Manual Omega OS137

20 pages 0.65 mb
Download

Go to site of 20

Summary
  • Omega OS137 - page 1

    OS137 SERIES Miniature Non-Contact Infrared T emperature Sensor/T ransmitter MADE IN omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide Shop online at CA UTION! – This product is not intended for medical use or use on humans ...

  • Omega OS137 - page 2

    Servicing Nor th America: U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 USA Toll Free: 1-800-826-6342 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec), Canada H7L 5A1 Toll-Free: 1-800-826-6342 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: ...

  • Omega OS137 - page 3

    i OS137 Series Miniature Non-Contact Infrared T emperature Sensor/T ransmitter T able of Contents Section Page Caution & Safety Information ...................................................................... iii Safety W arnings and IEC Symbols .............................................................. iii Section 1 Introduction ........ ...

  • Omega OS137 - page 4

    OS137 Series Miniature Non-Contact Infrared Temperature Sensor/Transmitter ii T able of Figures Figure Description Page 2-1 General W iring Diagram ................................................................ 2 2-2 Alarm Output W iring Diagram .................................................... 2 3-1 Optical Field of V iew .................... ...

  • Omega OS137 - page 5

    OS137 Series Miniature Non-Contact Infrared Temperature Sensor/Transmitter iii CAUTION & SAFETY INFORMA TION If the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impair ed. The Installation category is one (1). There is no user r eplaceable fuse in this product. The output terminals ...

  • Omega OS137 - page 6

    1 SECTION 1 - INTRODUCTION The OS137 Series is a precision, miniatur e infrared transmitter . It measures temperature via non-contact, and pr ovides an analog output proportional to the measured temperatur e. The OS137 Series is offer ed in three temperatur e ranges: 0 to 100ºC (32 to 212ºF), -18 to 260ºC (0 to 500ºF) and -18 to 538ºC (0 to 10 ...

  • Omega OS137 - page 7

    2 2 - ** means: -MA : 4 to 20 mA current output -V1 : 0 to 5 Vdc output -V2 : 0 to 10 Vdc output -K : K type thermocouple output -MVC : 10 mV/ºC output -MVF : 10 mV/ºF output The following table lists the optional accessories: 2.2 – Electrical Connection The shielded cable provides the power and output connections. Fig 2-1 shows the wiring diag ...

  • Omega OS137 - page 8

    3 Operation 3 SECTION 3 – OPERA TION 3.1 – Measuring T emperature Before starting to measur e temperature, make sur e the following check list is met:  The power and output connections are made (Fig 2-1).  The target is lar ger than the optical field of view of the transmitter (Fig 3-1).  Use the Laser Sighting accessory (optional), to ...

  • Omega OS137 - page 9

    Operation 3 4 3.2 – Ambient T emperature The transmitter can operate in an ambient temperature of 0 to 70°C (32 to 158°F) without any water cool jacket. It can operate from 0 to 200°C (32 to 392°F) with the water cool jacket accessory , OS137-WC (Fig 3-6 & 3-7). It can operate up to 1 10°C (230°F) with air cooling. There is a warm up pe ...

  • Omega OS137 - page 10

    Figure 3-4. Air Purge Collar, OS137-AP Figure 3-5. Stainless Steel Housing Figure 3-6. Water/Air Cool Jacket, OS137-WC Operation 3 5 LIGHT DIAMOND KNURL 2.5 (0.1) WIDE DIMENSIONS mm (in) 1-20 UNEF 127 (5.0) 1.83 m (6 ft) 42.4 (1.67) 25.4 (1.0) DIMENSIONS mm (in) 128.6 (5.062) 7.9 (0.312) 41.2 (1.625) 1-20 UNEF 9.5 (3/8) 1-20 UNEF BUIL T -IN AIR PUR ...

