Manual Pelco FR85011A

32 pages 0.78 mb
Download

Go to site of 32

Summary
  • Pelco FR85011A - page 1

    ® INST ALLA TION FT85011A/FR85011A Fiber T ransmitter and Receiver Single-Channel Digitally Encoded V ideo with Bidirectional Data C2604M (7/06) C2604M.book Page 1 Friday, July 14, 2006 1:08 PM ...

  • Pelco FR85011A - page 2

    C2604M.book Page 2 Friday, July 14, 2006 1:08 PM ...

  • Pelco FR85011A - page 3

    C2604M (7/06) 3 Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Product Overview . . . . . . . . . . . . . . . . . . ...

  • Pelco FR85011A - page 4

    4 C2604M (7/06) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near ...

  • Pelco FR85011A - page 5

    C2604M (7/06) 5 The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. CAUTION: RISK OF ELECTRIC SHOCK. DO NO ...

  • Pelco FR85011A - page 6

    6 C2604M (7/06) Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This ...

  • Pelco FR85011A - page 7

    C2604M (7/06) 7 Product Overview DESCRIPTION The FT85011A/FR85011A fiber transmitter and receiver provide the ability to transmit one unidirectional composite video channel and one bidirectional data channel over one optical fi ber . In addition, patent- pending technology provides the solution for allowing Coaxitro n ® pan/tilt/zoom (PTZ) contr ...

  • Pelco FR85011A - page 8

    8 C2604M (7/06) • Meets NEMA TS 2 and Caltrans traffi c signal control equipment standards for ambient operating temperature, mechanical shock and vibration, humidity with condensation, high-line/low-line voltage conditions, and transient voltage protection NOTE: Conformal coating is required for operation in environments with relative humidity ...

  • Pelco FR85011A - page 9

    C2604M (7/06) 9 MODELS The FT85011A/FR85011A fi ber transmitter and receiver consist of the following series of models : Multimode Models:* FT85011AMSTR Single-channel fiber optic video transmitter/data transceiver; multimode, ST connector FR85011AMSTR Single-channel fiber optic video receiver/data transceiver; multimode, ST connector Single-Mod ...

  • Pelco FR85011A - page 10

    10 C2604M (7/06) FRONT PANEL The front panel of the FT85011A transmitter and the FR85011A receiver provides LED indicators that allow you to monitor data activity, signal status, laser status, and operating power (refer to Figure 2). Figure 2. Front Panel of FT85011A T ransmitter and FR85011A Receive r For detailed information about the front-panel ...

  • Pelco FR85011A - page 11

    C2604M (7/06) 11 REAR PANEL All connections to the FT85011A transmitter and the FR85011A receiver are made to the rear panel of the modules (refer to Figure 3). Figure 3. Rear Panel of FT85011A T ransmitter and FR85011A Receive r For additional information about rear-panel connections and about the Data Selection switch, refer to the Installation s ...

  • Pelco FR85011A - page 12

    12 C2604M (7/06) Installation PACKAGE CONTENTS The following items are supplied: 1 FT85011A transmitter or FR85011A receiver 1 Regulated switching power supply with four plug adapters (North American, Australian, U.K., and European configurations); 100-240 VAC, 50-60 Hz input, 12 VDC output 1W all clip with two 4-40 x 0.250-inch Phillips pan head ...

  • Pelco FR85011A - page 13

    C2604M (7/06) 13 With the FT85011A transmitter/FR85011A receiver powered off, set the Data Selection switch to the required data communication using a small screwdriver. Refer to T able A for data communication switch settings. T able A. Data Communication Switch Settings Note the following: • The FT85011A transmitter/FR85011A receiver allows dat ...

  • Pelco FR85011A - page 14

    14 C2604M (7/06) MOUNTING The FT85011A transmitter/FR85011A receiver can be mounted into a rack or can be used as a stan d- alone module. As a stand -alone module, the unit can be placed on a desktop or can be mounted to a wall. NOTE: As a matter of convenience, it is recommended that you set the desired data communication before mounting the FT850 ...

  • Pelco FR85011A - page 15

    C2604M (7/06) 15 Mounting the T ransmitter/Receiver Using the W all Clip NOTE: Before mounting the FT85011A transmitter/FR85011A receiver to a wall, ensure that there is adequate space at both ends for viewing the front-panel LEDs and for m aking the various rear-panel cable connections. To attach the FT85011A transmitter/FR85011A receiver to a wal ...

