Manual Quantum Data 822S

12 pages 0.46 mb
Download

Go to site of 12

Summary
  • Quantum Data 822S - page 1

    68-00183 Re v. C Quantum Data, Inc. Page 1 M ODEL 822S Programmable Monochrome Video Signal Generator Quantum Data, Inc. T able of Contents Making Connections .... 2 Proper Video Termination ................... 3 Front Panel Operation ... 4 Special Operating Mode (Probe Pulse) ..... 5 Special Operating Mode (Reinitializing Memory) ................. ...

  • Quantum Data 822S - page 2

    Page 2 Model 822S Quick Start Guide Making Connections (Power & Test Signals) AC Mains Input & Switch 85 - 264 VAC 48 - 440 Hz Sine 300 Watts Max. Analog Video Output 50 Ohm Differential Analog Output Level Calibration Inputs Blank module for Model 822S Video Module - Monochrome Output Blank module for Model 822S Vertical and Horizontal Syn ...

  • Quantum Data 822S - page 3

    68-00183 Re v. C Quantum Data, Inc. Page 3 Proper Video Termination Improper termination of the video outputs will result in degradation (ringing, undershoot and/or overshoot) of the test signals . The following figures show suggested methods for connecting the video generator to displays having 50 and 75 Ohm input impedances in both differential a ...

  • Quantum Data 822S - page 4

    Page 4 Model 822S Quick Start Guide Front Panel Operation (Normal Mode) Format Knob Selects a signal format from knob list. Image Knob Selects a test image (pattern) from knob list. Outputs Button T urns all signal outputs on and off Sync Gate Buttons T urn different sync types on and off Video Gate Buttons T urn individual video elements on and of ...

  • Quantum Data 822S - page 5

    68-00183 Re v. C Quantum Data, Inc. Page 5 Special Operating Modes Probe Sync Pulse Output The FS connector on the sync module can output a TTL Level probe pulse that can be used to trigger an oscilloscope or to synchronize a camera used in automated vision systems. The pulse can be positioned manually by the operator or by commands sent by a test ...

  • Quantum Data 822S - page 6

    Page 6 Model 822S Quick Start Guide Special Operating Modes Probe Sync Pulse Output (Continued) There are two additional Probe Pulse operating modes available when outputting a progressive (non- interlaced) video format. Pressing the “R” video gating button will produce a probe pulse for each scan line that contains active video. The bottom row ...

  • Quantum Data 822S - page 7

    68-00183 Re v. C Quantum Data, Inc. Page 7 Special Operating Modes Reinitializing Memory ! Reinitializing the generator ’s memory erases all user created data and sets all video ampli- tude calibration factors to 0.000. This will disable the video outputs until self calibration is performed. 1) The easiest way to start the procedure is to use the ...

  • Quantum Data 822S - page 8

    Page 8 Model 822S Quick Start Guide Y ou can also start the procedure by sending the following command string to the generator’s comm port while the unit is running: AVCM 1; fmtu <carriage return> Details on the connections can be found on a later page. 2) The LCD will display a prompt asking you to make the connections for calibration. 5) ...

  • Quantum Data 822S - page 9

    68-00183 Re v. C Quantum Data, Inc. Page 9 Programming and Operation via Computer Computer Data Po rts: RS-232 (9 pin male D-Sub) 2400 Baud (factory default) 8 Data Bits / 1 Stop Bit / No Parity Pin #2 Data in / Pin #3 Data out Pin #4 DTR in Pin #7 RTS out / Pin #8 CTS in GPIB (24 pin micro-ribbon recept.) Protocol: IEEE-488.2 NOTE: GPIB address sw ...

  • Quantum Data 822S - page 10

    Page 10 Model 822S Quick Start Guide Video Timing Pixel Clock: Range: 7.5 MHz - 600 (optionally 800 MHz) Step: < 0.25 Hz Jitter: < 60 pS line to line (One Sigma) Accuracy: 25 ppm (electronically trimmable to 0 ppm Horizontal Timing Frequency: 1 KHz - 330 KHz T ypical T otal pixels per line: Range: 128 to 65,535 Pixels Step: 1 Pixel (4 Pixels, ...

  • Quantum Data 822S - page 11

    68-00183 Re v. C Quantum Data, Inc. Page 11 User Interface Front Panel: 16 x 2 character LCD LED backlight Format & image selector knobs Invert, video gate, sync gate, output on/off buttons MS-Windows 95/98, NT: Virtual front panel Format, image& sequence editors File management Configure (start-up) file editor MS-DOS Command line: T ermina ...

  • Quantum Data 822S - page 12

    Page 12 Model 822S Quick Start Guide Quantum Data, Inc. 2111 Big Timber Rd. Elgin, IL 60123-1100 USA Main T el: (847) 888-0450 Facsimile: (847) 888-2802 Website: www.quantumdata.com Product Support and Service T oll free telephone number in USA 1-888-252-6133 From all other countries: [1] 847-888-0450 then select option 3 E-Mail: support@quantumdat ...

Manufacturer Quantum Data Category Projector

Documents that we receive from a manufacturer of a Quantum Data 822S can be divided into several groups. They are, among others:
- Quantum Data technical drawings
- 822S manuals
- Quantum Data product data sheets
- information booklets
- or energy labels Quantum Data 822S
All of them are important, but the most important information from the point of view of use of the device are in the user manual Quantum Data 822S.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Quantum Data 822S, service manual, brief instructions and user manuals Quantum Data 822S. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Quantum Data 822S.

Similar manuals

A complete manual for the device Quantum Data 822S, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Quantum Data 822S by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Quantum Data 822S.

A complete Quantum Data manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Quantum Data 822S - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Quantum Data 822S, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Quantum Data 822S, that we can find in the current document
3. Tips how to use the basic functions of the device Quantum Data 822S - which should help us in our first steps of using Quantum Data 822S
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Quantum Data 822S
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Quantum Data 822S in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Quantum Data 822S?

Use the form below

If you did not solve your problem by using a manual Quantum Data 822S, ask a question using the form below. If a user had a similar problem with Quantum Data 822S it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)