  • Omega OS137 - page 11

    3.4 Alarm Setting The unit provides 0-100% alarm setpoint adjustment. Her e is an example of an alarm setting: • An OS137-3-MA (4/20 mA output), the alarm is to be set at 204°C (400°F) temperature. • Connect the alarm output as shown in Fig. 2-2. • Remove the End Cap to get to the Alarm Switch and the Alarm Adjust (Fig. 3-2). • Set the Sl ...

  • Omega OS137 - page 12

    SECTION 4 - LASER SIGHT ACCESSOR Y 4.1 – W arnings and Caution Y ou may receive harmful laser radiation exposure if you do not adhere to the warnings listed below: • USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED IN THIS GUIDE MA Y RESUL T IN HAZARDOUS RADIA TION EXPOSURE. • DO NOT LOOK A T THE LASER BE ...

  • Omega OS137 - page 13

    8 Figure 4-1. Laser Sighting Accessory, OS137-LS Figure 4-2. Laser Warning Label LASER W ARNING LABEL DC POWER JACK LED LASER POWER INDICA TOR LASER BEAM 22.2 (0.875) 50.8 (2.0) 38.1 (1.5) POWER CABLE ON/OFF SWITCH BA TTERY P ACK POWER SUPPL Y OS137 Dimensions mm (in) OUTPUT <1 mW, WAVELENGTH 630-670 nm, CLASS II (2) LASER PRODUCT. COMPLIES WITH ...

  • Omega OS137 - page 14

    9 SECTION 5 – SPECIFICA TIONS 5.1 - General T emperature Range: OS137-1 0 to 100ºC (32 to 212ºF) OS137-2 -18 to 260ºC (0 to 500ºF) OS137-3 -18 to 538°C (0 to 1000°F) Accuracy: @22ºC (72ºF) ambient 1.5% of Rdg or 2.0ºC (3.5ºF) whichever is greater Emissivity of 0.95 or greater Repeatability: 1% of Rdg or 1.0ºC (2.0ºF) whichever is grea ...

  • Omega OS137 - page 15

    10 5.2 - Laser Sight Accessory Laser W avelength (Color): 630 - 670 nm (red) Operating Distance: Up to 9.1 m (30 ft) Max. Laser Power Output: Less than 1 mW @ 22ºC (72°F) ambient European Classification: Class 2, EN60825-1/1 1.2001 FDA Classification: Class II Laser Product. Complies with 21 CFR 1040.10 Laser Beam Diameter: Less than 5 mm Beam Di ...

  • Omega OS137 - page 16

    Emissivity T able 6 11 Material Emissivity ( ε ) Aluminum – pure highly polished plate . . . . . . . . . . . . . . . . . . . . . . . . 0.04 to 0.06 Aluminum – heavily oxidized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.20 to 0.31 Aluminum – commercial sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Omega OS137 - page 17

    Emissivity Table 6 12 Material Emissivity ( ε ) Asbestos Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.96 Asphalt, tar , pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.95 to 1.00 Brick – red and rough . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Omega OS137 - page 18

    OS137 Series Miniature Non-Contact Infrared Temperature Sensor/Transmitter 6 13 NOTES: ...

  • Omega OS137 - page 19

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from dat e o f p urch ase . OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s ...

  • Omega OS137 - page 20

    M4015/0108 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com SM TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, Co ...

Manufacturer Omega Category Smoke Alarm

Documents that we receive from a manufacturer of a Omega OS137 can be divided into several groups. They are, among others:
- Omega technical drawings
- OS137 manuals
- Omega product data sheets
- information booklets
- or energy labels Omega OS137
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega OS137.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega OS137, service manual, brief instructions and user manuals Omega OS137. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega OS137.

Similar manuals

A complete manual for the device Omega OS137, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega OS137 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega OS137.

A complete Omega manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega OS137 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega OS137, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega OS137, that we can find in the current document
3. Tips how to use the basic functions of the device Omega OS137 - which should help us in our first steps of using Omega OS137
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega OS137
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega OS137 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega OS137?

Use the form below

If you did not solve your problem by using a manual Omega OS137, ask a question using the form below. If a user had a similar problem with Omega OS137 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)