Manual Omega Engineering FPR 200

16 pages 0.34 mb
Download

Go to site of 16

Summary
  • Omega Engineering FPR 200 - page 1

    FPR 200 F lo w Sensor Flow Sensor with St ainless Steel Body Flow Sensor with Polypropylene Body User ’s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info ISO 9001 CERTIFIED CORPORATE QUALITY STAMFORD, CT ISO 9002 CERTIFIED CORPORATE QUALITY MANCHESTER, UK ...

  • Omega Engineering FPR 200 - page 2

    Servicing Nor th America: U.S.A.: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Canada: Sa ...

  • Omega Engineering FPR 200 - page 3

    Introduction This manual is a service guide produced by the manufacturer . The manual provides specific procedures and/or illustrations for installa- tion, inspection, cleaning and filtration of all Omega FPR 200 flow sensors. When properly followed, these procedures will keep your flow sensor operating dependably for many years. It is important fo ...

  • Omega Engineering FPR 200 - page 4

    Installation - Mec hanical 1. The flow sensor has NPT (National Pipe Thread) plumbing con- nections. It is recommended that a paste type pipe sealant be used on these threads. [T eflon tape sealant can be used as long as it is applied in such a way that it will not enter the flow stream. Pieces of T eflon t ape can wrap around the turbine and imped ...

  • Omega Engineering FPR 200 - page 5

    4. It is recommended that the sensor be placed in such a position that the round access cover can be removed for cleaning and tur- bine servicing. It is also recommended that a union be placed near the sensor to allow easy removal. Note1: The flow sensor is a bi-directional measuring device. References to “inlet” and “outlet” refer to uni-d ...

  • Omega Engineering FPR 200 - page 6

     Apply the DC supply voltage directly across the sensor wires. If the LED does illuminate, the load is either: too great of imped- ance or an open circuit. If the LED does not illuminate, the sen- sor's lead wires or circuit are defective. 6. The installation should be complete. Installation - Electronic (0-5V DC Output Only) 1. Connect the ...

  • Omega Engineering FPR 200 - page 7

    Installation - Electronic (Pulse Output Only) The flow sensor pulse output circuit is a three-wire DC-powered design that transmits a frequency proportional to flow rate. The circuit operates on 5-24 V DC and will consume a maximum of 25 mA from the power supply . 1. Connect the red wire (pin 1 for units with the electronic disconnect option) from ...

  • Omega Engineering FPR 200 - page 8

    Installation - Electronic (R elay Output Onl y) 1. Connect the red wire from the sensor to the positive terminal of the 12-35 V DC power supply . 2. Connect the black wire from the transmitter to the negative terminal of the 12-35 V DC power supply . 3. (Versions with st ainless steel sensor body only) Be sure to properly ground the flow sensor by ...

  • Omega Engineering FPR 200 - page 9

    Set P oint Adjustment (Relay Output Only) 1) Adjust the flow rate through the line in which the flow sensor is installed to the rate that corresponds to the desired relay trip point. 2) If the red LED on the back side of the sensor is not illuminated, use a small flat bladed screwdriver to slowly turn the adjustment screw on the set point potentiom ...

  • Omega Engineering FPR 200 - page 10

    1. Relieve pressure in the piping system. 2. Remove the retainer ring that secures the turbine access cover . 3. Remove the access cover with a pliers, taking care not to damage the o-ring seal. 4. Pull out the turbine assembly and the shaft. 5. Inspect the shaft for things that may have wrapped around it. 6. Inspect the turbine bearing surface for ...

  • Omega Engineering FPR 200 - page 11

    Mechanical Specifica tions FL OW SENSOR WITH ST AINLESS STEEL BOD Y Maximum pressure: 200 PSI clear cover , 500 PSI SS cover Maximum temperature: 225 º F Measuring range* 1/2" NPT Ported: 0.5 - 15 GPM 3/4" & 1" NPT Ported: 1.5 - 50 GPM Wetted materials: 316SS, acetal copolymer , Buna, PEEK and polycarbonate Non-wetted materials: ...

  • Omega Engineering FPR 200 - page 12

    ALL VERSIONS WITH 0-5 VDC CIR CUIT Power requirements: 12-35VDC, 20 mA Maximum Current: 30 mA DC Max. T rans. Distance: <200 feet recommended Min. Load Resistance: 1000 Ω Flow rate accuracy: 2% of full scale Repeatability: 0.5% of scale Resolution: infinite Response time: 2 seconds to 90% ALL VERSIONS WITH PULSE OUTPUT CIR CUIT Power requireme ...

  • Omega Engineering FPR 200 - page 13

    Dimension Drawings 1 Dimension with optional clear cover installed 2 Polypropylene version only DIM 1/2" NPTF Port s 3/4" & 1" NPTF Port s A 1.94" (49 mm) 3.06" (78 mm) B 1.13" (29 mm) 1.33" (34 mm) C 2.00" (51 mm) 2.46" (62 mm) D 2.45" (62 mm) 2.78" (71 mm) D 1 2.60" (66 mm) 2.88" ...

  • Omega Engineering FPR 200 - page 14

    NOTES: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ...

  • Omega Engineering FPR 200 - page 15

    WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers r ...

  • Omega Engineering FPR 200 - page 16

    Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, Controllers & ...

Manufacturer Omega Engineering Category Automobile Parts

Documents that we receive from a manufacturer of a Omega Engineering FPR 200 can be divided into several groups. They are, among others:
- Omega Engineering technical drawings
- FPR 200 manuals
- Omega Engineering product data sheets
- information booklets
- or energy labels Omega Engineering FPR 200
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega Engineering FPR 200.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega Engineering FPR 200, service manual, brief instructions and user manuals Omega Engineering FPR 200. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega Engineering FPR 200.

A complete manual for the device Omega Engineering FPR 200, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega Engineering FPR 200 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega Engineering FPR 200.

A complete Omega Engineering manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega Engineering FPR 200 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega Engineering FPR 200, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega Engineering FPR 200, that we can find in the current document
3. Tips how to use the basic functions of the device Omega Engineering FPR 200 - which should help us in our first steps of using Omega Engineering FPR 200
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega Engineering FPR 200
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega Engineering FPR 200 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega Engineering FPR 200?

Use the form below

If you did not solve your problem by using a manual Omega Engineering FPR 200, ask a question using the form below. If a user had a similar problem with Omega Engineering FPR 200 it is likely that he will want to share the way to solve it.

Copy the text from the picture