  • Omron CP1E-E@@D@-@ - page 1

    INSTRUC TIONS REFERENCE MANUAL C at. No. W4 83 -E1 -03 SYSMAC CP Serie s CP1E-E @@ D @ - @ CP1E-N @@ D @ - @ CP1E-NA @@ D @ - @ CP1E CPU Unit ...

  • Omron CP1E-E@@D@-@ - page 2

     OMRO N, 2009 All rights reser ved. No part of th is publication m ay be reproduc ed, stored in a retrieval syste m, or transmitte d, in any form, or by any m eans, mechanic al, electron ic, photoco pying, recordin g, or othe rwise, without th e prior written pe rmission of OMRON. No paten t liability is assum ed with respe ct to the use of t he ...

  • Omron CP1E-E@@D@-@ - page 3

    SYSMAC CP Series CP1E-E @@ D @ - @ CP1E-N @@ D @ - @ CP1E-NA@@D@ - @ CP1E CPU Unit Instructi ons Re ference M anual Revised Decem ber 2 009 ...

  • Omron CP1E-E@@D@-@ - page 4

    1 CP1E CPU Unit Instructions Reference Manual(W483) Intr oduction Thank y ou f or purchasing a SYSMAC CP-series CP1E Programmable Controller . This manual conta ins info r mation required to use th e CP1E. Read this man ual completely and be sure you understand the contents bef ore attempting to use the CP1E. This manual is intended fo r the f ollo ...

  • Omron CP1E-E@@D@-@ - page 5

    2 CP1E CPU Unit Instructions Reference Manual(W483) CP1E CPU Unit Man uals Inf or mation on the CP1E CPU Units is provided in the f ollowing man uals. Ref er to the appropriate man ual f or the inf ormation that is required. This Manual Mounting and Setting Hardware 1 2 3 4 5 6 7 Wiring Connecting Online to the PLC Software Setup Creating the Progr ...

  • Omron CP1E-E@@D@-@ - page 6

    3 CP1E CPU Unit Instructions Reference Manual(W483) The CP1E CPU manuals are organized in the sections listed in the f ollo wing tables. Ref er to t he appro- priate section in the manuals as required. Manual Configuration CP1E CPU Unit Instructions Reference Man ual (Cat. No. W483) (This Manual) Section Contents Section 1 Summary of Instructions T ...

  • Omron CP1E-E@@D@-@ - page 7

    4 CP1E CPU Unit Instructions Reference Manual(W483) Section 15 Anal og I/O Functi on This section describes the built-in analog function for NA-type CPU Units. Section 16 Buil t-in Functions This section describes PID temperatur e control, cloc k functions, DM backup functions , secur ity functions. Section 17 Operating the Program- ming Device Thi ...

  • Omron CP1E-E@@D@-@ - page 8

    5 CP1E CPU Unit Instructions Reference Manual(W483) Man ual Structure The f ollowing page structure a nd icons are used in this manual. Special information in this manual is classified as f ollows: P age Structure and Icons Special Inf ormation 5 - 3 5 Installation and wiring CP1E CPU Unit Hardware User’s Man ual(W479) 5 5-2 Installation 5-2-1 In ...

  • Omron CP1E-E@@D@-@ - page 9

    6 CP1E CPU Unit Instructions Reference Manual(W483) T erminology and Notation Te r m Description E-type CPU Unit A basic model of CPU Unit tha t suppor t basic control appli cations using instr uctions such as basic, mov ement, arithmetic, and comparison instructions. Basic models of CPU Units are called “E-type CPU Units” in this manual. N-typ ...

  • Omron CP1E-E@@D@-@ - page 10

    7 CP1E CPU Unit Instructions Reference Manual(W483) Sections in this Man ual 1 2 3 4 1 2 3 4 Summary of Instructions A Appendices Instructions Instruction Execution Times and Number of Steps Monitoring and Computing the Cyc le Time A ...

  • Omron CP1E-E@@D@-@ - page 11

    8 CP1E CPU Unit Instructions Re f erence M anual(W483) CONTENTS Intr oduction .......... ................... .................. ................... ................... .......................... 1 CP1E CPU Unit M anuals .................. ................... .................. ................... ................. 2 Man ual Structu re .. .......... ...

  • Omron CP1E-E@@D@-@ - page 12

    9 CP1E CPU Unit Instructions Reference Manual(W483) CNTR/CNTRX ..... .............. .............. ................. .............. ................ .............. .............. ........ ............... ...... 2-83 CNR/CNRX ....................................................... ............................................................... .... ...

  • Omron CP1E-E@@D@-@ - page 13

    10 CP1E CPU Unit Instructions Reference Manual(W483) XOR W/XORL ....... .............. .............. ................. .............. .............. ................. .............. ...... .................... 2 -214 COM/COML ... ................. .............. .............. ................. .............. .............. ................. ..... ...

  • Omron CP1E-E@@D@-@ - page 14

    11 CP1E CPU Unit Instructions Reference Manual(W483) Other Instructions ............. ................. ................ ............. ................ ................ ................ .. ........... 2-398 STC/CLC ....... ................. .............. .............. ................. .............. .............. ................. ..... ....... ...

  • Omron CP1E-E@@D@-@ - page 15

    12 CP1E CPU Unit Instructions Reference Manual(W483) Read and Understand this Manual Please read and understand this manual bef ore using the product. Ple ase consult y our OM RON representativ e if you hav e any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON’ s e xclusive w arranty is that the products are free from ...

  • Omron CP1E-E@@D@-@ - page 16

    13 CP1E CPU Unit Instructions Reference Manual(W483) Application Considerations SUITABILITY FOR USE OMRON shall not be responsib le f or conformity with any standards, codes, or regulat ions that apply to the combination of pr oducts in the customer’ s application or use of the products. At the customer’ s request, OMRON will provide applicable ...

  • Omron CP1E-E@@D@-@ - page 17

    14 CP1E CPU Unit Instructions Reference Manual(W483) Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accesso ries may be changed at an y time based on improv ements and other reasons. It is our practice to change model nu mbers when pub lished ratings or f eatures are changed, or when significant construction ch anges are made. Ho w ...

  • Omron CP1E-E@@D@-@ - page 18

    15 CP1E CPU Unit Instructions Reference Manual(W483) Safety Precautions The f ollowing notation is used in this man ual to prov ide precautions required to ensure saf e usage of a CP-series PLC. The saf ety pr ecautions that are provided are e xtremely impor tant to safe ty . Alw ays read and heed the inf or mation prov ided in all saf ety precauti ...

  • Omron CP1E-E@@D@-@ - page 19

    16 CP1E CPU Unit Instructions Reference Manual(W483) Be sure to sufficiently confirm the safet y at the destination when y ou transfer the program or I/O memory or perf orm proc edures to change the I/O memory . De vices connec ted to PLC outputs may incor rectly operate regardless of the operat- ing mode of the CPU Unit. With an E-type CPU Unit or ...

  • Omron CP1E-E@@D@-@ - page 20

    17 CP1E CPU Unit Instructions Reference Manual(W483) Progra m so that the memory area of the start ad dress is not excee ded when using a wo rd add ress or symbol for t he offset. F or e xample, write the program so th at processing is e xecuted only when the indirect specification does not caus e th e final addres s to e xceed the memor y area by ...

  • Omron CP1E-E@@D@-@ - page 21

    18 CP1E CPU Unit Instructions Reference Manual(W483) Precautions f or Safe Use Obser v e the f ollowing precauti ons when using a CP-series PLC.  Handling • T o initialize the DM Area, back up the initial co ntents f or the DM Area to backup memory using one of the f ollowing methods . • Set the number of words of the DM Area to be bac ked u ...

  • Omron CP1E-E@@D@-@ - page 22

    19 CP1E CPU Unit Instructions Reference Manual(W483) Regulations and Standar ds SYSMA C is a registered trademark for Prog rammable Controllers made b y OMRON Corporation. CX-One is a registered tradem ark f or Progr amming Software ma de b y OMRON Corporation. Windows is a registered trademark of Microsoft Corporation. Other system names and prod ...

  • Omron CP1E-E@@D@-@ - page 23

    20 CP1E CPU Unit Instructions Reference Manual(W483) Related Man uals The f ollowing manuals are relat ed to the CP1E. Use them together with this manual. Manual name Cat. No. Model numbers Appli cation Contents SYSMA C CP Series CP1E CPU Unit Instruc- tions Ref erence Manual (this manual) W483 CP1E- E  D  -  CP1E- N  D  -  ...

  • Omron CP1E-E@@D@-@ - page 24

    ...

  • Omron CP1E-E@@D@-@ - page 25

    1-1 CP1E CPU Unit Instructions Reference Manual(W483) 1 This section pro vides a summar y of instructions used with a CP1E CPU Unit. 1-1 Summary of Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Summar y of Instructions ...

  • Omron CP1E-E@@D@-@ - page 26

    1 Summar y of Instr uctions 1-2 CP1E CPU Unit Instructions Reference Manual(W483) 1-1 Summar y of Instructions There are 200 types of instructions can be used by CP1E. The following table li sts the instruction s by function. Refer to the reference p ages for the detail o f each instruction. Instrucion Ty p e Instruction Mnemonic FUN No. Function P ...

  • Omron CP1E-E@@D@-@ - page 27

    1-3 1 Summar y of Instructions CP1E CPU Unit Instructions Reference Manual(W483) 1-1 Summary of Instructions 1 Sequence Output Instructions OUTPUT OUT - Outputs the result (e xecution condition) of the logical processing to the speci- fied bit. 2-18 !OUT - OUTPUT NO T OUT NOT - Rev erses the result (e x ecution condition) of the logical processing, ...

  • Omron CP1E-E@@D@-@ - page 28

    1 Summar y of Instr uctions 1-4 CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructi ons END END 001 Indicates the end of a prog ram. 2-38 NO OPERA TION NOP 000 This instruction has no function. (No processing is perf or med for NOP(000 ).) 2-39 INTERLOCK IL 002 Interloc ks all outputs between IL( 002) and ILC(003) when the ...

  • Omron CP1E-E@@D@-@ - page 29

    1-5 1 Summar y of Instructions CP1E CPU Unit Instructions Reference Manual(W483) 1-1 Summary of Instructions 1 Comparison Instructions Sy mb ol Co m par i so n = , <> , < , <= , > , >= 300 ∼ 328 Symbol comparison instructions compare two values and create an ON e xecu- tion condition when the compa rison condition is true. 2-88 ...

  • Omron CP1E-E@@D@-@ - page 30

    1 Summar y of Instr uctions 1-6 CP1E CPU Unit Instructions Reference Manual(W483) Data Shift Instructi ons SHIFT REGISTER SFT 010 Operates a shif t register . 2-127 REVERSIBLE SHIFT REGISTER SFTR/ @SFTR 084 Creates a shift re gister that shifts data to either the right or the left. 2-129 WORD SHIFT WSFT/ @WSFT 016 Shifts data betw een St and E in w ...

  • Omron CP1E-E@@D@-@ - page 31

    1-7 1 Summar y of Instructions CP1E CPU Unit Instructions Reference Manual(W483) 1-1 Summary of Instructions 1 Symbol Math Instructions SIGNED BINAR Y ADD WITHOUT CARR Y +/ @+ 400 Adds 4-digit (si ngle-word) he xadecimal data and/or constant s. 2-158 DOUBLE SIGNED BINAR Y ADD WITHOUT CARR Y +L/ @+L 401 Adds 8-digit (doub le-word) hexade cimal data ...

  • Omron CP1E-E@@D@-@ - page 32

    1 Summar y of Instr uctions 1-8 CP1E CPU Unit Instructions Reference Manual(W483) Conv ersion Instructi ons BCD T O BINARY BIN/ @BIN 023 Conver ts BCD data to binar y d ata. 2-185 DOUBLE BCD T O DOUBLE BINAR Y BINL/ @BINL 058 Conv ert s 8-digit BCD data to 8-digit he xadecimal (32-bit binary) data. 2-185 BINAR Y TO BCD BCD/ @BCD 024 Conv erts a wor ...

  • Omron CP1E-E@@D@-@ - page 33

    1-9 1 Summar y of Instructions CP1E CPU Unit Instructions Reference Manual(W483) 1-1 Summary of Instructions 1 Floating-point Math Instr uc- tions FLOA TING TO 16-BIT FIX/ @FIX 450 Conv er ts a 32-bit floating-poin t value to 16-bi t signed binary data and places the result in the specified result w ord. 2-233 FLOA TING TO 32-BIT FIXL/ @FIXL 451 Co ...

  • Omron CP1E-E@@D@-@ - page 34

    1 Summar y of Instr uctions 1-10 CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter and Pulse Output Instructi ons MODE CONTROL INI/ @INI 880 INI(880) is used to start and stop target v alue comparison, to change the present va lue (PV) of a high-speed counter , to change the PV of an interrupt input (counter mode ), to change t h ...

  • Omron CP1E-E@@D@-@ - page 35

    1-11 1 Summar y of Instructions CP1E CPU Unit Instructions Reference Manual(W483) 1-1 Summary of Instructions 1 Other Instructions SET CARR Y STC/ @STC 040 Sets the Carry F lag (CY). 2-398 CLEAR CARR Y CLC/ @CLC 041 T ur ns OFF the Carr y Flag (CY). 2-398 EXTEND MAXIMUM CYCLE TIME WDT/ @WDT 094 Extends the maximum cycle time, but only f or the cycl ...

  • Omron CP1E-E@@D@-@ - page 36

    1 Summar y of Instr uctions 1-12 CP1E CPU Unit Instructions Reference Manual(W483) ...

  • Omron CP1E-E@@D@-@ - page 37

    2-1 CP1E CPU Unit Instructions Reference Manual(W483) 2 This section describes the functi ons, operands and sample progr ams of the instruc- tions that are suppor ted by a CP1E CPU Unit. Notation and Lay out of Instruction Descriptions . . . . . . . . . . . . . . . . . . . . 2-2 Sequence Input Instruct ions . . . . . . . . . . . . . . . . . . . . . ...

  • Omron CP1E-E@@D@-@ - page 38

    2 Instructions 2-2 CP1E CPU Unit Instructions Reference Manual(W483) Notation and La y out of Instruction Descriptions Instructions are described in g roups b y function. Re fe r to Appendix A List of Instructions b y Function Code f or a list of instructions by mnemonic that lists the page nu mber in this section f o r each instru c- tion. The des ...

  • Omron CP1E-E@@D@-@ - page 39

    2-3 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Notation and Layout of Instruction Descriptions 2 Constants Constants input f or operands are given as listed belo w . Operand Descr iptions and Operand Specif ications • Operands Specifying Bit Strings (Normally Input as Hexadecimal): Only the he xadecimal f orm is giv en f or ...

  • Omron CP1E-E@@D@-@ - page 40

    2 Instructions 2-4 CP1E CPU Unit Instructions Reference Manual(W483) Condition Flags With the CX-Programmer , the condition flags are re gistered in adv ance as glob al symbols with “P_” in front of the symbol na me. Symbol Instructions Some of the C/CV -ser ies PLC instructio ns hav e been changed to diff erent instr uctions with the same func ...

  • Omron CP1E-E@@D@-@ - page 41

    2-5 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Input Instructio ns 2 Sequence Input Instructions Differentiated and Immed iate Refreshing Instructions • The LO AD , AND , and OR instructions ha ve diff erent iated and immediate refresh ing v ariations in addi- tion to their ordinar y forms, and th ere are als o two ...

  • Omron CP1E-E@@D@-@ - page 42

    2 Instructions 2-6 CP1E CPU Unit Instructions Reference Manual(W483) Operation Timing f or I/O Instructions The f ollowing char t shows the diff er ences in the timing of instr uction operation s for a prog ram config- ured from LD and OUT . A A A A A A A A A A A A B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 ! ! ! ! ! A B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B1 ...

  • Omron CP1E-E@@D@-@ - page 43

    2-7 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Input Instructio ns 2 LD/LD NO T LD/LD NO T Applicable Pr ogram Areas Operands  Operand Specifications Flag s There are no flags aff e cted by this instruc tion. Function  LD LD is used f or the first normally open bit from the bus bar or f or the first normally ope ...

  • Omron CP1E-E@@D@-@ - page 44

    2 Instructions 2-8 CP1E CPU Unit Instructions Reference Manual(W483) Hint • LD/LD NO T is used in the follo wing circumstances as an instruction for indicating a logical star t. 1. When directly connectin g to the bus bar . 2. When logic bloc ks are connected by AND LD or OR LD , i.e., at the beginning of a logic bloc k. The AND LO AD and OR LOAD ...

  • Omron CP1E-E@@D@-@ - page 45

    2-9 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Input Instructio ns 2 AND/AND NO T AND/AND NO T Applicable Pr ogram Areas Operands  Operand Specifications Flag s There are no flags aff e cted by this instruc tion. Function  AND AND is used fo r a nor mally open bit connected in series. AND cannot be directly conn ...

  • Omron CP1E-E@@D@-@ - page 46

    2 Instructions 2-10 CP1E CPU Unit Instructions Reference Manual(W483) Precautions • Diff erentiate up (@) or differentiate do wn (%) can be specified f or AND . If differentiate up (@) is spec- ified, the e xecution condition is turned ON for one cycle only afte r the status of the operand bit goes from OFF to ON. If differentiate do wn (%) is sp ...

  • Omron CP1E-E@@D@-@ - page 47

    2-11 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Input Instructio ns 2 OR/OR NOT OR/OR NO T Applicable Pr ogram Areas Operands  Operand Specifications Flag s There are no flags aff e cted by this instruc tion. Function Instruction Mnemonic V ariations Function code Function OR OR @OR, %OR, !OR, !@OR, !%OR --- T akes ...

  • Omron CP1E-E@@D@-@ - page 48

    2 Instructions 2-12 CP1E CPU Unit Instructions Reference Manual(W483) Precautions • Diff erentiate up (@) or differentiate do wn (%) can be specified f or OR. If diff erentiate up (@) is speci- fied, the e x ecution condition is tu rn ed ON f or one cycle only after the status of the operand bit goes from OFF to ON. If differentiate do wn (%) is ...

  • Omron CP1E-E@@D@-@ - page 49

    2-13 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Input Instructio ns 2 AND LD/OR LD AND LD/OR LD Applicable Pr ogram Areas Flag s There are no flags aff e cted by this instruc tion. Function Hint Instruction Mnemonic V ariations Function code Function AND LOAD AND LD --- --- T akes a logical AND between logic b locks. ...

  • Omron CP1E-E@@D@-@ - page 50

    2 Instructions 2-14 CP1E CPU Unit Instructions Reference Manual(W483) Precautions When a logic bl ock is connected b y AND LOAD or OR LO AD instructions, the total number of AND LOAD/OR LO AD instr uctions must match the total number of LOAD/LO AD NO T instructions minus 1. If they do not match, a programming error will occur .  AND LD In the fo ...

  • Omron CP1E-E@@D@-@ - page 51

    2-15 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Input Instructio ns 2 AND LD/OR LD Sample pr ogram  AND LD i • The AND LO AD instruction can be used repea tedly . In prog ramming method (2) abov e, howe ver , the number of AND LO AD instruction s becomes one less than the number of LO AD and LOAD NO T instruction ...

  • Omron CP1E-E@@D@-@ - page 52

    2 Instructions 2-16 CP1E CPU Unit Instructions Reference Manual(W483) NO T Applicable Pr ogram Areas Flags There are no flags affected by NO T(520). Function NO T(520) is placed between an e x ecutio n condition and another instruction to inv e r t the e xecution con- dition. Precautions NO T(520) is an inter mediate instr uction, i.e., it cannot b ...

  • Omron CP1E-E@@D@-@ - page 53

    2-17 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Input Instructio ns 2 UP/DOWN UP/DO WN Applicable Pr ogram Areas Flag s There are no flags aff ect ed by UP(521) and DOWN(522). Function Precautions • The operation of UP(52 1) and DOWN(522) depends on the e xecution condition f or the instru ction as well as the e x e ...

  • Omron CP1E-E@@D@-@ - page 54

    2 Instructions 2-18 CP1E CPU Unit Instructions Reference Manual(W483) Sequence Output Instructions OUT/OUT NO T Applicable Pr ogram Areas Operands  Operand Specifications Flags There are no flags affected b y this instruction. Function Instruction Mnemonic V ariations Functio n code Function OUTPUT OUT !OUT - -- Outputs the result (ex ecution co ...

  • Omron CP1E-E@@D@-@ - page 55

    2-19 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Output I nstructions 2 OUT/OUT NOT Hint • Immediate refreshin g (!) can be specified f or OUT and OUT NO T . An immediate refresh instruction updates the status of the b uilt-in output term inal ju st after the instruction is ex ecuted for the CPU Unit, at the same tim ...

  • Omron CP1E-E@@D@-@ - page 56

    2 Instructions 2-20 CP1E CPU Unit Instructions Reference Manual(W483) TR Function TR bits are used to temporarily retain the ON/OFF status of ex ecution conditions in a program when progra mming in mnemonic code . They are not used when prog ramming directly in ladder prog ram f or m because the processing is au tomatically e x ecuted by the P e ri ...

  • Omron CP1E-E@@D@-@ - page 57

    2-21 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Output I nstructions 2 KEEP KEEP Applicable Pr ogram Areas Operands  Operand Specifications Flag s No flags are aff e cted by KEEP(011). Function Instruction Mnemonic V ariations Function code Function KEEP KEEP !KEEP 011 Operates like a latching rela y . Symbol KEEP ...

  • Omron CP1E-E@@D@-@ - page 58

    2 Instructions 2-22 CP1E CPU Unit Instructions Reference Manual(W483) Hint • KEEP(011) has an immediate refreshing v ariation (!KEEP(011)). When a CPU Unit built-in output bit has been specified f or R in a !KEEP(011) instr uction, any changes to R will be refreshed when !KEEP(011) is e x ecuted and reflected immediately in the output bit. • KE ...

  • Omron CP1E-E@@D@-@ - page 59

    2-23 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Output I nstructions 2 KEEP • If a holding bit is used f or R, the bit status will be retained e v en during a power interruption. KEEP(011) can thus be used to program bits that will maintain status after restar ting the PLC f ollow- ing a pow er interr uption. An e x ...

  • Omron CP1E-E@@D@-@ - page 60

    2 Instructions 2-24 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram Coding Note KEEP(011) is input in different orders on in ladder and mnemonic form. In ladder form, input the set input, KEEP(011), and then the reset input. In mnemo nic f or m, input the se t input, the reset input, a nd then KEEP(011). When CIO 0.00 g oes ON in ...

