  • Kidde 2508-7201-07 - page 1

    Combination Smoke and Car bon Monoxide Alarm Manual P/N 810-1512 Rev . N 2508-7201-07 For questions concerning your Smoke and Carbon Monoxide Alarm, please call our Consumer Hotline at 1-800-880-6788. User’ s Guide for Models KN-COSM-I and KN-COSM-IB • 120V AC • 9V Battery Backup (model KN-COSM-IB) • 2-LED Display • Peak Level Memory • ...

  • Kidde 2508-7201-07 - page 2

    Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1 Product View . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 2-3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 4-7 Installation Instructions Step 1: Installation Instructions: A. Recommended Installation Locations . . Pages 8-10 ...

  • Kidde 2508-7201-07 - page 3

    Thank you for purchasing the Kidde Combination Smoke and Carbon Monoxide Alarm model # KN-COSM-I or # KN-COSM-IB. This alarm is suitable as a Single Station and/or Multiple Station (24 devices) alarm. This alarm has a seven-year limited warranty . Please take a few minutes to thoroughly r ead this user’ s guide, and save for future r eference. T ...

  • Kidde 2508-7201-07 - page 4

    Product V iew FRONT 2 2508-7201-07(810-1512N):_ 2011.5.3 9:05 AM Page 4 ...

  • Kidde 2508-7201-07 - page 5

    Product V iew BACK 3 2508-7201-07(810-1512N):_ 2011.5.3 9:05 AM Page 5 ...

  • Kidde 2508-7201-07 - page 6

    • Loud 85 decibel alarm. • Permanent independent smoke and carbon monoxide sensors. • Smoke alarm takes precedence when both smoke and carbon monoxide are pr esent. • Powered by 120V AC (60 Hz, 25 mA max) wir e-in connector . Model KN-COSM-IB is also equipped with a 9V battery backup. • Model KN-COSM-IB is equipped with Battery Pull T ab ...

  • Kidde 2508-7201-07 - page 7

    • V oice Message System that alerts user to the following conditions: – System announces “HUSH MODE ACTIV A TED” when the unit is first put into HUSH Mode. – System announces “HUSH MODE CANCELLED” when unit resumes normal operation after Hush Mode has been cancelled. – System announces “CARBON MONOXIDE PREVIOUSL Y DETECTED” when ...

  • Kidde 2508-7201-07 - page 8

    • Seven (7) years after initial power up, this unit will “chirp” twice every 30 seconds. This is an “operational end of life” feature which will indicate that it is time to r eplace the alarm. Smoke Alarm The smoke alarm monitors the air for products of combustion that are pr oduced when something is bur ning or smoldering. When smoke par ...

  • Kidde 2508-7201-07 - page 9

    • AC powered alarms (without battery backup) will not operate if the AC power has been cut off, such as by an electrical fir e or an open fuse. • Smoke alarms must be tested regularly to make sur e the batteries and the alarm circuits ar e in good operating condition. • Smoke alarms cannot provide an alarm if smoke does not reach the alarm. T ...

  • Kidde 2508-7201-07 - page 10

    Step 1 Installation Guide: IMPORT ANT : THIS ALARM MUST BE MOUNTED ON A CEILING OR W ALL. IT WAS NOT DESIGNED FOR USE AS A T ABLETOP DEVICE! INST ALL ONL Y AS DET AILED! A. Recommended Installation Locations: Kidde Safety recommends the installation of a Smoke/CO Alarm in the following locations. For maximum protection we suggest an alarm be instal ...

  • Kidde 2508-7201-07 - page 11

    Sloped Ceiling Installation: The following information is from the National Fir e Protection Association and is listed in Fire Code 72. Install Smoke Alarms on sloped, peaked or cathedral ceilings at, or within 3 ft (0.9m) of the highest point (measured horizontally). NFP A 72 states “Smoke alarms in rooms with ceiling slopes greater than 1 ft to ...

  • Kidde 2508-7201-07 - page 12

    THIS EQUIPMENT SHOULD BE INST ALLED IN ACCORDANCE WITH THE NA TIONAL FIRE PROTECTION ASSOCIA TION’S ST ANDARD 72 (National Fire Pr otection Association, Batterymarch Park, Quincy , MA 02269). B. Where Not to Install: Do not install in garages, kitchens, furnace rooms or bathrooms! INST ALL A T LEAST 5 FEET AW A Y FROM ANY FUEL BURNING APPLIANCE. ...

