Manual Fujitsu B120

68 pages 1.95 mb
Download

Go to site of 68

Summary
  • Fujitsu B120 - page 1

    SERVER SERVER SERVER SERVER PRIMERGY B120 PRIMERGY B120 PRIMERGY B120 PRIMERGY B120 Intel-based Server Systems OPERATING MANUAL OPERATING MANUAL OPERATING MANUAL OPERATING MANUAL ...

  • Fujitsu B120 - page 2

    Are there ... ... any technical problems or other questions you need clarified? Please contact: • one of our service partners • your sales partne r • your sales outlet Further information can be found in the guarantee booklet or in the service address booklet. The latest information on our products, tips, updates, etc., can be found on the In ...

  • Fujitsu B120 - page 3

    ...

  • Fujitsu B120 - page 4

    Dieses Handbuch wurde auf Recycling-Papier gedruckt. This manual has been printed on recycled paper. Ce manuel est imprimé sur du papier recyclé. Este manual ha sido impreso sobre papel reciclado. Questo manuale è stato stampato su carta da riciclaggio. Denna handbok är tryckt på recyclingpapper. Dit handboek werd op recycling-papier gedrukt. ...

  • Fujitsu B120 - page 5

    PRIMERGY B120 Operating Manual Introduction Important notes Installation Pi f d Preparation for use and operation Openin g and closin g the server Propert y and data protection Troubleshootin g and tips S y stem components and expansions Index February 2001 edition ...

  • Fujitsu B120 - page 6

    Microsoft, MS, MS-DOS, Windows and Windows NT are registered trademarks of Microsoft Corporation. VESA and DPMS are trademarks of Video Electronics Standards Association. PS/2 is a registered trademark of International Business Machines, Inc. Pentium is a registered trademark of Intel Corporation, USA. All other trademarks referenced are trademarks ...

  • Fujitsu B120 - page 7

    A26361-K646-Z102-1-7619 Contents 1 Introduction .................................................................................................................................. 1 1.1 Features ...................................................................................................................................... 1 1.2 Notational conv ...

  • Fujitsu B120 - page 8

    Contents A26361-K646-Z102-1-7619 7.8 Time and/or date is not correct .................................................................................................. 41 7.9 System does not boot ............................................................................................................... 41 7.10 Drives "dead" at system ...

  • Fujitsu B120 - page 9

    A26361-K646-Z102-1-7619 1 1 Introduction The PRIMERGY B120 server is an Intel-based server for small and medium-sized networks and can be used as a tower (floorstand) or rack servers. Conversion to the respective other version is possible with an optional conversion kit. The PRIMERGY B120 Server offers a high level of failure protection and availab ...

  • Fujitsu B120 - page 10

    Introduction Features 2 A26361-K646-Z102-1-7619 Power supply The PRIMERGY B120 server is equipped with a permanently installed power supply. High level of availability and failure protection When memory data are accessed, 1-bit errors in the main memory are recognized and automatically corrected with the ECC (Error Correcting Code) method. ASR& ...

  • Fujitsu B120 - page 11

    Notational conventions Introduction A26361-K646-Z102-1-7619 3 1.2 Notational conventions The meanings of the symbols and fonts used in this manual are as follows: ! Pay particular attention to texts marked with this symbol. Failure to observe this warning endangers your life, destroys the system, or may lead to loss of data. i Supplementary informa ...

  • Fujitsu B120 - page 12

    Introduction Technical data 4 A26361-K646-Z102-1-7619 Standards Product safety and ergonomics IEC 60950 / EN 60950 UL 1950, CSA 22.2 No. 950 Electromagnetic compatibility (standard power supply) Emitted interference RF interference suppression FCC class B EN 55022, EN 61000-3-2, EN 61000-3-3 EN 50024 CE mark as per EC guideline Low-Voltage Directiv ...

  • Fujitsu B120 - page 13

    A26361-K646-Z102-1-7619 5 2 Important notes In this chapter you will find information regarding safety which it is essential to take note of when working with your server. The manufacturer's notes contain helpful information on your server. 2.1 Safety ! The following safety notes are also provided in the manual "Safety, Guarantee and Ergo ...

