Manual Omron BUM100S

16 pages 1.03 mb
Download

Go to site of 16

Summary
  • Omron BUM100S - page 1

    1 Do not use this product in applications which require an extremely high degree of reliability and safety , such as those listed below . (This product is designed and manufactured for use for OA equipment such as personal computers.) • Medical equipment or system that may cause death dir ectly • Applications that directly af fect the safety of ...

  • Omron BUM100S - page 2

    2 When the battery is dead, replace it immediately or stop using the unit. • Continuing to use the unit may cause a fire. Do not place objects on the unit, and do not drop metal objects onto the unit. • Doing so may cause distortion/damage to the case or a failure of the internal circuit, and may cause a fir e. Do not use the product in a close ...

  • Omron BUM100S - page 3

    3 Notes Charge the battery (for at least 24 hours) immediately after purchase. • If you do not use the unit for a long time after pur chase, the battery per for mance may deteriorate and it may become unusable. • The battery can be charged once the AC input plug of the UPS is connected to a wall outlet (commercial power). When storing the UPS, ...

  • Omron BUM100S - page 4

    4 1-2 Checking the accessories Make sure that all accessories ar e included and that there is no external damage. If you notice any defects, immediately contact the shop of purchase. 1. Instruction manual (Japanese/English edition) .... 1 2. Battery connection cable + Cable clamps (BUM100S only) ............................................. 1 set 3 ...

  • Omron BUM100S - page 5

    5 2-1 Installation Install the additional battery unit. Do not use this unit in any position other than the correct positions indicated in the illustration below . Correct positions - バッテリ  交換 バッテリ  増設 ブザー停止/テスト 電源出力 バイパス 運転 BU150SW - バッテリ  交換 バッテリ  増設 ブ? ...

  • Omron BUM100S - page 6

    6  ● For BUM300S Correct Positions Be careful not to get your fingers caught when arranging the unit. Caster at the bottom may be removed when sitting horizontally. Incorrect Positions BATTRY UNIT BATTRY UNIT * Do not place the UPS or the additional batter y unit on top of each other . The upper unit ma y f all down by vibr ation etc. - バッ? ...

  • Omron BUM100S - page 7

    7 2-2 Connecting the additional battery unit ( BUM100S/150S/300S ) Y ou can add only one additional battery unit. 2-2-1 BUM100S connection procedure / Connectable UPS: BU100SW/BU1002SW (1) Remove the cover of the additional battery connector on the back of the UPS. Also remove the scr ews on the lower part of the signal card expansion slot cover . ...

  • Omron BUM100S - page 8

    8 Additional battery signal connection Additional battery connection Additional battery signal connection Additional battery connection ON     OFF Overcurrent protection switch Battery connection cable 2-2-3 BUM300S connection procedure / Connectable UPS : BU3002SW (1) Connect the battery connection cable to the batter y connectors on the rea ...

  • Omron BUM100S - page 9

    9 3. Replacing the battery The battery can be replaced while the UPS is stopped. (power supply output stopped) Caution When an additional battery unit (BUM100S/BUM150S/BUM300S) is connected to the UPS, replace the UPS battery when replacing the batteries of the additional battery unit. Y ou cannot perfor m batter y replacement of the additional bat ...

  • Omron BUM100S - page 10

    10 3. Remove (anti-clockwise rotation) the 2 scr ews that hold the plate cover in place. ➀ Pull the plate cover towar ds you ➁ , and lift it up to remove it. ➂ 4. Remove both battery packs by pulling on the pullout label at the bottom of each battery pack. Use the red tape on top of the battery pack, which is 10 cm from the inner edge of the ...

  • Omron BUM100S - page 11

    11 Tighten the 2 screws. 1 2 7. Attach the front panel. Insert the tab at the bottom of the front panel into the hole in the main body ➀ , and push the plate cover towards the main body . ➁ Use a screwdriver to secur ely tighten (clockwise) the 2 screws at the top of the fr ont panel. 6. Securely connect the connectors. ➀ Secure the connector ...

  • Omron BUM100S - page 12

    12 Additional battery unit (BUM300S) r eplacement procedur e For information on UPS battery replacement pr ocedure, r efer to the UPS instruction manual. 1. Use a screwdriver to loosen ( anti-clockwise r otation ) the 4 screws on the fr ont panel of the additional battery unit until they turn freely . BATTRY UNIT 1 B AT TRY UN IT Loosen the 4 screw ...

  • Omron BUM100S - page 13

    13 4. Remove the 4 battery packs by pulling on the pullout label at the bottom of each battery pack. Use the red tape on top of the battery pack, which is 10 cm from the inner edge of the battery , to gauge how much further you need to pull the batter y to remove it. Hold the battery securely with both hands so as not to drop it. Caution Do not hol ...

  • Omron BUM100S - page 14

    14 6. Securely connect the connectors. ➀ Secure the connectors to the plate cover . ➁ Y ou may hear a “pop” sound when you connect the battery if it is replaced after the unit’s operation is stopped, but this sound is not abnormal. If you cannot secure a connector to the plate cover , the connector is not completely connected. Connect the ...

  • Omron BUM100S - page 15

    15 <After replacing the battery during operation...> Press the beep stop/test button for 5 to 10 seconds, to perform a self-diagnostic test. Normal operation r esumes after the test for about 10 second. If the beeping sounds, the beeping stops at the first pr ess of the button and starts test in the second press of the button. If the battery ...

  • Omron BUM100S - page 16

    16 K1L-D-05096C Dimensions 395 15 91 26 402 285 φ15 φ25 224 13 10 64 145 M 4 screw BUM100S <Unit: mm / T olerance: ± 1mm> ● BUM100S/BUM150S ● BUM300S 21 509 329 402 299 117 66 28 432 56 178 286 213 3 99 BUM300S <Unit: mm / T olerance: ± 1mm> Power cable (approximately 1.8m) 360 ...

Manufacturer Omron Category Marine Instruments

Documents that we receive from a manufacturer of a Omron BUM100S can be divided into several groups. They are, among others:
- Omron technical drawings
- BUM100S manuals
- Omron product data sheets
- information booklets
- or energy labels Omron BUM100S
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omron BUM100S.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omron BUM100S, service manual, brief instructions and user manuals Omron BUM100S. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omron BUM100S.

Similar manuals

A complete manual for the device Omron BUM100S, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omron BUM100S by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omron BUM100S.

A complete Omron manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omron BUM100S - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omron BUM100S, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omron BUM100S, that we can find in the current document
3. Tips how to use the basic functions of the device Omron BUM100S - which should help us in our first steps of using Omron BUM100S
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omron BUM100S
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omron BUM100S in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omron BUM100S?

Use the form below

If you did not solve your problem by using a manual Omron BUM100S, ask a question using the form below. If a user had a similar problem with Omron BUM100S it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)