  • Kidde 2508-7201-07 - page 13

    Step 2 Wiring Instructions: WIRING REQUIREMENTS • This smoke alarm should be installed on a U.L. listed or recognized junction box. All connections should be made by a qualified electrician and all wiring used shall be in accordance with articles 210 and 300.3(B) of the U.S. National Electrical Code ANSI/NFP A 70, NFP A 72 and/or any other codes ...

  • Kidde 2508-7201-07 - page 14

    • A maximum of 24 Kidde Safety devices may be interconnected in a multiple station arrangement. The interconnect system should not exceed the NFP A interconnect limit of 12 smoke alarms and/or 18 alarms total (smoke, CO, Smoke/ CO Combination, heat, etc.). This Smoke/CO combination alarm must be counted as a smoke alarm when determining the numbe ...

  • Kidde 2508-7201-07 - page 15

    Step 3 Mounting Instructions: CAUTION: YOUR SMOKE/CO ALARM IS SEALED AND THE COVER IS NOT REMOV ABLE! 1. T o help identify the date to replace the unit, a label has been affixed to the side of the alarm. W rite the “Replace by” date (7 years from initial power up) in permanent marker on the label. See Alarm Replacement section for additional in ...

  • Kidde 2508-7201-07 - page 16

    7. T ur n on the AC power . The gr een AC Power On Indicator should be lit when the alarm is operating from AC power . 8. T wo labels ar e included with your alarm. They have important information on what to do in case of an alarm. Add the phone number of your emergency service provider (Fir e Department or 911) in the space provided. Place one lab ...

  • Kidde 2508-7201-07 - page 17

    Interconnect Featur e Y our Combination Smoke/CO Alarm is inter connectable to other multiple station Kidde, Nighthawk and Kidde/Fyrnetics products: • When compatible smoke alarms and heat alarms ar e interconnected to your Smoke/CO Alarm, they will only respond to a smoke r elated event. • When mixing compatible models with battery backup with ...

  • Kidde 2508-7201-07 - page 18

    Operating Instructions 16 immediately , the unit will verbally announce “HUSH MODE ACTIV A TED”, and the green LED will flash every 2 seconds for approximately 10 minutes. This indicates that the smoke alarm is in a temporarily desensitized condition. Y our Smoke/CO Alarm will automatically reset after appr oximately 10 minutes. When the unit r ...

  • Kidde 2508-7201-07 - page 19

    Operating Instructions 17 LED Indicator Operation Red LED Red LED will flash in conjunction with the alarm beep. Therefor e, the red LED will flash during a smoke alarm, a CO alarm, a low battery mode chirp and a unit error mode chirp. Green LED The green LED will flash as described below under the following conditions: – Standby Condition (power ...

  • Kidde 2508-7201-07 - page 20

    NEVER IGNORE THE SOUND OF THE ALARM! Determining what type of alarm has sounded is easy with your Nighthawk Combination Smoke/CO Alarm. The voice message warning system will inform you of the type of situation occurring. Refer to the Features section on pages 4-7 for a detailed description of each alarm pattern. What T o Do If The Alarm Sounds When ...

  • Kidde 2508-7201-07 - page 21

    If the alarm sounds, check for fires first. If a fir e is discovered follow these steps. Become thoroughly familiar with these items, and review with all family members! • Alert small children in the home. • Leave immediately using one of your planned escape routes (see page 26). Every second counts, don’t stop to get dr essed or pick up valu ...

  • Kidde 2508-7201-07 - page 22

    What T o Do If The Alarm Sounds 20 When the carbon monoxide alarm sounds: If alarm signal sounds: 1) Operate the test/reset button 2) Call your emergency services (Fire Dept. or 911) 3) Immediately move to fresh air - outdoors or by an open door/window . Do a head count to check that all persons are accounted for . Do not reenter the premises nor m ...

  • Kidde 2508-7201-07 - page 23

    Alarm Removal and Battery Replacement 21 The CO sensor meets the alarm response time r equirements of UL standard 2034. Standar d alarm times are as follows: At 70 PPM, the unit must alarm within 60-240 minutes. At 150 PPM, the unit must alarm within 10-50 minutes. At 400 PPM, the unit must alarm within 4-15 minutes. This carbon monoxide alarm is d ...

  • Kidde 2508-7201-07 - page 24

    Alarm Removal and Battery Replacement 22 CAUTION: YOUR SMOKE/CO ALARM IS SEALED AND THE COVER IS NOT REMOV ABLE! T o replace the battery you must first remove the alarm from the mounting bracket by following the ALARM REMOV AL instructions at the beginning of this section. After the alarm has been removed, you can open the battery door and r eplace ...

