  • RAD Data comm T1 - page 1

    FOM-E1/T1 Installation and Operation Manual E1/T1 Fiber Optic Modem ...

  • RAD Data comm T1 - page 2

    ...

  • RAD Data comm T1 - page 3

    FOM-E1/T1 E1/T1 Fiber Optic Modem Installation and Operation Manual Notice T h i s m a n u a l c o n t a i n s i n f o r m a t i o n t h a t i s p r o p r i e t a r y t o R A D D a t a C o m m u n i c a t i o n s L t d . ( " R A D " ) . N o part of this publication may be reproduced in any form whatsoever without prior written approval by ...

  • RAD Data comm T1 - page 4

    Limited Warranty RAD warrants to DISTRIBUTOR that the hardware in the F OM-E 1/T1 to be delivered hereunder sh all be free of defects i n material and workmanship unde r normal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR. If, during the warranty period, any component part of the equipment becomes ...

  • RAD Data comm T1 - page 5

    General Safety Instructions The following in structions ser ve as a general guid e for the safe installation and op eration of telecommunications products. Addition al i nstructions, if appl icable, are included ins ide the manual. Safety Symbols This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding ...

  • RAD Data comm T1 - page 6

    Handling Energized Products General Safety Practices Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the powe r switch (if installed) is in the OFF position or a fuse is blown. For DC-powered products, although the vo ltages levels are usually not hazardou ...

  • RAD Data comm T1 - page 7

    Connection of Data and Telecommunications Cables Data and telecommunicatio n interfaces are classified accor ding to their safety status. The following table list s the status of several standard in terfaces. If the st atus of a given port differs from the standard one, a no tice will be given i n the manual. Ports Safety Status V.11, V.28, V.35, V ...

  • RAD Data comm T1 - page 8

    To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords. Pour réduire les risques s’incendie, utiliser seulement des conducteurs de télécommunications 26 AWG ou de section supérieure. Some ports are suitable for connection to intra-buildin g or non-exposed wiring or cabling only. In such cases, a notice will be ...

  • RAD Data comm T1 - page 9

    Canadian Emission Requirements This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulation. Cet appareil numérique de la classe A respecte to utes les exigences du Règlement sur le matériel brouilleur du Canada. Warning per EN 55022 (CISPR- 22) This is a class A product. In a domestic envir ...

  • RAD Data comm T1 - page 10

    Declaration of Conformity Manufacturer's Name: RAD Data Communications Ltd. Manufacturer's Address: 24 Raoul Wallenberg St. Tel Aviv 69719 Israel declares that the product: Product Name: FOM-E1/T1 conforms to the following standard(s ) or other normative document(s): EMC : EN 55022 (1994) Limits and methods of measurement of radio disturb ...

  • RAD Data comm T1 - page 11

    Installing FOM-E1/T1 1 Quick Start Guide Installation of FOM-E1/T 1 should be carried out on ly by an experienced technician. If you are familiar with FOM-E1/T 1, use this quick start guide to set it up for operation. This guide describes the standalone ve rsion of the modem. Perform the installation procedures for both the local and the re mote un ...

  • RAD Data comm T1 - page 12

    Quick Start Guide FOM-E1/T1 Installation and Operation Manual 2 Operating FOM-E1/T1 Connecting the Cables  To connect cables: 1. Connect the E1/T1 electrical interface. 2. Connect the fiber optic interface. 3. Connect the power cable (first to the modem, then to the mains). Operation starts when the power is a pplied to the rear panel power conn ...

  • RAD Data comm T1 - page 13

    FOM-E1/T1 Installation and Operation Manual i Contents Chapter 1. Introduction 1.1 Overview ..................................................................................................................... 1-1 Versio ns ....................................................................................................................... ...... ...

  • RAD Data comm T1 - page 14

    Table of Contents ii FOM-E1/T1 Installation and Operation Manual 5.4 Installing the FOM-E1/T1/R Car d ................................................................................. 5-5 Setting Internal Ju mpers and Switch es ................................................................................... 5-5 Installing FOM-E1/T1/R into the AS ...

  • RAD Data comm T1 - page 15

    Overview 1-1 Chapter 1 Introduction 1.1 Overview This manual provides info rmation on the technical characteristics, installation and operation of the FOM-E1/T1 fiber optic mode m as a standalone unit, an d as FOM-E1/T1/R rack-mount card for the ASM-MN-2 14 modem rack. FOM-E1/T1 is a fiber optic modem for transmission of E1 (2. 048 Mbps) or T1 (1.5 ...

