  • Liebert XDA - page 1

    Precision Cooling For Bu siness-Critical Con tinuit y Lieber t XDA ™ Air Flow Enhan c er User Manua l ...

  • Liebert XDA - page 2

    ...

  • Liebert XDA - page 3

    i TABLE OF CONTENTS 1.0 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Features & Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.0 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.1 Equipment Inspection . . . . . . . . . . . . . . . . . . ...

  • Liebert XDA - page 4

    ii ...

  • Liebert XDA - page 5

    1 1.0 P RODUCT D ESCRIPTION The Liebert XDA Air Flow E nhancer increases the airflow through densely populated enclosures, breaki ng up hot spots within the enclo- sure that can threaten the uptime of your critical systems. Equipment fans often prod uce insufficient f low to push air through the masses of data communication wiring at the re ar of t ...

  • Liebert XDA - page 6

    2 2.0 I NST ALLATION The Liebert XDA can be attached to most equi pment cabinet doors 60" tall or taller. The unit typical ly is installed on the outside of a cabi- net’s rear door, generally used to discharge heat generated from the cabinet. If aisle space is insufficien t for exterior mounting, and space is avail- able inside the cabinet, ...

  • Liebert XDA - page 7

    3 2.2.1 Required T ools • Phillips screwdriver • Pliers • Scissors 2.3 Mounting the XDA on the Exterior of the Rear Cabinet Door 2.3.1 P rep are to Ins t all the Un it 1. Determine the desired mount- ing position on the door. 2. Attach the mounting bracket to the top of the XDA, positioning the bracket to obtain the desired mounting height. 3 ...

  • Liebert XDA - page 8

    4 2.3.2 Mount the Unit and Att ach it to the Cabinet 1. Lift the unit with bracket attach ed and h ang it on the door, as shown at right. Ensure that the bracket rests safely on top of the top edge of door. 2. Move the unit sideways into the desired position. Ensu re that the unit does not interfere with operation of the door latch. 3. Place screws ...

  • Liebert XDA - page 9

    5 2.4 Mounting the XDA on the Interior of the Rear Cabinet Door 2.4.1 P rep are to Ins t all the Un it 1. Remove the s crews on the sides of the XDA that secure the mounting angles to the unit. 2. Remove the mounting angles. 3. Position the angles so their mounting surfaces are near the fron t of the XDA . (This is the air discharge side, which has ...

  • Liebert XDA - page 10

    6 2.4.2 Mount the Unit and Att ach It to the Cabinet 1. Lift the unit onto the door, plac ing the two mounting holes on the top end, over the two screws atta ched to the door and bracket. Place nuts on the screws to hold the unit in place. 2. On the middle a nd lower mounting holes, place screws through the door and then thro ugh the mounting angle ...

  • Liebert XDA - page 11

    7 3.0 P OWER C ONNECTIONS Connect the power cords to separate power sources (as specified in Specifications on page 9 ), to keep the XDA operating if there is a power failure on one circuit. Route the power cords under or over the cabinet as needed to the ne arest av ailable receptacles. If only one power source is a vailabl e, connect both power c ...

  • Liebert XDA - page 12

    8 4.0 O PERATION & M AINTENANCE The XDA is activated by turning on the ON/OFF switch on the bottom of the unit, near the power cords. All fans operate continuously to remove the maximum amount of heat from the cab- inet. If a power failure sh ould occur on the primary power source, the XDA will operate from the secondary source until the primar ...

  • Liebert XDA - page 13

    9 5.0 S PECIFICATIONS Nominal Capacity 1000 CFM @ 60Hz Dimensions W x D x H, in (mm) 8 x 2.25 x 56 (203.2 x 57.2 x 1422.4) Wei ght, lbs (kg) 25 (1 1.3) Electrical S pecifications 120V -1-50/60Hz 230V -1-50/60Hz Amp Draw 1.5 A @ 120V 0.8 A @ 230V ...

  • Liebert XDA - page 14

    10 ...

  • Liebert XDA - page 15

    ...

  • Liebert XDA - page 16

    Ensuring The High A v ailab ilit y 0f Mission-Critic al Dat a And Applic a tions. While every precaution has been tak en to ensure the accuracy and complete ness of this literature , Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from u se of this informa tion or for any errors or omissions . © 2006 ...

Manufacturer Liebert Category Air Cleaner

Documents that we receive from a manufacturer of a Liebert XDA can be divided into several groups. They are, among others:
- Liebert technical drawings
- XDA manuals
- Liebert product data sheets
- information booklets
- or energy labels Liebert XDA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Liebert XDA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Liebert XDA, service manual, brief instructions and user manuals Liebert XDA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Liebert XDA.

Similar manuals

A complete manual for the device Liebert XDA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Liebert XDA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Liebert XDA.

A complete Liebert manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Liebert XDA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Liebert XDA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Liebert XDA, that we can find in the current document
3. Tips how to use the basic functions of the device Liebert XDA - which should help us in our first steps of using Liebert XDA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Liebert XDA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Liebert XDA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Liebert XDA?

Use the form below

If you did not solve your problem by using a manual Liebert XDA, ask a question using the form below. If a user had a similar problem with Liebert XDA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)