the risk of condensation or excessive moisture, the conduit opening should not point upward (if possible). The conduit opening of the core processor can be rotated freely to facilitate wiring. Procedure Mount the senso ...

  • Emerson 20002514 - page 9

    3 Wiring Topics covered in this chapter: • Options for wiring • Connect 4-wire cable 3.1 Options for wiring The wiring procedure you follow depends on which electronics option you have. See Table 3-1 for the wiring options for each sensor electronics option. Wiring procedures by electronics option Table 3-1: Electronics option Wiring procedure ...

  • Emerson 20002514 - page 10

    Step 1: Cable preparation Cable layout Run conduit to sensor Metal conduit Wrap the drain wires twice around the shield and cut off the excess drain wires. Micro Motion cable gland Pass the wires through the gland Cable glands Remove the core processor cover Go to Step 2 Go to Step 3 Gland supplier User-supplied cable gland Lay cable in conduit Dra ...

  • Emerson 20002514 - page 11

    Step 2: Shield termination Assemble the Gland 1. Fold the shield or braid back over the clamping insert and 1/8 inch (3 mm) past the O-ring. 2. Install the gland body into the conduit opening on the core processor housing. 3. Insert the wires through gland body and tighten the gland nut onto the gland body. Apply the Heat Shrink 1. Slide the shield ...

  • Emerson 20002514 - page 12

    Step 3: Terminal connections Connect the wires to the transmitter terminals (see the transmitter manual) Reinstall and tighten the core processor cover From Step 1 or 2 Connect the wires to the core processor terminals: Red wire > Terminal 1 (Power supply +) Black wire > Terminal 2 (Power supply –) White wire > Terminal 3 (RS-485/A) Gree ...

  • Emerson 20002514 - page 13

    4 Grounding The sensor must be grounded according to the standards that are applicable at the site. The customer is responsible for knowing and complying with all applicable standards. Prerequisites Micro Motion suggests the following guides for grounding practices: • In Europe, IEC 79-14 is applicable to most installations, in particular Section ...

  • Emerson 20002514 - page 14

    *20002514* 20002514 Rev BA 2010 Micro Motion Inc. USA Worldwide Headquarters 7070 Winchester Circle Boulder, Colorado 80301 T +1 303-527-5200 T +1 800-522-6277 F +1 303-530-8459 www.micromotion.com Micro Motion Europe Emerson Process Management Neonstraat 1 6718 WX Ede The Netherlands T +31 (0) 318 495 555 F +31 (0) 318 495 556 www.micromotion.nl M ...

Manufacturer Emerson Category Stud Sensor

Documents that we receive from a manufacturer of a Emerson 20002514 can be divided into several groups. They are, among others:
- Emerson technical drawings
- 20002514 manuals
- Emerson product data sheets
- information booklets
- or energy labels Emerson 20002514
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson 20002514.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson 20002514, service manual, brief instructions and user manuals Emerson 20002514. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson 20002514.

Similar manuals

A complete manual for the device Emerson 20002514, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson 20002514 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson 20002514.

A complete Emerson manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson 20002514 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson 20002514, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson 20002514, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson 20002514 - which should help us in our first steps of using Emerson 20002514
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson 20002514
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emerson 20002514 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emerson 20002514?

Use the form below

If you did not solve your problem by using a manual Emerson 20002514, ask a question using the form below. If a user had a similar problem with Emerson 20002514 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)