  • Kidde 2508-7201-07 - page 25

    General Maintenance 23 W ARNING! Use only the batteries specified. Use of dif ferent batteries may have a detrimental effect on the Smoke/CO alarm. A good safety measure is to r eplace the battery at least once a year , or at the same time yo change your clocks for daylight saving time. Alarm Replacement Seven years after initial power -up, this un ...

  • Kidde 2508-7201-07 - page 26

    24 General Maintenance Storing the unit in a plastic bag during any of the above projects will protect the sensors fr om damage. Do not place near a diaper pail. W ARNING: Reinstall the Smoke/CO Alarm as soon as possible to assure continuous pr otection. When household cleaning supplies or similar contaminates are used, the area must be well ventil ...

  • Kidde 2508-7201-07 - page 27

    Carbon Monoxide Safety Information 25 pipes (cold/humid air with extended periods between cycles), negative pressur e differential resulting fr om the use of exhaust fans, simultaneous operation of several fuel-burning appliances competing for limited internal air , vent pipe connections vibrating loose from clothes dryers, furnaces, or water heate ...

  • Kidde 2508-7201-07 - page 28

    26 Carbon Monoxide Safety Information 1. Mild Exposure: Slight headache, nausea,vomiting, fatigue (often described as “Flu-like” symptoms). 2. Medium Exposure: Severe throbbing headache, drowsiness, confusion, fast heart rate. 3. Extreme Exposur e: Unconsciousness, convulsions, cardior espiratory failure, death. The above levels of exposure r e ...

  • Kidde 2508-7201-07 - page 29

    Fire Safety Information 27 Fire Pr evention Never smoke in bed, or leave cooking food unattended. T each children never to play with matches or lighters! T rain everyone in the home to recognize the alarm pattern, voice message warning and to leave the home using their escape plan when it’ s heard. Know how to do “Stop, Drop and Roll” if clot ...

  • Kidde 2508-7201-07 - page 30

    Industry Safety Standards 28 areas pr otected by the required smoke alarms. For this reason, it is recommended that the householder consider the use of additional smoke alarms for those areas for incr eased protection. The additional areas include the basement, bedr ooms, dining room, furnace room, utility r oom, and hallways not protected by the r ...

  • Kidde 2508-7201-07 - page 31

    W arranty and Service Information 29 Limited W arranty SEVEN YEAR LIMITED WARRANTY KIDDE warrants that the enclosed alarm (but not the battery) will be free fr om defects in material and workmanship or design under normal use and service for a period of seven years from the date of purchase. The obligation of KIDDE under this warranty is limited to ...

  • Kidde 2508-7201-07 - page 32

    W arranty and Service Information 30 The above warranty may not be altered except in writing signed by both parties hereto. Y our Nighthawk Combination Smoke & CO Alarm is not a substitute for property , fire, disability , life or other insurance of any kind. Appropriate insurance coverage is your r esponsibility . Consult your insurance agent. ...

  • Kidde 2508-7201-07 - page 33

    QUESTIONS OR FOR MORE INFORMA TION Call our Consumer Hotline at 1-800-880-6788 or contact us at our website at www .kidde.com Kidde 1016 Corporate Park Drive, Mebane, NC 27302 Custom Assembled in China with U.S. and Foreign Components 2508-7201-07(810-1512N):_ 2011.5.3 9:05 AM Page 33 ...

Manufacturer Kidde Category Carbon Monoxide Alarm

Documents that we receive from a manufacturer of a Kidde 2508-7201-07 can be divided into several groups. They are, among others:
- Kidde technical drawings
- 2508-7201-07 manuals
- Kidde product data sheets
- information booklets
- or energy labels Kidde 2508-7201-07
All of them are important, but the most important information from the point of view of use of the device are in the user manual Kidde 2508-7201-07.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Kidde 2508-7201-07, service manual, brief instructions and user manuals Kidde 2508-7201-07. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Kidde 2508-7201-07.

Similar manuals

A complete manual for the device Kidde 2508-7201-07, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Kidde 2508-7201-07 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Kidde 2508-7201-07.

A complete Kidde manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Kidde 2508-7201-07 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Kidde 2508-7201-07, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Kidde 2508-7201-07, that we can find in the current document
3. Tips how to use the basic functions of the device Kidde 2508-7201-07 - which should help us in our first steps of using Kidde 2508-7201-07
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Kidde 2508-7201-07
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Kidde 2508-7201-07 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Kidde 2508-7201-07?

Use the form below

If you did not solve your problem by using a manual Kidde 2508-7201-07, ask a question using the form below. If a user had a similar problem with Kidde 2508-7201-07 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)