  • Omron CP1E-E@@D@-@ - page 61

    2-25 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Output I nstructions 2 DIFU DIFU Applicable Pr ogram Areas Operands  Operand Specifications Flag s No flags are aff ected b y DIFU(013). Function Hint Instruction Mnemonic V ariations Function code Function DIFFERENTIA TE UP DIFU !DIFU 013 DIFU(013) turns the d esigna ...

  • Omron CP1E-E@@D@-@ - page 62

    2 Instructions 2-26 CP1E CPU Unit Instructions Reference Manual(W483) Precautions • The operation of DI FU(013) depends on the e xec ution condition f or the instr uct ion itself as well as the e x ecution condition for the program section when it is programmed in an inte rloc ked prog ram section, a jumped prog ram section, or a subr outine. • ...

  • Omron CP1E-E@@D@-@ - page 63

    2-27 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Output I nstructions 2 DIFD DIFD Applicable Pr ogram Areas Operands  Operand Specifications Flag s No flags are aff ected b y DIFD(014). Function Hint Instruction Mnemonic V ariations Function code Function DIFFERENTIA TE DOWN DIFD !DIFD 014 DIFD(014) turns the d esig ...

  • Omron CP1E-E@@D@-@ - page 64

    2 Instructions 2-28 CP1E CPU Unit Instructions Reference Manual(W483) Precautions • The operation of DIFD(014) will not be consistent if the same function b lock instance is e xecuted more than once in th e same cycle. • An subroutine will not be e xecuted while the input condition f or the subroutine is OFF . Caution is thus required when usin ...

  • Omron CP1E-E@@D@-@ - page 65

    2-29 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Output I nstructions 2 SET/RSET SET/RSET Applicable Pr ogram Areas Operands  Operand Specifications Flag s No flags are aff ected by SET and RSET . Function Instruction Mnemonic V ariations Functio n code Function SET SET @SET , %SET , !SET , !@SET , !%SET --- SET tur ...

  • Omron CP1E-E@@D@-@ - page 66

    2 Instructions 2-30 CP1E CPU Unit Instructions Reference Manual(W483) Hint • Diff erences between OUT/ OUT NO T and SET/RSET The operation of SET diff ers from that of OUT be cause the OUT instruction tur ns the operand bit OFF when its ex ecuti on condition is OFF . Lik ewise , RSET dif f ers from OUT NO T because OUT NO T turns the operand bit ...

  • Omron CP1E-E@@D@-@ - page 67

    2-31 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Output I nstructions 2 SET A/RST A SET A/RST A Applicable Pr ogram Areas Operands  Operand Specifications Flag s Function Instruction Mnemonic V ariations F unction code Function MUL TIPLE BIT SET SET A @SET A 530 SET A(530) turns ON the specified number of consecutiv ...

  • Omron CP1E-E@@D@-@ - page 68

    2 Instructions 2-32 CP1E CPU Unit Instructions Reference Manual(W483) Hint  SET A • SET A(530) can be used to tur n ON bits in data areas that are no rmally accessed by words only , such as the DM areas .  RST A • RST A(531) can be used to tur n OFF bits in data areas that ar e normally accessed by words only , such as the DM areas. Sampl ...

  • Omron CP1E-E@@D@-@ - page 69

    2-33 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Output I nstructions 2 SETB/RSTB SETB/RSTB Applicable Pr ogram Areas Operands  Operand Specifications Flag s Function Instruction Mnemonic V ariations F unction code Function SINGLE BIT SET SETB @SETB, !SETB, !@SETB 532 SETB(532) turns ON the specified bit. SINGLE BIT ...

  • Omron CP1E-E@@D@-@ - page 70

    2 Instructions 2-34 CP1E CPU Unit Instructions Reference Manual(W483) Hint • Diff erences between SET/R SET and SETB(532)/RSTB(533) The instructions operate in the sa me w ay when the specified bit is in the CIO , W , H, or A Area. The SETB(532) and RSTB(53 3) instructions can contr ol bits in the DM Ar eas , unlike SET and RSET . • The set and ...

  • Omron CP1E-E@@D@-@ - page 71

    2-35 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructions 2 Sequence Contr ol Instructions Overview of Interloc k Instructions  Interloc k Instructions The f ollowing instruction combinations can be used to interlock outputs in a program section. • INTERLOCK and INTERLOCK CLEAR (IL(002) and IL(003)) ? ...

  • Omron CP1E-E@@D@-@ - page 72

    2 Instructions 2-36 CP1E CPU Unit Instructions Reference Manual(W483)  Differences between MILH(517) and MILR(518) Diff erentiated instru ctions (DIFU, DIFD , or instructions with a @ or % prefix) operate diff erently in inter- locks cre ated with MI LH(517) and MILR(518). The operation of diff erentiat ed instructions in an inter lock created w ...

  • Omron CP1E-E@@D@-@ - page 73

    2-37 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructions 2  Differences between Interloc ks and Jumps The f ollowing tab le shows the diff erences between interlocks (c reated with IL(002)/ILC(003), MILH(517)/MILC(5 19), or MILR(518)/MI LC(519)) and jumps crea ted with JMP( 004)/JME(005). Item T reatmen ...

  • Omron CP1E-E@@D@-@ - page 74

    2 Instructions 2-38 CP1E CPU Unit Instructions Reference Manual(W483) END Applicable Pr ogram Areas Flags There are no flags affected b y this instruction. Function END(001) completes the ex ec ution of a program f or t h at cycle. No instructions wr itten after END(001) will be ex ecuted. Precautions • Alwa ys place END(001) at the end of each p ...

  • Omron CP1E-E@@D@-@ - page 75

    2-39 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructions 2 NOP NOP Applicable Pr ogram Areas Flag s No flags are aff ected b y NOP(000). Function • No processing is perf or med f or NOP(000) , but this instruction can be used to set aside lines in the program where instructions will be inser ted later . ...

  • Omron CP1E-E@@D@-@ - page 76

    2 Instructions 2-40 CP1E CPU Unit Instructions Reference Manual(W483) IL/ILC Applicable Pr ogram Areas Flags There are no flags affected b y this instruction. Function When the e x ecution condition f or IL (002) is OFF , the outputs for a ll instructions between IL(002) and ILC(003) are interlocked. When the e xecution condition f or IL(002 ) is O ...

  • Omron CP1E-E@@D@-@ - page 77

    2-41 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructions 2 IL/ILC Hint Precautions • The cycle time is not shor tened when a section of the program is inter lock ed because the inter lock ed instructions are ex ecuted internally . • In general, IL(002) and ILC(003) are used in pair s , although it is p ...

  • Omron CP1E-E@@D@-@ - page 78

    2 Instructions 2-42 CP1E CPU Unit Instructions Reference Manual(W483)  Operation of Differentiated Instructions If there is a diff erentia ted instruction (DIFU , DIFD , or instruction prefixed b y @ or %) between IL(002) and ILC(003) instructions, that instruction will be e x ecuted when the interlock is cleared if the diff erenti- ation condit ...

  • Omron CP1E-E@@D@-@ - page 79

    2-43 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructions 2 IL/ILC Sample pr ogram When CIO 0.00 is OFF in the right e xample, all outputs betw een IL(002) and ILC(00 3) are inte rlock ed. When CIO 0.00 is ON in the right e xample, the instructions between IL(0 02) and ILC(003) are e x ecuted nor mally . IL ...

  • Omron CP1E-E@@D@-@ - page 80

    2 Instructions 2-44 CP1E CPU Unit Instructions Reference Manual(W483) MILH/MILR/MILC Applicable Pr ogram Areas Operands N: Interloc k Number The interlock n umber must b e between 0 and 15. Ma tch the inte rlock number of the MILH(517) (or MILR(518)) instruction with the same number in t he corresponding MILC (519) instru ction. The interlock numbe ...

  • Omron CP1E-E@@D@-@ - page 81

    2-45 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructions 2 MILH/MILR/MILC Function When the e x ecution condition f or MI LH(517) (or MILR(518)) with interlock number N is OFF , the outputs f or all instructions between that MILH(517)/MI LR(518) instruction and the ne xt MILC(519) with interlock number N a ...

  • Omron CP1E-E@@D@-@ - page 82

    2 Instructions 2-46 CP1E CPU Unit Instructions Reference Manual(W483) • A1 and A2 are interlocked when the Emergency Stop Button is ON . • A2 is interloc ked when Conv eyor R U N is OFF . Example 2 Interlocking the entire progr am with one condition and interlocking two ov erlapping par ts of the program with other conditions (2 nesting lev els ...

  • Omron CP1E-E@@D@-@ - page 83

    2-47 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructions 2 MILH/MILR/MILC  Differences between MILH(517) and MILR(518) Diff erentiated instructions (DIFU, DIFD , or instructions with a @ or % prefix) oper ate differently in inter- locks created with MI LH(517) and MILR(518). When a program section is in ...

  • Omron CP1E-E@@D@-@ - page 84

    2 Instructions 2-48 CP1E CPU Unit Instructions Reference Manual(W483)  Operation of Differentiated Instructions in an MILR(518) Interloc k If there is a differentiated instruction (DIFU, DI FD , or instr uction with a @ or % prefix) between MILR(518) and the corresponding MILC(519), that instruction will not be ex ecuted after the interlock is c ...

  • Omron CP1E-E@@D@-@ - page 85

    2-49 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructions 2 MILH/MILR/MILC Hint • The cycle time is not shor tened wh en a section of the progr am is interlocked b y MILH(517) or MILR(518) because the interlock ed instructions are ex ecuted inter nally . • When nesting interloc ks, assign interloc k num ...

  • Omron CP1E-E@@D@-@ - page 86

    2 Instructions 2-50 CP1E CPU Unit Instructions Reference Manual(W483) • If there is an ILC(003) instruction between an MILR(518) and MILC(519) pair , the ILC(003) instruction will be ignored and the full progr am section between MILR(518) and MILC(519) will be interlocked. • If there is another MI LH(5 17) or MILR(518) instruction with the same ...

  • Omron CP1E-E@@D@-@ - page 87

    2-51 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructions 2 MILH/MILR/MILC • Progr am operation can be s witched more efficie ntly by using interlocks wit h MILH(517) or MILR(518). Instead of s witching pr ocessing with compound conditions, insert an MILH (517) or MILR(518) instruction before each process ...

  • Omron CP1E-E@@D@-@ - page 88

    2 Instructions 2-52 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram When W0.00 and W0.01 are both ON, the instructions betw een MILH(517) with interlock n umber 0 and MILC(519) with interlock number 0 are e xecuted normally . When W0.00 is OFF , the instructions between MILH(517) with inte rlock number 0 and MILC(519) with interlo ...

  • Omron CP1E-E@@D@-@ - page 89

    2-53 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructions 2 JMP/CJP/JME JMP/CJP/JME Applicable Pr ogram Areas Operands N: J ump Number The jump number must be 0000 to 007F (&0 to &127 decimal).  Operand Specifications Flag s  JMP/CJP  JME There are no flags aff e cted by this instruc tion. ...

  • Omron CP1E-E@@D@-@ - page 90

    2 Instructions 2-54 CP1E CPU Unit Instructions Reference Manual(W483) Function Hint • Because all of instru ctions between JM P(004)/CJP(510) and JME( 005) are skipped when the ex ecu- tion condition f or JMP(004 ) is OFF , the cycle time is reduced by th e total e x ecution time of the skipped instructions. In contrast, processing time equiv ale ...

  • Omron CP1E-E@@D@-@ - page 91

    2-55 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructions 2 JMP/CJP/JME Sample pr ogram • When there are two or more JME(005) instruc- tions with the same jump number , only the instruction with the lower address will be v alid. The JME(005) with th e higher progr am address will be ignored. • CJP(510) ...

  • Omron CP1E-E@@D@-@ - page 92

    2 Instructions 2-56 CP1E CPU Unit Instructions Reference Manual(W483) FOR/NEXT Applicable Pr ogram Areas Operands N: Number of loops The number of loop s must be 0000 to FFFF (0 to 65,535 decimal).  Operand Specifications Flags Function Instruction Mnemonic V ariations Functio n code Function --- FOR --- 512 The instructions between FOR(512) and ...

  • Omron CP1E-E@@D@-@ - page 93

    2-57 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructions 2 FOR/NEXT Hint There are two w ays to repeat a program section until a giv en e xecution con dition is input. • FOR-NEXT Loop with BREAK Star t a FOR-NEXT loop with a maximum of N repetitions. Progr am BREAK(514) within the loop with the desired e ...

  • Omron CP1E-E@@D@-@ - page 94

    2 Instructions 2-58 CP1E CPU Unit Instructions Reference Manual(W483) • A jump instruction such as JMP(004) may be e x ecuted within a FOR-NEXT loop , but do not jump bey ond the FOR-NEXT loop . • The f ollowing instructions cann ot be used within FOR-NEXT loops: • STEP DEFINE and STEP ST AR T: STEP(008)/SNXT(009) Sample pr ogram &3 Break ...

  • Omron CP1E-E@@D@-@ - page 95

    2-59 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Sequence Control Instructions 2 BREAK BREAK Applicable Pr ogram Areas Flag s Function Precautions • A BREAK(514) instr uction cancels only one loop , so sev eral BREAK(514) instructions (the number of le vels nested) are required to escape from nested loops. • BREAK(514) can ...

  • Omron CP1E-E@@D@-@ - page 96

    2 Instructions 2-60 CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions Refresh Methods f or Timer/Counter PV  Overview There are two PV refr esh methods f or instr uction s related to timer/coun ters, “BCD” and “BINAR Y”. The PLC Setup f or all of the timer/count er-related instr uctions. The refresh method ...

  • Omron CP1E-E@@D@-@ - page 97

    2-61 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2  Operating Mode Item TIM/TI MX (550) TIMH(015)/ TIMHX(551) TMHH(540)/ TMHHX(552) TTIM(087)/ TTIMX(555) TIML(542)/ TIMLX(553) Operating mode chang e PV = 0 Completion Flag = OFF --- P ower interr upt/reset PV = 0 Completion Flag = OFF --- Execut ...

  • Omron CP1E-E@@D@-@ - page 98

    2 Instructions 2-62 CP1E CPU Unit Instructions Reference Manual(W483)  Example Timer and Counter Applications Example 1: Long-term Timers The f ollowing progr am e xamples show three w a ys to create long-ter m timers wit h standard TIM and CNT instructions. 1) T wo TIM Instructions In this e xample, two T IM instru ctions ar e combined to mak e ...

  • Omron CP1E-E@@D@-@ - page 99

    2-63 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2 Example 2: T wo-stage Counter When an SV higher than 999 9 is required, tw o counters can be combined as sho wn in the f ollowing e xample. In this case , two CNT instructions are combined to mak e a BCD counter with an SV of 20,000. Example 3: ON ...

  • Omron CP1E-E@@D@-@ - page 100

    2 Instructions 2-64 CP1E CPU Unit Instructions Reference Manual(W483) Example 4: One-shot Bit A TIM timer can be combined with OUT or OUT NO T to control how long a particular bit is ON or OFF . In this example , CIO 2.04 will be ON for 1.5 seconds (the SV of T0001) after CIO 0.00 goes ON. Example 5: Flic ker Bit 1) T wo TIM Instructions T wo TIM t ...

  • Omron CP1E-E@@D@-@ - page 101

    2-65 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2 2) Clock Pulse The desired ex ecution condition can be combined wit h a clock pulse to mi mic the cloc k pulse (0.1 s, 0.2 s, or 1.0 s).  Timer reset method There are two methods f or resetting a timer ins truction. 1. T urn OFF the execution c ...

  • Omron CP1E-E@@D@-@ - page 102

    2 Instructions 2-66 CP1E CPU Unit Instructions Reference Manual(W483) TIM/TIMX Applicable Pr ogram Areas Operands N: Timer Number The timer numb er must be betw een 0000 and 0255 (decimal). S: Set V alue (100-ms Units) TIM (BCD): #0 000 to #9999. TIMX (Binary): &0 to &65535 (d ecimal) or #0000 to #FFFF (he x).  Operand Specifications Fla ...

  • Omron CP1E-E@@D@-@ - page 103

    2-67 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2 TIM/TIMX Function Hint • A TIM/TIMX(550) instruction’ s PV and Completion Flag can be refreshed in the follo wing wa ys depending on the timer number that is used. Precautions • Timer numbers are shared with other timer instructions. If tw o ...

  • Omron CP1E-E@@D@-@ - page 104

    2 Instructions 2-68 CP1E CPU Unit Instructions Reference Manual(W483) *1 If the IOM Hold Bit (A500.12) has been tur ned ON, the statu s of timer Comple tion Flags and PVs will b e maintained when the operating mode is changed. *2 The PV will be set to the SV when TIM/TIMX(550) is e x ecuted. • When TIM/TIMX(550 ) is in a progr am section be tween ...

  • Omron CP1E-E@@D@-@ - page 105

    2-69 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2 TIMH/TIMHX TIMH/TIMHX Applicable Pr ogram Areas Operands N: Timer Number The timer number must be between 00 00 and 0255 (decimal). S: Set V alue TIMH (BCD): #0000 to #9999 TIMHX (Binary): &0 to &65535 (decimal) or #000 0 to #FFFF (he x ) ...

  • Omron CP1E-E@@D@-@ - page 106

    2 Instructions 2-70 CP1E CPU Unit Instructions Reference Manual(W483) Function Hint A TIMH(015)/TIMHX(551) instruction’ s PV and Completion Flag can be refreshed in the f ollowing wa ys depending on the timer n umber that is used. Precautions • Timer numbers are share d with other timer instructions. If two timers share the same timer n umber , ...

  • Omron CP1E-E@@D@-@ - page 107

    2-71 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2 TIMH/TIMHX *1 If the IOM Hold Bit (A500.12) has be en turned ON, the status o f timer Completion Flags and PVs wil l be maintained when the operating mode is changed. *2 The PV will be set to the SV when TIMH(015)/TIMHX(551) is e xecuted. • When ...

  • Omron CP1E-E@@D@-@ - page 108

    2 Instructions 2-72 CP1E CPU Unit Instructions Reference Manual(W483) TMHH/TMHHX Applicable Pr ogram Areas Operands N: Timer Number The timer must be betw een 0000 and 0015 decimal. S: Set V alue TMHH (BCD): #0000 to #9999 TMHHX (Binary): &0 to &65 535 (decimal) or #0 000 to #FFFF (hex)  Operand Specifications Flags Function • When the ...

  • Omron CP1E-E@@D@-@ - page 109

    2-73 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2 TMHH/TMHHX • The setting range f or the set v alue (SV) is 0 to 9.999 s f o r TMHH(540) and 0 to 65.535 f or TMHHX(552). • The timer accuracy is -0.01 to 0 s. Hint The timer PV and timeup used in TMHH/TMHHX inst ructions are refreshed at the t ...

  • Omron CP1E-E@@D@-@ - page 110

    2 Instructions 2-74 CP1E CPU Unit Instructions Reference Manual(W483) TTIM/TTIMX Applicable Pr ogram Areas Operands N: Timer Number The timer numb er must be betwee n 0000 to 0255 (decimal). S: Set V alue TTIM (BCD): #000 0 to #9999 TTIMX (Binar y): &0 to &65535 (decimal) or #0000 to #FFFF (hex )  Operand Specifications Flags Instruction ...

  • Omron CP1E-E@@D@-@ - page 111

    2-75 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2 TTIM/TTIMX Function Hint • T ypical timers such as TIM/TIMX(5 50) are decrementing co unters and the PV sho ws the time remain- ing until the timer times out. The PV of TTIM( 087)/TTIMX(555) sh ows ho w much time has e lapsed, so the PV can be u ...

  • Omron CP1E-E@@D@-@ - page 112

    2 Instructions 2-76 CP1E CPU Unit Instructions Reference Manual(W483) • When a TTIM(087)/TTIMX(555) timer is fo rced set, its Completion Flag will be turned ON and its PV will be reset to 0. When a TTIM(087)/TTIMX(555) timer is f orced reset, its Completion Flag will be turned OFF and its PV will be reset to 0. The f orced set and f orced reset o ...

  • Omron CP1E-E@@D@-@ - page 113

    2-77 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2 TIML/TIMLX TIML/TIMLX Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function LONG TIMER TIML --- 542 TIML(542)/TIMLX(553) operates a decrementing timer with units of 0.1s. TIMLX ...

  • Omron CP1E-E@@D@-@ - page 114

    2 Instructions 2-78 CP1E CPU Unit Instructions Reference Manual(W483) Function • TIML(542)/TIMLX(553 ) can time up to 115 da ys f or TIML(542 ) and 4,971 da ys f or TIMLX(553). • The timer accuracy is 0 to 0.01 s. Precautions • Unlike most timers, TIML(542)/ TIMLX(55 3) does not use a timer numb er . (Timer area PV refreshing is not perf or m ...

  • Omron CP1E-E@@D@-@ - page 115

    2-79 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2 TIML/TIMLX Sample pr ogram When timer input CIO 0.00 is ON in the f ollowing e xample, the timer PV (in D201 and D200) will be set to the SV (in D101 and D100) and the PV will begin counting do wn. The timer Completion Flag (CIO 200.00) will be tu ...

  • Omron CP1E-E@@D@-@ - page 116

    2 Instructions 2-80 CP1E CPU Unit Instructions Reference Manual(W483) CNT/CNTX Applicable Pr ogram Areas Operands N: Counter Number The counter number must be bet w een 0000 and 0255 (decimal). S: Set V alue CNT (BCD): #0000 to #9999 CNTX (Binar y): &0 to &65535 (decimal) or #0000 to #FFFF (hex)  Operand Specifications Flags Instruction ...

  • Omron CP1E-E@@D@-@ - page 117

    2-81 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2 CNT/CNTX Function • The setting range 0 to 9,999 f or CNT and 0 to 65,535 f or CNTX(546). Hint Precautions • Counter numbers are shared b y the CNT , CNTX(546), CNTR(0 12) and CNTRX(548) instructions. If two counters share the same counter num ...

  • Omron CP1E-E@@D@-@ - page 118

    2 Instructions 2-82 CP1E CPU Unit Instructions Reference Manual(W483) • When a CNT/CNTX(546) counter is f o rced set, its Completion Flag will be turned ON and its PV will be reset to 0000. When a CNT/CNTX(546) counter is f orced reset, its Completion Flag will be turned OFF and its PV will be set to the SV . • If online editing is used to add ...

  • Omron CP1E-E@@D@-@ - page 119

    2-83 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2 CNTR/CNTRX CNTR/CNTRX Applicable Pr ogram Areas Operands N: Counter Number The counter numb er must be betw een 0000 and 0255(decima l). S: Set V alue CNTR (BCD):#0000 to #9999 CNTRX (Binar y): &0 to &65535 (decimal) or #0000 to #FFFF (hex ...

