Manual Emerson 1000

32 pages 1.58 mb
Download

Go to site of 32

Summary
  • Emerson 1000 - page 1

    AC P ow er For Business-Criti cal C on tinuity™ Li eber t ® PSI XR ™ Us er Man ual–1000/1500/2200/3000 , 120V A C ...

  • Emerson 1000 - page 2

    ...

  • Emerson 1000 - page 3

    i T ABLE OF CONTENTS I MPORT ANT S AFETY I NSTRUCTION S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 G LOSSARY OF S YMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.0 I NTRODUCTI ON . . . . . . . . . . . . . . . . . . . . . ...

  • Emerson 1000 - page 4

    ii 6.0 C OMMUNICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 6.1 DB-9 Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 6.2 Remote Shutdown Via the DB-9 Connector . . . . . . . . . . . . . . . ...

  • Emerson 1000 - page 5

    1 I MPORT A NT S AFETY I NSTRUCTIONS SA VE THESE INSTRUCTIONS This manual co ntains important instructio ns that should be followed du ring installation and ma inte- nance of the UPS. • Intended for installat ion in a temperature-co ntrolled, indoor area free of conductive contaminants. • Maximum ambient temperature 104°F (40°C). Read this ma ...

  • Emerson 1000 - page 6

    2 CONDITIONS OF USE —The input supply outlet must be with in 6 ft. (1.8m) of the UPS and be eas- ily accessed. This UPS provides conditioned powe r to connected equipment. It is no t intended for use w ith life-sup- port and other designated “critica l” devices. Maximum load must no t exceed that shown on the UPS rating label. If uncertain, c ...

  • Emerson 1000 - page 7

    3 G LOSSARY OF S YMBOLS Risk of ele ctrical shock Indicates caution followed by important instructions Indicates the unit contains a valve-regulated, lead-ac id battery Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage ON/Alarm Silence/Manual Self-Diagnostic Test OFF Status Change Button ! ...

  • Emerson 1000 - page 8

    Introd uction 4 1.0 I NTRODUCTION The Liebert PSI ™ XR is a 2U, line-interactive UPS that may be installed in a rack or used as a tower UPS. Status indicators on the front of the Liebert PSI XR display load level, battery level, buck/boost, site- wiring fault, overload, battery status and UPS op eration. Controls in clude a combination On/Alarm S ...

  • Emerson 1000 - page 9

    Introd uction 5 Figure 3 2200—rear view Figure 4 3000—rear view DC 48V OUTPUT EPO INPUT VOLT AGE=110V VOLT AGE=120V VOLT AGE=127V 2 1 FUNCTION Network Surge Protection USB Port DB-9 Port (Conta ct Closure) Power Cord; 5-20P (not shown for cla rity) EPO External Battery Cabinet Conn ector V olt age Configur ation DIP Switch 15A Output Circuit Br ...

  • Emerson 1000 - page 10

    What’ s Included 6 2.0 W HAT ’ S I NCLUDED The Liebert PSI XR is shipped with the following items: • Multi-Language User Manual on CD • Liebert MultiLink Software and User Manu al, downloadable at multilink.liebert.com • Contact Closure (ML9P9S) Cable • USB Cable • Tower Stands • Mounting Hardware • Rack-Mou nt Handles • Fixed M ...

  • Emerson 1000 - page 11

    Installation 7 3.0 I NST ALLATION 3.1 Prep aration The Liebert PSI XR may be installe d in either a tower or rack conf iguration. Determine the method that suits the applica tion and proceed. Decide where to install the Liebert PSI X R. The UPS must be installed indoor s in a controlled envi- ronment. Place it in an area with unrestricted ai rflow ...

  • Emerson 1000 - page 12

    Installation 8 3.2 T ower UPS Installation See Figure 7 when using the Liebert PSI XR in a tower configuration. Figure 7 T ower conf iguration—att ach T ower S tands Step 1 Step 2 ...

  • Emerson 1000 - page 13

    Installation 9 3.3 Rack-Mount U PS Conversion and Inst allation See Fi gure 8 when installing the Liebert PSI XR in a rack. Ex ternal battery cabinets are inst alled in same manner. Figure 8 Convert the Liebert PSI XR f or rack inst allation NOTICE When rack-mounted, the UPS must be supported by a shelf, slide rails, brackets or fixed rails on each ...

