Manual Kohler CFI230G

14 pages 1.53 mb
Download

Go to site of 14

Summary
  • Kohler CFI230G - page 1

    CFI230G Indigo Quadrant Enclosur e with integrated Mira Magna Shower System (6 46) Fitting Instructions 1 2 3 4 1 2 3 4 Slide Rail Fixed Head Kohler Daryl Limited Alfred Road, W allasey , W irral, CH4 4 7HY England T el 44 (0)151 6 06 5 000 Fax 44 (0)151 63 8 0303 www .daryl-showers.co.uk E-mail Daryl@daryl-showers.co.uk ...

  • Kohler CFI230G - page 2

    27 CF I230G CU ST OM E R S E RVI CE K ohler Daryl and Kohler Mira Daryl Showering have more than 38 years experience of manufacturing and designing shower enclosures of exceptional quality . For over 80 years, Mira Showers have had the s ame reputation for shower systems. Y our new showering product has been created by these two specialist organisa ...

  • Kohler CFI230G - page 3

    26 CFI2 30G 3 CFI2 30G Intro duction The following pages aim to provide comprehensive installation instructions, plus advice on how to care and maintain your product. W e recommend that the unit is installed by a qualified Plumber or Engineer . Please retain this document for future reference. Note: Due to our desire to always improve our products, ...

  • Kohler CFI230G - page 4

    4 CFI2 30G 25 CFI2 30G COM PON E NTS Lintel Standard T op Caps Parking Block Side Panel Door Splashguard Cap Fixed Roller The unit should be cleaned regularly . Use a non abrasive cleaner (ideally with a pH value of 4 to 8) applied with a soft cloth. Under no circumstances should scourers or power ful detegents be used as these can damage the metal ...

  • Kohler CFI230G - page 5

    24 CFI2 30G 5 CFI2 30G COM PON E NTS 5mm 3mm Slider Rail W ater Delivery System Roller Securing Caps Splashguard Aligning Roller Blanking Cap W ater Delivery T op Caps W ater Delivery W all Jamb & W all Channel Glass Panel x13 A x3 C x5 B x13 3mm 6mm OR Fixed Head W ater Delivery System 2m Pipe and Connector Electrical Cable TR OU B LE S H OO T ...

  • Kohler CFI230G - page 6

    6 CFI2 30G 23 CFI2 30G Remove wall channel fr om jamb and place against mark on wall Adjust wall jamb until glass is parallel to the edge of the tray ‘ A ’ . W hen jamb is vertical mark edge of wall channel on the wall ‘B’ . A B STEP 1 E NCLOSU R E I N ST ALLA TI ON Non W ater Delivery Side only Loosely fit wall c hannel into glass panel ja ...

  • Kohler CFI230G - page 7

    22 CFI2 30G 7 CFI2 30G Check the wall c hannel is vertic al and mark through the 3 holes ‘ A ’ A Drill 3 x 6mm holes Fit plugs Loosely fit scr ews A Seal behind channel and tighten screws A B STEP 5 STEP 6 STEP 7 STEP 8 Slide glass panel into slot in tray “ A ’ and fit jamb into wall channel ‘B’ On the inside of the enclosure. pull the ...

  • Kohler CFI230G - page 8

    8 21 Check glass is vertical. If not remove scr ews, re-drill and re-fit as r equired. Re-fit rubber strip over screws Drill 4 x 3mm holes through jamb into wall channel STEP 10 STEP 11 Fit 4 x screws B Ensure glass panel is vertical STEP 9 Slacken scr ews ‘ A ’ . Push the glass panel into the wall jamb. The glass should be 2mm lower than the t ...

  • Kohler CFI230G - page 9

    Drill 4 x 8mm holes Fit plugs Loosely fit 4 x screws A Carefully lift the panel back into postion Seal behind the wall channel and tighten screws A B A Spot drill through 4 fixing holes in the wall jamb and mark the wall. Only 4 of the 8 holes are using alternate sides ‘ A ’ . Carefully r emove the panel from the tray A B Adjust wall jamb until ...

  • Kohler CFI230G - page 10

    Measure the distance of the glass between the wall jamb and the tray ‘ A ’ . Cut the splashguard to size cutting at the wall jamb end. Fit the splashguard to the bottom of the glass 10 19 CFI2 30G STEP 19 STEP 20 If the any further adjustment is requir ed to make the glass panel vertical turn the 4 screws ‘D’ until the panel is in the corre ...

  • Kohler CFI230G - page 11

    Fit top cap - Water delivery side C C C Fit top cap - Non Water delivery side 18 CFI2 30G 11 CFI2 30G STEP 23 Check top rail is level. Draw ar ound parking block STEP 22 Note: The lintel is supplied as a RH unit. For L H versions loosen the panel clamps and turn them through 180 o Ensure glass panels are parallel to eac h other Loosely fit the park ...

  • Kohler CFI230G - page 12

    Support the weight of the column. Connect the water pipe to the connector from at the top of the column. Caution Support the weight of the column. Plug the electrical c able into the connector on the cable from the W ater Delivery System Caution 12 17 CFI2 30G Check the lintel is level. If adjustment is requir ed turn screw ‘ A ’ on the panel c ...

  • Kohler CFI230G - page 13

    Push top of column into jamb assembly until it locks in place PROCEE D T O STE P 4 7 Support the weight of the column. Connect the water pipe to the connector from at the top of the column. Plug the electrical c able into the connector from the W ater Delivery System at the top of the column. Caution Carefully lift the W ater Delivery System column ...

  • Kohler CFI230G - page 14

    Fit door retainers to both top roller brackets. Caps will ‘click’ and loc k in place Lift the glass door up and slide the rollers onto the lintel Caution Loosen the scr ew fixing the b ottom r oller to the glass with a 3mm allen key Locate other side of glass door panel between the roller and plastic glass guide Caution Whilst supporting the we ...

Manufacturer Kohler Category Outdoor Shower

Documents that we receive from a manufacturer of a Kohler CFI230G can be divided into several groups. They are, among others:
- Kohler technical drawings
- CFI230G manuals
- Kohler product data sheets
- information booklets
- or energy labels Kohler CFI230G
All of them are important, but the most important information from the point of view of use of the device are in the user manual Kohler CFI230G.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Kohler CFI230G, service manual, brief instructions and user manuals Kohler CFI230G. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Kohler CFI230G.

A complete manual for the device Kohler CFI230G, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Kohler CFI230G by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Kohler CFI230G.

A complete Kohler manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Kohler CFI230G - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Kohler CFI230G, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Kohler CFI230G, that we can find in the current document
3. Tips how to use the basic functions of the device Kohler CFI230G - which should help us in our first steps of using Kohler CFI230G
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Kohler CFI230G
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Kohler CFI230G in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Kohler CFI230G?

Use the form below

If you did not solve your problem by using a manual Kohler CFI230G, ask a question using the form below. If a user had a similar problem with Kohler CFI230G it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)