  • Omron CP1E-E@@D@-@ - page 120

    2 Instructions 2-84 CP1E CPU Unit Instructions Reference Manual(W483) Function Precautions • Counter numbers ar e shared b y the CNT , CNTX(5 46), CNTR(012) and CNTRX(548) instructions. If two counters share the same counter number but are not used simultaneously , a duplication error will be generated when the progr am is check ed but the counte ...

  • Omron CP1E-E@@D@-@ - page 121

    2-85 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2 CNTR/CNTRX The add and subtract count inp uts increase/decrea se the count once when the signal rises (OFF to ON). When bo th inputs turn ON at the same time , neither increases/decreases the count. When the reset input turns ON, the PV changes to ...

  • Omron CP1E-E@@D@-@ - page 122

    2 Instructions 2-86 CP1E CPU Unit Instructions Reference Manual(W483) CNR/CNRX Applicable Pr ogram Areas Operands N1: First Number in Range N1 must be a timer number betwe en T000 and T255 or a coun ter number be tween C000 and C255 . N2: Last Number in Range N2 must be a timer number betwe en T000 and T255 or a coun ter number be tween C000 and C2 ...

  • Omron CP1E-E@@D@-@ - page 123

    2-87 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Timer and Counter Instructions 2 CNR/CNRX Precautions • The timer/cou nter that is reset is as follo ws. • The CNR(545)/CNRX( 547) instructions do no t reset TIML(542) and TIMLX(553), beca use these tim- ers do not use timer numbers. • The CNR(545)/CNRX(547) instructions do ...

  • Omron CP1E-E@@D@-@ - page 124

    2 Instructions 2-88 CP1E CPU Unit Instructions Reference Manual(W483) Comparison Instructions =, <>, <, <=, >, >= Applicable Pr ogram Areas Operands  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function Input Comparison Instr uctions =, <>, <, <=, >, >= --- 300 to 3 28 Input co ...

  • Omron CP1E-E@@D@-@ - page 125

    2-89 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Comparison Instru ctions 2 =, <>, <, <=, >, >= Function i  Options The input comparison instr uctions can com pare signed or un signed data and they can compare one- word or doub le values . If no options are specified, the compar ison will be fo r one-word u ...

  • Omron CP1E-E@@D@-@ - page 126

    2 Instructions 2-90 CP1E CPU Unit Instructions Reference Manual(W483) Unsigned input comparison instr uctions (i.e., instructions without the S option) can handle unsigned binar y or BCD data. Sig ned input comparison instr u ctions (i.e., instructions with the S option) handle signed binary data. Hint • Unlike instructions such as CMP(020) and C ...

  • Omron CP1E-E@@D@-@ - page 127

    2-91 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Comparison Instru ctions 2 =DT , <>DT , <DT , <=DT , >DT , >=DT =DT, <>DT, <DT, <=DT, >DT, >=DT Applicable Pr ogram Areas Operands C: Control W or d Bits 00 to 05 of C specify whether or not the time data will be masked f or the compar ison. Bi ...

  • Omron CP1E-E@@D@-@ - page 128

    2 Instructions 2-92 CP1E CPU Unit Instructions Reference Manual(W483) i  Operand Specifications Flags Area W ord addresses Indirect DM addresses Constants CF Pulse bits TR bits CIO WR HR AR T C DM @DM *DM C OK OK OK OK OK OK OK --- --- OK --- --- --- S1, S2 OK OK --- Name Label Operation Error Flag P_ER • ON if all 6 of the mask bits (C bits 0 ...

  • Omron CP1E-E@@D@-@ - page 129

    2-93 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Comparison Instru ctions 2 =DT , <>DT , <DT , <=DT , >DT , >=DT Function The time comparison instr uction compares the unmasked v a lues (corresponding bit of C set to 0) of the present time data in S 1 to S 1 +2 with the compariso n time data in S 2 to S 2 +2 a ...

  • Omron CP1E-E@@D@-@ - page 130

    2 Instructions 2-94 CP1E CPU Unit Instructions Reference Manual(W483) Precautions • Time comparison instru ctions cannot be used as right-hand instr uctions, i.e ., another instruction must be used betw een them and the right b us bar . • E-type CP1E CPU Unit (CP1E-E  -  ) does not hav e the clock function. The clock data inside ...

  • Omron CP1E-E@@D@-@ - page 131

    2-95 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Comparison Instru ctions 2 CMP/CMPL CMP/CMPL Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function COMP ARE CMP !CMP 020 Compares two unsigned binar y values (constants and/or the contents of specified words) ...

  • Omron CP1E-E@@D@-@ - page 132

    2 Instructions 2-96 CP1E CPU Unit Instructions Reference Manual(W483)  The follo wing table sho ws the status of the Arithmetic Flags after execution of CMP(020). * A status of “---” indicates th at the Flag may be ON or OFF .  The follo wi ng table shows the status of the Arithmetic Flags after ex ecution of CMPL(060) . * A status of “ ...

  • Omron CP1E-E@@D@-@ - page 133

    2-97 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Comparison Instru ctions 2 CMP/CMPL Precautions • Using CMP(020)Results in the Program When CMP(020)/CMPL( 060) is ex ecuted, the result is reflected in the Arithmetic Flags. Control the desired output or right-hand instr uction with a bran ch from the same input con dition tha ...

  • Omron CP1E-E@@D@-@ - page 134

    2 Instructions 2-98 CP1E CPU Unit Instructions Reference Manual(W483) CPS/CPSL Applicable Pr ogram Areas Operands  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function SIGNED BINAR Y COMP ARE CPS !CPS 114 Compares two signed binary values (constants and/or the contents of specified words) and out- puts the result ...

  • Omron CP1E-E@@D@-@ - page 135

    2-99 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Comparison Instru ctions 2 CPS/CPSL  The follo wing table sho ws the status of the Arit hmetic Flags after ex ecution of CPS(114). * A status of “---” indicates that the Flag ma y be ON or OFF .  The follo wing table sho ws the status of th e Arithmetic Flags after exec ...

  • Omron CP1E-E@@D@-@ - page 136

    2 Instructions 2-100 CP1E CPU Unit Instructions Reference Manual(W483) Precautions • When CPS(114)/CPSL(1 15) is e x ecuted, t he result is reflected in the Ar ithmetic Flags . Control the desired output or right- hand instr uction with a bran ch from the same input condition that controls CPS(114)/CPSL(115), as shown in the f ollowing diagram. ? ...

  • Omron CP1E-E@@D@-@ - page 137

    2-101 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Comparison Instru ctions 2 TCMP TCMP Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function T ABLE COMP ARE TCMP @TCMP 085 Compares the source data to the contents of 16 consecutive words and turns ON the corr ...

  • Omron CP1E-E@@D@-@ - page 138

    2 Instructions 2-102 CP1E CPU Unit Instructions Reference Manual(W483) Function i TCMP(085) compare s the source data (S) to each of the 16 words T through T+15 and turns ON the corre- sponding bit in word R when the data are equal. Bit n of R is tur ned ON if the content of T+n is equal to S and it is tur ned OFF if they are not equal. S is compar ...

  • Omron CP1E-E@@D@-@ - page 139

    2-103 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Comparison Instru ctions 2 BCMP BCMP Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function BLOCK COMP ARE BCMP @BCMP 068 Compares the source data to 16 ranges (defined by 16 lo wer limits and 16 upper limits) ...

  • Omron CP1E-E@@D@-@ - page 140

    2 Instructions 2-104 CP1E CPU Unit Instructions Reference Manual(W483) Function BCMP(068) compares the source data (S) to the 16 ranges defi ned b y pairs of low er and upper limit values in B through B+31. The first word in each pair (B+2n) pr ovides the lower limit and the second word (B+2n+1) provides the upp er limit of r ange n (n = 0 to 15). ...

  • Omron CP1E-E@@D@-@ - page 141

    2-105 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Comparison Instru ctions 2 ZCP/ZCPL ZCP/ZCPL Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function AREA RANGE COMP ARE ZCP --- 088 Compares a 16-bit unsigned binar y value (CD) with the range defined by lower ...

  • Omron CP1E-E@@D@-@ - page 142

    2 Instructions 2-106 CP1E CPU Unit Instructions Reference Manual(W483) Function  ZCP ZCP(088) compa res the 16-bit signed bin ar y data in CD with the range de fined by LL and UL and out- puts the result to the Greater Than, Equals, and Less Than Flags in the A uxiliar y Area. (The Less Than or Equal, Greater Than or Equal, and Not Equal Flags a ...

  • Omron CP1E-E@@D@-@ - page 143

    2-107 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Comparison Instru ctions 2 ZCP/ZCPL • Do not progra m another instruction between ZCP(088)/ZCPL(11 6) and the instruction controlled b y the Arithmetic Flag because the othe r instr uction might change the status of the Arithmetic Flag. Sample pr ogram • When CIO 0.00 is ON ...

  • Omron CP1E-E@@D@-@ - page 144

    2 Instructions 2-108 CP1E CPU Unit Instructions Reference Manual(W483) Data Mo vement Instructions MO V/MO VL/MVN Applicable Pr ogram Areas Operands  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function MO VE MO V @MOV , !MOV , !@MO V 021 T ransf ers a word of data to the specified word. DOUBLE MOVE MO VL @MO VL ...

  • Omron CP1E-E@@D@-@ - page 145

    2-109 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Movement Instructions 2 MO V/MOVL/MVN Function Precautions MO V(021) has an immediate refr eshing v ariation (!MO V( 021)). A CPU Unit Built -in input bits can be specified f or S and external output bits can be specified for D . Input bits used for S will refreshed just be ...

  • Omron CP1E-E@@D@-@ - page 146

    2 Instructions 2-110 CP1E CPU Unit Instructions Reference Manual(W483) When CIO 0.00 is ON in the follo wing example , th e content of D101 and D1 00 are copied to D201 a nd D200. When CIO 0.00 is ON in the f ollowing e xample, the status of the bits in CIO 100 is inv er ted and the result is copied to D100. 0.01 MOV +1234 D11 0.02 MOV -1234 D12 0. ...

  • Omron CP1E-E@@D@-@ - page 147

    2-111 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Movement Instructions 2 MO VB MO VB Applicable Pr ogram Areas Operands C: Control W or d  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function MO VE BIT M O VB @MO VB 082 T ransfers the specified bit. Symbol MO VB Area Step prog ram areas ...

  • Omron CP1E-E@@D@-@ - page 148

    2 Instructions 2-112 CP1E CPU Unit Instructions Reference Manual(W483) Function Hint The same word can be specified for both S and D to copy a bit within a w ord. Precautions The other bits in the destinat ion word are lef t unchanged. Sample pr ogram When CIO 0.00 is ON in the f ollowing e xample, the 5 th bit of the source w ord (W0) is copied to ...

  • Omron CP1E-E@@D@-@ - page 149

    2-113 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Movement Instructions 2 MO VD MO VD Applicable Pr ogram Areas Operands S: Source W or d D: Destination W ord C: Control W or d  Operand Specifications Instruction Mnemonic V ariations Function code Function MO VE DIGIT MO VD @MO VD 083 T ransfers the specified digit or d ...

  • Omron CP1E-E@@D@-@ - page 150

    2 Instructions 2-114 CP1E CPU Unit Instructions Reference Manual(W483) Flags Function Precautions If the number of digits being read or written exceeds the leftmost digit of S or D , MO VD(083) will wrap to the rightmost digit of the same w ord. Sample pr ogram When CIO 0.00 is ON in the f ollowing examp le, f our digits of data are copied fr om W0 ...

  • Omron CP1E-E@@D@-@ - page 151

    2-115 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Movement Instructions 2 XFRB XFRB Applicable Pr ogram Areas Operands C: Control W or d D: First destination W ord Note The source words and the destination words must be in the same data area respectively . S: First Sour ce W ord  Operand Specifications Flag s Instructio ...

  • Omron CP1E-E@@D@-@ - page 152

    2 Instructions 2-116 CP1E CPU Unit Instructions Reference Manual(W483) Function Hint • Up to 255 bits of data can be tr ansf erred per e x ecution of XFRB(062). • It is possible f or the source words an d destination words to o verlap . By transferring data ov er lapping se ve ral words , the data can be pac ked more efficie ntly in the data ar ...

  • Omron CP1E-E@@D@-@ - page 153

    2-117 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Movement Instructions 2 XFER XFER Applicable Pr ogram Areas Operands N: Number of W ords Specifies the number of wo rds to be tr ansf erred. The possible ra nge f or N is 0000 to FFFF (0 to 65,535 decimal).  Operand Specifications Flag s Instruction Mnemonic V ariations ...

  • Omron CP1E-E@@D@-@ - page 154

    2 Instructions 2-118 CP1E CPU Unit Instructions Reference Manual(W483) Function Hint Precautions • Be sure that the sour ce words (S to S+N-1) and destination words (D to D+N-1) do not exceed the end of the data area. • Some time will be required to complete XFER(070) when a large number of words is being trans- f erred. Even if an interrupt oc ...

  • Omron CP1E-E@@D@-@ - page 155

    2-119 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Movement Instructions 2 BSET BSET Applicable Pr ogram Areas Operands St: Star ting W ord Specifies the first word in the destination range . E: End W ord Specifies the last word in the destination range . Note St and E must be in the same data area.  Operand Specificatio ...

  • Omron CP1E-E@@D@-@ - page 156

    2 Instructions 2-120 CP1E CPU Unit Instructions Reference Manual(W483) Function Precautions • Some time will be required to complete BSET(071) when a large number of words is being set. Ev en if an interrupt occurs, ex ecution of this instruction will not be interr upted and ex ecution of the interr upt task will be star ted after ex ecution of B ...

  • Omron CP1E-E@@D@-@ - page 157

    2-121 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Movement Instructions 2 XCHG XCHG Applicable Pr ogram Areas Operands  Operand Specifications Flag s Function Instruction Mnemonic V ariations Function code Function D A T A EXCHANGE XCHG @XCHG 073 Exchanges the contents of the two specified wor ds. Symbol XCHG Area Step ...

  • Omron CP1E-E@@D@-@ - page 158

    2 Instructions 2-122 CP1E CPU Unit Instructions Reference Manual(W483) Hint Sample pr ogram T o exchange 3 or more words , use XFER(070) to tran sfer the w ords to a third s et of words (a b uff er) as shown in this diag ram. When CIO 0.00 is ON in this example, the con- tent of D100 is exchan ged with the content of D200. E1 E2 Buffer 1 st XFER(07 ...

  • Omron CP1E-E@@D@-@ - page 159

    2-123 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Movement Instructions 2 DIST DIST Applicable Pr ogram Areas Operands Bs: Destination Base Address Of: Offset The offset can be an y value fr om 0000 to FFFF (0 to 65,535 decimal) . Note Bs and Bs+Of must be in the same data a rea.  Operand Specifications Flag s Instructi ...

  • Omron CP1E-E@@D@-@ - page 160

    2 Instructions 2-124 CP1E CPU Unit Instructions Reference Manual(W483) Function Hint The same DIST(080) instruction can be used to distribute the source w ord to v ar ious words in the data area by cha nging the v alue of Of . Precautions Be sure that the offset does not e xceed the end of the data area, i.e ., Bs and Bs+Of are in the same data are ...

  • Omron CP1E-E@@D@-@ - page 161

    2-125 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Movement Instructions 2 COLL COLL Applicable Pr ogram Areas Operands Bs: Sour ce Base Address Of: Offset The offset can be any v alu e from 0000 to FFFF (0 to 65,535 decimal). Note Bs and Bs+Of must be in the same data a rea.  Operand Specifications Flag s Instruction Mn ...

  • Omron CP1E-E@@D@-@ - page 162

    2 Instructions 2-126 CP1E CPU Unit Instructions Reference Manual(W483) Function Hint The same COLL(081) instru ction can be used to collect data from v arious source words in the data area by cha nging the v alue of Of . Precautions Be sure that the offset does not e xceed the end of the data area, i.e ., Bs and Bs+Of are in the same data area. Sam ...

  • Omron CP1E-E@@D@-@ - page 163

    2-127 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Shift Instructions 2 SFT Data Shift Instructions SFT Applicable Pr ogram Areas Operands  Operand Specifications Flag s Function • When the e x ecution condition on the shift input changes from OFF to ON, all the data from St to E is shifted to the left by one bit (from ...

  • Omron CP1E-E@@D@-@ - page 164

    2 Instructions 2-128 CP1E CPU Unit Instructions Reference Manual(W483) Precautions • Do not use more than one SFT(010) instructions with ov erlapping shift words. The results will not be dependab le. • St and E must be in the same data area. • The bit data shifted out of th e shift register is discarded. • When the reset input tur ns ON, al ...

  • Omron CP1E-E@@D@-@ - page 165

    2-129 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Shift Instructions 2 SFTR SFTR Applicable Pr ogram Areas Operands C: Control W or d Note St and E must be in the same data area.  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function REVERSIBLE SHIFT REGIS- TER SFTR @SFTR 084 Creates a sh ...

  • Omron CP1E-E@@D@-@ - page 166

    2 Instructions 2-130 CP1E CPU Unit Instructions Reference Manual(W483) Function Note • The above shift operations are applicable when the reset bit (bit 15 o f C) is set to OFF . • When reset (bit 15 of C) tur ns ON all bits in the shift register, from St to E will be reset (i.e., set to 0). Sample pr ogram • Shifting Data If shift input W0.1 ...

  • Omron CP1E-E@@D@-@ - page 167

    2-131 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Shift Instructions 2 WSFT WSFT Applicable Pr ogram Areas Operands  Operand Specifications Flag s Function Precautions • St and E must be in the same data area. • When large amounts of data are shifted, the inst ruction ex ecution time is quit e long. Be sure that the ...

  • Omron CP1E-E@@D@-@ - page 168

    2 Instructions 2-132 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram When CIO 0.00 is ON, data from CIO 100 through CIO 102 will be shifted one wo rd toward E. The con- tents of W0 will be stored in CIO 100 and the contents of CIO 102 will be lost. i WSFT W0 100 102 0.00 S St E E: CIO 100 St: CIO 101 St: CIO 102 St: W0 Lost ...

  • Omron CP1E-E@@D@-@ - page 169

    2-133 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Shift Instructions 2 ASL ASL Applicable Pr ogram Areas Operands  Operand Specifications Flag s Function Sample pr ogram Instruction Mnemonic V ariations Function code Function ARITHMETIC SHIFT LEFT ASL @ASL 025 Shifts the contents of Wd one bit to the left. Symbol ASL Ar ...

  • Omron CP1E-E@@D@-@ - page 170

    2 Instructions 2-134 CP1E CPU Unit Instructions Reference Manual(W483) ASR Applicable Pr ogram Areas Operands  Operand Specifications Flags Function Sample pr ogram Instruction Mnemonic V ariations Function code Function ARITHMETIC SHIFT RIGHT ASR @ASL 026 Shifts the contents of Wd one bit to the right. Symbol ASR Area Step program are as Subrou ...

  • Omron CP1E-E@@D@-@ - page 171

    2-135 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Shift Instructions 2 ROL RO L Applicable Pr ogram Areas Operands  Operand Specifications Flag s Function Hint It is possible to set the Carry Flag contents to 1 or 0 immediately befo re e xecuting thi s instr uction, by using the Set Carr y (STC( 040)) or Clear Carry (C ...

  • Omron CP1E-E@@D@-@ - page 172

    2 Instructions 2-136 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram When CIO 0.00 is ON, word CIO 100 and the Carr y Flag (CY) will shift one bit to the left. The contents of CIO 100.15 will be shifted to the Carry Flag (CY) and the Carr y Flag con- tents will be shifted to CIO 100.00. ROL 100 0.00 Wd 0 15 0 CY 1 0 0 1 0 0 0 1 0 ...

  • Omron CP1E-E@@D@-@ - page 173

    2-137 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Shift Instructions 2 ROR RO R Applicable Pr ogram Areas Operands  Operand Specifications Flag s Function Hint It is possible to set the Carry Flag contents to 1 or 0 immediately befo re e xecuting thi s instr uction, by using the Set Carr y (STC( 040)) or Clear Carry (C ...

  • Omron CP1E-E@@D@-@ - page 174

    2 Instructions 2-138 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram When CIO 0.00 is ON, word CIO 100 and the Carr y Flag (CY) will shift one bit to the r ight. The contents of CIO 100.00 will be shifted to the Carr y Flag (CY) and the Carr y Flag contents will be shifted to CIO 100.15. ROR 100 0.00 Wd 0 15 0 1 0 0 1 0 0 1 0 0 1 ...

  • Omron CP1E-E@@D@-@ - page 175

    2-139 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Shift Instructions 2 SLD/SRD SLD/SRD Applicable Pr ogram Areas Operands  Operand Specifications Flag s Function  SLD SLD(074) shifts data be tween St and E by one digit (4 bi ts) to the lef t. “0” is placed in the rightmost digit (bits 3 to 0 of St), and the conte ...

  • Omron CP1E-E@@D@-@ - page 176

    2 Instructions 2-140 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram  SLD When CIO 0.00 is ON, word s CIO 100 through CIO 102 will shift by one digit (4 bits) to the left. A z ero will be placed in bits 0 to 3 of word CIO 100 and the contents of bits 12 to 15 of CIO 102 will be lost.  SRD When CIO 0.00 is ON, words CIO 100 t ...

  • Omron CP1E-E@@D@-@ - page 177

    2-141 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Shift Instructions 2 NASL/NSLL NASL/NSLL Applicable Pr ogram Areas Operands C: C o n t rol wo rd  Operand Specifications Instruction Mnemonic V ariations Funct ion code Function SHIFT N-BITS LEFT N ASL @NASL 580 Shifts the specified 16 bits of word data to the left by th ...

  • Omron CP1E-E@@D@-@ - page 178

    2 Instructions 2-142 CP1E CPU Unit Instructions Reference Manual(W483) Flags Function  NASL NASL(580) shifts D (the shift word) by the specified number of binary bits (specifi ed in C) to the left (from the rightmost bit to the leftmost bit). Either zeros or the v alue of the r ightmost bit will be placed into the specified number of bits of the ...

  • Omron CP1E-E@@D@-@ - page 179

    2-143 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Shift Instructions 2 NASL/NSLL Sample pr ogram When CIO 0.00 is ON, The contents of CIO 100 is shifted 10 bits to the left (fro m the rightmost bit to the leftmost bit). The number of bits to shift is specified in bits 0 to 7 of word W0 (contr ol data). The con- tents of bi ...