  • Fujitsu B120 - page 14

    Important notes Safety 6 A26361-K646-Z102-1-7619 Poper operation of the system, warranty features ! WARNING! • Proper operation of the device (in accordance with IEC 60950/DIN EN60950) is only ensured if the casing is completely assembled and the rear covers have been put in place (electric shock, cooling, fire protection, interference suppressio ...

  • Fujitsu B120 - page 15

    CE certificate Important notes A26361-K646-Z102-1-7619 7 Modules with electrostatic sensitive components Boards with electrostatic sensitive devices (ESD) may be identified by labels. When you handle boards fitted with ESDs, you must observe the following points under all circumstances: • You must always discharge yourself (e. g. by touching a gr ...

  • Fujitsu B120 - page 16

    Important notes FCC Class B Compliance Statement 8 A26361-K646-Z102-1-7619 2.3 FCC Class B Compliance Statement The following statement applies to the products covered in this manual, unless otherwise specified herein. The statement for other products will appear in the accompanying documentation. NOTE: This equipment has been tested and found to c ...

  • Fujitsu B120 - page 17

    Disposal and recycling Important notes A26361-K646-Z102-1-7619 9 2.5 Disposal and recycling Environmentally friendly product design and development This product has been designed in accordance with the FSC standard “environmentally friendly product design and development”. This means that the designers have taken into account decisive criteria ...

  • Fujitsu B120 - page 18

    ...

  • Fujitsu B120 - page 19

    A26361-K646-Z102-1-7619 11 3 Installation ! Please take note of the safety information in the chapter " Important notes ". Do not expose the server to extreme environmental conditions (see section " Technical data "). Protect it from dust, humidity and heat. i There must be a clearance of at least 200 mm in front of and behind t ...

  • Fujitsu B120 - page 20

    Installation Instructions on connecting and disconnecting cables 12 A26361-K646-Z102-1-7619 3.3 Instructions on connecting and disconnecting cables ! Be sure to read the documentation on the external devices before connecting them. Do not connect or disconnect cables during a thunderstorm. Always take hold of the actual plug. Never unplug a cable b ...

  • Fujitsu B120 - page 21

    Setting up the tower server Installation A26361-K646-Z102-1-7619 13 3.4.1 Connecting the tower server to the line voltage The server is equipped with a permanently installed standard power supply. Two standard designs are available for the power supply. The only difference between them is that the connection panel is rotated 180°. Since the connec ...

  • Fujitsu B120 - page 22

    Installation Installing rack-server in/removing from rack 14 A26361-K646-Z102-1-7619 3.4.2 Connecting the monitor to the line voltage On the server with the standard power supply it is possible to connect the power cable of the monitor to the server. 2 1 Ê Depending on the connector and the power supply, plug the monitor's power cable into ei ...

  • Fujitsu B120 - page 23

    Installing rack-server in/removing from rack Installation A26361-K646-Z102-1-7619 15 3.5.1 Mounting the slide-in module 1 2 Ê Screw together the front panel and the bottom tray to form a slide-in module (1 + 2). Ê Place the server in the slide-in module with the right side facing downward and somewhat offset toward the rear. ...

  • Fujitsu B120 - page 24

    Installation Installing rack-server in/removing from rack 16 A26361-K646-Z102-1-7619 Ê Push the server up to the front panel. 2 1 Ê Secure the server at the back to the bottom tray with the angled mounting bracket (1 + 2). ...

  • Fujitsu B120 - page 25

    Installing rack-server in/removing from rack Installation A26361-K646-Z102-1-7619 17 3.5.2 Installing the slide-in module The server requires five height units. The sliding rails are mounted in the bottom height unit. One height unit is equal to 4.445 cm = 1 ¾ inches. Fitting spring nuts 2 3 ca 45° 4 5 5 1 Ê Insert the spring nuts in the corresp ...