  • Pelco FR85011A - page 16

    16 C2604M (7/06) CONNECTIONS Connections to the FT85011A transmitter and the FR85011A receiver are made on the rear panel of the modules and consist of the following: • Power connection NOTES: – A 12 VDC or 24 VAC power supply can be used to power the transmitter/receiver when used as a stand-alone module. A 12 VDC power supply is provided. If ...

  • Pelco FR85011A - page 17

    C2604M (7/06) 17 T able B. Data Connector Pin Assignments Pin Number RS-232 RS-422 RS-485 2-Wire RS-485 4-Wire Manchester Bi-Phase 1— TX+ (Out+) T+/R+ (Out+/In+) TX+ (Out+) — — 2— TX- (Out-) T -/R- (Out-/In-) TX- (Out-) — — 3— RX+ (In+) — RX+ (In+) RX+ (In+) (W) RX+ (In+) 4— RX- (In-) — RX- (In-) RX- (In-) (B) RX- (In-) 5 RX (In ...

  • Pelco FR85011A - page 18

    18 C2604M (7/06) Figure 7. RS-232 Data Communication Wiring RS-232 DA T A SELECTION RS-232 DA T A CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIVER FR85011A RECEIVER – DA T A CONNECTOR 1 2 3 4 5 RX (DA T A IN) (DA T A OUT) 6 TX RX (DA T A IN) (DA T A OUT) TX 7 8 GND DEVICE A FT85011A TRANSMITTER – DA T A CONNECTOR RS-232 DA T A SELECTION RS-23 ...

  • Pelco FR85011A - page 19

    C2604M (7/06) 19 Figure 8. RS-422 Data Communication Wiring RS-422 DA T A SELECTION RS-422 DA T A CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIVER 1 TX+ (DA T A OUT+) (DA T A OUT -) (DA T A IN+) (DA T A IN-) (DA T A OUT+) (DA T A OUT -) (DA T A IN+) (DA T A IN-) 2 TX- 3 RX+ 4 RX- 5 6 7 8 GND RX+ RX- TX+ TX- FT85011A TRANSMITTER – DA T A CONNECT ...

  • Pelco FR85011A - page 20

    20 C2604M (7/06) Figure 9. RS-485 2-Wire (Half Duplex) Data Communication Wiring RS-485 2-WIRE DA T A SELECTION RS-485 2-WIRE DA T A CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIVER FR RECEIVER – DA T A CONNECTOR 85011A 3 4 5 6 7 8 GND R+/T+ R-/T - DEVICE A RS-485 2-WIRE DA T A CONNECTIONS BETWEEN DEVICE B AND FT85011A TRANSMITTER FT TRANSMITTE ...

  • Pelco FR85011A - page 21

    C2604M (7/06) 21 Figure 10. RS-485 4-Wire (Full Duplex) Data Communication Wiring RS-485 4-WIRE DA T A SELECTION RS-485 4-WIRE DA T A CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIVER FR85011A RECEIVER – DA T A CONNECTOR 1 TX+ 2 TX- 3 RX+ 4 RX- (DA T A OUT+) (DA T A OUT -) (DA T A IN+) (DA T A IN-) (DA T A OUT+) (DA T A OUT -) (DA T A IN+) (DA T ...

  • Pelco FR85011A - page 22

    22 C2604M (7/06) Figure 11. Manchester Data Communication Wiring MANCHESTER MANCHESTER DA T A SELECTION MANCHESTER DA T A CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIVER FR85011A RECEIVER – DA T A CONNECTOR 1 2 3 RX+ (DA T A IN+) 4 RX- (DA T A IN -) 5 6 7 8 GND W* B* DEVICE A MANCHESTER DA T A CONNECTIONS BETWEEN DEVICE B AND FT85011A TRANSMIT ...

  • Pelco FR85011A - page 23

    C2604M (7/06) 23 Figure 12. Bi-Phase Data Communication Wiring BI-PHASE DA T A CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIVER BI-PHASE DA T A CONNECTIONS BETWEEN DEVICE B AND FT85011A TRANSMITTER FT TRANSMITTER – DA T A CONNECTOR 85011A DEVICE B BI-PHASE DA T A SELECTION 1 2 3 4 5 6 7 TX+ A T (D A OUT+) 8 TX- A T (D A OUT -) AT (D A IN+) AT ( ...