  • Omron CP1E-E@@D@-@ - page 180

    2 Instructions 2-144 CP1E CPU Unit Instructions Reference Manual(W483) NASR/NSRL Applicable Pr ogram Areas Operands C : C o nt ro l wo rd  Operand Specifications Instruction Mnemonic V ariations Function code Function SHIFT N-BITS RIGHT NASR @NASR 581 Shifts the specified 16 bits of word data to the r ight by the specified number of bits. DOUBLE ...

  • Omron CP1E-E@@D@-@ - page 181

    2-145 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Shift Instructions 2 NASR/NSRL Flag s Function  NASR NASR(581) shifts D (the shift word) by the specified num ber of binary bits (spe cified in C) to the r ight (from the rightmost bit to the leftmost bit). Either zeros or the value of the rightmost bit will be placed in ...

  • Omron CP1E-E@@D@-@ - page 182

    2 Instructions 2-146 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram • When CIO 0.00 is ON, CIO 100 will be shifted 10 bits to the right (from the leftmost bit to the right- most bit). The number of bits to shift is specified in bits 0 to 7 of W0. The contents of bit 15 of CIO 100 is copied into the bits from which data was shif ...

  • Omron CP1E-E@@D@-@ - page 183

    2-147 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Increment/Decrement Instructions 2 + +/+ +L Increment/Decrement Instructions + +/+ +L Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function INCREMENT BINAR Y + + @+ + 590 Increments the 4-digit hexadecimal co ...

  • Omron CP1E-E@@D@-@ - page 184

    2 Instructions 2-148 CP1E CPU Unit Instructions Reference Manual(W483) Function Sample pr ogram  Operation of + +(590)/+ +L(591) In the follo wing example, the content of D100 will be incremented b y 1 ev er y cycle as long as CIO 0.00 is ON. In the follo wing example, the content of D100 will be incremented b y 1 ev er y cycle as long as CIO 0. ...

  • Omron CP1E-E@@D@-@ - page 185

    2-149 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Increment/Decrement Instructions 2 + +/+ +L  Operation of @+ +(590)/@+ +L(591) The up-diff erentiated variation is used in the f ollowing example , so the content of D100 will be incre- mented b y 1 only when CIO 0.00 has gone from OFF to ON. The up-diff erentiated va riation ...

  • Omron CP1E-E@@D@-@ - page 186

    2 Instructions 2-150 CP1E CPU Unit Instructions Reference Manual(W483) -- / -- L Applicable Pr ogram Areas Operands  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function DECREMENT BINAR Y - - @- - 592 Decrements the 4-digit h e xadecimal content of the specified word by 1. DOUBLE DE CREMENT BINAR Y -- L @ -- L 5 ...

  • Omron CP1E-E@@D@-@ - page 187

    2-151 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Increment/Decrement Instructions 2 - -/- -L Function Sample pr ogram  Operation of - -(592)/- -L(593) The up-diff erentiated variation is used in the f ollowing e xample, so the content of D100 will be decre- mented b y 1 only when CIO 0.00 has gone from OFF to ON. In the f o ...

  • Omron CP1E-E@@D@-@ - page 188

    2 Instructions 2-152 CP1E CPU Unit Instructions Reference Manual(W483)  Operation of @- -(592)/@- -L(593) In the follo w ing e xample, the content of D100 will be dec remented by 1 e very cycle as long as CIO 0.00 is ON. The up-diff erentiated v ariation is used in the follo wing e xample, so the content of D101 and D100 will be decremented b y ...

  • Omron CP1E-E@@D@-@ - page 189

    2-153 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Increment/Decrement Instructions 2 + +B/+ +BL + +B/+ +BL Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function INCREMENT BCD + +B @+ +B 594 Increments the 4-digit BCD content of the speci- fied word by 1. DOU ...

  • Omron CP1E-E@@D@-@ - page 190

    2 Instructions 2-154 CP1E CPU Unit Instructions Reference Manual(W483) Function Sample pr ogram  Operation of + +B(594)/+ +BL(595) In the f ollowing e xample, the BCD content of D100 will be incremented b y 1 e v er y cycle as long as CIO 0.00 is ON. In the f ollowing example , the 8-digit BCD content of D101 and D100 will be incremented by 1 e ...

  • Omron CP1E-E@@D@-@ - page 191

    2-155 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Increment/Decrement Instructions 2 + +B/+ +BL  Operation of @+ +B(594)/@+ +BL(595) The up-diff erentiated variation is used in the f ollowing example , so the content of D100 will be incre- mented b y 1 only when CIO 0.00 has gone from OFF to ON. The up-diff erentiated variat ...

  • Omron CP1E-E@@D@-@ - page 192

    2 Instructions 2-156 CP1E CPU Unit Instructions Reference Manual(W483) - -B/- -BL Applicable Pr ogram Areas Operands  Operand Specifications Flags Function Instruction Mnemonic V ariations Functio n code Function DECREMENT BCD - -B @- -B 596 Decrements the 4-digit BC D content of the speci- fied word by 1. DOUBLE DECREMENT BCD - -BL @- -BL 597 D ...

  • Omron CP1E-E@@D@-@ - page 193

    2-157 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Increment/Decrement Instructions 2 - -B/- -BL Sample pr ogram  Operation of - -B(596)/- -BL(597) In the f ollowing e xample, the BCD content of D100 will be decremented by 1 e very cyc le as long as CIO 0.00 is ON. In the f ollowing e xample, the 8-di git BCD content of D101 ...

  • Omron CP1E-E@@D@-@ - page 194

    2 Instructions 2-158 CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions +/+L Applicable Pr ogram Areas Operands  Operand Specifications Instruction Mnemonic V ariations Functio n code Function SIGNED BINAR Y ADD WITHOUT CARR Y + @+ 400 Adds 4-digit (single-word) hexadecimal data and/or constants. DOUBLE SIGNED BINAR Y ADD ...

  • Omron CP1E-E@@D@-@ - page 195

    2-159 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions 2 +/+L Flag s Function  + +(400) adds the binar y values in A u and Ad and outputs the result to R.  +L +L(401) adds the binar y values in A u and Au+1 and Ad and Ad+1 and outputs the result to R. Sample pr ogram Name Label Operation + +L Error Fla ...

  • Omron CP1E-E@@D@-@ - page 196

    2 Instructions 2-160 CP1E CPU Unit Instructions Reference Manual(W483) +C/+CL Applicable Pr ogram Areas Operands  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function SIGNED BINAR Y ADD WITH CARR Y +C @+C 402 Adds 4-digit (single-word) he xadecimal data and/or constants with the Carr y Flag (CY). DOUBLE SIGNED BI ...

  • Omron CP1E-E@@D@-@ - page 197

    2-161 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions 2 +C/+CL Function  +C +C(402) adds the binary values in A u, Ad, and CY and outputs the result to R.  +CL +CL(403) adds the binar y values in A u and Au+1, Ad and Ad+1, and CY and outputs the result to R. Hint • T o clear the Carr y Flag (CY) , e ...

  • Omron CP1E-E@@D@-@ - page 198

    2 Instructions 2-162 CP1E CPU Unit Instructions Reference Manual(W483) +B/+BL Applicable Pr ogram Areas Operands  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function BCD ADD WITHOUT CARR Y +B @+B 404 Adds 4-digit (single-word) BCD data and/or con- stants. DOUBLE BCD ADD WITHOUT CARR Y +BL @+BL 405 Adds 8-digit ( ...

  • Omron CP1E-E@@D@-@ - page 199

    2-163 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions 2 +B/+BL Function  +B +B(404) adds the BCD values in A u and Ad and outputs the result to R.  +BL +BL(405) adds the BCD v alues in A u and Au+1 and Ad and Ad +1 and outputs th e result to R, R+1. Sample pr ogram + R CY (BCD) (BCD) (BCD) Au Ad CY wi ...

  • Omron CP1E-E@@D@-@ - page 200

    2 Instructions 2-164 CP1E CPU Unit Instructions Reference Manual(W483) +BC/+BCL Applicable Pr ogram Areas Operands  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function BCD ADD WITH CARR Y +BC @+BC 406 Adds 4-digit (single-word) BCD data and/or con- stants with the Carr y Fla g (CY). DOUBLE BCD ADD WITH CARR Y +B ...

  • Omron CP1E-E@@D@-@ - page 201

    2-165 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions 2 +BC/+BCL Function  +BC +BC(406) adds BCD v alue s in Au, Ad, and CY and outputs the result to R.  +BCL +BCL(407) adds the BCD value s in A u and Au+1, Ad and Ad+1, and CY and out puts the result to R, R+1. Hint • T o clear the Carr y Flay (CY), ...

  • Omron CP1E-E@@D@-@ - page 202

    2 Instructions 2-166 CP1E CPU Unit Instructions Reference Manual(W483) –/–L Applicable Pr ogram Areas Operands  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function SIGNED BINAR Y SUBTRA CT WITHOUT CARR Y – @– 410 Subtracts 4-digit (single-word) hexadecimal data and/or constants. DOUBLE SIGNED BINAR Y SUB ...

  • Omron CP1E-E@@D@-@ - page 203

    2-167 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions 2 –/–L Function  – –(400) subtracts the binar y v alues in Su from Mi and outputs the result to R. Wh en the result is nega- tive , it is output to R as a 2’ s complement.  –L –L(411) subtracts the bi nary values in Su and Su+1 from M ...

  • Omron CP1E-E@@D@-@ - page 204

    2 Instructions 2-168 CP1E CPU Unit Instructions Reference Manual(W483) Hint • 2’ s Complement A 2’ s complement is the value obtaine d b y subtracting each binary digit from 1 and adding one to the result. F or e xample, the 2’ s complement for 1101 is calculated as f ollows: 1111 (F he xadecimal) – 1101 (D he xadecimal) + 1 (1 he xadecim ...

  • Omron CP1E-E@@D@-@ - page 205

    2-169 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions 2 –/–L Subtraction at (1) Subtraction at (2) Final Subtraction Result Sample pr ogram If the result of the subtract ion is a negativ e number (Mi<Su or Mi+1, Mi <Su+1, Su), the result is output as the 2’ s complement and the Carr y Flag (CY) ...

  • Omron CP1E-E@@D@-@ - page 206

    2 Instructions 2-170 CP1E CPU Unit Instructions Reference Manual(W483) –C/–CL Applicable Pr ogram Areas Operands  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function SIGNED BINAR Y SUBTRA CT WITH CARR Y –C @–C 412 Subtracts 4-digit (single-word) he xadecimal data and/or constants with the Carr y Flag (CY ...

  • Omron CP1E-E@@D@-@ - page 207

    2-171 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions 2 –C/–CL Function  –C –C(412) subtracts the bi nary values in Su and CY from Mi, and outputs the resu lt to R. When the result is negative , it is output to R as a 2’ s complement.  –CL –CL(413) subtracts the binary values in Su and S ...

  • Omron CP1E-E@@D@-@ - page 208

    2 Instructions 2-172 CP1E CPU Unit Instructions Reference Manual(W483) –B/–BL Applicable Pr ogram Areas Operands  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function BCD SUBTRACT WITHOUT CARR Y –B @–B 414 Subtracts 4-digit (single-word) BCD data and/or constants. DOUBLE BCD SUBTRACT WITHOUT CARR Y –BL ...

  • Omron CP1E-E@@D@-@ - page 209

    2-173 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions 2 –B/–BL Function  –B –B(414) subtracts the BCD v alues in Su from Mi and outputs th e result to R. If the result of the subtrac- tion is negative , the result is ou tput as a 10’ s complement.  –BL –BL(415) subtracts the BCD v alues ...

  • Omron CP1E-E@@D@-@ - page 210

    2 Instructions 2-174 CP1E CPU Unit Instructions Reference Manual(W483) Subtraction at (1) Subtraction at (2) Final Subtraction Result Sample pr ogram If the result of the subtraction is a negative n umber (M i<Su or Mi+1, Mi <Su+1, Su ), the result is output as a 10’ s complement. The Carry Flag (CY) will tur n ON. T o conv e r t the 10’ ...

  • Omron CP1E-E@@D@-@ - page 211

    2-175 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions 2 –BC/–BCL –BC/–BCL Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function BCD SUBTRACT WITH CARR Y –BC @–BC 416 Subtracts 4-digit (single-word) BCD data and/or constants w ...

  • Omron CP1E-E@@D@-@ - page 212

    2 Instructions 2-176 CP1E CPU Unit Instructions Reference Manual(W483) Function  –BC –BC(416) subtracts BCD v a lues in Su and CY from Mi and outputs th e result to R. If the result is nega- tive , it is output to R as a 10’ s complement.  –BCL –BCL(417)subtracts the BCD v alue s in Su, Su+1, and CY from Mi and Mi+1 and outputs the ...

  • Omron CP1E-E@@D@-@ - page 213

    2-177 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions 2 */*L */*L Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function SIGNED BINAR Y MUL TIPL Y * @* 420 Multiplies 4-digit signed he xadecimal data and/or constants. DOUBLE SIGNED BINAR ...

  • Omron CP1E-E@@D@-@ - page 214

    2 Instructions 2-178 CP1E CPU Unit Instructions Reference Manual(W483) Function  * *(420) multiplies the sign ed binary values in Md an d Mr and outputs th e result to R, R+1.  *L *L(421) multiplies the signed bi nary values in Md and Md+1 and Mr an d Mr+1 and output s the result to R, R+1, R+2, and R+3. Sample pr ogram × R + 1 Md Mr (Signed ...

  • Omron CP1E-E@@D@-@ - page 215

    2-179 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions 2 *B/*BL *B/*BL Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function BCD MUL TIPL Y *B @*B 424 Multiplies 4-digit (single-word) BCD data and/or constants. DOUBLE BCD MUL TIPL Y *BL @ ...

  • Omron CP1E-E@@D@-@ - page 216

    2 Instructions 2-180 CP1E CPU Unit Instructions Reference Manual(W483) Function  *B *B(424) multiplies the BCD content of Md and Mr and outputs the result to R, R+1.  *BL *BL(425) multiplies BCD v alues in Md and Md+1 and Mr and Mr+1 and outp uts the result to R, R+1, R+2, and R+3. Sample pr ogram × R + 1 R (BCD) (BCD) (BCD) Md Mr × R + 1 R ...

  • Omron CP1E-E@@D@-@ - page 217

    2-181 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions 2 /, /L /, /L Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function SIGNED BINAR Y DIVIDE / @/ 4 30 Divides 4-digit (single-word) signed he xadecimal data and/or constants. DOUBLE SIG ...

  • Omron CP1E-E@@D@-@ - page 218

    2 Instructions 2-182 CP1E CPU Unit Instructions Reference Manual(W483) Function  / /(430) divides the signed bi nary (16 bit) values in Dd b y those in Dr and outputs the re sult to R, R+1. The quotient is placed in R and the remainder in R+1. Note Division of he xadecimal #8000 by #FFFF is undefined.  /L /L(431) divides the signed binar y va ...

  • Omron CP1E-E@@D@-@ - page 219

    2-183 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Symbol Math Instructions 2 /B, /BL /B, /BL Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function BCD DIVIDE /B @/B 434 Divides 4-digit (single-word) BCD data and/or con- stants. DOUBLE BCD DIVIDE /BL @/BL 4 3 ...

  • Omron CP1E-E@@D@-@ - page 220

    2 Instructions 2-184 CP1E CPU Unit Instructions Reference Manual(W483) Function  /B /B(434) divides the BCD content of Dd by those of Dr and outputs the quotient to R and the remainder to R+1.  /BL /BL(435) divides BCD v alues in Dd and Dd+1 by those in Dr and Dr+1 and output s the quotient to R, R+1 and the remainder to R+2 , R+3. Sample pr ...

  • Omron CP1E-E@@D@-@ - page 221

    2-185 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions 2 BIN/BINL Con ver sion Instructions BIN/BINL Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function BCD T O BINAR Y BIN @BIN 023 Conv er ts BCD data to binar y data. DOUBLE BCD T O DO ...

  • Omron CP1E-E@@D@-@ - page 222

    2 Instructions 2-186 CP1E CPU Unit Instructions Reference Manual(W483) Function Sample pr ogram When CIO 0.00 is ON in the follo wing e xample, the 8-digit BCD v alue in CIO 0010 and CIO 0011 is con- verted to hexadecimal a nd stored in D200 and D201.  BIN BIN(023) conv er ts the BCD da ta in S to binar y data and writes the result to R. The f o ...

  • Omron CP1E-E@@D@-@ - page 223

    2-187 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions 2 BCD/BCDL BCD/BCDL Applicable Pr ogram Areas Operands S: Source W or d (BCD)/First Sour ce W ord (BCDL) • BCD S must be between 0000 and 270F he xadecimal (0000 and 9999 decimal). • BCDL The content of S+1 and S mu st be between 0000 00 00 and 05F5 ...

  • Omron CP1E-E@@D@-@ - page 224

    2 Instructions 2-188 CP1E CPU Unit Instructions Reference Manual(W483) Function Sample pr ogram When CIO 0.00 is ON in the f ollowing example , t he hexade cimal va lue in CIO 11 and CIO 10 is con- verted to a BCD value an d stored in D100 and D101.  BCD BCD(024) conv er ts the binar y data in S to BCD data and writes the result to R. The f ollo ...

  • Omron CP1E-E@@D@-@ - page 225

    2-189 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions 2 NEG NEG Applicable Pr ogram Areas Operands  Operand Specifications Flag s Function Hint • This operation (re versing the status of the bi ts and adding 1) is equiv alent to subtracting the content of S/S+1 and S fro m 0000/0000 0000. Instruction M ...

  • Omron CP1E-E@@D@-@ - page 226

    2 Instructions 2-190 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram When CIO 0.00 is ON in the f ollo wing e xample, NEG(160) ca lculates the 2’ s compleme nt of the content of D100 and writes the result to D200. 1 D100 2 34 ED CB = -) E D200 D CC 00 00 ED CC NEG D100 D200 0.00 12 34 Add 1 Actual calculation Equivalent subtract ...

  • Omron CP1E-E@@D@-@ - page 227

    2-191 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions 2 MLPX MLPX Applicable Pr ogram Areas Operands  4-to-16 bit decoder C: Control W or d Instruction Mnemonic V ariations Function code Function D A T A DECODER M LPX @MLPX 076 Reads the numerical value in the specified digit (or byte) in the source word ...

  • Omron CP1E-E@@D@-@ - page 228

    2 Instructions 2-192 CP1E CPU Unit Instructions Reference Manual(W483)  8-to-256 bit con version C : C o nt ro l W ord  Operand Specifications Flags Function MLPX(076) can perf or m 4-to-16 bit or 8-to-256 bit con versions . Set the leftm ost digit o f C to 0 to specify 4-to-16 bit conv ersion a nd set it to 1 to sp ecify 8-to-256 bit con ver ...

  • Omron CP1E-E@@D@-@ - page 229

    2-193 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions 2 MLPX Hint Precaution  4-to-16 bit con version When two or more digits are being conv er ted, MLPX(076) will read the digits in S from r ight to left and will wrap around to the rightmost digit after the leftmost digit, if necessar y .  8-to-256 b ...

  • Omron CP1E-E@@D@-@ - page 230

    2 Instructions 2-194 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram  4-to-16 bit Con version When CIO 0.00 is ON in the f o llowing e xample, MLPX(076) will con vert 3 digits in S beginning with digit 1 (the second digit), as indicated by C (#0021). The corresponding bits in D100, D101, and D102 will be turned ON.  8-to-256 ...

  • Omron CP1E-E@@D@-@ - page 231

    2-195 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions 2 MLPX  Example of multi-digit decoding • Example of 4-to -16 bit decoding • Example of 8-to-2 56 bit decoding R R+1 15 0 R R+1 R+2 R+3 15 0 S Digit 3 8 11 12 15 0 3 4 7 S 8 11 12 15 0 3 4 7 15 0 S 8 11 12 15 0 3 4 7 R R+1 R+2 R+3 C: #0010 C: #003 ...

  • Omron CP1E-E@@D@-@ - page 232

    2 Instructions 2-196 CP1E CPU Unit Instructions Reference Manual(W483) DMPX Applicable Pr ogram Areas Operands  16-to-4 bit con version C : C o nt ro l W ord Instruction Mnemonic V ariations Functio n code Function D A T A ENCODER DMPX @DMPX 077 FInds the location of the first or last ON bit within the source word with 16-to-4 conv ersion (or 25 ...

  • Omron CP1E-E@@D@-@ - page 233

    2-197 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions 2 DMPX  256-to-8 bit con version C: C o n t rol wo rd  Operand Specifications Flag s Function DMPX(077) can perf or m 16-to-4 bit or 256-to-8 bit conv er sions. Set the leftmost di git of C to 0 to specify 16-to-4 bit con v ersion and set it to 1 t ...

  • Omron CP1E-E@@D@-@ - page 234

    2 Instructions 2-198 CP1E CPU Unit Instructions Reference Manual(W483)  256-to-8 bit Con version When the f our th (leftmo st) digit of C is 1, DMPX( 077) finds the locat ions of the leftmost (highest bit address) or rightmost (lo west bit address) ON bits in one or tw o 16-word ranges of source w ords. The locations of these bits are wr itten t ...

  • Omron CP1E-E@@D@-@ - page 235

    2-199 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions 2 DMPX Sample pr ogram  16-to-4 bit Con version When CIO 0.00 is ON in the f ollowing e xample, DMPX(077) will find the leftmost ON bits in CIO 100, CIO 101, and CIO 102 and write those locations to 3 digits in R beginn ing with digit 1 (the second di ...

  • Omron CP1E-E@@D@-@ - page 236

    2 Instructions 2-200 CP1E CPU Unit Instructions Reference Manual(W483)  256-to-8 bit Con version If the conv ersion data contains 000 0 hex, b u t other data is to be encoded, separate the con version b y using more than one DMPX(07 7) instructions. DMPX(077) D0 D100 #0300 ⇓ DMPX(077) D0 D100 #0000 DMPX(077) D1 D100 #0001 DMPX(077) D2 D100 #00 ...

  • Omron CP1E-E@@D@-@ - page 237

    2-201 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions 2 ASC ASC Applicable Pr ogram Areas Operands DI: Digit Designator The digit designator specifies various parameters f or the conv ersion, as shown in the f ollowing dia- gram. Instruction Mnemonic V ariations Function code Function ASCII CONVER T ASC @AS ...

  • Omron CP1E-E@@D@-@ - page 238

    2 Instructions 2-202 CP1E CPU Unit Instructions Reference Manual(W483)  Operand Specifications Flags Function Hint • The parity bit is appen ded to the data to enable detection of errors when the da ta is tr ansmitted. By adding this bit, the n umber of bits that are 1 in the data can be indicate d as odd or e ven, and if the number of 1s in t ...