  • Fujitsu B120 - page 26

    Installation Installing rack-server in/removing from rack 18 A26361-K646-Z102-1-7619 Mounting cage nuts 1 2 3 1 2 3 Ê Mount the cage nut with the lower cage section in the corresponding mounting hole as shown in the illustration (1). Ê Then pry and pull the upper section of the cage nut into the mounting hole with the tool supplied (2). The cage ...

  • Fujitsu B120 - page 27

    Installing rack-server in/removing from rack Installation A26361-K646-Z102-1-7619 19 2 1 Place the server on the slide rails in the rack (1) and secure the server with the four knurled screws in the rack (2). 3.5.3 Connecting the rack server to the line voltage The server is equipped with a permanently installed standard power supply. Two standard ...

  • Fujitsu B120 - page 28

    Installation Prepare the keyboard 20 A26361-K646-Z102-1-7619 1 2 Ê Plug the power cable of the server into the server (1) and into a free electrical outlet of the multi-outlet assembly in the rack (2) (see technical manual for rack). Guide the cable through the cable routings of the rack. 3.6 Prepare the keyboard Ê Plug the appropriate connector ...

  • Fujitsu B120 - page 29

    Connecting devices to the server Installation A26361-K646-Z102-1-7619 21 3.7 Connecting devices to the server All ports are on the rear of the server. Which ports are available on your server depend on the boards installed. The standard ports are marked with symbols and some are color-coded. 7 6 3 4 5 2 1 Tow er 7 63 4 5 2 1 Rac k 1 = Mouse 2 = Par ...

  • Fujitsu B120 - page 30

    Installation Connecting devices to the server 22 A26361-K646-Z102-1-7619 ! If you connect the monitor power cable to the monitor power outlet of a server with the standard power supply, then the current consumption of the monitor may not exceed 1.5 A (at 230 V) or 3 A (at 115 V). The rated current for the monitor is also given on the monitor itself ...

  • Fujitsu B120 - page 31

    A26361-K646-Z102-1-7619 23 4 Preparation for use and operation ! Please take note of the safety information in the chapter " Important notes ". i Work steps which are identical for the tower and rack version are only described for the tower version. For details on the rack variant, please see the Technical Manual for the rack. 4.1 Unlocki ...

  • Fujitsu B120 - page 32

    Preparation for use and operation Unlocking/locking the tower server 24 A26361-K646-Z102-1-7619 Enabling access to the hard disk drives 4 3 2 1 Ê Unlock the server (1). Ê Slide up the drive cover as far as possible (2). Ê Remove the hard disk cover toward the front (3 + 4). The hard disk cover is remounted and the server connected in the reverse ...

  • Fujitsu B120 - page 33

    Operation controls Preparation for use and operation A26361-K646-Z102-1-7619 25 4.2 Operation controls 6 4 7 5 2 1 3 8 9 7 4 65 2 1 3 9 8 1 = Floppy disk drive with power-on indicator 2 = CD-ROM drive with power-on indicator 3 = Lock 4 = Chipcard reader with power-on indicator (optional) 5 = IDE busy indicator 6 = Message indicator 7 = ON/OFF switc ...

  • Fujitsu B120 - page 34

    Preparation for use and operation Operation controls 26 A26361-K646-Z102-1-7619 4.2.1 Operation controls Lock unlocks or locks the server. ON/OFF switch switches the server to ready-to-operate or on. i The ON/OFF switch and the main switch do not disconnect the server from the line voltage. To disconnect the line voltage completely, remove the powe ...

  • Fujitsu B120 - page 35

    Switching the server on and off Preparation for use and operation A26361-K646-Z102-1-7619 27 4.3 Switching the server on and off ! If after switching on the server there is nothing but flickering stripes on the screen, switch the server off immediately (see " Troubleshooting and tips "-" Flickering stripes on the monitor screen " ...

  • Fujitsu B120 - page 36

    Preparation for use and operation Switching the server on and off 28 A26361-K646-Z102-1-7619 Server is switched off The main switch (a) is in position 0 and the power-on indicator does not light. The ON/OFF switch (b) is inoperative. The screen socket on the server is dead. Server is ready for operation (stand-by state) The main switch (a) is in po ...

