    www .schischek.com Description size S The new RedMax actuators are a revolution for safety , fire and shut-off dampers, V A V systems, ball valves, throttle valves and other motorized applications for HV AC systems, in chemical, pharmaceutical, industrial and Offshore-/Onshore plants, for use in EEx-areas zone 2 (gas) and zone 22 (dust). Highest pr ...

  • RedMax -5.10-BF - page 2

    www .schischek.com T echnical data RedMax-5.10-BF RedMax-15-BF Accessories or special solutions - size S Schischek GmbH Germany D-90579 Langenzenn, Mühlsteig 45, Gewerbegebiet V , T el. ++49 (0)9101-90810, Fax ++49 (0)9101-908177, Email ExMax@schischek.de RedMax-5.10-BF RedMax-15-BF Special makes RedMax-..-V A/-CT EXPLOSIONPROOF Certification PTP ...

  • RedMax -5.10-BF - page 3

    www .schischek.com RedMax actuators are equipped with a universal supply unit working at a voltage range from 24 to 230 VAC/DC . The supply unit is self adjustable to the connected voltage! The safety operation of the spring return function works if the supply voltage is cut. For electrical connection inside hazardous areas an t erminal box, certif ...

  • RedMax -5.10-BF - page 4

    www .schischek.com Mounting instructions and important information for operation and installation D.EM-03.08-S-en-BF 2006-06-14 Schischek GmbH Germany D-90579 Langenzenn, Mühlsteig 45, Gewerbegebiet V , T el. ++49 (0)9101-90810, Fax ++49 (0)9101-908177, Email ExMax@schischek.de RedMax-5.10-BF RedMax-15-BF Special makes RedMax-..-V A/-CT EXPLOSIONP ...

  • RedMax -5.10-BF - page 5

    Power supply design Rated current in acc. with motor running time V oltage Current 3/7,5s 15s 30s 60s 120s 230 V I rated 0,5 A 0,3 A 0,15 A 0,10 A 0,10 A 120 V I rated 0,75 A 0,4 A 0,3 A 0,25 A 0,25 A 48 V I rated 2,0 A 0,5 A 0,3 A 0,2 A 0,2 A 24 V I rated 4,7 A 1,45 A 0,52 A 0,4 A 0,4 A The design of the on-site supply , depends on the selected mo ...

  • RedMax -5.10-BF - page 6

    ExMax-...-F , ExMax-...-SF , RedMax-...-F , RedMax-...-SF PA PA ExMax-...-BF , RedMax-...-BF PA PA PA U 0 = 10,6 V I 0 = 1 1 mA P 0 = 30 mW C i = 0 L i = 0 IIC IIB IIA C 0 830 nF 3,7µF 4,5 µF L 0 2 mH 5 mH 10 mH Schischek GmbH Germany D-90579 Langenzenn, Mühlsteig 45, Gewerbegebiet V , T el. ++49 (0)9101-90810, Fax ++49 (0)9101-908177, Email ExM ...

  • RedMax -5.10-BF - page 7

    ExMax-...-Y .., RedMax-...-Y .. PA PA PA PA 3-sec. mode, 3-pos-operation, heating by low ambient temperatures Schischek GmbH Germany D-90579 Langenzenn, Mühlsteig 45, Gewerbegebiet V , T el. ++49 (0)9101-90810, Fax ++49 (0)9101-908177, Email ExMax@schischek.de ExMax-.. and RedMax-.. extra information EL - size S Self adjustment: T o adjust the sig ...

  • RedMax -5.10-BF - page 8

    Error/Symptom Reason Solution M.EZ-01.05-S-en-Zusatzinfo EL 2006-04-05 Schischek GmbH Germany D-90579 Langenzenn, Mühlsteig 45, Gewerbegebiet V , T el. ++49 (0)9101-90810, Fax ++49 (0)9101-908177, Email ExMax@schischek.de Actuator does not work LED lights red l The actuator is operated by a too high ambient temperature and the internal temperature ...

  • RedMax -5.10-BF - page 9

    www .schischek.com Dimension size S Specification The "ME"-data sheet contains additional information for ExMax and RedMax actuators of the size "S", for the optimization and simplification in regard to planning, installation and initial start up. It provides influences of external factors in reference to the safe initiation of ...

  • RedMax -5.10-BF - page 10

    www .schischek.com Specification ExMax and RedMax actuators size S are equipped with a 12 x 12 mm (double square) shaft connection. The form-fitting shaft connection is the securest connection between damper shaft and actuator because slipping or slipping through is avoided compared to the force-fit clamp-connection. The actuator will be connected ...

  • RedMax -5.10-BF - page 11

    www .schischek.com Specification ExMax and RedMax actuators of the size S are equiped with a 12x12 mm (double square) form-fitting shaft connection. For mountin g to butterfly valves or ball valve a special mounting bracket in acc. with DIN EN ISIO 521 1 is required. Since this standard provides only certain basic conditions there can be substantia ...

  • RedMax -5.10-BF - page 12

    www .schischek.com M.MZ-01.01-S-en-Zusatzinfo ME Specification Specification Schischek GmbH Germany D-90579 Langenzenn, Mühlsteig 45, Gewerbegebiet V , T el. ++49 (0)9101-90810, Fax ++49 (0)9101-908177, Email ExMax@schischek.de ExMax-.. and RedMax-.. extra information ME - size S EXPLOSIONPROOF Mounting of ExSwitch (RedSwitch) accessory to the act ...

Manufacturer RedMax Category Automobile Parts

Documents that we receive from a manufacturer of a RedMax -5.10-BF can be divided into several groups. They are, among others:
- RedMax technical drawings
- -5.10-BF manuals
- RedMax product data sheets
- information booklets
- or energy labels RedMax -5.10-BF
All of them are important, but the most important information from the point of view of use of the device are in the user manual RedMax -5.10-BF.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals RedMax -5.10-BF, service manual, brief instructions and user manuals RedMax -5.10-BF. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product RedMax -5.10-BF.

Similar manuals

A complete manual for the device RedMax -5.10-BF, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use RedMax -5.10-BF by users. Manuals are usually written by a technical writer, but in a language understandable to all users of RedMax -5.10-BF.

A complete RedMax manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual RedMax -5.10-BF - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the RedMax -5.10-BF, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the RedMax -5.10-BF, that we can find in the current document
3. Tips how to use the basic functions of the device RedMax -5.10-BF - which should help us in our first steps of using RedMax -5.10-BF
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with RedMax -5.10-BF
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of RedMax -5.10-BF in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning RedMax -5.10-BF?

Use the form below

If you did not solve your problem by using a manual RedMax -5.10-BF, ask a question using the form below. If a user had a similar problem with RedMax -5.10-BF it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)