  • Omron CP1E-E@@D@-@ - page 239

    2-203 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions 2 ASC Sample pr ogram When CIO 0.00 is ON in the follo wing example, ASC(086) con ver ts three he xadecima l digits in D100 (beginning with digit 1) into their ASCII eq uiv alents and wr ites this data to D200 a nd D201 beginning with the leftmost byte i ...

  • Omron CP1E-E@@D@-@ - page 240

    2 Instructions 2-204 CP1E CPU Unit Instructions Reference Manual(W483)  Pa r i t y It is possible to specify the parity of the ASCII data fo r use in error control during data transmissions. The leftmost bit of each ASCII character will be automatically adjusted for e v en, odd, or no par ity . • When no parity (0) is designated, the leftmost ...

  • Omron CP1E-E@@D@-@ - page 241

    2-205 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions 2 HEX HEX Applicable Pr ogram Areas Operands DI: Digit Designator The digit designator specifies various parameters f or the conv ersion, as shown in the f ollowing dia- gram. Instruction Mnemonic V ariations Function code Function ASCII T O HEX HEX @HEX ...

  • Omron CP1E-E@@D@-@ - page 242

    2 Instructions 2-206 CP1E CPU Unit Instructions Reference Manual(W483)  Operand Specifications Flags Function Hint • The parity bit is appen ded to the data to enable detection of errors when the da ta is tr ansmitted. By adding this bit, the n umber of bits that are 1 in the data can be indicate d as odd or e ven, and if the number of 1s in t ...

  • Omron CP1E-E@@D@-@ - page 243

    2-207 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions 2 HEX Sample pr ogram When CIO 0.00 is ON in the f ollowing e xample, HEX(162) conv er ts the ASCII data in D100 and D101 according to the settings of the digit designator . (Di=#0121 specifies no pa rity , the star ting byte (when reading) = leftmost b ...

  • Omron CP1E-E@@D@-@ - page 244

    2 Instructions 2-208 CP1E CPU Unit Instructions Reference Manual(W483)  Output example * Parity bit - changes according to the par ity specificati on. When CIO 0.00 is ON in the f o llowing e xample, HEX(162) con v er ts the ASCII data in D10 beginning with the rightmost b yte and wr ites the he xa decimal equiv alents in D300 beginning with dig ...

  • Omron CP1E-E@@D@-@ - page 245

    2-209 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions 2 HEX  Example of con ver ting multiple b ytes of ASCII code to he x Di: #0112 Di: #0030 Di: #0131 Digit 3 Digit 2 Digit 1 Digit 0 Leftmost Rightmost Digit 3 Digit 2 Digit 1 Digit 0 Digit 3 Digit 2 Digit 1 Digit 0 Leftmost Rightmost Leftmost Rightmost ...

  • Omron CP1E-E@@D@-@ - page 246

    2 Instructions 2-210 CP1E CPU Unit Instructions Reference Manual(W483) Logic Instructions AND W/ANDL Applicable Pr ogram Areas Operands  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function LOGICAL AND AND W @ANDW 034 T ak es the logical AND of corresponding bits in sin- gle words of word data and/or constants. D ...

  • Omron CP1E-E@@D@-@ - page 247

    2-211 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Logic Instructions 2 AND W/ANDL Function Sample pr ogram When the e x ecution condit ion CIO 0.00 is ON, the logical AND is tak en of corresponding bits in CIO 11, CIO 10 and CIO 21, CIO 20 and the results will be output to corresponding bits in D201 and D200.  AND W AND W(03 ...

  • Omron CP1E-E@@D@-@ - page 248

    2 Instructions 2-212 CP1E CPU Unit Instructions Reference Manual(W483) OR W/OR WL Applicable Pr ogram Areas Operands  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function LOGICAL OR ORW @ORW 035 T ak es the logical OR of corresponding bits in sin- gle words of word data and/or constants. DOUBLE LOGICAL OR ORWL @O ...

  • Omron CP1E-E@@D@-@ - page 249

    2-213 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Logic Instructions 2 ORW/OR WL Function Sample pr ogram When the e x ecution co ndition CIO 0.00 is ON, the logical OR is ta ken of corresponding bits in CIO 21, CIO 20 and CIO 31, CIO 30 and the results will be output to corresponding bits in D501 and D500.  OR W OR W(035) t ...

  • Omron CP1E-E@@D@-@ - page 250

    2 Instructions 2-214 CP1E CPU Unit Instructions Reference Manual(W483) XOR W/XORL Applicable Pr ogram Areas Operands  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function EXCLUSIVE OR XORW @XORW 036 T akes the logical e xclusive OR of corresponding bits in single words of word data and/or constants. DOUBLE EXCLUS ...

  • Omron CP1E-E@@D@-@ - page 251

    2-215 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Logic Instructions 2 XORW/XORL Function Sample pr ogram When the e x ecution condition CIO 0.00 is ON, the logical exclusiv e OR is taken of corresponding bits in CIO 151, CIO 150 and D1001, D1000 and the results will be output to corresponding bits in D1201 and D1200.  XOR W ...

  • Omron CP1E-E@@D@-@ - page 252

    2 Instructions 2-216 CP1E CPU Unit Instructions Reference Manual(W483) COM/COML Applicable Pr ogram Areas Operands  Operand Specifications Flags Function  COM COM(029) re v erses the stat us of e very specified bit in Wd. Wd → Wd: 1 → 0 and 0 → 1 Note When using the COM instr uction, be aware that the sta tus of each bit will change eac ...

  • Omron CP1E-E@@D@-@ - page 253

    2-217 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Logic Instructions 2 COM/COML Sample pr ogram When CIO 0.00 is ON in the follo wing e xample, the status of each bit D100 will be rev ersed. When CIO 0.00 is ON in the follo wing example , the status of each bit in D100 and D101 will be rev ers ed. D100 1001000100010001 0 1 2 3 ...

  • Omron CP1E-E@@D@-@ - page 254

    2 Instructions 2-218 CP1E CPU Unit Instructions Reference Manual(W483) Special Math Instructions APR Applicable Pr ogram Areas Operands  Sine Function  Cosine Function Instruction Mnemonic V ariations Functio n code Function ARITHMETIC PROCESS APR @APR 069 Calculates the sine, cosine, or a linear ex trapola- tion of the source data. Symbol AP ...

  • Omron CP1E-E@@D@-@ - page 255

    2-219 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Special Math Instructions 2 APR  Linear Extrapolation Function • Linear Extrapolation (C = Da ta area addre ss) APR(069) linear extr apolation is specified when C is a word address. The content of word C spec ifies the number of coordinates in a data table star ting at C+2, ...

  • Omron CP1E-E@@D@-@ - page 256

    2 Instructions 2-220 CP1E CPU Unit Instructions Reference Manual(W483)  Operand Specifications Area W ord ad dresses Indirect DM addresses Constants CF Pulse bits TR bits CIO WR HR AR T C DM @DM *DM C, S OK OK OK OK OK OK OK OK OK OK --- --- --- R --- C 0 3 14 13 12 11 9 1 0 87654 21 15 0 0 0 01 00 Floating-point specification for S and D 0: Int ...

  • Omron CP1E-E@@D@-@ - page 257

    2-221 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Special Math Instructions 2 APR Flag s Function  Operation of the Linear Extrapolation Function APR(069) processes th e input data specified in S with the f o llowing equation and th e line-segment data (X n , Y n ) specified in the table beginning at C+1. Th e result is outp ...

  • Omron CP1E-E@@D@-@ - page 258

    2 Instructions 2-222 CP1E CPU Unit Instructions Reference Manual(W483)  16-bit Unsigned BCD Data The input data a nd/or the output data can be 16-bit unsigned BCD data. Also, the lin- ear e xtrapolation function ca n be set to operate on the v alue specified in S directly or on X m -S . (X m is the maximum v alue of X in the line-segment da ta.) ...

  • Omron CP1E-E@@D@-@ - page 259

    2-223 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Special Math Instructions 2 APR Sample pr ogram  Sine Function (C: #0000) The f ollowing e xample shows APR(069) used to calculate the sine of 30 ° . (SIN(30) = 0.5000)  Cosine Function (C: #0001) The f ollowing e xample shows APR(069) used to calculate the cosine of 30 ? ...

  • Omron CP1E-E@@D@-@ - page 260

    2 Instructions 2-224 CP1E CPU Unit Instructions Reference Manual(W483) This e xample shows ho w to construct a linear extrapol ation with 12 coordinates . The bloc k of data is continuous, as it m ust be, from D0 to D26 (C to C + (2 × 12 + 2)). The input data is taken from CIO 10, and the result is output to C IO 11. In this case, the source word, ...

  • Omron CP1E-E@@D@-@ - page 261

    2-225 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Special Math Instructions 2 APR • Using 32-bit Sign ed Binar y Data In this e x ample , APR(069) is used to con vert the fluid height i n a tank to flui d volume based on the shape of the holding tank. C+1 C+2 C+3 C+4 C+5 C+6 C+7 C+8 C+ (4n+1) C+ (4n+2) C+ (4n+3) C+ (4n+4) C+ ...

  • Omron CP1E-E@@D@-@ - page 262

    2 Instructions 2-226 CP1E CPU Unit Instructions Reference Manual(W483) • Using Floating-point Data In this exa mple, APR(069) is used to con vert the flui d height in a tank to fl uid v olume based on the shape of the holding tank. C+1 C+2 C+3 C+4 C+5 C+6 C+7 C+8 C+ (4n+1) C+ (4n+2) C+ (4n+3) C+ (4n+4) C+ (4m+1) C+ (4m+2) C+ (4m+3) C+ (4m+4) X 0 ...

  • Omron CP1E-E@@D@-@ - page 263

    2-227 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Special Math Instructions 2 BCNT BCNT Applicable Pr ogram Areas Operands N: Number of words The number of words m ust be 0001 to FFFF (1 to 65,535 words).  Operand Specifications Flag s Function T Instruction Mnemonic V ariations Function code Function BIT COUNTER BC NT @BCNT ...

  • Omron CP1E-E@@D@-@ - page 264

    2 Instructions 2-228 CP1E CPU Unit Instructions Reference Manual(W483) Precautions • Some time will be required to complete BCNT(067) if a large n umber of words is specified. Ev en if an interrupt occurs, ex ecution of this instr uction will not be interrupted and e x ecution of the interrupt task will be star ted after ex ecution of BCNT(067) h ...

  • Omron CP1E-E@@D@-@ - page 265

    2-229 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Floating-po int Math Instructions 2 Floating-point Math Instructions The Floating-point Math Instr uctio ns conv er t data and perf or m flo ating-point ar ithmetic operations.  Data Format Floating-point data expresses re al numbers using a sign, e xponent, and mant issa. Wh ...

  • Omron CP1E-E@@D@-@ - page 266

    2 Instructions 2-230 CP1E CPU Unit Instructions Reference Manual(W483)  Writing Floating-point Data When floating-point is spe cified f or the data f or mat in the I/O memor y edit displa y in the CX-Program- mer , standard decimal numbers input in the displa y are automatically conv er ted to the floating-point for- mat shown abo ve (IEEE754-f ...

  • Omron CP1E-E@@D@-@ - page 267

    2-231 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Floating-po int Math Instructions 2 (2) Non-normalized Numbers Non-nor malized numbers e xpress real numbers with very small absolute values. The sign bit will be 0 f or a positiv e number and 1 f or a negativ e number . The e xponent (e) will be 0, and the real ex ponent will b ...

  • Omron CP1E-E@@D@-@ - page 268

    2 Instructions 2-232 CP1E CPU Unit Instructions Reference Manual(W483) (3) Precautions in Handling Special V alues The f ollowing precautions apply to handling zero , infinity , and NaN. • The sum of positiv e zero and ne gativ e zero is positiv e zero . • The diff erence between zeros of the same sign is positiv e zero . • If any operand is ...

  • Omron CP1E-E@@D@-@ - page 269

    2-233 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Floating-po int Math Instructions 2 FIX/FIXL FIX/FIXL Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function FLOA TING T O 16-BIT FIX @FIX 450 Conv er ts a 32-bit floating-point value to 16-bit signed binary d ...

  • Omron CP1E-E@@D@-@ - page 270

    2 Instructions 2-234 CP1E CPU Unit Instructions Reference Manual(W483) Function  FIX FIX(450) con v er ts the integer por tion of the 32-bit floating-poin t number in S+1 and S (IEEE7 54-f ormat) to 16-bit signed binar y data and places the result in R . Only the integer por tion of the fl oating-point da ta is conv er ted, and the fr action por ...

  • Omron CP1E-E@@D@-@ - page 271

    2-235 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Floating-po int Math Instructions 2 FL T/FL TL FL T/FL TL Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function 16-BIT T O FLOA TING F L T @FL T 452 Conv er ts a 16-bit signed binar y value to 32-bit floating ...

  • Omron CP1E-E@@D@-@ - page 272

    2 Instructions 2-236 CP1E CPU Unit Instructions Reference Manual(W483) Function  FL T FL T(452) converts the 16-bit signed binar y v alue in S to 32-bit floating-point data (IEEE754-format) and places the result in R+1 and R. A single 0 is added after the decimal point in the floatin g-point result. Only v alues within the range of -32,768 to 32 ...

  • Omron CP1E-E@@D@-@ - page 273

    2-237 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Floating-po int Math Instructions 2 +F , –F , *F , /F +F , –F , *F , /F Applicable Pr ogram Areas Operands  Operand Specifications Instruction Mnemonic V ariations Function code Function FLOA TING-POINT ADD +F @+F 454 Adds two 32-bit floating-point numbers and places the ...

  • Omron CP1E-E@@D@-@ - page 274

    2 Instructions 2-238 CP1E CPU Unit Instructions Reference Manual(W483) Flags Function The data specified in A u/Mi/Md/Dd and the data sp ecified in AD/Su/Mr/ Dr are added (+F), subtracted (-F), multiplied (*F), or divided (/F) as single-precision floating-point data (32 bits: IEEE754) and output to R+1, R.  +F  -F Name Label Operation Error F ...

  • Omron CP1E-E@@D@-@ - page 275

    2-239 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Floating-po int Math Instructions 2 +F , –F , *F , /F  *F  /F • If the absolute value of the result is greater than th e maximum value that can be e xpressed as float- ing-point data, the Overflo w Flag will tur n ON and the result will be output as ±∞ . • If the ...

  • Omron CP1E-E@@D@-@ - page 276

    2 Instructions 2-240 CP1E CPU Unit Instructions Reference Manual(W483)  FLO A TING-POINT MUL TIPL Y (*F) Note 1 The results could be zero (including underflo ws), a numeral, + ∞ , or – ∞ . ER The Error Flag will be tur ned ON and the instr uction will not be ex ecuted.  FLO A TING-POINT DIVIDE (/F) Note 1 The results will be zero f or u ...

  • Omron CP1E-E@@D@-@ - page 277

    2-241 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Floating-po int Math Instructions 2 =F , <>F , <F , <=F , >F , >=F =F , <>F , <F , <=F , >F , >=F Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function Single-precision Flo ...

  • Omron CP1E-E@@D@-@ - page 278

    2 Instructions 2-242 CP1E CPU Unit Instructions Reference Manual(W483) Function  Options With the three input types and six symbols, there are 18 different possib le combinations. The input compar ison instr uction compares the data specified in S1 and S2 as single-p recision floating point v alues (32-bit IEEE754 data ) and creates a n ON e xe ...

  • Omron CP1E-E@@D@-@ - page 279

    2-243 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Floating-po int Math Instructions 2 =F , <>F , <F , <=F , >F , >=F Precautions • Input comparison instr uctions cannot be used as ri ght-hand instr uctions, i.e . , another instruction must be used be tween them and th e right bus bar . Sample pr ogram When C ...

  • Omron CP1E-E@@D@-@ - page 280

    2 Instructions 2-244 CP1E CPU Unit Instructions Reference Manual(W483) FSTR Applicable Pr ogram Areas Operands C: First Contr ol W ord  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function FLOA TING-POINT TO ASCII FSTR @FSTR 448 Expresses a 32-bit floating-point value (IEEE754- format) in standard decimal notatio ...

  • Omron CP1E-E@@D@-@ - page 281

    2-245 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Floating-po int Math Instructions 2 FSTR Function FSTR(448) e xpresses the 32- bit floating-point nu mber in S+1 and S (IEEE754-f or mat) in decimal nota- tion or scientific notation according to the control data in words C to C+2, con ver ts the number to ASCII te xt, and outpu ...

  • Omron CP1E-E@@D@-@ - page 282

    2 Instructions 2-246 CP1E CPU Unit Instructions Reference Manual(W483)  Storage of ASCII T ext After the floating-point nu mber is con v er ted to ASCII text, the ASCII characters are stored in the desti- nation words beginning with D , as shown in the follo wing dia grams . Diff erent storage methods are used f or decimal notation and scientifi ...

  • Omron CP1E-E@@D@-@ - page 283

    2-247 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Floating-po int Math Instructions 2 FSTR • Limits on the Number of Digits in the Integer P ar t 1) Decimal Notation (C = 0 hex) • When there is no fractional par t (C +2 = 0 he x): 1 ≤ Number of Integer Digits ≤ 24-1 • When there is a fractional pa r t (C+2 = 1 to 7 he ...

  • Omron CP1E-E@@D@-@ - page 284

    2 Instructions 2-248 CP1E CPU Unit Instructions Reference Manual(W483)  Con ver ting to ASCII T e xt in Scientific Notation When CIO 0.00 is ON in the follo wing e xample, FSTR(448) con v er ts the floating-point data in D1 and D0 to scientific-notat ion ASCII te xt and writes the ASCII te xt to t he destination words beginning with D100. The co ...

  • Omron CP1E-E@@D@-@ - page 285

    2-249 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Floating-po int Math Instructions 2 FV AL FV AL Applicable Pr ogram Areas Operands  Operand Specifications Flag s Function FV AL(449) conv er ts the sp ecified ASCII text number (sta rting at word S) to a 32-bit floatin g-point num- ber (IEEE754-f ormat) and outputs the resul ...

  • Omron CP1E-E@@D@-@ - page 286

    2 Instructions 2-250 CP1E CPU Unit Instructions Reference Manual(W483) • Scientific Notation Real numbers e xpressed as an in teger par t, fractional pa r t, and exponent par t. Example: 1.2456E-2 (1.2 456 × 10 - 2 ) The data f or mat (decimal or scientific notation) is detected automatically . The ASCII te xt must be stored in S and subsequent ...

  • Omron CP1E-E@@D@-@ - page 287

    2-251 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Floating-po int Math Instructions 2 FV AL  Storage of ASCII T ext The f ollowing diagrams show ho w the ASCII text nu mber is conv er ted to floating-point data. Different conv ersion methods are used f or numbers stored with decimal notation and scientific notation. 00 S FV ...

  • Omron CP1E-E@@D@-@ - page 288

    2 Instructions 2-252 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram  Con ver ting ASCII T ext in Decimal Notation to Floating-point Data When CIO 0.00 is ON in the f ollowing e xample, FV AL(449) conv e r ts the specifie d decimal-notation ASCII te xt number in the source words star ting at D0 to floating-point data and writes ...

  • Omron CP1E-E@@D@-@ - page 289

    2-253 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) T able Data Processing Instructions 2 SW AP T able Data Pr ocessing Instructions SW AP Applicable Pr ogram Areas Operands N: Number of w ords N specifies the number of w ord s in the range and must be 0001 to FFFF he xadecimal (or &1 to &65,535). R1: First w ord in range ...

  • Omron CP1E-E@@D@-@ - page 290

    2 Instructions 2-254 CP1E CPU Unit Instructions Reference Manual(W483) Function SW AP (637) s witches the position of the two bytes in all of the wo rds in the range of mem- or y from R1 to R1+N-1. Hint • This instruction can be used to rev erse the or der of ASCII-code charac ters in each word. Sample pr ogram When CIO 0.00 is ON in the fo llo w ...

  • Omron CP1E-E@@D@-@ - page 291

    2-255 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) T able Data Processing Instructions 2 FCS FCS Applicable Pr ogram Areas Operands  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function FRAME CHECKSUM FCS @FCS 180 Calculates the FCS value f or the specified range and outputs the result in ASCI ...

  • Omron CP1E-E@@D@-@ - page 292

    2 Instructions 2-256 CP1E CPU Unit Instructions Reference Manual(W483) Function FCS(180) calculat es the FCS v alue f or W units of data beginning with the data in R1, con verts the v alue to ASCII code, and outputs the result to D (f or bytes) or D+1 and D (f or words). The settings in C+1 determine whether the u nits are words or b ytes, whether ...

  • Omron CP1E-E@@D@-@ - page 293

    2-257 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 PID A T Data Contr ol Instructions PID A T Applicable Pr ogram Areas Operands C: First P arameter W ord Instruction Mnemonic V ariations Function code Function PID CONTROL WITH A U T O TUNING PIDA T --- 191 Executes PID control according to the specif ...

  • Omron CP1E-E@@D@-@ - page 294

    2 Instructions 2-258 CP1E CPU Unit Instructions Reference Manual(W483)  Operand Specifications Flags Function When the e x ecution condit ion is ON, PID A T(191) carries out target value filtered PID co ntrol with two degrees of freedom according to the parameters designated b y C (set value , PID constant, etc.). It tak es the specified input r ...

  • Omron CP1E-E@@D@-@ - page 295

    2-259 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 PID A T The f ollowing flo wchar t show s the autot uning procedure: Note 1 If autotuning is interrupted by tur ning OFF the A T Command Bit during autotuning, PID control will star t with the PID constants that were being used before autotuning began ...

  • Omron CP1E-E@@D@-@ - page 296

    2 Instructions 2-260 CP1E CPU Unit Instructions Reference Manual(W483) Hint • PID A T(191) is ex ecuted as if the ex ecution co ndition was a ST OP-R UN signal. PID calculations are e xecuted when the e xecution condit ion remains ON for the ne xt cycle after C+11 to C+40 are initial- ized. Theref ore, when using the Alwa ys ON Flag (ON) as an e ...

  • Omron CP1E-E@@D@-@ - page 297

    2-261 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 PID A T Bloc k Diagram f or T arget V alue PID with T w o Degrees of Freedom When ov ershooting is prev ented with simple PID control, stabilization of disturbances is slo wed (1). If stabilization of disturbances is speeded up, on the othe r hand, ov ...

  • Omron CP1E-E@@D@-@ - page 298

    2 Instructions 2-262 CP1E CPU Unit Instructions Reference Manual(W483) Note 1 When the unit is designate d as 1, the range is from 1 to 8,191 times the per iod. When th e unit is designated as 9, the range is from 0.1 to 819.1 s. When 9 is designate d, set the integral and der ivativ e times to within a range of 1 to 8,191 times the sampling per io ...