  • Fujitsu B120 - page 37

    Configuring the server Preparation for use and operation A26361-K646-Z102-1-7619 29 4.4 Configuring the server This section contains information of the server configuration and on installing the operating system. Make sure that the energy saving functions are disabled in the BIOS Setup during server operation. 4.4.1 Configuration with ServerStart W ...

  • Fujitsu B120 - page 38

    Preparation for use and operation Locking the tower server 30 A26361-K646-Z102-1-7619 4.5 Locking the tower server Fitting the hard disk cover 2 3 4 5 1 Ê If the server is locked, unlock it (1). Ê Slide the drive cover completely upwards (2). Ê Fit the hard disk cover (3 + 4). Ê Slide the drive cover downwards (5). ...

  • Fujitsu B120 - page 39

    Cleaning the server Preparation for use and operation A26361-K646-Z102-1-7619 31 Locking the server Ê Slide the drive cover upwards (1). Ê Lock the server (2). 4.6 Cleaning the server ! Switch the server off and pull the power plug out of the grounded-contact power socket. Do not clean any interior parts yourself, leave this job to a service tech ...

  • Fujitsu B120 - page 40

    ...

  • Fujitsu B120 - page 41

    A26361-K646-Z102-1-7619 33 5 Opening and closing the server ! Please take note of the safety information in the chapter " Important notes ". Ê Switch the server off. ! Pull the power plug out of the power outlet. Ê Disconnect all cables on the rear that are obstructing you. 5.1 Opening and closing the tower server 1 4 2 3 Ê Unlock the ...

  • Fujitsu B120 - page 42

    Opening and closing the server Opening and closing the rack server 34 A26361-K646-Z102-1-7619 5.2 Opening and closing the rack server 2 1 Ê Release the four knurled screws (1) and pull the server carefully out of the rack up to the stop (2). 1 2 Ê Press the locking springs on both sides of the server (1) and carefully remove the server from the r ...

  • Fujitsu B120 - page 43

    Opening and closing the rack server Opening and closing the server A26361-K646-Z102-1-7619 35 4 3 2 1 Ê Unlock the server (1). Ê Unscrew the two knurled screws (2). Ê Push the top cover approx. 2 cm backwards (3). Ê Lift off the top cover upwards (4). Ê Closing is performed in the reverse order. ...

  • Fujitsu B120 - page 44

    ...

  • Fujitsu B120 - page 45

    A26361-K646-Z102-1-7619 37 6 Property and data protection The tower server is protected against unauthorized opening with the lock. Regardless of this, two intrusion detection switches are employed with which the ServerView program recognizes and logs any removal of the housing side cover and the hard disk cover. To prevent the tower server from be ...

  • Fujitsu B120 - page 46

    ...

  • Fujitsu B120 - page 47

    A26361-K646-Z102-1-7619 39 7 Troubleshooting and tips ! Take note of the safety notes in the manual "Safety and Ergonomics" and in the chapter " Installation ", when you connect or disconnect cables. If a fault occurs, try to correct it according to the following procedures. These are described: • in this chapter • in the do ...

  • Fujitsu B120 - page 48

    Troubleshooting and tips Flickering stripes on the monitor screen 40 A26361-K646-Z102-1-7619 Brightness control is set to dark Ê Set the brightness control to bright. For detailed information, please refer to the Operating Manual supplied with your monitor. Power cable or monitor cable not connected Ê Switch off the monitor and the server. Ê Che ...

  • Fujitsu B120 - page 49

    No mouse pointer displayed on the screen Troubleshooting and tips A26361-K646-Z102-1-7619 41 7.6 No mouse pointer displayed on the screen Mouse driver not loaded Ê Check whether the mouse driver is properly installed and is present when the application program is started. Detailed information can be found in the User Guides of the mouse, the opera ...