  • RAD Data comm T1 - page 16

    Chapter 1 Introduction FOM-E1/T1 Installation and Operation Manual 1-2 Overview Application In the application illustrate d, each FOM-E1/T1 receives E1 or T1 signals that are equalized to overcome electrical link di stortion. FOM-E1/T1 then converts the E1 or T1 signals into an optical signal. PBX FOM-E1/T1 FOM-E1/T1 DACS E1/T1 E1 /T1 E1/T1 Coax Fi ...

  • RAD Data comm T1 - page 17

    FOM-E1/T1 Installation and Operation Manual Chapter 1 Introduction Functional Description 1-3 1.2 Physical Description FOM-E1/T1 is a compact unit , intended for installation on desktops or shelves. An optional rack-mount adapter kit enables FOM-E1/T1 installatio n into a 19-inc h rack. Figure 1-2 shows a 3D view of FOM-E1/T1. Figure 1-2 FO M-E1/T1 ...

  • RAD Data comm T1 - page 18

    Chapter 1 Introduction FOM-E1/T1 Installation and Operation Manual 1-4 Functional Description Signal Conversion Conversion of the electrical signal into an optical signal takes place by using an infrared light-emitting diode or laser transmitter. At the opposite end of the fiber, the optical signal is converted back into an electrical signal an d a ...

  • RAD Data comm T1 - page 19

    FOM-E1/T1 Installation and Operation Manual Chapter 1 Introduction Technical Specifications 1-5 1.4 Technical Specifications E1/T1 Interface Transmission Rates E1: 2.048 Mbps T1: 1.544 Mbps Interface User-selectable: • E1: 120 Ω balanced or 75 Ω unbalanced • T1: 100 Ω balanced Zero Suppression E1: HDB3 T1: B8ZS Connectors Balanced: 15-pin ...

  • RAD Data comm T1 - page 20

    Chapter 1 Introduction FOM-E1/T1 Installation and Operation Manual 1-6 Technical Specifications Physical Height 44 mm / 1. 7 in (1U) Width 179 mm / 7.0 in Depth 203 mm / 8.0 in Weight 1.1 kg / 3.0 lb Power AC Voltage 115 or 230 VAC ( ± 10%), 50 or 60 Hz, 6W DC Voltage 24 VDC (18 to 36 VDC) or -48 VDC (-36 to -72 VDC) Fuses FOM-E1/T1: • 115 VAC s ...

  • RAD Data comm T1 - page 21

    Package Contents 2-1 Chapter 2 Installation and Setup This chapter describes installation and setup procedures for the standalone FOM-E1/T1 modem. FOM-E1/T1 is delivered c omp letely assembled. It is designe d for tabletop or 19-inch rack installatio n. For instructions on i nstallation of a single unit or t wo units in a 19-inch rack, refer to the ...

  • RAD Data comm T1 - page 22

    Chapter 2 Installation and Setup FOM-E1/T1 Installation and Operation Manual 2-2 Installation and Setup 2.3 Installation and Setup FOM-E1/T1 is a standalone device intended for tabl etop or bench installation. It is delivered completely assemble d. No provision is made for bolting the unit on the tabletop.  To install FOM-E1 /T1: 1. Determine th ...

  • RAD Data comm T1 - page 23

    FOM-E1/T1 Installation and Operation Manual Chapter 2 Installation and Setup Installation and Setup 2-3 Setting the SW1 and SW2 switches to CONNECTED is valid for coaxial cables only. When using 4-wire connection, set t hese switches to FLOATING. 5 . Slide the PCB interior back into the case. 6 . Screw in the two rear panel screws to se cure the PC ...

  • RAD Data comm T1 - page 24

    Chapter 2 Installation and Setup FOM-E1/T1 Installation and Operation Manual 2-4 Installation and Setup Table 2-1 FOM-E1/T 1 Internal Jumpers and Switch es Jumper/Switch Function Possible Settings Factory Setting SW3, AIS When a major alarm is detected, AIS is transmitted to either the electrical or optical interface. ON – Transmit AIS OFF – Do ...

  • RAD Data comm T1 - page 25

    FOM-E1/T1 Installation and Operation Manual Chapter 2 Installation and Setup Installation and Setup 2-5 2. Connect the transmit fiber to the conn ector marked TX and the receive fiber to the connector marked RX. 3. At the remote unit connect the transmit fiber to RX and the receive fiber to TX. Connecting the E1/T1 Interface The rear-panel E1/T1 co ...

  • RAD Data comm T1 - page 26

    Chapter 2 Installation and Setup FOM-E1/T1 Installation and Operation Manual 2-6 Installation and Setup Connecting AC Power AC power should be supp lied to FOM-E1 /T1 through the 1.5m (5 ft) standard power cable terminated by a stan dard 3-prong plug. The cable is provided with the unit.  To connect AC power: 1. Connect the power cable to the po ...