  • Omron CP1E-E@@D@-@ - page 299

    2-263 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 PID A T Sampling P eriod and Cycle Time The sampling period can be designated in units of 10 ms (0.01 to 99.9 9 s), but the actual PID action is deter mined by a combinat ion of the sampling period and the time of PID instruct ion e x ecution (with ea ...

  • Omron CP1E-E@@D@-@ - page 300

    2 Instructions 2-264 CP1E CPU Unit Instructions Reference Manual(W483) PID contr ol  Proportional Action (P) Propor tional action is an op eration in which a proportional band is es tablished with re spect to the set value (SV), and within that band the manipulat ed variab le (MV) is made pr opor tional to the de viation. An e xample fo r rev er ...

  • Omron CP1E-E@@D@-@ - page 301

    2-265 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 PID A T  Deriv ative Action (D) Propor tional action and integral ac tion both mak e corrections with respect to the co ntrol results, so there is ine vitably a respon se dela y . Derivativ e action compensa tes f or that dra wback. In response to ...

  • Omron CP1E-E@@D@-@ - page 302

    2 Instructions 2-266 CP1E CPU Unit Instructions Reference Manual(W483) Direction of Action When using PID control, select either of the f ollo wing two control directions . In either direction, the MV increases as the diff erence between the SV and th e PV increases. • Forw ard action: MV is increased when the PV is larger than the SV . • Rev e ...

  • Omron CP1E-E@@D@-@ - page 303

    2-267 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 PID A T Sample pr ogram  Interrupting PID Contr ol to P erform A utotuning • At the rising edge of CIO 0.00 (OFF to ON), the wor k area in D211 to D240 is initialized according to the para meters (sho wn below) set in D200 to D208. After the work ...

  • Omron CP1E-E@@D@-@ - page 304

    2 Instructions 2-268 CP1E CPU Unit Instructions Reference Manual(W483)  Starting PID A T(191) with A utotuning  Interrupting A utotuning Bef ore Completion A utotuning can be interrupted by turning bit 15 of D209 (C+9) from ON to OFF . PID control will be restar ted with the P , I, and D constants that we re in eff ect bef ore autotuning w as ...

  • Omron CP1E-E@@D@-@ - page 305

    2-269 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 TPO TPO Applicable Pr ogram Areas Operands S: Input W ord Specifies the input word cont aining the input duty r atio or manipulated v ariable. • Input duty ratio: 000 0 to 2710 he x (0.00% to 100.00%) • Input manipulated v ariable (See note .): 00 ...

  • Omron CP1E-E@@D@-@ - page 306

    2 Instructions 2-270 CP1E CPU Unit Instructions Reference Manual(W483) R: Pulse Output Bit Specifies the destination output bit for the pulse output. Nor mally , specify an output bit allocated t o a T r ansistor Output Unit and connect a solid state rela y to the T ransistor Output Unit.  Operand Specifications Flags Function Receiv es a duty r ...

  • Omron CP1E-E@@D@-@ - page 307

    2-271 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 TPO In this case, set the same v a lue f o r the PID Control instruction’ s outp ut range and the TPO(685) instruc- tion’ s manipulated variab le range. F o r example , when the PID Control instr uction’ s output range and the TPO(685) instructi ...

  • Omron CP1E-E@@D@-@ - page 308

    2 Instructions 2-272 CP1E CPU Unit Instructions Reference Manual(W483) • The parameters (in C to C+3) are read in real time each ti me that the instru ction is e x ecuted. When changing the par ameters , change all of them at the same time so that diff erent sets of par ameters are not mixed. • The output (R) is turned ON/OFF when the instructi ...

  • Omron CP1E-E@@D@-@ - page 309

    2-273 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 TPO • Input time setting = 2 (Use highe r valu e.) • Input time setting = 3 ( Continuous adjustment) • The output limite r function (bits 12 to 15 of C) can be enabled to restrict (saturate) outp ut when it is outside the range between the outpu ...

  • Omron CP1E-E@@D@-@ - page 310

    2 Instructions 2-274 CP1E CPU Unit Instructions Reference Manual(W483) Precautions When using TPO(685) in combination with PID A T(191) in a cyclic task and also using an interrupt ta s k, temporarily disable interrupts by e x ecuting DI(693) (DISABLE INTERRUPTS) ahead PID A T(191) and TPO(685). If interrupts are not disabled and an interrupt occur ...

  • Omron CP1E-E@@D@-@ - page 311

    2-275 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 TPO  Using TPO(685) Alone When CIO 0.00 is ON, TPO(685) tak es the duty ratio in D10, con v er ts the duty ratio to a tim e-propor- tional output, and outputs the pulses to bit 00 of CIO 100. In this case, the control period is 1 s and the outpu t ...

  • Omron CP1E-E@@D@-@ - page 312

    2 Instructions 2-276 CP1E CPU Unit Instructions Reference Manual(W483) SCL Applicable Pr ogram Areas Operands P1: First P arameter W ord  Operand Specifications Instruction Mnemonic V ariations Functio n code Function SCALING SCL @SCL 194 Converts unsigned b inary d ata into unsigned BCD data according to the specified linear function. Symbol SC ...

  • Omron CP1E-E@@D@-@ - page 313

    2-277 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 SCL Flag s Function SCL(194) is used to conv er t the unsigned binar y data contained in the source word S into unsigned BCD data and place the result in the result w ord R according to the linear function defined by points (As, Ar) and (Bs , Br). The ...

  • Omron CP1E-E@@D@-@ - page 314

    2 Instructions 2-278 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram In the f ollowing e xample, it is assume that an analog signal from 1 to 5 V is conv er ted and input to D0 as 0000 to 0F A0 hexadecimal. SCL(1 94) is used to conv er t (scale) th e v alue in CIO 200 to a v alue between 0 and 300 BCD . When CIO 0.00 is ON, the co ...

  • Omron CP1E-E@@D@-@ - page 315

    2-279 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 SCL In this e xample, v alues from 0000 to 00C8 he xadecimal will be con verted to negative v alues . SCL(194), how ev er , can output only unsigned BCD values from 0000 to 9999, so 0000 BCD will be output when- e ve r the contents of D0.00 is betwe e ...

  • Omron CP1E-E@@D@-@ - page 316

    2 Instructions 2-280 CP1E CPU Unit Instructions Reference Manual(W483) SCL2 Applicable Pr ogram Areas Operands P1: First P arameter W ord  Operand Specifications Instruction Mnemonic V ariations Functio n code Function SCALING 2 SCL2 @SCL2 486 Conv er ts signed binar y data into signed BCD data according to the specified linear function. An offs ...

  • Omron CP1E-E@@D@-@ - page 317

    2-281 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 SCL2 Flag s Function SCL2(486) is used to conv er t the signed binary dat a contained in the sour ce word S into signed BCD data (the BCD data contains the absolute v a lue and the Carr y Flag shows the sign) and place the result in the result word R ...

  • Omron CP1E-E@@D@-@ - page 318

    2 Instructions 2-282 CP1E CPU Unit Instructions Reference Manual(W483) Hint • SCL2(486) can be used to scale the results of an alog signal conv ersion values from Analog Input Units according to user -defined scale para meters . For e xample, if a 1 to 5-V input to an Analog Input Unit is input to memor y as 0000 to 0F A0 he xadecimal, the value ...

  • Omron CP1E-E@@D@-@ - page 319

    2-283 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 SCL2  Scaling 1 to 5-V Analog Input to –200 to 200 In the f ollowing e xample, it is assume that an analog signal from 1 to 5 V is con verted and input to CIO 3 as 0000 to 1770 he xadecimal. SCL2( 486) is used to conv er t (scale) t he value in C ...

  • Omron CP1E-E@@D@-@ - page 320

    2 Instructions 2-284 CP1E CPU Unit Instructions Reference Manual(W483) SCL3 Applicable Pr ogram Areas Operands P1: First P arameter W ord Instruction Mnemonic V ariations Functio n code Function SCALING 3 SCL3 @SCL3 487 Conv er ts signed BCD data into signed binar y data according to the specified linear function. An offset can be input in defining ...

  • Omron CP1E-E@@D@-@ - page 321

    2-285 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 SCL3  Operand Specifications Flag s Function SCL3(487) is used to con v er t the signe d BCD data (the BCD data conta ins the absolute value and the Carr y Flag shows the sign) contained in the source word S into signed binary data and place the re ...

  • Omron CP1E-E@@D@-@ - page 322

    2 Instructions 2-286 CP1E CPU Unit Instructions Reference Manual(W483) Hint SCL3(487) is used to con v er t data using a user-defined scale to signed binary f or Analog Output Units . F or e xample, SCL3( 487) can con ve r t 0 to 200 ° C to 0000 to 1770 (he x) and output an analog outpu t signal 1 to 5 V from the Analog Output Unit. Sample pr ogra ...

  • Omron CP1E-E@@D@-@ - page 323

    2-287 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 A VG AV G Applicable Pr ogram Areas Operands N: Number of Cycles The number of cycles must be between 0001 and 0040 he xadecimal (0 to 64 cycles). R: Result First W ord and R+1: Fir st W ork Area W or d Note R to R+N+1 must be in the same area.  Op ...

  • Omron CP1E-E@@D@-@ - page 324

    2 Instructions 2-288 CP1E CPU Unit Instructions Reference Manual(W483) Function Precautions The processing inf or mation (R+1) is cleared to 0000 each time the e x ecution condition changes from OFF to ON. But the processing inf or mation (R+1) will not be cleared to 0000 the first time the program is e xecuted at the star t of operation. If A V G( ...

  • Omron CP1E-E@@D@-@ - page 325

    2-289 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Data Control Instructions 2 A VG • In the f ollowing e xample, the content of CIO 40 is set to #0000 a nd then incremented by 1 each cycle . • F or the first two cycles, A V G(195) move s the content of CIO 4 0 to D1002 and D1003. The contents of D1001 will also change (whic ...

  • Omron CP1E-E@@D@-@ - page 326

    2 Instructions 2-290 CP1E CPU Unit Instructions Reference Manual(W483) Subr outines Instructions SBS Applicable Pr ogram Areas Operands N: Subr outine number Specifies the subroutine number betw een 0 and 127 decimal.  Operand Specifications Combined-use instructions SBN (subroutine entr y) inst ructions and RET (subrou tine retur n) instruction ...

  • Omron CP1E-E@@D@-@ - page 327

    2-291 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Subroutines Instructions 2 SBS Function SBS(091) calls the subroutine with the specified subroutin e number . The subrou- tine is the progra m section between SBN(092) and RET(09 3). When the sub- routine is completed, program e xecution continues with the ne xt instruction afte ...

  • Omron CP1E-E@@D@-@ - page 328

    2 Instructions 2-292 CP1E CPU Unit Instructions Reference Manual(W483) Precautions • The subroutine n umber must be uni que f or each subroutine . Y ou cannot use the same numb er f or more than one sub- routine. • Each subroutine must hav e a unique subroutine number . Do not use the same subroutine n umber f or more than one subroutine . • ...

  • Omron CP1E-E@@D@-@ - page 329

    2-293 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Subroutines Instructions 2 SBS Sample pr ogram  Sequential (Non-nested) Subr outines When CIO 0.00 is ON in the f o llowing e xample, subroutine 1 is e xecuted and progr am e x ecution retur ns to the ne xt instruction after SBS(091) 1. When CIO 0.01 is ON, subroutine 2 is ex ...

  • Omron CP1E-E@@D@-@ - page 330

    2 Instructions 2-294 CP1E CPU Unit Instructions Reference Manual(W483)  Nested Subroutines When CIO 0.00 is ON in the f ollo wing e xample, subroutine 1 is e xecuted . If CIO 0.01 is ON, subroutine 2 is e x ecuted from within su broutine 1 and program e xecution returns to the next instruction after SBS(091) 2 when subrou tine 2 is completed. Ex ...

  • Omron CP1E-E@@D@-@ - page 331

    2-295 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Subroutines Instructions 2 SBN/RET SBN/RET Applicable Pr ogram Areas  SBN  RET Operands  SBN N: Subroutine number Specifies the subroutin e number between 0 and 127 decimal.  Operand Specifications Combined-use instructions SBS (subroutine call) instruction Instructi ...

  • Omron CP1E-E@@D@-@ - page 332

    2 Instructions 2-296 CP1E CPU Unit Instructions Reference Manual(W483) Flags  SBN/RET There are no flags affected b y this instruction. Function  SBN  RET When progr am ex ecution reaches RET( 093), it is automatically retur ned to the ne xt instruction after the SBS(091) instruction that called the subroutine. Precautions • Place the su ...

  • Omron CP1E-E@@D@-@ - page 333

    2-297 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Subroutines Instructions 2 SBN/RET • The step instructions, STEP(008 ) and SNXT(009) cannot be used in subroutines. • Place the subroutines after the main progr am and just befo re the END(001) instruction in the program f or each task. If par t of the main progr am is place ...

  • Omron CP1E-E@@D@-@ - page 334

    2 Instructions 2-298 CP1E CPU Unit Instructions Reference Manual(W483) Interrupt Contr ol Instructions CP1E CPU Units suppor t the f ollowing interrupts. Outline of Interrupt Contr ol Instructions  SET INTERR UPT MASK: MSKS(690) Both I/O interrupt tasks and sche duled interrupt tasks are masked (disab led) when the PLC enters R UN mode. M SKS(69 ...

  • Omron CP1E-E@@D@-@ - page 335

    2-299 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Interrupt Control Instructions 2 Related Memory Area W ords Name Address Operation Maximum Interrupt T ask Processing Time A440 The maximum processing time f or an interrupt task is stored in binary data in 0.1-ms units and is cleared at the start of operation. Interrupt T ask w ...

  • Omron CP1E-E@@D@-@ - page 336

    2 Instructions 2-300 CP1E CPU Unit Instructions Reference Manual(W483) MSKS Applicable Pr ogram Areas Operands (1) I/O Interrupt T ask Note When the up/down diff erentiation setting is changed, all detected interr upt inputs will be clea red. (2) Resetting and Starting Scheduled Interrupts Instruction Mnemonic V ariations Functio n code Function SE ...

  • Omron CP1E-E@@D@-@ - page 337

    2-301 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Interrupt Control Instructions 2 MSKS  Operand Specifications Flag s Function When the program e xecution starts, the interr upt in puts that generate I/O int errupt tasks are masked (disabled), and the internal timers cr eating the timer interr upts that generate scheduled i ...

  • Omron CP1E-E@@D@-@ - page 338

    2 Instructions 2-302 CP1E CPU Unit Instructions Reference Manual(W483) Precaution • Be sure that the time interval is longer than the time require d to e x ecute the scheduled interrupt task. • T o accurately control th e time to the first interrupt and the interrupt interval, prog ram CLI(691) to set the time to the first schedule interrupt ju ...

  • Omron CP1E-E@@D@-@ - page 339

    2-303 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Interrupt Control Instructions 2 CLI CLI Applicable Pr ogram Areas Operands (1) Clearing/Retaining an I/O Inte rrupt T ask’ s Recorded Interrupt Inputs (2) Setting the Time to the First Scheduled Interrupts Instruction Mnemonic V ariations Function code Function CLEAR INTERRUP ...

  • Omron CP1E-E@@D@-@ - page 340

    2 Instructions 2-304 CP1E CPU Unit Instructions Reference Manual(W483) (3) Clearing/Retaining High-spee d Counter Inter rupts  Operand Specifications Flags Function Depending on the v alue of N, CLI (691) clears the sp ecified recorded I/O interrup ts, sets the time bef ore e x ecution of the first scheduled inter rupt, or clears the specified r ...

  • Omron CP1E-E@@D@-@ - page 341

    2-305 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Interrupt Control Instructions 2 CLI (2) N = 4: Setting the Time to the First Scheduled Interrupt T ask When N is 4, the content of C specifies the time inter v al to the fir st scheduled interrupt task. (3) N = 10 or 15: Clearing High -speed Counter Inter rupts When N is 10 or ...

  • Omron CP1E-E@@D@-@ - page 342

    2 Instructions 2-306 CP1E CPU Unit Instructions Reference Manual(W483) DI Applicable Pr ogram Areas Flags Function DI(693) is e xecuted from the main program to temp or arily disable all interrupt tasks (I/O interrupts, scheduled interrupts). Precautions All interrupt tasks will remain disabled until EI(694) is e x ecuted. DI(693) cannot be e xecut ...

  • Omron CP1E-E@@D@-@ - page 343

    2-307 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Interrupt Control Instructions 2 EI EI Applicable Pr ogram Areas Flag s Function • EI(694) is e xecuted from the main progr am to tempo rarily enabl e all interrupt tasks that were disabled by DI(693). DI(693) disables all interrupt s (I/O interr upts, sc heduled interr upts). ...

  • Omron CP1E-E@@D@-@ - page 344

    2 Instructions 2-308 CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructions INI Applicable Pr ogram Areas Operands P: P or t Specifier Instruction Mne- monic Va r i a - tions Function code Function MODE CONTROL INI @INI 880 INI(880) can be used to ex ecute the following operations • T o star t comparison wi ...

  • Omron CP1E-E@@D@-@ - page 345

    2-309 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 INI C: Control Data NV : First W ord with Ne w PV  Operand Specifications Flag s Function INI(880) perf or ms the operation spe cified in C f or the por t sp ecified in P . The possible combinations of operations and por ts are ...

  • Omron CP1E-E@@D@-@ - page 346

    2 Instructions 2-310 CP1E CPU Unit Instructions Reference Manual(W483)  Changing a PV (C = 0002 hex)  Stopping Pulse Output (P = 0000, 0001 or 1000 hex and C = 0003 he x) If C is 0003 hex, INI(8 80) immediately stops pulse output f or the specified por t. If this instruction is ex e- cuted when pulse output is already stopped, then the pulse ...

  • Omron CP1E-E@@D@-@ - page 347

    2-311 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 PR V PR V Applicable Pr ogram Areas Operands P: P or t Specifier C: Control Data Instruction Mnemonic V ariations Function code Function HIGH-SPEED COUNTER PV READ PR V @PR V 881 PR V(881) reads the High-speed counter PV and pulse ...

  • Omron CP1E-E@@D@-@ - page 348

    2 Instructions 2-312 CP1E CPU Unit Instructions Reference Manual(W483) D: First Destination W ord  Operand Specifications Flags Function PR V(881) reads the data specified in C for the por t specified in P . The possible combinations of data and por ts are shown in the f ollowing tab le. Area W ord ad dresses Indirect DM ad dresses Constants CF ...

  • Omron CP1E-E@@D@-@ - page 349

    2-313 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 PR V  Reading a PV (C = 0000 hex)  Reading Status (C = 0001 hex) P ort and mode Operation Setting range Pulse output (P = 0000 or 0001 he x) The present value of the pulse output is stored in D and D+1. 8000 0000 to 7FFF FFFF ...

  • Omron CP1E-E@@D@-@ - page 350

    2 Instructions 2-314 CP1E CPU Unit Instructions Reference Manual(W483)  Reading Pulse Output or High-speed Counter Frequency (C = 00 @ 3 he x) If C is 00 @ 3 he x, PR V(881) reads the frequency being output from pulse output 0 or 1 or the frequency being input to high-speed counter 0 and stor es it in D and D+1. 0000 or 0001 he x (Reading the fr ...

  • Omron CP1E-E@@D@-@ - page 351

    2-315 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 CTBL CTBL Applicable Pr ogram Areas Operands P: P or t specifier C: Control data Instruction Mnemonic V ariations Function code Function REGISTER COMP ARISON T ABLE CTBL @CTBL 882 CTBL(882) is used to register a comparison table an ...

  • Omron CP1E-E@@D@-@ - page 352

    2 Instructions 2-316 CP1E CPU Unit Instructions Reference Manual(W483) TB: First comparison tab le wor d • TB is the first w ord of the comparison table. Th e structure of the compar ison table depends on the type of comparison being performed. F or target v alue comparison, the length of the compa rison table is determined by the numb er of tar- ...

  • Omron CP1E-E@@D@-@ - page 353

    2-317 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 CTBL Flag s Function CTBL(882) registers a comp arison table and star ts comparison for the port specified in P and the method specified in C. Once a comparison table is registered, i t is va lid until a different tab le is regis- ...

  • Omron CP1E-E@@D@-@ - page 354

    2 Instructions 2-318 CP1E CPU Unit Instructions Reference Manual(W483)  Range Comparison The corresponding interrupt task is called an d ex ecuted when the PV enters a set range. • The same interrupt task numb er can be specified f or more than one target v alue. • The range comparison tabl e contains 6 ra nges, each of which is defi ned by ...

  • Omron CP1E-E@@D@-@ - page 355

    2-319 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 SPED SPED Applicable Pr ogram Areas Operands P: P or t specifier  Operand Specifications Instruction Mnemonic V ariations Function code Function SPEED OUTPUT SPED @SPED 885 SPED(885) is used to set the output pulse frequency f o ...

  • Omron CP1E-E@@D@-@ - page 356

    2 Instructions 2-320 CP1E CPU Unit Instructions Reference Manual(W483) Flags Function In independent mode, pulse output will stop automatically when the number of pulses set with PULS(886) in adv ance hav e been output. In contin uous mode, pulse output will continue until stopped from the program. An error will occur if the mode is changed between ...

  • Omron CP1E-E@@D@-@ - page 357

    2-321 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 SPED  Independent Mode P ositioning When independent mode operation is started, pulse output will be continued until the specified number of pulses has been output. Note • Pulse outpu t will stop immediately if the CPU Unit is ...

  • Omron CP1E-E@@D@-@ - page 358

    2 Instructions 2-322 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram When CIO 0.00 tur ns ON in the follo wing programmi ng e xample, PULS(886) sets the number of output pulses f or pulse output 0. An absolute value of 5,000 pulses is set. SPED(885) is ex ecuted next to start pulse output using the pulse + direction method in t he ...

  • Omron CP1E-E@@D@-@ - page 359

    2-323 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 PULS PULS Applicable Pr ogram Areas Operands P: P or t specifier T : Pulse type N and N+1: Number of pulses • The actual number of mov ement pulses that will be output are as f ollows: F or relative pulse output, the number of mo ...

  • Omron CP1E-E@@D@-@ - page 360

    2 Instructions 2-324 CP1E CPU Unit Instructions Reference Manual(W483) Flags Function PULS(886) sets the pulse ty pe and number of pulses specified in T and N for the por t specified in P . Actual output of the pulses is star ted later in the program using SPED(885) or A CC(888) in independent mode. Note • An error will occur if PULS(88 6) is ex ...