  • Fujitsu B120 - page 50

    Troubleshooting and tips Drives "dead" at system boot 42 A26361-K646-Z102-1-7619 7.10 Drives "dead" at system boot SCSI drives are reported as "dead" at system boot. This error message may occur when the server has a disk array controller. SCSI cabling incorrect Ê Make sure the SCSI cable connection and the SCSI chann ...

  • Fujitsu B120 - page 51

    A26361-K646-Z102-1-7619 43 8 System components and expansions This chapter describes how to modify your server hardware (e.g. installing or removing boards or accessible drives). Work steps which are identical for the tower and rack version are only described for the tower version. Memory and processor upgrading as well as replacement of the lithiu ...

  • Fujitsu B120 - page 52

    System components and expansions The SCSI hard disk subsystem 44 A26361-K646-Z102-1-7619 The following applies if SCSI hard disk drives are operated on a disk array controller: • RAID level 0 and 7 Rebuild is not possible. If a hard disk fails, its data is lost. • RAID level 1 and 5 without standby hard disk Rebuild on the new disk is carried o ...

  • Fujitsu B120 - page 53

    The SCSI hard disk subsystem System components and expansions A26361-K646-Z102-1-7619 45 Function of the indicators Green indicator The green LED lights up when the hard disk is accessed. You may not replace the hard disk at this time! Orange indicator The orange indicator flashes when, in conjunction with a Disk Array Controller, the configuration ...

  • Fujitsu B120 - page 54

    System components and expansions The SCSI hard disk subsystem 46 A26361-K646-Z102-1-7619 8.1.3 Installing/removing a SCSI hard disk drive If a hard disk drive is to be installed in a bay in which no hard disk drive is previously installed, then the blind insert must be removed from this bay beforehand. 2 1 Ê Swivel the slide-in module handle of th ...

  • Fujitsu B120 - page 55

    The SCSI hard disk subsystem System components and expansions A26361-K646-Z102-1-7619 47 8.1.4 SCSI platter for four 1-inch hard disk slide-in modules The hot-replace SCSI platter connects up to four 1-inch hard disk slide-in module with the SCSI controller and supports Ultra3 Wide SCSI (U160 SCSI). SCS I ID 3 SCSI I D 1 SCSI I D 0 SCS I ID 2 1 4 2 ...

  • Fujitsu B120 - page 56

    System components and expansions Accessible drives 48 A26361-K646-Z102-1-7619 8.2 Accessible drives The server accommodates three accessible drives (two 5 ¼-inch drives and one 3 ½-inch drive). As shipped, two drives are fitted: a 3 ½ -inch floppy disk drive and a CD-ROM drive. When installing or removing drives, the following points must be obs ...

  • Fujitsu B120 - page 57

    Accessible drives System components and expansions A26361-K646-Z102-1-7619 49 8.2.1 Installing/Removing an accessible 5 ¼-inch drive Ê Shut down the operating system. Ê Switch off the server, and disconnect it from the network. ! Switching off the server does not disconnect the device from the network. To completely disconnect the device from th ...

  • Fujitsu B120 - page 58

    System components and expansions Accessible drives 50 A26361-K646-Z102-1-7619 8.2.2 Changing the floppy disk drive Ê Shut down the operating system. Ê Switch off the server, and disconnect it from the network. ! Switching off the server does not disconnect the device from the network. To completely disconnect the device from the network, remove t ...

  • Fujitsu B120 - page 59

    Removing/installing boards System components and expansions A26361-K646-Z102-1-7619 51 8.3 Removing/installing boards Before installing or removing a board, please read the documentation supplied with the board. Ê Shut down the operating system. Ê Switch off the server, and disconnect it from the network. Ê Open the server (see " Opening an ...

  • Fujitsu B120 - page 60

    System components and expansions chipDISK for RemoteView 52 A26361-K646-Z102-1-7619 8.4 chipDISK for RemoteView To use RemoteView , the remote test and diagnosis system, on the server, a RemoteView chipDISK is available for the PRIMERGY B120 server as an option. The RemoteView chipDISK is equipped with an IDE interface and is mounted in the server ...