  • Emerson 1000 - page 14

    Installation 10 3.4 Orient Display for Inst allation The Liebert PSI XR features a rotating display th at may be oriented for either tower or rack installations. To set the display for your instal lation, pu ll out on the display and rotate it un til it is orient ed correctly, then press it i nto the UPS until it is seated. Figure 9 Orienti ng the ...

  • Emerson 1000 - page 15

    Installation 11 3.7 Connect Network Surge protection Connect a 10 base-T/100 network cable to the networ k surge protection IN jack on the rear of the UPS. Connect from the OUT jack with ne twork cabling to network equipment (see Figure 11 ). Figure 1 1 Connect network surge prot ection 3.8 Connect Communication Interface Determine what type of com ...

  • Emerson 1000 - page 16

    Installation 12 3.9 Set Up Liebert MultiLink sof tware To start using Liebert MultiLink (sof tware and user ma nual availa ble at multilink.liebert.com ): • Install th e software. See the Liebert MultiLink quick-start guide or user manual for installation instructions. • Connect one end of the USB cable (supplied) to the USB port o n the rear o ...

  • Emerson 1000 - page 17

    Installation 13 3.1 1 External Battery Cabinet Inst allatio n Optional Liebert external battery cabinets may be connec ted to the UPS to prov ide additional battery run time. External battery cabinets are designed to be pla ced all on one side of the UPS or stacked beneath the UPS. The batteries have a maximu m run time of three hours at full load. ...

  • Emerson 1000 - page 18

    Installation 14 Figure 15 Connect battery cabinet s to UPS See Table 8 for approx imate battery run times. DC 24V OUTPUT INPUT EPO VOLTAGE=1 10V VOLTAGE=120V VOLTAGE=127V 2 1 FUNCTION ...

  • Emerson 1000 - page 19

    Controls and Indica tors 15 4.0 C ONTROLS AND I NDICATORS Buttons on the front panel displa y control the Lieb ert PSI XR. Eight L EDs indica te the UPS’s statu s. Refer to Figure 16 and Table 2 . Figure 16 Display and st atus indicators T able 2 Display and st atus indicators function, legend Item Name Status Indicators Description 1 LED 1 AVR B ...

  • Emerson 1000 - page 20

    Controls and Indica tors 16 4.1 Control Buttons 4.1.1 On/Alarm Silence/Manual Self-Diagnostic T est This button controls output power to co nnected load (s). It has three functions: •O n •A l a r m S i l e n c e • Manual Self-D iagnostic Test ON —Start the UPS by pressing this button for more than 3 seconds, then releasing the button (an al ...

  • Emerson 1000 - page 21

    Controls and Indica tors 17 4.2.3 Battery Level Indicator The five LEDs illuminate with a steady glow to indicate battery capacity. Battery capacity is shown for five second s after the Status Change button is pressed. The LEDs show the battery capacity as a range, ± 5% The LEDs’ battery level meanings and colors are: 4.2.4 UPS St atus Indicator ...

  • Emerson 1000 - page 22

    Operational Modes 18 5.0 O PERATIONAL M ODES 5.1 Normal Mode When the UPS is in Normal Mode, the No rmal Mode Indicato r illumina tes green. 5.2 Buck/Boost Mode The Automatic Voltage Regulator (AVR ) circuitry compensates for fluctu ations in utility power, su ch as voltage surges and sags. When the Liebert PSI XR detects an abnormality, it raises ...

  • Emerson 1000 - page 23

    Communication 19 6.0 C OMMUNICATION 6.1 DB-9 Connector The UPS has a DB-9 (9 pin female) connector on the rear to allow UPS statu s communications with a computer running Liebert MultiLink software in co ntact closure mode. The conne ction provides On Battery and Low Battery notification. When power is interrupted and battery power is low, Liebert ...

  • Emerson 1000 - page 24

    Communication 20 6.4 UPS Communications The Liebert PSI XR is equipped with a Liebert In telliSlot port to provid e advanced communication and monitoring options. Liebert MultiLink software continua lly monitors the UPS and can shut down your computer or server via USB, contact closure and SNMP (via IS-WEBRT3 card) in the ev ent of an extended powe ...