  • Omron CP1E-E@@D@-@ - page 361

    2-325 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 PLS2 PLS2 Applicable Pr ogram Areas Operands P: P or t Specifier M: Output Mode Instruction Mnemonic V ariations Function code Function PULSE OUTPUT PLS2 @PLS2 887 PLS2(887) outputs a specified number of pulses to the specified por ...

  • Omron CP1E-E@@D@-@ - page 362

    2 Instructions 2-326 CP1E CPU Unit Instructions Reference Manual(W483) S: First W ord of Settings T ab le The actual number of mov ement pulses that will be output are as f ollows: • F or relativ e pulse output, the number of mov ement pulses = the set number of pulses. • F or absolute pulse output, the number of mov ement pulses = the set numb ...

  • Omron CP1E-E@@D@-@ - page 363

    2-327 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 PLS2 Function PLS2(887) star ts pulse output on the por t specified in P using the mode specifi ed in M at the star t fre- quency specified in F (1 in diagr a m). The frequency is increased e v er y pulse control period (4 ms) at t ...

  • Omron CP1E-E@@D@-@ - page 364

    2 Instructions 2-328 CP1E CPU Unit Instructions Reference Manual(W483)  Independent Mode P ositioning Note Pulse output will stop immediately if the CPU Unit is changed to PROGRAM mode. Opera- tion Purpose Application Frequency changes Descrip tion Procedure/ instruction Starting pulse out- put Comple x trapez oidal control P ositioning with tra ...

  • Omron CP1E-E@@D@-@ - page 365

    2-329 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 PLS2 Note T r iangular Control If the specified number of pulses is less than the number requi red to reach the target freque ncy and return to zero, the function will automatical ly reduce the accelerati on/deceleration time and p ...

  • Omron CP1E-E@@D@-@ - page 366

    2 Instructions 2-330 CP1E CPU Unit Instructions Reference Manual(W483)  Switching fr om Continuous Mode Speed Contr ol to Independent Mode P ositioning Sample pr ogram When CIO 0.00 tur ns ON in the f ollowing prog ramming e xample, PLS2(887) starts pu lse output from pulse output 0 with an absolu te pulse specification of 100,000 pulses. Pulse ...

  • Omron CP1E-E@@D@-@ - page 367

    2-331 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 ACC AC C Applicable Pr ogram Areas Operands P: P or t Specifier M: Output Mode Note Use the same pulse output method when using both pulse outp uts 0 and 1. S: First W or d of Settings T able Instruction Mnemonic V ariations Functi ...

  • Omron CP1E-E@@D@-@ - page 368

    2 Instructions 2-332 CP1E CPU Unit Instructions Reference Manual(W483)  Operand Specifications Flags Function A CC(888) star ts pulse output on the por t sp ecified in P using the m ode specified in M using the target frequency and acceleration/de celer ation rate specified in S . The frequency is increa sed e very pulse control period (4 ms) at ...

  • Omron CP1E-E@@D@-@ - page 369

    2-333 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 ACC  Continuous Mode Speed Contr ol Pulse output will continue until it is stopped from the program. Note Pulse output will stop immediately if the CPU Unit is changed to PROGRAM mode . Opera- tion Purpose Application F requency ...

  • Omron CP1E-E@@D@-@ - page 370

    2 Instructions 2-334 CP1E CPU Unit Instructions Reference Manual(W483)  Independent Mode P ositioning When independent mode operation is star ted, pulse output will be continued until the specified number of pulses has been output. The deceleration point is cal culated from the n umber of output pulses and deceleration rate set in S and when tha ...

  • Omron CP1E-E@@D@-@ - page 371

    2-335 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 ACC Note T r iangular Control If the specified number of pulses is less than the number requi red to reach the target freque ncy and return to zero, the function will automatical ly reduce the accelerati on/deceleration time and pe ...

  • Omron CP1E-E@@D@-@ - page 372

    2 Instructions 2-336 CP1E CPU Unit Instructions Reference Manual(W483) ORG Applicable Pr ogram Areas Operands P: P or t Specifier C: Control Data  Operand Specifications Instruction Mnemonic V ariations Functio n code Function ORIGIN SEARCH ORG @OR G 889 ORG(889) performs an origin search or or igin return op eration. Symbol ORG Area Step progra ...

  • Omron CP1E-E@@D@-@ - page 373

    2-337 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 ORG Flag s Function ORG(889) performs an origin sear ch or origin retur n op eration for the por t specified in P using the method specified in C . The f ollowing parameters must be set in th e PLC Setup before ORG( 889) can be e x ...

  • Omron CP1E-E@@D@-@ - page 374

    2 Instructions 2-338 CP1E CPU Unit Instructions Reference Manual(W483) When the origin search operation has been completed, the Error Counter Reset Output will be turned ON. The abov e operation, howe ver , depends on the operatin g mode , origin detectio n method, and other paramete rs.  Origin Return (Bits 12 to 15 of C = 1 hex) ORG(889) star ...

  • Omron CP1E-E@@D@-@ - page 375

    2-339 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) High-speed Counter/Pulse Output Instructio ns 2 PWM PWM Applicable Pr ogram Areas Operands P: P or t Specifier F: Frequency F specifies the freque ncy of the PWM output between 2.0 and 6,553.5 Hz (0.1 Hz u nits, 0014 to FFFF he x), or between 2 and 32,000 Hz (2 Hz units, 000 2 t ...

  • Omron CP1E-E@@D@-@ - page 376

    2 Instructions 2-340 CP1E CPU Unit Instructions Reference Manual(W483)  Operand Specifications Flags Function PWM(891) outputs the frequency spec ified in F at the dut y f actor specified in D from the por t specified in P . PWM (891) can be e xecuted du ring duty-fa ctor PWM output to cha nge the duty f actor without stop- ping PWM output. Any ...

  • Omron CP1E-E@@D@-@ - page 377

    2-341 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Step Instructions 2 Step Instructions In CP1E series PLCs, STEP(008)/SNXT( 009) can be used together to create step programs. Note W or k bits are used as the control bits for A, B , C and D . Instruction Operation Diagram SNXT(009): STEP ST ART Controls progre ssion to the next ...

  • Omron CP1E-E@@D@-@ - page 378

    2 Instructions 2-342 CP1E CPU Unit Instructions Reference Manual(W483) SNXT/STEP Applicable Pr ogram Areas Operands  Operand Specifications Flags Function  SNXT(009) SNXT(009) is used in the f ollowing three wa ys: 1.T o star t step pr ogramming e xecution. 2. T o proceed to the next step control bit. 3. T o end step programming e xecution. T ...

  • Omron CP1E-E@@D@-@ - page 379

    2-343 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Step Instructions 2 SNXT/STEP Proceeding to the Ne xt Step When SNXT(009) occurs in the middle of the step program area, it is used to proceed to the ne xt step . It turns OFF the previous control bit an d tur ns ON the ne xt control bit B, f or the ne xt step, thereby starting ...

  • Omron CP1E-E@@D@-@ - page 380

    2 Instructions 2-344 CP1E CPU Unit Instructions Reference Manual(W483) Hint Related Bits Precaution • The control bit, B, m ust be in the W ork Area for STEP(008)/SNXT(009). • A control bit f o r STEP(00 8)/SNXT(009) cannot be use an ywhere else in the ladd er diagram. If the same bit is used twice, as duplication bit error will occur . • If ...

  • Omron CP1E-E@@D@-@ - page 381

    2-345 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Step Instructions 2 SNXT/STEP • STEP(008) an d SNXT(009) cannot be used inside of subr outines, inte rrupt programs , or b lock pro- grams . • Be sure that two steps are not e x ecuted during the same cycle. • The instructions t hat cannot be used within step programs are ...

  • Omron CP1E-E@@D@-@ - page 382

    2 Instructions 2-346 CP1E CPU Unit Instructions Reference Manual(W483) (1) Sequential Cont rol Step (A) W0.00 Step (B) W0.01 Step (C) W0.02 End 0.01 (Step (A) star ting condition) 0.02 (Step (A) → Step (B) transition condition) 0.03 (Step (B) → Step (C) transition condition) 0.04 (Step (C) reset conditions) Step W0.00 (A) Step W0.01 (B) Step W0 ...

  • Omron CP1E-E@@D@-@ - page 383

    2-347 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Step Instructions 2 SNXT/STEP (2) Branching Contr ol  Additional Inf ormation: • In the abov e example, where SNXT (009) is ex ecuted fo r W0.02, the branching mo ves onto the ne xt steps e ven though the same control bit is used twice . This is not pic ked up as an error i ...

  • Omron CP1E-E@@D@-@ - page 384

    2 Instructions 2-348 CP1E CPU Unit Instructions Reference Manual(W483) (3) Parallel Contr o l Step (A) W0.00 Step (B) W0.01 Step (C) W0.02 End 0.05 (Step (C) reset conditions) Step (D) W0.02 Step (E) W0.04 0.04 (When both Step (B) and Step (D) are complete, mov es to Step (E) 0.03 (Step (C) → Step (D) transition condition) 0.01 (Step (A), (C) sim ...

  • Omron CP1E-E@@D@-@ - page 385

    2-349 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Step Instructions 2 SNXT/STEP Application Examples (1) Sequential Execution SW 1 SW 2 SW 3 SW 4 Solenoid 1 Robot hand Solenoid 2 Conv ey or belt 1 Process A: Loading Conv ey or belt 2 Process B: P ar t installation Conv ey or belt 3 Process C: Inspection/Unloading Photomicro- se ...

  • Omron CP1E-E@@D@-@ - page 386

    2 Instructions 2-350 CP1E CPU Unit Instructions Reference Manual(W483) (2) Branching Execution SW A1 SW A2 SW C1 SW C2 SW D SW B2 SW B1 Process C Process B Process A Guide W eight scale Conv ey er B Conv ey er A Printer 0.01(SW A1) 0.02(SW B1) 0.03(SW A2) 0.04(SW B2) 0.05(SW D) Process A Process C End Process B Explanation of operation Products are ...

  • Omron CP1E-E@@D@-@ - page 387

    2-351 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Step Instructions 2 SNXT/STEP (3) P arallel Ex ecution SW1 SW2 SW3 SW4 SW6 SW5 SW7 Process C Process A Process D Process B Process E Conv ey er A Conv ey er C Conve yer D Conv ey er B Conv ey er E 0.05(SW7) 0.02(SW3) 0.03(SW4) Process A Process E End Process C Process B Process ...

  • Omron CP1E-E@@D@-@ - page 388

    2 Instructions 2-352 CP1E CPU Unit Instructions Reference Manual(W483) Basic I/O Unit Instructions IORF Applicable Pr ogram Areas Operands St: Starting W ord CIO 001 to CIO 099, C IO 101 to CIO 199 (C P1W Expansion I/O Unit’ s I/O Area) E: End W ord CIO 001 to CIO 099, C IO 101 to CIO 199 (C P1W Expansion I/O Unit’ s I/O Area)  Operand Speci ...

  • Omron CP1E-E@@D@-@ - page 389

    2-353 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Basic I/O Unit Instructions 2 IORF Units Refreshed b y IORF(097) Note CP1E CPU Unit built-in I/O area cannot be refreshed with IORF(097). CP1E CPU Unit built-in I/O area can be refre shed with immediate refreshi ng specifications (!). Function Precaution • IORF(097) can be use ...

  • Omron CP1E-E@@D@-@ - page 390

    2 Instructions 2-354 CP1E CPU Unit Instructions Reference Manual(W483) SDEC Applicable Pr ogram Areas Operands Di: Digit designator  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function 7-SEGMENT DECODER SDEC @SDEC 078 Conv er ts the hexadecimal contents of the desig- nated digit(s) into 8-bit, 7-segment display ...

  • Omron CP1E-E@@D@-@ - page 391

    2-355 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Basic I/O Unit Instructions 2 SDEC Function Precaution • If more than one digit is specified f o r conv ersi on in Di, digits are conv er ted in order tow ard the most- significant digit. Digit 0 is the next digit after digit 3. • Results are stored in D in order from the sp ...

  • Omron CP1E-E@@D@-@ - page 392

    2 Instructions 2-356 CP1E CPU Unit Instructions Reference Manual(W483)  7-segment Data The f ollowing table sho ws the data co nv ersions from a he xade cimal digit (4 bits) to 7-segment code (8 bits). Original data Conve rted code (segments) Display Original data Digit Bits – g f e d c b a Hex 0 000000111111 3 F 1 000100000110 0 6 2 001001011 ...

  • Omron CP1E-E@@D@-@ - page 393

    2-357 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Basic I/O Unit Instructions 2 DSW DSW Applicable Pr ogram Areas Operands I: Input W ord (Data Line D0 to D3 Inputs) Specify the input word a llocated to the Input Unit and connect the digital s witch’ s D0 to D3 data lines to the Input Unit as shown in the follo wing diagr am. ...

  • Omron CP1E-E@@D@-@ - page 394

    2 Instructions 2-358 CP1E CPU Unit Instructions Reference Manual(W483) D: First Result W ord Specifies the leading word address where the e xter nal digital switch’ s set values will be stored. C1: Number of Digits Specifies the number of digits that will be read from the e xter nal digital switch. Set C1 to 0000 he x to read 4 digits or 0001 he ...

  • Omron CP1E-E@@D@-@ - page 395

    2-359 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Basic I/O Unit Instructions 2 DSW  External Connections Connect the digital s witch or thumbwheel switch to In put Unit contacts 0 to 7 and Output Unit contacts 0 to 4, as shown i n the f ollowing diagr am. The f ollowing e xample illustrates connections f or an A7B Thum- bwh ...

  • Omron CP1E-E@@D@-@ - page 396

    2 Instructions 2-360 CP1E CPU Unit Instructions Reference Manual(W483) Precaution • Do not read or write the system word (C2) from an y other instruction. DSW(210) will not operate cor- rectly if the system word is accessed by anothe r instruction. The system word is not initialized b y DSW(210) in the first cycle when progr am e x ecution star t ...

  • Omron CP1E-E@@D@-@ - page 397

    2-361 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Basic I/O Unit Instructions 2 MTR MTR Applicable Pr ogram Areas Operands I: Input W ord Specify the input word allocated to the Input Unit and co nnect the 8 input signal lines to the Input Unit as shown in the f ollowing diag ram. O: Output W ord (Selection Signal Outputs) Spec ...

  • Omron CP1E-E@@D@-@ - page 398

    2 Instructions 2-362 CP1E CPU Unit Instructions Reference Manual(W483) D: First Register W ord Specifies the leading word address of the 4 words that co ntain the data from the 8 × 8 matrix. C: System W ord Specifies a work word used by the instruction. This wo rd cannot be used in any other application.  Operand Specifications Area W ord ad dr ...

  • Omron CP1E-E@@D@-@ - page 399

    2-363 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Basic I/O Unit Instructions 2 MTR Flag s Function MTR(213) outputs the selection signals to bits 00 to 07 of O , reads the data in or der from bits 00 to 07 of I, and stores the 64 bits of data in th e 4 wo rds D thro ugh D+3. MTR(213) rea ds the status of the 64- bit matrix e v ...

  • Omron CP1E-E@@D@-@ - page 400

    2 Instructions 2-364 CP1E CPU Unit Instructions Reference Manual(W483) Precaution • Do not read or write the system word (C) from any other instruction. MTR (213) will not operate cor- rectly if the system word is accessed by anothe r instruction. The system word is not initialized b y MTR(213) in the first cycle when program e xecutio n star ts. ...

  • Omron CP1E-E@@D@-@ - page 401

    2-365 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Basic I/O Unit Instructions 2 7SEG 7SEG Applicable Pr ogram Areas Operands S: Source W or d Specify the first source word containing the data that will be conv er ted to 7-segment display data. O: Output W ord (Data and Latch Outputs) Specify the output word allo cated to the Ou ...

  • Omron CP1E-E@@D@-@ - page 402

    2 Instructions 2-366 CP1E CPU Unit Instructions Reference Manual(W483) • Conv er ting 8 digits C: Control Data The value of C indicates the n umber of digits of source data and the logic f or the Input and Output Units, as sho wn in the f ollowing tab le. (The logic re f ers to the transistor output’ s NPN or PNP logic.) D: System W ord Specifi ...

  • Omron CP1E-E@@D@-@ - page 403

    2-367 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Basic I/O Unit Instructions 2 7SEG  External Connections Connect the 7-segment displa y to the Output Unit as shown in the f ollowing diag ram. This e xample shows an 8-digit displa y . With a 4-digit displa y , the da ta outputs (D0 to D3) would be connected to out- puts 0 t ...

  • Omron CP1E-E@@D@-@ - page 404

    2 Instructions 2-368 CP1E CPU Unit Instructions Reference Manual(W483) Precaution • Do not read or write the system word (D) from any other instruction. 7SEG(214) will not operate cor- rectly if the system word is accessed by anothe r instruction. The system word is not initialized b y 7SEG(214) in the first cycle when progra m e x ecution star t ...

  • Omron CP1E-E@@D@-@ - page 405

    2-369 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Serial Communication Instructions 2 TXD Serial Comm unication Instructions TXD Applicable Pr ogram Areas Operands C: Control w ord  Operand Specifications Instruction Mnemonic V ariations Function code Function TRANSMIT TXD @TXD 236 Outputs the specified number of bytes of da ...

  • Omron CP1E-E@@D@-@ - page 406

    2 Instructions 2-370 CP1E CPU Unit Instructions Reference Manual(W483) Flags Related A uxiliar y Area W ords and Bits  CPU Unit’ s Bu ilt-in RS-232C P or t  Serial Option Board P or t Related PLC Setup Settings Function • TXD(236) reads N byte s of data from words S to S+(N ÷ 2)-1 and outputs the r aw data in no- protocol mode from the C ...

  • Omron CP1E-E@@D@-@ - page 407

    2-371 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Serial Communication Instructions 2 TXD • Up to 259 bytes can be sent, including the send data (N = 256 b ytes max.), the star t code, and the end code . • Specify the size of the send data, not including the star t code and end code, in N.  Star t code / end code setting ...

  • Omron CP1E-E@@D@-@ - page 408

    2 Instructions 2-372 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram  Sending Data to a Code Reader This e xample shows ho w to send data to the V530-R150 V3 2D Code Reader as an example of commu- nicating with an e x ternal device. Hard ware Configuration In this e xample, the e xter nal device is connected to the RS-232C por ...

  • Omron CP1E-E@@D@-@ - page 409

    2-373 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Serial Communication Instructions 2 TXD Pr ogramming Example If CIO 0.01 turns ON while the RS-232C P or t Send Ready F lag (A392.05) is ON, three b ytes of data star ting from the upper b yte of D10 are sent without con v ersion to the Code Reader connected to the CPU Unit’ s ...

  • Omron CP1E-E@@D@-@ - page 410

    2 Instructions 2-374 CP1E CPU Unit Instructions Reference Manual(W483) RXD Applicable Pr ogram Areas Operands C: Control W ord  Operand Specifications Flags Instruction Mnemonic V ariations Functio n code Function RECEIVE RXD @RXD 235 Reads the specified number of bytes of data from the CPU Unit’ s built-in RS-232C por t or the Serial Option B ...

  • Omron CP1E-E@@D@-@ - page 411

    2-375 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Serial Communication Instructions 2 RXD Related A uxiliar y Area W ords and Bits  A uxiliary Area Flags for CPU Unit’ s RS-232C P or t  A uxiliary Area Flags for Serial Option Boar d P or t Related PLC Setup Settings Name Address Contents RS-232C P or t Reception Complet ...

  • Omron CP1E-E@@D@-@ - page 412

    2 Instructions 2-376 CP1E CPU Unit Instructions Reference Manual(W483) Function • RXD(235) reads data that has been receiv ed in no-pro tocol mode at the CPU Unit’ s built-in RS-232C por t or the Serial O ption Board por t (the por t is specified wit h bits 8 to 11 of C) and stores N bytes of data in words D to D+(N ÷ 2)-1. If N bytes of data ...

  • Omron CP1E-E@@D@-@ - page 413

    2-377 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Serial Communication Instructions 2 RXD  Start Code/End Code Se ttings and Receive Data Hint • When RXD(235) is used to read data that was receiv ed at one of the Serial Option Board’ s por ts , the por t’ s reception buff er is cleared after RXD(23 5) is ex ecuted. Con ...

  • Omron CP1E-E@@D@-@ - page 414

    2 Instructions 2-378 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram  Receiving data This e xample shows how to receiv e data from th e V530-R150V3 2D Code Read er as an example of communicating with an e xter nal de vice. Hard ware Configuration In this e xample, the e xter nal device is connected to the RS-232C por t bu ilt i ...

  • Omron CP1E-E@@D@-@ - page 415

    2-379 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Serial Communication Instructions 2 RXD Pr ogramming Example If CIO 0.02 turns ON while the RS-2 32C P or t Send Ready Flag (A392.05) is ON, the number of bytes of reading results specified in the RS-23 2C P or t Reception Counte r (A393) are read from the Code Reader connected ...

  • Omron CP1E-E@@D@-@ - page 416

    2 Instructions 2-380 CP1E CPU Unit Instructions Reference Manual(W483) Cloc k Instructions CADD/CSUB Applicable Pr ogram Areas Operands Instruction Mnemonic V ariations Functio n code Function CALEND AR ADD CADD @CADD 730 Adds time to the calendar data in the specified words. CALENDA R SUBTRACT CSUB @CSUB 731 Subtracts time from the calendar data i ...

  • Omron CP1E-E@@D@-@ - page 417

    2-381 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Clock Instructions 2 CADD/CSUB  CADD C through C+2: Calendar Data T and T+1: Time Data R through R+2: Result Data 15 8 0 7 C 15 8 0 7 C+1 15 8 0 7 C+2 Seconds: 00 to 59 (BCD) Min utes: 00 to 59 (BCD) Hour: 00 to 23 (BCD) Month: 01 to 12 (BCD) Y ear: 00 to 99 (BCD) Day: 01 to ...

  • Omron CP1E-E@@D@-@ - page 418

    2 Instructions 2-382 CP1E CPU Unit Instructions Reference Manual(W483)  CSUB C through C+2: Calendar Data T and T+1: Time Data R through R+2: Result Data 15 8 0 7 C 15 8 0 7 C+1 15 8 0 7 C+2 Minutes: 00 to 59 (BCD) Seconds: 00 to 59 (BCD) Day: 01 to 31 (BCD) Hour: 00 to 23 (BCD) Y ear: 00 to 99 (BCD) Month: 01 to 12 (BCD) 15 8 0 7 T 15 0 T+1 Sec ...