  • Fujitsu B120 - page 61

    chipDISK for RemoteView System components and expansions A26361-K646-Z102-1-7619 53 1 Ê Screw the chipDISK onto the side of the drive cage (1). Ê Connect the IDE data cable provided to the chipDISK (1) and to the primary IDE interface of the system board. Ê Connect the other end of the power supply cable to the appropriate connection on the syst ...

  • Fujitsu B120 - page 62

    System components and expansions Replacing the system fan 54 A26361-K646-Z102-1-7619 8.5 Replacing the system fan The server system fan can easily be replaced during servicing. Ê Open the server (see " Opening and closing the server "). 1 3 2 a Ê Pull the cable off the fan (1). Ê Press on the clip (2) from behind and remove the fan (3) ...

  • Fujitsu B120 - page 63

    Adapter module System components and expansions A26361-K646-Z102-1-7619 55 8.6 Adapter module The adapter module is located at the front in the base of the house. In addition to the system board it provides the following functions: • System fan control • Device ID • Error logging 1234 2 13 4 5 6 1 = DIP switch for setting the limit temperatur ...

  • Fujitsu B120 - page 64

    ...

  • Fujitsu B120 - page 65

    A26361-K646-Z102-1-7619 57 9 Index 5 5 ¼-inch drive installing 49 removing 49 A Accessible drive 48 installing 49 removing 49 Adapter module 55 ASR&R 2 B Battery 6 replacing 55 BIOS Update 2 Blind insert removing 46 Board 51 installing 51 removing 51 safety 7 C Cable connecting 12 disconnecting 12 Cage nut, inserting 18 CD-ROM drive indicator ...

  • Fujitsu B120 - page 66

    Index 58 A26361-K646-Z102-1-7619 system does not boot 41 time 41 wrong date 41 Error logging 55 ESD 7 Extensions, system board 55 F Fan, exchanging 54 FCC statement 8 Features 1 Flickering stripes on the monitor screen 40 Floppy disk drive changing 50 indicator 26 Floppy disk, cannot be read or written 41 Further information 1 G GAM 29 General info ...

  • Fujitsu B120 - page 67

    Index A26361-K646-Z102-1-7619 59 Opening 33 Operating system installing 29 not starting 41 Operation 23 Overview features 1 ports and slots 21 P Packing material 9 , 11 Parallel port 21 PDA technology 2 Plastic casing parts, Label; 9 Poper operation of the system 6 Ports 21 Power-on indicator 26 doesn't fail to light 39 Preparation for use 23 ...

  • Fujitsu B120 - page 68

    Index 60 A26361-K646-Z102-1-7619 drive reported as dead 42 flickering screen 40 floppy disk cannot be read/written 41 message on the screen 42 no mouse pointer 41 screen 39 screen display drifts 40 server 39 server switches itself off 39 system does not boot 41 Troubleshooting and tips 39 U U160 SCSI 47 Ultra160 SCSI 43 Ultra3 Wide SCSI 47 Unlockin ...

Manufacturer Fujitsu Category Server

Documents that we receive from a manufacturer of a Fujitsu B120 can be divided into several groups. They are, among others:
- Fujitsu technical drawings
- B120 manuals
- Fujitsu product data sheets
- information booklets
- or energy labels Fujitsu B120
All of them are important, but the most important information from the point of view of use of the device are in the user manual Fujitsu B120.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Fujitsu B120, service manual, brief instructions and user manuals Fujitsu B120. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Fujitsu B120.

A complete manual for the device Fujitsu B120, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Fujitsu B120 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Fujitsu B120.

A complete Fujitsu manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Fujitsu B120 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Fujitsu B120, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Fujitsu B120, that we can find in the current document
3. Tips how to use the basic functions of the device Fujitsu B120 - which should help us in our first steps of using Fujitsu B120
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Fujitsu B120
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Fujitsu B120 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Fujitsu B120?

Use the form below

If you did not solve your problem by using a manual Fujitsu B120, ask a question using the form below. If a user had a similar problem with Fujitsu B120 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)