  • RAD Data comm T1 - page 27

    Front Panel Controls and Indi cators 3-1 Chapter 3 Operations This chapter provides the following information for the FOM-E1/T1 standalone modem: • FOM-E1/T1 front-panel in dicators and controls • Operating procedures (turn-on, fron t-panel indications, performance monitoring and turn-off). • Installation procedures given in Chapte r 2 must b ...

  • RAD Data comm T1 - page 28

    Chapter 3 Operations FOM-E1/T1 Installation and Operation Manual 3-2 Operating Instructions 3.2 Operating Instructions Turning On FOM-E1/T1 starts operatin g as soon as it is connected to the powe r source. The PWR LED turns ON and remain s lit as lo ng as the units are connected to the mains. Normal Operating Instructions During normal operation a ...

  • RAD Data comm T1 - page 29

    Status Indicators and Alarm Relay 4-1 Chapter 4 Testing and Diagnostics This chapter describes the FOM-E1/T1 diagno stics functions, which include: • Front panel LED indicators • Alarm relay • Diagnostic loopbacks. In addition, this chapter provides some tips on troubleshooting and frequently asked questions. 4.1 Status Indicators and Alarm R ...

  • RAD Data comm T1 - page 30

    Chapter 4 Testing and Diagnostics FOM-E1/T1 Installation and Operation Manual 4-2 Diagnostic Tests 4.2 Diagnostic Tests Local Analog Loopback (LLB) FOM-E1/T1 supports activ ation of a local loopback, which tests the performance of the E1/T1 electrical interface of the lo cal unit and equipment att ached to it. The data received at the E1/T1 electri ...

  • RAD Data comm T1 - page 31

    FOM-E1/T1 Installation and Operation Manual Chapter 4 Testing and Diagnostics Troubleshooting Instructions 4-3 4.3 Troubleshooting Instructions Table 4-2 provides troubleshooting details. Perform the actions listed under Corrective Measures in the order given in the table, until the problem is corrected. Table 4-2. Troubleshooting Chart Symptom Pro ...

  • RAD Data comm T1 - page 32

    Chapter 4 Testing and Diagnostics FOM-E1/T1 Installation and Operation Manual 4-4 Frequently Asked Questions 4.4 Frequently Asked Questions Q: Does FOM-E1/T1 oper ate opposite FOM-40? A: No. The fiber optic interfaces of these mo dems are not compatible. Q: Can I connect FOM-E1/T1 with a bala nced interface to FOM- E1/T1 with an unbalanced interfac ...

  • RAD Data comm T1 - page 33

    ASM-MN-214 Card Cage 5-1 Chapter 5 FOM-E1/T1/R Card Version This chapter describes the card cage ve rsion of FOM-E1/T1. It discusses the following topics: • ASM-MN-214 card cage • FOM-E1/T1/R plug-in car d for the ASM-MN-214 c age • Cage and card power supply • Installation of cage and card. 5.1 ASM-MN-214 Card Cage The ASM-MN-214 card cage ...

  • RAD Data comm T1 - page 34

    Chapter 5 FOM-E1/T1/R Card Version FOM-E1/T1 Installation and Operation Manual 5-2 Power Supply T erminal Bl ock CIA/TB- BNC/214 T erminal Bl ock Figure 5-1 AS M-MN-214 Rear Panel 5.2 Power Supply The FOM-E1/T1/R card is powered from the ASM-MN-214 po wer supply via its chassis. Each FOM-E1/T1/R card has t wo fuses that protect the entire system ag ...

  • RAD Data comm T1 - page 35

    FOM-E1/T1 Installation and Operation Manual Ch apter 5 FOM-E1/T1/R Card Version Power Supply 5-3 DC Supply The DC power supply is -48 VDC (- 36 to -72 VDC) or 24 VDC (18 to 32 VD C). It uses a DC/DC converter module to prov ide the power required for the cards. Power Supply Redundancy This special ordering option is equi pped with two separate powe ...

  • RAD Data comm T1 - page 36

    Chapter 5 FOM-E1/T1/R Card Version FOM-E1/T1 Installation and Operation Manual 5-4 FOM-E1/T1/R Front Panel 5.3 FOM-E1/T1/R Front Panel Figure 5-3 shows the FOM-E1/T1/R card front panel. The front panel of FOM-E1/T1/R includes fiber opt ic connectors, loopback init iation switch and LED indicators. The front panel LEDs of the card version are identi ...