  • Omron CP1E-E@@D@-@ - page 419

    2-383 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Clock Instructions 2 CADD/CSUB  Operand Specifications Flag s Function  CADD CADD(730) adds the calenda r data (words C through C+2) to the time data (w ords T and T+1) and outputs the resultin g calendar data to R through R+2.  CSUB CSUB(731) subtracts the time data (w ...

  • Omron CP1E-E@@D@-@ - page 420

    2 Instructions 2-384 CP1E CPU Unit Instructions Reference Manual(W483) Sample pr ogram  CADD When CIO 0.00 tur ns ON in the f ollowing e xample, the calendar data in D1 00 through D102 (y ear , month, da y , hour , minutes , seconds) is added to the time data in D200 and D201 (hou rs, mi nutes, sec- onds) and the re sult is output to D300 throug ...

  • Omron CP1E-E@@D@-@ - page 421

    2-385 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Clock Instructions 2 D A TE DA T E Applicable Pr ogram Areas Operands S through S+3: Ne w Clock Setting Note S through S+3 must be in the same data area.  Operand Specifications Flag s Instruction Mnemonic V ariations Function code Function CLOCK ADJUSTMENT DA TE @DA TE 735 C ...

  • Omron CP1E-E@@D@-@ - page 422

    2 Instructions 2-386 CP1E CPU Unit Instructions Reference Manual(W483) Related A uxiliar y Area W ords and Bits Function D A TE(735) changes th e inter nal clock setting according to the clock data in the four source words. The new inter- nal clock setting is immediately reflected in the Calendar/Cloc k Area (A351 to A354). Hint The internal clock ...

  • Omron CP1E-E@@D@-@ - page 423

    2-387 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Failure Diagnosis Instructions 2 F AL F ailure Diagnosis Instructions FA L Applicable Pr ogram Areas Operands  Generating or Clearing User -defined Non-fatal Error s Note The v alue of operand N must be different from the content of A529 (the system-generated F AL/F ALS numbe ...

  • Omron CP1E-E@@D@-@ - page 424

    2 Instructions 2-388 CP1E CPU Unit Instructions Reference Manual(W483) Flags Related A uxiliar y Area W ords and Bits  A uxiliary Area W ords/Flags f o r User-defined Err ors Only  A uxiliary Area W ords/Flags f or System Errors Onl y  A uxiliary Area W ords/Flags f or bot h User-defined and System Err ors Clearing Non-fatal Err ors withou ...

  • Omron CP1E-E@@D@-@ - page 425

    2-389 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Failure Diagnosis Instructions 2 F AL Function  Generating Non-fatal User -defined Error s The f ollowing tab le shows the error codes and F AL Er ror Flags f or F AL(006). When F AL(006) is ex ecuted wit h N set to an F AL number (&1 to &51 1) that is not equal to th ...

  • Omron CP1E-E@@D@-@ - page 426

    2 Instructions 2-390 CP1E CPU Unit Instructions Reference Manual(W483) 1. The specified error code will be written to A400. 2. The error code and the time that the error occurred will be written to the Error Log Area (A100 through A199) . 3. The appropriate Auxiliary Area Flags are set based on the error code and error details. 4. The ERR Indicator ...

  • Omron CP1E-E@@D@-@ - page 427

    2-391 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Failure Diagnosis Instructions 2 F AL Note Even if PLC Setup w ord 129 bit 15 is set to 1 (Do not record F AL Errors in Error Log.), the f ollowing errors will be recorded: • F atal errors generated by F ALS(007) • Non-f atal errors from the system • F atal errors from the ...

  • Omron CP1E-E@@D@-@ - page 428

    2 Instructions 2-392 CP1E CPU Unit Instructions Reference Manual(W483)  Clearing a P articular Non-fatal Error When CIO 0.01 is ON in the f ollowing example , F AL(006) will clear the non-f atal error with F AL number 31, turn OFF the corres ponding Executed F AL Number Flag (A361.15), and tu rn OFF the F AL Error Flag (A402.15).  Clearing Al ...

  • Omron CP1E-E@@D@-@ - page 429

    2-393 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Failure Diagnosis Instructions 2 F ALS FA L S Applicable Pr ogram Areas Operands  Generating User-defined F atal Error s Note The v alue of operand N must be different from the content of A529 (the system-generated F AL/F ALS number).  Generating F atal Error s from the Sy ...

  • Omron CP1E-E@@D@-@ - page 430

    2 Instructions 2-394 CP1E CPU Unit Instructions Reference Manual(W483) Related A uxiliar y Area W ords and Bits  A uxiliary Area W ords/Flags f o r User-defined Err ors Only  A uxiliary Area W ords/Flags f or System Errors Onl y  A uxiliary Area W ords/Flags f or bot h User-defined and System Err ors Function  Generating Fatal User -def ...

  • Omron CP1E-E@@D@-@ - page 431

    2-395 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Failure Diagnosis Instructions 2 F ALS 4 When a user-defined fatal error is registe red, the I/O memor y and output status from output u nits will be as indicated below .  Generating Non-fatal System Err ors When F ALS(007) is e x ecuted wit h N set to an F AL number (1 to 51 ...

  • Omron CP1E-E@@D@-@ - page 432

    2 Instructions 2-396 CP1E CPU Unit Instructions Reference Manual(W483) The f ollowing table sho ws how to specify er ror codes and error details in S and S+1.  Displaying Messa ges with Fatal User -defined Error s • If S is a word address , the ASCII message beginning at S will be displa yed at the Progr amming De vice when F ALS(007) is e x e ...

  • Omron CP1E-E@@D@-@ - page 433

    2-397 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Failure Diagnosis Instructions 2 F ALS Sample pr ogram  Generating a User -defined Error When CIO 0.00 is ON in the follo wing ex ample, F ALS(007) will generate a fatal error with F AL number 31 and e xecute the f ollowing processes. 1. The F ALS Error Flag (A401.06) will be ...

  • Omron CP1E-E@@D@-@ - page 434

    2 Instructions 2-398 CP1E CPU Unit Instructions Reference Manual(W483) Other Instructions STC/CLC Applicable Pr ogram Areas Flags Function  STC When the e x ecution condition is ON, STC(040) turns ON the Carry Flag (CY). Although STC(040) turns the Carr y Flag ON, the flag will be tur ned ON/OFF by the e x ecution of subsequent instructions whic ...

  • Omron CP1E-E@@D@-@ - page 435

    2-399 2 Instructions CP1E CPU Unit Instructions Reference Manual(W483) Other Instructions 2 WDT WDT Applicable Pr ogram Areas Operands T : Timer setting Specifies the watchdog timer setting between 0000 and 0064 he xadecimal or between &0000 and &0100 decimal.  Operand Specifications Flag s Related PLC Setup Settings  CX-Programmer se ...

  • Omron CP1E-E@@D@-@ - page 436

    2 Instructions 2-400 CP1E CPU Unit Instructions Reference Manual(W483)  PLC Setup settings Note • The default value f or the maximum cycle time is 1,00 0 ms, although it can be set anywhere from 10 to 1,000 ms in 10-ms units. • WDT(094) can be used more than once in a cycle. When WDT(094) is e x ecuted more than once the cycle time extension ...

  • Omron CP1E-E@@D@-@ - page 437

    3-1 CP1E CPU Unit Instructions Reference Manual(W483) 3 This section provides the e x ecution times for all instructions used with a CP1E CPU Unit. 3-1 CP1E CPU Unit Instruction Execution Times and Number of Steps . . . . . 3-2 Instruction Ex ecution Times and Number of Steps ...

  • Omron CP1E-E@@D@-@ - page 438

    3 Instruction Exec ut ion Times and Number of Steps 3-2 CP1E CPU Unit Instructions Reference Manual(W483) 3-1 CP1E CPU Unit Instruction Ex ecution Times and Number of Steps The f ollowing tab le lists the e xecution times f or all instruct ions that are suppor ted by the CPU Units. The total e xecution time of instru ctions within one whole use r p ...

  • Omron CP1E-E@@D@-@ - page 439

    3-3 3 Instruction Execution Times and Number of Steps CP1E CPU Unit Instructions Reference Manual(W483) 3-1 CP1E CPU Unit Instruction Execution Times and Number of 3 Sequence Input Instructions Instru ction Mnemonic FUN No. Length (steps) ON execution time ( µ s) Condit ions LOAD LD --- 1 1.19 --- !LD --- 2 1 0.26 --- LOAD NO T LD NO T --- 1 1.19 ...

  • Omron CP1E-E@@D@-@ - page 440

    3 Instruction Exec ut ion Times and Number of Steps 3-4 CP1E CPU Unit Instructions Reference Manual(W483) Sequence Contr ol Instructions Instruction Mnemonic FUN No. Length (steps ) ON execution time ( µ s) Condition s END END 001 1 4.6 --- NO OPERA TION NOP 000 1 1.2 --- INTERLOCK IL 002 1 4.3 --- INTERLOCK CLEAR ILC 003 1 4.3 --- MUL TI-INTERLOC ...

  • Omron CP1E-E@@D@-@ - page 441

    3-5 3 Instruction Execution Times and Number of Steps CP1E CPU Unit Instructions Reference Manual(W483) 3-1 CP1E CPU Unit Instruction Execution Times and Number of 3 Comparison Instructions Instru ction Mnemonic FUN No. Length (steps) ON execution time ( µ s) Conditions Input Comparison Instructions (unsigned) LD ,AND ,OR+= 300 4 9.3 --- LD ,AND , ...

  • Omron CP1E-E@@D@-@ - page 442

    3 Instruction Exec ut ion Times and Number of Steps 3-6 CP1E CPU Unit Instructions Reference Manual(W483) Data Mo vement Instructions Instruction Mnemonic FUN No. Length (steps) ON executi on time ( µ s) Conditions MO VE MOV 021 3 8.0 --- !MO V 021 7 57.7 --- DOUBLE MO VE MO VL 498 3 8.9 --- MO VE NO T MVN 022 3 13.7 --- MO VE BIT MO VB 0 82 4 21. ...

  • Omron CP1E-E@@D@-@ - page 443

    3-7 3 Instruction Execution Times and Number of Steps CP1E CPU Unit Instructions Reference Manual(W483) 3-1 CP1E CPU Unit Instruction Execution Times and Number of 3 Increment/Decrement Instructions Instru ction Mnemonic FUN No. Length (steps) ON execution time ( µ s) Condit ions INCREMENT BINAR Y ++ 590 2 12.3 --- DOUBLE INCREMENT BINAR Y ++L 591 ...

  • Omron CP1E-E@@D@-@ - page 444

    3 Instruction Exec ut ion Times and Number of Steps 3-8 CP1E CPU Unit Instructions Reference Manual(W483) Con version Instructions Instruction Mnemonic FUN No. Length (steps ) ON executi on time ( µ s) Condit ions BCD T O BINAR Y BIN 023 3 15.1 - -- DOUBLE BCD T O DOUBLE BINAR Y BINL 058 3 16.7 --- BINAR Y TO BCD BCD 024 3 15.1 --- DOUBLE BINAR Y ...

  • Omron CP1E-E@@D@-@ - page 445

    3-9 3 Instruction Execution Times and Number of Steps CP1E CPU Unit Instructions Reference Manual(W483) 3-1 CP1E CPU Unit Instruction Execution Times and Number of 3 Floating-point Math Instructions Instru ction Mnemonic FUN No. Length (steps) ON execution time ( µ s) Conditions FLOA TING T O 16-BIT FIX 450 3 15.9 --- FLOA TING T O 32-BIT FIXL 451 ...

  • Omron CP1E-E@@D@-@ - page 446

    3 Instruction Exec ut ion Times and Number of Steps 3-10 CP1E CPU Unit Instructions Reference Manual(W483) Subr outine Instructions Instruction Mnemonic FUN No. Length (steps) ON execution time ( µ s) Conditions SUBROUTINE CALL SBS 091 2 6.6 --- SUBROUTINE E NTR Y SBN 092 2 2.6 --- SUBROUTINE RETURN RET 093 1 3.1 --- Interrupt Contr ol Instruction ...

  • Omron CP1E-E@@D@-@ - page 447

    3-11 3 Instruction Execution Times and Number of Steps CP1E CPU Unit Instructions Reference Manual(W483) 3-1 CP1E CPU Unit Instruction Execution Times and Number of 3 ACCELE RA TION CONTROL ACC 888 4 75.6 Continuou s mode 82.8 Independent mode ORIGIN SEAR CH ORG 889 3 52.2 Origin search 126.8 Origin return PULSE WITH V ARIABLE DUTY FA C T O R PWM 8 ...

  • Omron CP1E-E@@D@-@ - page 448

    3 Instruction Exec ut ion Times and Number of Steps 3-12 CP1E CPU Unit Instructions Reference Manual(W483) F ailure Diagnosis Instructions Instruction Mnemonic FUN No. Length (steps) ON execution time ( µ s) Conditions F AILURE ALARM F AL 006 3 55.6 Recording errors 79.6 Deleting errors (in order of priority) 61.6 Deleting errors (all errors) 60.0 ...

  • Omron CP1E-E@@D@-@ - page 449

    4-1 CP1E CPU Unit Instructions Reference Manual(W483) 4 This section describes how to mo nitor and calculate the cycle time of a CP1E CPU Unit that can be used in the pr ograms . 4-1 Monitoring the C ycle Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 4-1-1 Monitoring the Cycle Time . . . . . . . . . . . . . . ...

  • Omron CP1E-E@@D@-@ - page 450

    4 Monitoring and Computing the Cycle Time 4-2 CP1E CPU Unit Instructions Reference Manual(W483) 4-1 Monitoring the Cyc le Time The av erage, maximum, and minim um cycle times ca n be monit ored when the CX-Programmer is con- nected online to a CPU Unit. While connected online to the PLC, the a v erage cycle time is display ed in the status bar when ...

  • Omron CP1E-E@@D@-@ - page 451

    4-3 4 Monitoring and Computing the Cycle Time CP1E CPU Unit Instructions Reference Manual(W483) 4-2 Computing th e Cycle Time 4 4-2-1 CPU Unit Operation Flowchar t 4-2 Computing the Cyc le Time The CPU Unit processes data in repeating cycles from the ov erseeing processing up to peripheral ser vicing as shown in the f ollowing diagra m. 4-2-1 CPU U ...

  • Omron CP1E-E@@D@-@ - page 452

    4 Monitoring and Computing the Cycle Time 4-4 CP1E CPU Unit Instructions Reference Manual(W483) The cycle time depends on the follo wing conditions. • T ype and number of instr uctions in the us er program (cyclic tasks and all interr upt tasks f or which the e x ecution conditions hav e been satisfied) • T ype and number of CP-seri es Expansio ...

  • Omron CP1E-E@@D@-@ - page 453

    4-5 4 Monitoring and Computing the Cycle Time CP1E CPU Unit Instructions Reference Manual(W483) 4-2 Computing th e Cycle Time 4 4-2-3 I/O Refresh Times for PLC Units (5) P eripheral Servicing  I/O Refresh Times f or Built-in Analog I/O (NA-type CPU Unit only) Note No matter whether use an alog I/O function or not, the I/O refresh time is the sam ...

  • Omron CP1E-E@@D@-@ - page 454

    4 Monitoring and Computing the Cycle Time 4-6 CP1E CPU Unit Instructions Reference Manual(W483) The f ollowing e xample shows th e method used to calculate the cycle time when Expansion I/O Units are connected to a CP1E CPU Unit.  Conditions  Calculation Example When online editing is e x ecuted to change the progr am from the CX-Programmer w ...

  • Omron CP1E-E@@D@-@ - page 455

    A-1 pp CP1E CPU Unit Instructions Reference Manual(W483) App Alphabetical List of Instructions by Mnemonic . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 Appendices ...

  • Omron CP1E-E@@D@-@ - page 456

    Appendices A-2 CP1E CPU Unit Instructions Reference Manual(W483) Alphabetical List of Instructions b y Mnemonic A Mne- monic Instru ction FUN No. Upward differen- tiatio n Downward differentia- tion Immediate refreshing specifica- tion Pag e ACC AC C E L ER - AT I O N CONTROL 888 @A CC --- --- 2-331 AND AND --- @AND %AND !AND 2-9 AND LD AND LOAD -- ...

  • Omron CP1E-E@@D@-@ - page 457

    A-3 Appendices CP1E CPU Unit Instructions Reference Manual(W483) Alphabetical List of Instructions by Mnemonic App B C AND>= SL AND DBL SIGNED GREA TER THAN OR EQU AL 328 --- --- --- 2-88 AND> DT AND TIME GREA TER THAN 345 --- --- --- 2-91 AND>F AND FLOA TING GREA TER THAN 333 --- --- - -- 2-241 AND>L AND DOU- BLE GREA TER THAN 321 --- ...

  • Omron CP1E-E@@D@-@ - page 458

    Appendices A-4 CP1E CPU Unit Instructions Reference Manual(W483) D E F H I J K L Mne- monic Instru ction FUN No. Upward differen- tiation Downward differ enti a- tion Immediate refreshing specifica- tion Pag e DA T E C L O C K ADJUST- MENT 735 @D A TE --- --- 2-385 DI DISABLE INTER- RU P T S 693 @DI --- --- 2-306 DIFD DIFFEREN- TIA TE DOWN 014 --- ...

  • Omron CP1E-E@@D@-@ - page 459

    A-5 Appendices CP1E CPU Unit Instructions Reference Manual(W483) Alphabetical List of Instructions by Mnemonic App LD NO T LOAD NO T --- --- --- !LD NOT 2-7 LD< LOAD LESS THAN 310 --- --- --- 2-88 LD<= LOAD LESS THAN OR EQU AL 315 --- --- --- 2-88 LD<= DT LOAD D A TE LESS THAN OR EQU A L 344 --- --- --- 2-91 LD<=F LOAD FLOA TING LESS TH ...

  • Omron CP1E-E@@D@-@ - page 460

    Appendices A-6 CP1E CPU Unit Instructions Reference Manual(W483) M N O Mne- monic Instru ction FUN No. Upward differen- tiation Downward differ enti a- tion Immediate refreshing specifica- tion Pag e MILC MUL TI- INTER- LOCK CLEAR 519 --- -- - --- 2-44 MILH MUL TI- INTER- LOCK DIF- FERENTIA T IONHOLD 517 --- -- - --- 2-44 MILR MUL TI- INTER- LOCK D ...

  • Omron CP1E-E@@D@-@ - page 461

    A-7 Appendices CP1E CPU Unit Instructions Reference Manual(W483) Alphabetical List of Instructions by Mnemonic App P R OR= OR EQU AL 300 --- --- - -- 2-88 OR=DT OR DA TE EQU AL 341 --- --- --- 2-91 OR=F OR FLOA TING EQU AL 329 --- --- --- 2-241 OR=L OR DOUBLE EQU AL 301 --- --- --- 2-88 OR=S OR SIGNED EQU AL 302 --- --- --- 2-88 OR=SL OR DOU- BLE S ...

  • Omron CP1E-E@@D@-@ - page 462

    Appendices A-8 CP1E CPU Unit Instructions Reference Manual(W483) S T U W X Mne- monic Instru ction FUN No. Upward differen- tiation Downward differ enti a- tion Immediate refreshing specifica- tion Pag e SBN SUBROU- TINE ENTR Y 092 --- -- - --- 2-295 SBS SUBROU- TINE CALL 091 @SBS --- --- 2-290 SCL SCALING 194 @SCL --- --- 2-276 SCL2 SCALING 2 486 ...

  • Omron CP1E-E@@D@-@ - page 463

    A-9 Appendices CP1E CPU Unit Instructions Reference Manual(W483) Alphabetical List of Instructions by Mnemonic App Z Symbol Mne- monic Instruction FUN No. Upward differen- tiatio n Downward differentia- tion Immediate refreshing specifica- tion Pag e ZCP AREA RANGE COM- PA R E 088 --- --- --- 2-105 ZCPL DOUBLE AREA RANGE- COMP ARE 116 --- --- --- 2 ...

  • Omron CP1E-E@@D@-@ - page 464

    Appendices A-10 CP1E CPU Unit Instructions Reference Manual(W483) ASCII Code T ab le *BL DOUBLE BCD MUL TI- PL Y 425 @ *B L --- --- 2-179 *F FLOA TING- POINT MUL TIPL Y 456 @ *F --- --- 2-237 *L DOUBLE SIGNED BINAR Y- MUL TIPL Y 421 @ *L --- --- 2-177 / SIGNED BINAR Y DIVIDE 430 @ / --- --- 2-181 /B BCD DIVIDE 434 @ /B --- --- 2-183 /BL DOUBLE BCD ...

  • Omron CP1E-E@@D@-@ - page 465

    Revision-1 Re vision Histor y A manual r e vision code a ppears a s a suffix t o the c atalog number o n the fron t cover of the manual. Revi sion code Date Rev ised content 01 March 2009 Original p roducti on 02 June 200 9 Errors we re corrected. 03 Ja nuary 2010 In formatio n added on E10/14, N 14/60 and NA20 CPU Units. Cat. N o . W483-E 1-03 Rev ...

  • Omron CP1E-E@@D@-@ - page 466

    Revision-2 ...

  • Omron CP1E-E@@D@-@ - page 467

    Authorized Distrib utor: In the interest of product improvement, specifications are subject to change without notice. Cat. No. W483-E1-03 0110 © OMRON Corporation 2009 All Rights Reserved. OMRON Corporation Industrial Automation Company OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843 ...

Manufacturer Omron Category Computer Hardware

Documents that we receive from a manufacturer of a Omron CP1E-E@@D@-@ can be divided into several groups. They are, among others:
- Omron technical drawings
- CP1E-E@@D@-@ manuals
- Omron product data sheets
- information booklets
- or energy labels Omron CP1E-E@@D@-@
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omron CP1E-E@@D@-@.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omron CP1E-E@@D@-@, service manual, brief instructions and user manuals Omron CP1E-E@@D@-@. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omron CP1E-E@@D@-@.

Similar manuals

A complete manual for the device Omron CP1E-E@@D@-@, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omron CP1E-E@@D@-@ by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omron CP1E-E@@D@-@.

A complete Omron manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omron CP1E-E@@D@-@ - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omron CP1E-E@@D@-@, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omron CP1E-E@@D@-@, that we can find in the current document
3. Tips how to use the basic functions of the device Omron CP1E-E@@D@-@ - which should help us in our first steps of using Omron CP1E-E@@D@-@
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omron CP1E-E@@D@-@
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omron CP1E-E@@D@-@ in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omron CP1E-E@@D@-@?

Use the form below

If you did not solve your problem by using a manual Omron CP1E-E@@D@-@, ask a question using the form below. If a user had a similar problem with Omron CP1E-E@@D@-@ it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)