  • Emerson 1000 - page 25

    Battery Maintenance 21 7.0 B ATTERY M AINTENANCE 7.1 Battery Charging, S torage The batteries are valve-regulated, nonspillabl e, lead acid and must be kept charged to retain their design life . The Liebert PSI XR con tinuously charg es the batteries wh en connected to th e utility sup- ply, even while the UPS is switched Off. If the Liebert PSI XR ...

  • Emerson 1000 - page 26

    Specifications 22 8.0 S PECIFICATIONS T able 6 Liebert PSI XR specifications Model Number PS1000RT3-120XR PS1000RT3120XRW PS1500RT3-120XR PS1500RT3120XRW PS2200RT3-120XR PS2200RT3120XRW PS3000RT3-120XR PS3000RT3120XRW Power Rating, VA/W 1000VA/900W 1500VA/13 50W 1920VA/1920W * 3000VA/270 0W Dimensions, W x D x H, in (mm) Unit 17.3 x 19.3 x 3.5 (440 ...

  • Emerson 1000 - page 27

    Specifications 23 T able 7 Battery cabinet specifica tions Model Number PSRT3-24VBXR PSRT3-48VBXR Used w/UPS Model PS1000RT3-120XR PS1000RT3120XRW PS1500RT3-120XR PS1500RT3120XRW PS2200RT3-120XR PS2200RT3120XRW PS3000RT3-120XR PS3000RT3120XRW Dimensions, W x D x H, in (mm) Unit 17.3 x 19.3 x 3.5 (440 x 490.5 x 88) Shipping 22 x 26.6 x 9 (560 x 675 ...

  • Emerson 1000 - page 28

    Specifications 24 T able 8 Liebert PSI XR battery run times Number of Batteries Load % 1000 1500 2200 3000 Internal Battery 10 83 82 76 75 20 52 48 48 47 30 31 28 28 28 40 18 17 17 17 50 15 13 14 13 60 12 11 11 11 70 11 9 9 9 8 0 9787 9 0 7676 1 0 0 6555 Internal battery + 1 External Battery Cabinets 10 263 222 161 1 43 20 165 131 101 83 30 120 93 ...

  • Emerson 1000 - page 29

    Specifications 25 Internal battery + 4 External Battery Cabinets 10 790 627 483 3 30 20 494 371 303 2 04 30 360 264 221 1 48 40 283 204 174 1 16 50 233 167 143 95 60 198 141 122 76 70 172 122 106 66 80 152 108 94 59 90 137 96 79 52 100 124 82 72 48 Internal battery + 5 External Battery Cabinets 10 965 762 564 3 92 20 605 452 354 2 43 30 440 320 258 ...

  • Emerson 1000 - page 30

    Trou bleshooting 26 9.0 T ROUBLESHOOTING The informatio n below indicates va rious symptoms a user may encoun ter if the Liebert PSI XR expe- riences a problem. See Table 9 for suggested solutions. 1. An alarm sounds, alerting that the UPS requires attention. The al arm can be silenced except for low battery, overload warning an d fault. 2. One or ...

  • Emerson 1000 - page 31

    ...

  • Emerson 1000 - page 32

    EmersonNetworkPower.com Ensuring The Hi gh Av ailab ilit y Of Mission-Critic al Data And Ap plic ations. Emerson Net work P ower , the global leader in enabling business-critical continuity , ensures network resilienc y and adaptability through a family of technologies—inc luding Liebert power and cooling technologies—that prot ect and suppor t ...

Manufacturer Emerson Category Power Supply

Documents that we receive from a manufacturer of a Emerson 1000 can be divided into several groups. They are, among others:
- Emerson technical drawings
- 1000 manuals
- Emerson product data sheets
- information booklets
- or energy labels Emerson 1000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson 1000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson 1000, service manual, brief instructions and user manuals Emerson 1000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson 1000.

Similar manuals

A complete manual for the device Emerson 1000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson 1000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson 1000.

A complete Emerson manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson 1000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson 1000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson 1000, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson 1000 - which should help us in our first steps of using Emerson 1000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson 1000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emerson 1000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emerson 1000?

Use the form below

If you did not solve your problem by using a manual Emerson 1000, ask a question using the form below. If a user had a similar problem with Emerson 1000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)