  • RAD Data comm T1 - page 37

    FOM-E1/T1 Installation and Operation Manual Ch apter 5 FOM-E1/T1/R Card Version Installing the FOM-E1/T1/R Card 5-5 5.4 Installing the FOM-E1/T1/R Card Setting Internal Jumpers and Switches The FOM-E1/T1/R internal jumpers and swit ches are similar in their functionality to those of the standalo ne unit, as detailed Table 5-1 . Figure 5-4 illustrat ...

  • RAD Data comm T1 - page 38

    Chapter 5 FOM-E1/T1/R Card Version FOM-E1/T1 Installation and Operation Manual 5-6 Installing the FOM-E1/T1/R Card Table 5-1. FOM-E1/T 1/R Internal Ju mpers and Switches Jumper/Switch Function Possible Settings Factory Setting SW4, AIS When a major alarm is detected, AIS is transmitted to either the electrical or optical interface. ON – Transmit ...

  • RAD Data comm T1 - page 39

    Standalone FOM-E1/T1 A-1 Appendix A Interface Connector Specifications A.1 Standalone FOM-E1/T1 DB-15 Connector Balanced E1/T1 interface terminates in DB-15 female connector, which also serves as an ala r m r e lay. T a ble A - 1 desc r i bes the DB-15 pins that serve for the E1/T1 connection. Table A - 2 d e scribes the DB-15 pins t h at serve for ...

  • RAD Data comm T1 - page 40

    Appendix A Interface Connector Specifications FOM-E1/T1 Ins tallation and Operation Manual A-2 FOM-E1/T1/R Modem Card CBL-E1T1/RJ45 Cabl e RAD offers an optional splitter cable, CBL-E1T 1/RJ45, which connects the DB-1 5 female connector of the standalone unit to the balanced E1/T 1 device and a larm equipment. The CBL-E1T1/RJ45 cable includes two D ...

  • RAD Data comm T1 - page 41

    24 Raoul W allenberg St., T el Aviv 69719, Isr ael T el: +972-3-6458181, F ax: +972-3-6483331, +972-3- 6498250 E-mail: , W eb site: Customer Response Form RAD Data Communications would like your hel p in improving its product documentation. Please complete and return this form by mail or by fax or s end us an e-mail with your comments. Thank you fo ...

  • RAD Data comm T1 - page 42

    ...

  • RAD Data comm T1 - page 43

    Error Report Type of Error(s) ❒ Incompatibility with product or Problem(s): ❒ Difficulty in understanding text ❒ Regulatory information (Safety, Compliance, War nings, etc.) ❒ Difficulty in finding needed information ❒ Missing information ❒ Illogical flow of information ❒ Style (spelling, grammar, references, etc.) ❒ Appearance ❒ ...

  • RAD Data comm T1 - page 44

    ...

  • RAD Data comm T1 - page 45

    ...

  • RAD Data comm T1 - page 46

    900 Corporate Drive, Mahwah, N.J. 07430, Tel: (2 01) 529-1100 24 Raoul Wallenberg Street, Tel Aviv 69719, Israel, Tel: 972-3-6458181 U.S. HEADQUARTERS: INTERNATIONAL HEADQUARTER S: Publication No. 284-20 0-01/03 www.rad.com Fax: 972-3-6498250, 972-3-647 4436, Email: rad@rad.co.il Toll Free: 1-800-444-7234, Fa x: (201) 529-5777, Email: market@radusa ...

Manufacturer RAD Data comm Category Network Card

Documents that we receive from a manufacturer of a RAD Data comm T1 can be divided into several groups. They are, among others:
- RAD Data comm technical drawings
- T1 manuals
- RAD Data comm product data sheets
- information booklets
- or energy labels RAD Data comm T1
All of them are important, but the most important information from the point of view of use of the device are in the user manual RAD Data comm T1.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals RAD Data comm T1, service manual, brief instructions and user manuals RAD Data comm T1. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product RAD Data comm T1.

Similar manuals

A complete manual for the device RAD Data comm T1, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use RAD Data comm T1 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of RAD Data comm T1.

A complete RAD Data comm manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual RAD Data comm T1 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the RAD Data comm T1, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the RAD Data comm T1, that we can find in the current document
3. Tips how to use the basic functions of the device RAD Data comm T1 - which should help us in our first steps of using RAD Data comm T1
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with RAD Data comm T1
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of RAD Data comm T1 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning RAD Data comm T1?

Use the form below

If you did not solve your problem by using a manual RAD Data comm T1, ask a question using the form below. If a user had a similar problem with RAD Data comm T1 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)