  • Pelco FR85011A - page 24

    24 C2604M (7/06) T roubleshooting LED indicators on the front panel of the FT85011A transmitter/FR85011A receiver (refer to Figure 2) allow you to monitor signal status, laser status, data activity , and operating power . T able C provides information about the front-panel indicators and associated troubleshooting guidelines . T able C. T roublesho ...

  • Pelco FR85011A - page 25

    C2604M (7/06) 25 Optic Fault LED Green The optical signal is being received and laser is operating properly . — No action required. Red The optical signal is not being received. Remote fiber module i s not powered on. Check power connections. Replace power supply if necessary . Fiber optic cable is not connected. Check fiber optic connections. ...

  • Pelco FR85011A - page 26

    26 C2604M (7/06) Data Tx LED Flashing amber Data is being trans- mitted onto the fiber by the data port. — No action required. Red Data Selection switch is set to an invalid setting. Data Selection switch is set to setting 6, 7, 8, or 9. Set Data Selection switch to the correct setting for the desired data communication (refer to T able A). Not ...

  • Pelco FR85011A - page 27

    C2604M (7/06) 27 Specifications VIDEO Number of Channels 1 Modulation T ype Pulse code modulation, 8-bit resolution Video Input (FT85011A)/ 1.0 Vp-p, 75 ohms; NTSC, PAL, and SECAM Video Output (FR85011A) Bandwidth 6.5 MHz Gain Unity Differential Gain <2% Differential Phase <1° T ilt <1% Signal-to-Noise Ratio >60 dB (CCIR weighted) DA ...

  • Pelco FR85011A - page 28

    28 C2604M (7/06) OPTICAL POWER BUDGET , TRANSMISSION DISTANCE, AND LASER CLASS 1 LIMIT - FT85011A TRANSMITTER AND COMPA TIBLE RECEIVERS Model No. Wavelength Optical Power Budget Maximum T ransmission Distance Laser Class 1 Limit* FT85011A T ransmitter Compatible Receivers Multimode (62.5/125 µm) FT85011AMSTR FR85011AMSTR 1310 nm (video) 26 dB † ...

  • Pelco FR85011A - page 29

    C2604M (7/06) 29 OPTICAL POWER BUDGET , TRANSMISSION DISTANCE, AND LASER CLASS 1 LIMIT - FR85011A RECEIVER AND COMPA TIBLE TRANSMITTERS Model No. Wavelength Optical Power Budget Maximum T ransmission Distance Laser Class 1 Limit* FR85011A Receiver Compatible T ransmitters Multimode (62.5/125 µm) FR85011AMSTR FT85011AMSTR 1310 nm (video) 26 dB † ...

  • Pelco FR85011A - page 30

    30 C2604M (7/06) . This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment. C2604M.book Page 30 Friday, July 14 ...

  • Pelco FR85011A - page 31

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FR/FT/FS Series fiber optic products. • Three years on Genex ® Series pr ...

  • Pelco FR85011A - page 32

    ® United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 C2604M.book Page 32 Friday, July ...

Manufacturer Pelco Category Network Hardware

Documents that we receive from a manufacturer of a Pelco FR85011A can be divided into several groups. They are, among others:
- Pelco technical drawings
- FR85011A manuals
- Pelco product data sheets
- information booklets
- or energy labels Pelco FR85011A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Pelco FR85011A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Pelco FR85011A, service manual, brief instructions and user manuals Pelco FR85011A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Pelco FR85011A.

Similar manuals

A complete manual for the device Pelco FR85011A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Pelco FR85011A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Pelco FR85011A.

A complete Pelco manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Pelco FR85011A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Pelco FR85011A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Pelco FR85011A, that we can find in the current document
3. Tips how to use the basic functions of the device Pelco FR85011A - which should help us in our first steps of using Pelco FR85011A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Pelco FR85011A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Pelco FR85011A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Pelco FR85011A?

Use the form below

If you did not solve your problem by using a manual Pelco FR85011A, ask a question using the form below. If a user had a similar problem with Pelco FR85011A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)